AIR TO WATER. Heat Pumps & Chillers

Similar documents
McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Product Line Introduction. Karl Zhang Technical support engineer

Table of Contents. 2 aermec.us

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

IT'S HARD TO STOP A TRANE

The Benefits Really Add Up

HVAC - Central System Thermal Storage

HEATING COOLING HOT WATER PRODUCT LINE

Multi-Positional Vertical Combination

SIMPLICITY FULL MODULARITY?

Water Chiller Climate Control from. Integrated FREE Hot Water Heating

Heat Pumps COMFORT NEED IT. When You

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Why Choose an AquaCal Heat Pump to Heat My Pool?

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

Fan Coils & Accessories

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

GARCIA GALUSKA DESOUSA Consulting Engineers

IPS. The Affordable Green HVAC Solution! Ideal for select service hospitality, assisted living, condos, apartments and dorms.

CANADA S #1 SELLING BRAND OF DUCTLESS. mitsubishicomfort.ca

Air-to-Water Heat Pumps + Boilers A Dynamic Duo

cool and comfortable Air Conditioners

Lennox Mini-Split Systems Year-Round Comfort and Performance

Chilled Water system

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

That s why we call it Smarter from the Ground Up.

Unico Training. Welcome to Unico!

Market Benefits of Electric Resistance Heat

PRODUCT RANGE POOL HEATING AND COOLING. Swimming pool heat pumps, heat cool systems and water chillers

Consumer Features & Benefits of Energy Efficient Products

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

AFFORDABLE RENEWABLE CLEAN

Commercial Heat Pump Water Heating Solutions

GEOTHERMAL HEAT PUMPS

Trailblazer air cooled scroll chillers

NET ENERGY WATER LOOPS A clear path to net zero energy buildings

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

SIMPLICITY OR FULL MODULARITY?

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

FORCED AIR + HYDRONIC

Air Conditioning & Heating. Ductless Heating & Cooling Systems

water to water heat pumps

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

Solar Thermal Planning Worksheet Date: / /

Heat Cool system. Take control of your pool heating and cooling with the Calorex 34 and new Pro-Pac ranges

TRANQUILITY WATER-TO-WATER SERIES

"I'm a Daikin Comfort Pro"

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Heating Systems Company LAARS INTRODUCES. The MASCOT LX. A Boiler. An All-in-One Answer to Your Home Heating and Hot Water Needs

Oilon Ground Source Heat Pumps

SECTION/SUBSECTION (scroll down to view more listings; this list is arranged alphabetically) SCOPE. AHRI Section-Subsection Scopes

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Appendix 13. Categories of Cooling and Heating systems

Residential and Light Commercial Ductless Systems Catalog

SERVICE ASSISTANT OVERVIEW FDSI Online Training

SP-3. Central Air Anywhere. Flexible solutions for cooling and heating your space.

This is one of several geothermal projects designed and installed by contractor Nelson Mechanical Design, Martha s Vineyard.

Infinity 19VS. Air Conditioner with Variable-Speed Technology. Variable-Speed, High-Efficiency Air Conditioner with up to 19.

Nordic Heat Pump Product Guide

Inverter Ducted Split Air Source Heat Pump System with Inverter Drive Technology

SITE SYSTEMS: FANNIE MAE EXPECTED USEFUL LIFE TABLES (FMEUL)

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

stylish, energy efficient, sustainable electric heating solution for every living space

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

COOL AND HEAT YOUR ENTIRE HOME OR JUST ONE ROOM AT A TIME

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

WALL MOUNT COMBINATION GAS HEATER SERIES. HIGH EFFICIENCY HYDRONIC HEATERS WITH BUILT-IN DOMESTIC HOT WATER

Your Chiller Solution For Efficiency And Reliability. McQuay Dual Compressor Centrifugal Chillers 160 to 2500 Tons

The energy-efficient alternative

Heating and Cooling IN THIS CHAPTER

Ductless and ducted mini splits- with case studies. Heat Pump and Air Condi1oning For Energy Design Conference By Mike D. Wilson- Dakota Supply Group

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

CHAPTER IV AIR DISTRIBUTION AND BALANCE

Product Lines

High Performance Air Systems. An AMCA International White Paper. December, 2015

APPLICATION GUIDE BEAMS

Enriching Environments

LOW TEMPERATURE HYDRONIC HEATING FOR COLD CLIMATES TRAVIS SMITH PRESIDENT T AND T MOUNTAIN BUILDERS INC

Energy Efficiency HOSPITALITY.

Geothermal Heating and Cooling Using Ground Source Heat Pumps. Prepared by: Steven Forrester, P.E. Principal

DUCTLESS FULL LINE CATALOG

Mitsubishi System Technologies:

Shippensburg University

Infinity 16. Air Conditioner. Energy-Efficient Air Conditioner with up to 16.0 SEER

PREFERRED SERIES AIR CONDITIONERS

Circulators high efficiency ECM Circulators

KINGSBOTTLE AUSTRALIA

CHAPTER 4. HVAC DELIVERY SYSTEMS

Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Air to Water Heat Pump Utilising Natural Refrigerant C02

Liebert Mini-Mate2 1 To 8 Tons

Transcription:

IR TO WTER Heat Pumps & Chillers

The ffordable GREEN Solution R407C Ozone Friendly Refrigerant ir to Water Heating & Cooling Reduce carbon footprint, save energy Self contained units, plug & play Unmatched Zoning Capabilities N Models vailable in 4 different sizes (3, 5, 10, & 20 ton) Cooling only or heat pump models available Produces water/glycol cooled from 4 C (39 F) down to -6 C (21 F) High efficiency scroll compressors with low power consumption. ntifreeze electric heater for the storage tank. (Standard on N 3007) Water side differential pressure switch standard on all models. High efficiency stainless steel heat exchangers. xial flow fan units for extremely quiet operation. Metallic protective cabinet with rustproof polyester paint. Equipped with water pump and storage tank.

Many applications such as Radiant in-floor heating, low temperature baseboard heating, towel warmers, domestic hot water systems, and even solar technologies are all supported by the ermec ir-to-water Heat Pumps & Chillers. There are no special tools to connect, no complicated wiring, and no refrigeration piping required. This advanced unit simply uses water or glycol to heat and cool all year round. The ermec dvantage No Refrigerant Handling: No need to charge our air cooled hydronic chiller system with refrigerant. ermec closed refrigerant system does away with the need for certified installation technicians to handle refrigerants. Because there are no refrigerant lines outside the outdoor water chiller cabinet, installation costs are lower versus standard DX ducted split systems. No Ductwork: Cooling with ermec chillers and our lines of ductless hydronic fan coils means running small, flexible water pipes into spaces within the walls instead of large ductwork runs. This can save hundreds of useable square feet for living space. Using ductless fan coils results in zero percent duct air loss compared to traditional ducted systems. Zero Line Length Limitations: With insulated water lines carrying the cooling capacity, there is minimal capacity loss allowing for unlimited line length runs to any hydronic fan coil. This method of delivering rated capacity is far more efficient than traditional direct expansion ductless split systems. Zoned Cooling: With ermec air-cooled chillers and ductless fan coils, you condition only the spaces you designate; not the whole building as opposed to a traditional ducted central C system. This fact allows for diversity and load shifting when doing load and sizing calculations. This reduces installed cost, as well as, operating costs for years to come. Whisper Quiet Operation: The ermec Fan Coils are the world's quietest fan coils. t a 25.5 decibel rating, the fan coils emit lower noise than a whisper quiet library (30dB). These are widely used in many hotel and condiminium applications that require a low-noise system. Other notable advantages with ermec, is its plug and play feature. These remarkable units come equipped with built in, expansion tank, water storage tank, pump, and strainers. Reducing the overall installation cost over traditional systems.

Case Studies ermec is flexible with many applications in many different geographical locations. The N Heat Pumps and Chillers are recognized for their efficiency and reliability. Most importantly, its unique plug & play feature makes it incredibly easy to install. Many establishments have embraced the ermec product line. Some of which include major hotel chains, schools, hospitals, churches, large custom homes, and much more. To view these and many more ermec Case Studies, please visit us online at: www.aermec.us or www.aermec.ca Simple, reliable, and proven worldwide Moda Hotel (British Columbia, Canada) This prehistoric hotel built in 1908 is located in the heart of the rts & Entertainment district of downtown Vancouver. The hotel consists of 57 rooms that hold a modern as well as contemporary interior design. Situated inside the hotel lobby, hotel guests can wine and dine at the "Uva Wine Bar" and "Cibo Trattoria". One of the great benefits ermec was able to offer, was being able to operate the units as heat pumps with a boiler for backup for a complete heating system. Each suite has its own fan coil with wireless thermostat which also connects wirelessly to the reservation bridge of the main lobby. The benefits of this wireless system is so that rooms that are not occupied by guests are not being heated or cooled, thus saving energy. St.Lawrence Church (Toronto, Canada) ermec fan coils were installed and the existing radiator covers were reinstalled. ll piping was run in the existing basement pipe chase. Fan coils were hung at the ceiling in the banquet hall utililizing the existing pipe chase as well. Two new condensing boilers replace the existing natural gas boiler. Installed were 5,10, and 20 ton chillers along with 44 fan coils, phase converters, and 2 boilers for domestic hot water. The goal was met, no changes to the beautiful sanctuary, a system that was quieter than opening the windows. Both, sanctuary and banquet hall could be cooled, higher efficiency heating, and all within budget. Beverly Hilton (Los ngeles, California) This hotel was originally built in 1955. It is composed of 570 bedrooms, restaurants, well-being centre, shopping,centre, garden, and swimming pool. Remodeled in 2003, ermec was chosen for its efficient cooling and whisper quiet fan coils. Robin Ridge Winery (British Columbia, Canada) Three ermec N417H heat pumps are being used to provide comfort, cooling, and heating for the restaurant area as well as refrigeration for the wine storage area. The winery chills glycol at -4º C (24ºF) for the production of Ice Wine.

Turning Water into Comfort ermec N Chillers and Heat Pumps have been designed and constructed to satisfy small and medium sized cooling and heating applications in residential or commercial venues. The unit is designed for using both hydraulic circuits (evaporator and condensing unit); therefore it can be used both like water chiller and heat pump. The communication between chiller and heat pump operation is obtained managing the chiller circuit. vailable in 4 sizes, the units are characterized by their silent operation, high efficiency performance, and reliability, thanks to the use of heat exchangers with a large exchange surface and high-efficiency silent scroll compressors. Water transfers 3,500 times the energy as the same volume of ir. Fact: 90% of North mericans use forced air to heat and cool commercial and residential spaces. Fact: 98% of European commercial and residential utilizes water for heating and cooling. The units can be arranged to satisfy a wide range of system requirements. With base or with integrated pump and storage tank. Condensing units without an evaporator are also available. Genious Design ermec offers complete flexibility to work with many applications. The residential home shown below demonstrates how versatile the ermec system can be. Solar panel Ducting Floor standing Fan Coils Radiant In-Floor Heating Hot Water Tank or Tankless Water Outdoor Unit

N Technical Specs Version ll N 0417 10.4 35486 N 0807 18.2 62100 N 1507 35 119425 N 3007 70 / 66.5** 238850/226907 3.86 6.40 12.9 24.05/ 24.2 ** 19.8 28.5 40 71.5/77.5** ll 1790 7.88 3130 13.78 6020 26.50 12040/11440** 53.01 / 50.36 ** 61/8.84 57/ 8.26 68/9.86 128/18.56133**/19.29 H 11.8 40260 19.2 65510 35.0 119425 75.0 255910 H 4.60 7.10 12.7 27.5 H 22.3 29.7 45.0 81.1 Minimum Circuit mpacity (MC) H/ 28/28 36/36 53/53 117/120 H 2030 8.93 3300 14.52 6020 26.50 12900 56.79 ll 37 41 49 49 ll 5300 3120 6700 3943 12400 7298 21000 12360 ll 1/25.4 0.85/2.2g 3 5.0/ 1.32 35/9.24 1.25/31.75 1.41/.372g 3 5.0/ 1.32 75/19.81 1.25/31.75 3. 1/.818g 1 8/2.11 145/38.3 2.5/ 63.5 6.48/1.4g 1 24/ 6.34 500/132 MIN COMPONENTS 1. Switchboard 2. ir Side Exchanger 3. Fan Section 4. Water Side Exchanger 5. High Pressure Switch 6. Compressor 7. Expansion Tank 8. Water Storage Tank 9. Pump 10. Low Pressure Switch 11. Thermostatic Valve 12. Water Filter 13. Safety Valve 14. Differential Pressure Switch N 0807

N Dimensions