Update on SFPE Design Fire Scenarios Standard. Charles Fleischmann University of Canterbury

Similar documents
Home Fires Involving Heating Equipment

U.S. STRUCTURE FIRES IN OFFICE PROPERTIES

U.S. STRUCTURE FIRES IN NURSING HOMES. Jennifer Flynn Fire Analysis and Research Division National Fire Protection Association

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

SUPPRESSION SALES I INSTALLATION I SERVICE

STRUCTURE FIRES IN EDUCATIONAL PROPERTIES

Medical Facility Fires

HOME STRUCTURE FIRES INVOLVING KITCHEN EQUIPMENT OTHER THAN COOKING EQUIPMENT

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

Structure Fires in Hotels and Motels

Heat Release Rate of an Open Kitchen Fire of Small Residential Units in Tall Buildings

Structure Fires in Residential Board and Care Facilities

Appendix A: US Fire Statistics Tables

There are many different types of restaurants from chain

For more information on the MARR program or any questions on the product list, please refer to or contact MARR at

University Housing Fires

Home Fires Resulting from

Multiple-Fatality Fires in Residential Buildings

FIRES IN VACANT BUILDINGS. Marty Ahrens February 2018

Home Structure Fires that Began with Decorations

Fires in Petroleum Refineries and Natural Gas Plants Annual Averages and Trends since 1980

Performance Metrics for First Responder Locating/Tracking Technologies

Fire Hazards of Exterior Wall Assemblies Containing Combustible Components

The general safety requirements in the IFC were developed to. General Precautions against Fire CHAPTER

Estimating Fires When a Product is the Primary Fuel But Not the First Fuel, With an Application to Upholstered Furniture

One- and Two-Family Residential Building Fires ( )

Heating Fires in Residential Buildings

Item First Ignited in Home Structure Fires in which Upholstered Furniture Contributed to Flame Spread Beyond the Object of Origin

Home Cooking Fires. November 2018 Marty Ahrens. November 2018 National Fire Protection Association

The general safety requirements in the IFC were developed to. General Precautions Against Fire CHAPTER

2012 UPC Chapter 5 Water Heaters RV

Home Fires Involving Cooking Equipment

Thanksgiving Day Fires in Residential Buildings

Home and Non-Home Structure Fires Caused by Lightning Fires Reported to Local Fire Departments

Smoke Alarm Presence and Performance in U.S. Home Fires By Marty Ahrens, NFPA, Quincy, MA. 1. Abstract

FIRE PREVENTION AND SAFETY IN THE HOME CW2 BILL GUNNETT

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

Fixed fire protection solutions

Fire Safety Education in Multi- Unit Residential Buildings

Artificial Trees and Fire Performance

Residential Building Fires ( )

General Safety Requirements

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Smoke Alarm Research at NIST

Report on First Revisions with Statement June 2014 NFPA 101

Fatal Fires in Residential Buildings

AHC Meeting #7 July 12-13, Fire Safety WG Report. A Cycle Approved Code Changes

The Worldwide Use of Fire Sprinklers

Recent BRANZFIRE enhancements and validation

Home Structure Fires in which Natural Gas or LP-Gas was Ignited by Lightning, by Year

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Reported Fires in High-Rise Structures in Selected Occupancies with and without Automatic Extinguishing Systems by Extent of Smoke Damage

Canadian Association of Fire Chiefs Steve Thurlow Dillon Consulting Limited. September 21, 2015

COMMERCIAL Washington Incentives

FUEL TYPE relating to UK deaths from unintentional carbon monoxide poisoning from to

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

THE SMOKING-MATERIAL FIRE PROBLEM

DEALING WITH FIRE SAFETY

Construction Site Fires

Home Fires Started by Smoking

Fire Hazard Analysis of Technical Area 53 Building 1

Fire Loss Reduction in Industrial Buildings - Risk Cost Benefit Study

SCOPE OF SERVICE: MAGNETIC ROACH BAIT

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

From 2005 to 2007, an estimated 108,400 winter

Home Structure Fires Started by Lightning

Inspection and Life Safety Education Division. Public Safety Committee September 9,

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities

Home Fires Involving Cooking Equipment

Patrick D. Gallagher, Under Secretary of Commerce for Standards and Technology and Director

Prevention. Education

NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC

IMC Significant Changes Summary Tier I

Performance of Smoke Detectors and Sprinklers in Residential and Health-Care Occupancies

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

We are committed to making the facts and solutions known to government officials and private citizens alike so that a solution is found and pursued.

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Craig A. Rush Presents Edinborough Circle, Perrysburg

Comparative Evaluation Method for Fire Safety Design of Large Storage Spaces

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Family Foster Home Fire Safety Evaluation Checklist Instructions

Smoke Alarm Research at NIST

,4X IMPORTANT SAFETY INSTRUCTIONS

Fire Cause Determination

COMMERCIAL PLAN SUBMITTAL CHECK LIST Mercantile / Business / Educational / Storage / Factory Industrial / Hazardous / Institutional

Applying the New Zealand Performance Based Design Fire Framework to Buildings Designed in Accordance with NFPA5000

Following are code change proposals submitted through Adhoc Health from General study group and related changes. General. Position.

THE SMOKING-MATERIAL FIRE PROBLEM

Agency for Health Care Administration

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

SELECTIONS FROM HOME COOKING FIRE PATTERNS AND TRENDS CHARCOAL GRILLS

WASHINGTON STATE PATROL

Copy of article submitted to Fire Safety Engineering for publication January/February 2009

NON-FIRE CARBON MONOXIDE INCIDENTS

Considerations in the Design of Smoke Management Systems for Atriums

SCOPE OF SERVICE: MAGNETIC ROACH BAIT

Agency for Health Care Administration

Figure 1. Structure Used For the Simulations.

Transcription:

Update on SFPE Design Fire Scenarios Standard Charles Fleischmann University of Canterbury

Mission - To develop a standard on methods to create design fire scenarios for a performance-based fire protection design. Methods that are developed are to be defendable, transparent, and reproducible Apply the methods to develop recommended design fire scenarios

Who is on the committee? Name Employer Interest Represented Country Kees Both Promat Research Producer Netherlands Jason Butler Savannah River Nuclear Solutions Facilities Management USA Jason Floyd JENSON HUGHES Research and testing USA Craig Hofmeister The Fire Consultants Design Engineer USA M. C. Hui BCA Logic Pty Ltd Design Engineer Australia Martin Nillson AIG Insurance Sweden David Stroup US Nuclear Regulatory Commission Enforcement official USA Piotr Tofilo The Main School of Fire Service Specialist Poland Colleen Wade BRANZ Research and testing New Zealand Shawn Wrightson Koffel Associates Design Engineer USA Jason Smart American Wood Council Producer USA Alternates John Stauder The Fire Consultants Alternate to Craig Hofmeister USA Don Turno Savannah River Nuclear Solutions Alternate to Jason Butler USA

Where is the committee heading? Building-Occupant systems 1 Triplet Objective Criteria Scenario Characterising the hazards based on the occupancy using existing fire statistics Develop of short list of scenarios (general common to multiple buildings & occupancy specific) Quantify the design fires 1 Jutras, I., Meacham, B., Tubbs, B. and Hurley, M., A Proposed Approach for Developing and Presenting Fire Scenarios, Design Fires and Criteria for Regulation and Design, 10 th PBD conference, Brisbane, Australia

Short List of Scenarios (2009-2013) NFPA Data non-residential-annually ~100,000 fire ~70 civilian deaths ~1500 civilian injuries ~$2.6 billion direct property loss http://www.nfpa.org/research/reports-and-statistics/fires-in-the-us/overall-fire-problem/non-residentialstructure-fires

NFPA Data - Occupancies Mercantile/Stores Education/Schools Offices Industrial Hotels/Motels Warehouses Restaurants & Bars Religious & funeral Health Care Nursing homes Hospitals and hospices Mental Health Clinics and doctors office

Criteria Used to Develop List of Potential Scenarios Analysis based on area of origin data >5% of all fires in this class of building, or >2 fatalities/year and disproportionate number of fatalities, or >20 injuries/year and disproportionate number of injuries, or >$5x10 6 /year and disproportionate damage estimate All fires, confined fires, non-confined fires

Proportionality Factor Proportionality Factor = #of ( fatalities) # fires in the space all ( fatalities) all fires Where the value in () is fatalities, injuries, damage in the space 2

Categories of Structure Fire All fires Confined fires - confined cooking fires, confined chimney or flue fires, confined trash fires, confined fuel burner or boiler fires, confined commercial compactor fires, and confined incinerator fires Non-confined fires

Exemplar NFPA Data Structure Fires in Store and Mercantile, by Area of Origin 2009-2013 Annual Averages Proportionality Factor Direct Property Damage (in Fatalities /# fires Injuries /# fires Damage /# fires Area of Origin Fires Civilian Fatalities Civilian Injuries Millions) Kitchen or cooking area 2,250 16.5% 0 0.0% 42 14.0% $28 4.7% 0.0 0.8 0.3 Non-confined 510 5.8% 0 0.0% 30 11.0% $27 4.5% 0.0 1.9 0.8 Confined 1740 36.3% 0-12 41.4% $1 25.0% 0.0 1.1 0.7 Laundry room or area 780 5.7% 0 0.0% 14 4.7% $11 1.8% 0.0 0.8 0.3 Non-confined 630 7.2% 0 0.0% 13 4.8% $9 1.5% 0.0 0.7 0.2 Confined 160 3.3% 0-1 3.4% $2 50.0% 0.0 1.0 15.0 Unclassified outside area 730 5.4% 0 0.0% 2 0.7% $8 1.3% 0.0 0.1 0.2 Non-confined 250 2.8% 0 0.0% 2 0.7% $8 1.3% 0.0 0.3 0.5 Confined 480 10.0% 0-0 0.0% $0 0.0% 0.0 0.0 0.0 Sales of showroom area 550 4.0% 1 11.1% 25 8.4% $72 12.0% 2.7 2.1 3.0 Non-confined 490 5.6% 1 11.1% 24 8.8% $72 12.0% 2.0 1.6 2.2 Confined 60 1.3% 0-1 3.4% $0 0.0% 0.0 2.8 0.0 Unclassified equipment or 530 3.9% 0 0.0% 12 4.0% $22 3.7% 0.0 1.0 0.9 Non-confined 370 4.2% 0 0.0% 11 4.0% $22 3.7% 0.0 1.0 0.9 Confined 150 3.1% 0-1 3.4% $0 0.0% 0.0 1.1 0.0 Trash or rubbish chute, area or 470 3.5% 0 0.0% 2 0.7% $1 0.2% 0.0 0.2 0.0 Non-confined 40 0.5% 0 0.0% 1 0.4% $1 0.2% 0.0 0.8 0.4 Confined 430 9.0% 0-1 3.4% $0 0.0% 0.0 0.4 0.0

Summary from NFPA Data Structure Fires in Store & Mercantile by Area of Origin Summary of Scenarios Proportionality Factor > 2 Non-Confined Kitchen or cooking area Laundry room or area Sales of showroom area Maintenance or paint shop area Other known area of origin Non-Vehicle Storage areas (combined) % Fires > 5% Fatalities Injuries Damage

Fire Scenario Non-Confined Fires Hotels and Motels Stores and Mercantile Warehouses Attic or ceiling/roof assembly of concealed space % % % Bedrooms %,F %,F,I %,F,I % % Confined chimney or flue Dining room, bar or beverage area, or cafeteria Exterior roof surface % % % % % Exterior wall surface % % % % Garage or vehicle storage area Heating equipment room $ Kitchen or cooking area % % % % % % % % % Large assembly area with fixed seats $ Laundry room or area % % % % % % Lavatory, bathroom, locker room or check room % % % % % % % Machinery room or area or elevator machinery room % % Maintenance or paint area I,$ Non-Vehicle Storage areas (combined) $ % % Office % % Other known area of origin % % % %,$ % % % % % % % % % Processing or manufacturing area, or workroom % Sales or showroom area %,$ Shipping and receiving or loading area % Small assembly area, less than 100 person capacity % % Storage of supplies or tools or dead storage % Storage room, area, tank, or bin % Trash or rubbish chute, area or container Unclassified equipment or service area % Unclassified outside area Unclassified storage area %,$ % Vacant structural area Office Industrial and Manufacturing Educational Properties Eating and Drinking Establishments Religious and funeral properties Health Care Facilities Nursing Homes Hospital and Hospices Mental Health Facilities Clinics or Doctors' Offices

First Item Ignited Store and Mercantile 2004-2008 Annual Average Direct Property Damage Fires Civilian Injuries (in Millions) Cooking materials, including food 2,000 12% 19-8% $12-2% Non-confined fire 270 2% 10-4% $11-2% Confined fire 1,730 32% 9-4% $1 0% Electrical wire or cable insulation 1,660 10% 12-5% $62-10% Non-confined fire 1,490 14% 10-4% $62-10% Confined fire 170 3% 1-1% $0 0% Flammable and combustible liquids and gases, piping and filter 1,400 9% 107-44% $84-13% Non-confined fire 850 8% 103-42% $84-13% Confined fire 560 10% 5-2% $0 0% Rubbish, trash, or waste 1,400 9% 5-2% $23-4% Non-confined fire 380 3% 3-1% $23-4% Confined fire 1,020 19% 2-1% $0 0% Unclassified item first ignited 1,370 8% 10-4% $45-7% Non-confined fire 910 8% 10-4% $45-7% Confined fire 460 9% 0 0% $0 0% Structural member or framing 830 5% 5-2% $68-10% Non-confined fire 830 8% 5-2% $68-10% Confined fire 10 0% 0 0% $0 0%

Limitations (Scenarios) Data Outside the USA? Prescriptive Codes are preventing potential scenario that does not show up in statistics Ensure flexibility May need to subgroup scenarios (i.e. bulk retail, storage) Process hazards difficult to define Are damage assessments adequate?

Establishing Fire Growth Rates Nilsson, Johansson, & Van Hees, Statistical and Empirical Data Applied to Determine the Effect of Arson. Incident data Currently have from NFPA Incident data - need from NFPA Expert judgement from committee Q=α 1 t 2 Q=α 2 t 2 Probability Density Function Q=α 3 t 2 Q=α 4 t 2 Q=α 5 t 2 Q=α 6 t 2 Cumulative Density Function Q=α 7 t 2

Quantifying Design Fires - Kitchen Scenario Example Common Kitchen Single cooktops, oven, large appliances, small appliances, cabinets, food storage Commercial Kitchens - Multiple cooktops, a number of large appliances and multiple occupants involved in the cooking activities. In addition, a large extraction systems & suppression system

Common Kitchen Scenarios 1. Cooking oil fires 2. Appliances 3. Counter top fire spreading to other combustibles 4. Ignition of stored kitchen/cooking items

Single Pan Domestic Kitchen 40 35 Heat Release Rate (kw) 30 25 20 15 10 5 0 0 60 120 180 240 300 360 420 480 540 600 660 Time (s) B-1 B-2 B-3 Chow - Experimental Evaluation on Performance of Open Kitchen Fire Suppression Systems

Multiple Pan Commercial Kitchen 1400 Heat Release Rate (kw) 1200 1000 800 600 400 2 pans (A1) 6 pans (B-1) 200 0 0 300 600 900 1200 1500 Time (s)

Appliances Heat Release Rate (kw) 1000 900 800 700 600 500 400 300 AP1 AP2 AP3 AP4 200 100 0 0 300 600 900 1200 1500 1800 2100 2400 Time (s) Dishwasher Hietaniemi - Burning of Electrical Household Appliances - An Experimental Study

Fire Spreading to Cabinets Heat Release Rate (kw) 700 600 500 400 300 200 CB-S1 CB-S2 Oak-S1 Oak-S2 PB-S1 100 0 0 120 240 360 480 600 720 840 960 1080 Time (s) Cleary - Smoke Alarm Performance in Kitchen Fires and Nuisance Alarm Scenarios NIST Technical Note 1784

Storage Found in Commercial Kitchens 3000 2500 Pre-flashover Post-flashover Heat Release Rate (kw) 2000 1500 1000 Q=0.1876(t)^2 Q=0.0469(t)^2 Q=0.0117(t)^2 500 0 0 300 600 900 1200 1500 Time (s)

Design Fire Characteristics Appliance Refrigerator freezers (free burning) Refrigerator freezers (in a cupboard) Dishwasher (free burning) Dishwasher max. RHR (kw) 1970 (219) 1526 (534) 411 (91) 548 (in a cupboard) (247) Washing machine 333 (106) Average Effective Heat of Combustion (MJ/kg) 28.1 (0.1) 18.6 (0.1) 31.3 (2.8) 19.5 (0.7) 32.3 (2.0) Average Y smoke (kg/kg) 0.05 (0.018) 0.038 (0.013) 0.036 (0.0004) 0.017 (0.002) 0.021 (0.006) Average Y CO (kg/kg) 0.049 (0.007) 0.048 (0.014) 0.067 (0.010) 0.048 (0.009) 0.038 (0.015) Average Y CO2 (kg/kg) 2.217 (0.072) 1.565 (0.039) 2.810 (0.266) 1.671 (0.016) 2.432 (0.335)

Way Forward Finalize design fire methodology Apply methodology to common & occupancy specific scenarios Develop methodology for fires that don t fall into use/occupancy groups selected Work to define acceptance criteria

Committee Members Needed Outside USA Insurance Enforcement Facility Manager