IR TO WTER Heat Pumps & Chillers
The ffordable GREEN Solution R407C Ozone Friendly Refrigerant ir to Water Heating & Cooling Reduce carbon footprint, save energy Self contained units, plug & play Unmatched Zoning Capabilities N Models vailable in 4 different sizes (3, 5, 10, & 20 ton) Cooling only or heat pump models available Produces water/glycol cooled from 4 C (39 F) down to -6 C (21 F) High efficiency scroll compressors with low power consumption. ntifreeze electric heater for the storage tank. (Standard on N 3007) Water side differential pressure switch standard on all models. High efficiency stainless steel heat exchangers. xial flow fan units for extremely quiet operation. Metallic protective cabinet with rustproof polyester paint. Equipped with water pump and storage tank.
Many applications such as Radiant in-floor heating, low temperature baseboard heating, towel warmers, domestic hot water systems, and even solar technologies are all supported by the ermec ir-to-water Heat Pumps & Chillers. There are no special tools to connect, no complicated wiring, and no refrigeration piping required. This advanced unit simply uses water or glycol to heat and cool all year round. The ermec dvantage No Refrigerant Handling: No need to charge our air cooled hydronic chiller system with refrigerant. ermec closed refrigerant system does away with the need for certified installation technicians to handle refrigerants. Because there are no refrigerant lines outside the outdoor water chiller cabinet, installation costs are lower versus standard DX ducted split systems. No Ductwork: Cooling with ermec chillers and our lines of ductless hydronic fan coils means running small, flexible water pipes into spaces within the walls instead of large ductwork runs. This can save hundreds of useable square feet for living space. Using ductless fan coils results in zero percent duct air loss compared to traditional ducted systems. Zero Line Length Limitations: With insulated water lines carrying the cooling capacity, there is minimal capacity loss allowing for unlimited line length runs to any hydronic fan coil. This method of delivering rated capacity is far more efficient than traditional direct expansion ductless split systems. Zoned Cooling: With ermec air-cooled chillers and ductless fan coils, you condition only the spaces you designate; not the whole building as opposed to a traditional ducted central C system. This fact allows for diversity and load shifting when doing load and sizing calculations. This reduces installed cost, as well as, operating costs for years to come. Whisper Quiet Operation: The ermec Fan Coils are the world's quietest fan coils. t a 25.5 decibel rating, the fan coils emit lower noise than a whisper quiet library (30dB). These are widely used in many hotel and condiminium applications that require a low-noise system. Other notable advantages with ermec, is its plug and play feature. These remarkable units come equipped with built in, expansion tank, water storage tank, pump, and strainers. Reducing the overall installation cost over traditional systems.
Case Studies ermec is flexible with many applications in many different geographical locations. The N Heat Pumps and Chillers are recognized for their efficiency and reliability. Most importantly, its unique plug & play feature makes it incredibly easy to install. Many establishments have embraced the ermec product line. Some of which include major hotel chains, schools, hospitals, churches, large custom homes, and much more. To view these and many more ermec Case Studies, please visit us online at: www.aermec.us or www.aermec.ca Simple, reliable, and proven worldwide Moda Hotel (British Columbia, Canada) This prehistoric hotel built in 1908 is located in the heart of the rts & Entertainment district of downtown Vancouver. The hotel consists of 57 rooms that hold a modern as well as contemporary interior design. Situated inside the hotel lobby, hotel guests can wine and dine at the "Uva Wine Bar" and "Cibo Trattoria". One of the great benefits ermec was able to offer, was being able to operate the units as heat pumps with a boiler for backup for a complete heating system. Each suite has its own fan coil with wireless thermostat which also connects wirelessly to the reservation bridge of the main lobby. The benefits of this wireless system is so that rooms that are not occupied by guests are not being heated or cooled, thus saving energy. St.Lawrence Church (Toronto, Canada) ermec fan coils were installed and the existing radiator covers were reinstalled. ll piping was run in the existing basement pipe chase. Fan coils were hung at the ceiling in the banquet hall utililizing the existing pipe chase as well. Two new condensing boilers replace the existing natural gas boiler. Installed were 5,10, and 20 ton chillers along with 44 fan coils, phase converters, and 2 boilers for domestic hot water. The goal was met, no changes to the beautiful sanctuary, a system that was quieter than opening the windows. Both, sanctuary and banquet hall could be cooled, higher efficiency heating, and all within budget. Beverly Hilton (Los ngeles, California) This hotel was originally built in 1955. It is composed of 570 bedrooms, restaurants, well-being centre, shopping,centre, garden, and swimming pool. Remodeled in 2003, ermec was chosen for its efficient cooling and whisper quiet fan coils. Robin Ridge Winery (British Columbia, Canada) Three ermec N417H heat pumps are being used to provide comfort, cooling, and heating for the restaurant area as well as refrigeration for the wine storage area. The winery chills glycol at -4º C (24ºF) for the production of Ice Wine.
Turning Water into Comfort ermec N Chillers and Heat Pumps have been designed and constructed to satisfy small and medium sized cooling and heating applications in residential or commercial venues. The unit is designed for using both hydraulic circuits (evaporator and condensing unit); therefore it can be used both like water chiller and heat pump. The communication between chiller and heat pump operation is obtained managing the chiller circuit. vailable in 4 sizes, the units are characterized by their silent operation, high efficiency performance, and reliability, thanks to the use of heat exchangers with a large exchange surface and high-efficiency silent scroll compressors. Water transfers 3,500 times the energy as the same volume of ir. Fact: 90% of North mericans use forced air to heat and cool commercial and residential spaces. Fact: 98% of European commercial and residential utilizes water for heating and cooling. The units can be arranged to satisfy a wide range of system requirements. With base or with integrated pump and storage tank. Condensing units without an evaporator are also available. Genious Design ermec offers complete flexibility to work with many applications. The residential home shown below demonstrates how versatile the ermec system can be. Solar panel Ducting Floor standing Fan Coils Radiant In-Floor Heating Hot Water Tank or Tankless Water Outdoor Unit
N Technical Specs Version ll N 0417 10.4 35486 N 0807 18.2 62100 N 1507 35 119425 N 3007 70 / 66.5** 238850/226907 3.86 6.40 12.9 24.05/ 24.2 ** 19.8 28.5 40 71.5/77.5** ll 1790 7.88 3130 13.78 6020 26.50 12040/11440** 53.01 / 50.36 ** 61/8.84 57/ 8.26 68/9.86 128/18.56133**/19.29 H 11.8 40260 19.2 65510 35.0 119425 75.0 255910 H 4.60 7.10 12.7 27.5 H 22.3 29.7 45.0 81.1 Minimum Circuit mpacity (MC) H/ 28/28 36/36 53/53 117/120 H 2030 8.93 3300 14.52 6020 26.50 12900 56.79 ll 37 41 49 49 ll 5300 3120 6700 3943 12400 7298 21000 12360 ll 1/25.4 0.85/2.2g 3 5.0/ 1.32 35/9.24 1.25/31.75 1.41/.372g 3 5.0/ 1.32 75/19.81 1.25/31.75 3. 1/.818g 1 8/2.11 145/38.3 2.5/ 63.5 6.48/1.4g 1 24/ 6.34 500/132 MIN COMPONENTS 1. Switchboard 2. ir Side Exchanger 3. Fan Section 4. Water Side Exchanger 5. High Pressure Switch 6. Compressor 7. Expansion Tank 8. Water Storage Tank 9. Pump 10. Low Pressure Switch 11. Thermostatic Valve 12. Water Filter 13. Safety Valve 14. Differential Pressure Switch N 0807
N Dimensions