Instructions for Use Installation and Servicing. To be left with the user

Similar documents
Instructions for Use Installation and Servicing. To be left with the user

Instructions for Use Installation and Servicing. To be left with the user

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Instructions for Use Installation and Servicing. To be left with the user

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Ultracom 2. sxi. Instructions for Use. 12sxi. 18sxi. 30sxi. High Efficiency Condensing System Boilers. To be left with the user. G.C. No.

Instructions for Use Installation and Servicing

Instructions for Use Installation and Servicing. To be left with the user

Instructions for Use Installation and Servicing

Ultracom. 18sxi G.C. No sxi G.C. No Installation and Servicing. High Efficiency Condensing System Boilers

Installation and Servicing

Instructions for Use Installation and Servicing To be left with the user

condens Instructions for Use Betacom 2 24 G.C. No Betacom 2 28 G.C. No

24ci. Instructions for Use Installation and Servicing. To be left with the user. Fanned Flue System Boiler

Instructions for Use Installation and Servicing To be left with the user. Appliance

30ci. 30si. 35ci. Instructions for Use Installation and Servicing. To be left with the user. Fanned Flue. Combination Boiler.

DESIGN, INSTALLATION AND SERVICE INSTRUCTIONS

Instructions for Use, Installation and Servicing ecomax pro

condens Instructions for Use Ultracom 2 35 Store G.C. No

Instructions for Use Installation and Servicing. To be left with the user

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

23 kw wall hung combination boiler GC. No kw wall hung combination boiler GC. No

ecotec Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

Instructions for Use Installation and Servicing

Mikrofill Ethos Condensing combination boiler

Gledhill High Efficiency Condensing Boiler

Instructions for Use Installation and Servicing

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

Baxi Maxflow Combi FS

Osprey 2 CFL

Supplied by HeatingSpares247.com

Instructions for Use Installation and Servicing

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

ecotec GB, IE Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

Baxi Maxflow Combi WM

Instructions for Use Installation and Servicing

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

Instructions for Use Installation and Servicing. To be left with the user

Alpha CD13R,18R and 24R

For the installer. Instructions for installation and servicing. ecotec plus. Wall hung open vent condensing boiler

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

ecotec plus 937 Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler with 15 litre shift load power store

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Installation and Servicing Instructions. Alpha CD50

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Logic+ Combi

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Installation and Servicing Instructions

Alpha CombiMax 350 and 600

CLUB HE 18 INSTALLATION AND SERVICING INSTRUCTIONS TO BE GIVEN TO THE USER SEALED SYSTEM CONDENSING BOILER. G.C. Appliance No Club HE 18

Performa System 12e, 18e, 24e & 28e

Osprey 2 CFL

Installation and Servicing Instructions. Alpha CD24C/32C

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

ferroli Boiler Replacement Maxima 35C- Modena HE

Instructions for Use Installation and Servicing

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

USER GUIDE LOGIC HEAT H

USERS GUIDE 24, 30. For installation guide see reverse of book

Hideaway 40B G.C. No

Open Vented Condensing Boilers

Duo-tec 2 Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

CNTENTS. 1Introduction

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

INSTALLATION & TECHNICAL MANUAL

USER GUIDE VOGUE MAX SYSTEM

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Installation and Servicing Instructions. Alpha CB50

Neta-tec Plus Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Installation and Servicing Instructions. Alpha CD25C/28C/35C

Installation & Servicing Instructions

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

iheat 25c iheat 30c iheat 35c

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

VBX 18 & 30. Eden X Type INSTALLATION AND SERVICING INSTRUCTIONS OPEN VENT CONDENSING BOILER. SINGLE PAGES 20/9/10 09:58 Page 1

Alpha InTec 26C, 30C, 34C and 24X, 28X

kw Btu/h Metres Feet l/min. Gal/min C C

CLUB HE 18 INSTALLATION AND SERVICING INSTRUCTIONS SEALED SYSTEM CONDENSING BOILER TO BE GIVEN TO THE USER Pin 87/BQ/44

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Operating instructions

Installation and Servicing Instructions. Alpha CD25X/28X

EcoBlue Combi Installation and Service Manual. Gas Fired Wall Mounted Condensing Combination Boiler. Model Range (09/14)

This is a Wall Mounted Powered Flue Condensing Combination Boiler Gas Fired Central Heating Unit.

Instructions for Use Installation and Servicing. To be left with the user

Wall hung combination boiler PROTHERM 23 BTVE

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

Instructions for Use Installation and Servicing

Installation & Service Instructions Suprima HE Condensing Central Heating Boiler

60BF G.C. No

HALSTEAD Ace INSTALLATION & SERVICING INSTRUCTIONS FOR THE

Megaflo 2 System Compact GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing System Boiler

Megaflo System HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Boiler

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

System Eco Elite Range. Installation & Service Instructions

Transcription:

Instructions for Use Installation and Servicing To be left with the user 0020008154A.02.05 24cxi G.C. No. 47-047-23 12175 30cxi G.C. No. 47-047-24 38cxi G.C. No. 47-047-27 High Efficiency Condensing Combination Boilers Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT www.glow-worm.co.uk

Guarantee Registration Thank you for installing a new Glow-worm appliance in your home. Glow-worm appliances are manufactured to the very highest standard so we are pleased to offer our customers a Comprehensive Guarantee. This product is guaranteed for 24 months from the date of installation or 30 months from the date of manufacture, whichever is the shorter, for parts. In addition this product is guaranteed for 12 months from the date of installation or 18 months from the date of manufacture, whichever is the shorter, for labour. The second year of the parts guarantee, from the beginning of the 13th month onwards after installation or manufacture, is conditional upon the boiler having been serviced by a CORGI registered gas installer, in accordance with the manufacturer's recommendations. We strongly recommend regular servicing of your gas appliance, but where the condition is not met, any chargeable spare parts or components issued within the applicable guarantee period still benefit from a 12 month warranty from the date of issue by the manufacturer. We recommend you complete and return as soon as possible your guarantee registration card. If your guarantee registration card is missing you can obtain a copy or record your registration by telephoning the Glow-worm Customer Service number 01773 828100. For customer service call: 01773 828100 Technical helpline: 01773 828300 For General and Sales enquiries: Tel. 01773 824639 Fax: 01773 820569 To register your Glow-worm appliance call: 0800 073 2142 0020008154A 2

Contents The instructions consist of three parts, User, Installation and Servicing Instructions. The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be handed to the user on completion of the installation. CONTENTS DESCRIPTION SECTION PAGE No. INTRODUCTION Important Information 4 General Information 5 Manual Handling 5 INSTRUCTIONS FOR USE Appliance Safety Devices 7 Maintenance and Servicing 7 Operating the Boiler 8 INSTALLATION INSTRUCTIONS Technical Information 1 10 Boiler Location and Ventilation 2 13 Flue Location and Ventilation 3 14 Heating System 4 16 Domestic Hot Water System 5 17 Installation Preparation 6 18 Gas/Water & Appliance Connection 7 20 Safety Discharge Valve and Condensate Connection 8 21 Flue Preparation Telescopic and Standard Flue 9 23 Electrical Connection 10 26 Commissioning 11 28 SERVICING INSTRUCTIONS Servicing 12 31 Fault Finding 13 35 Replacement of Parts 14 39 Spare Parts 15 51 3 0020008154A

Important Information WARNINGS Gas Leak or Fault Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking, blowlamps, hot air guns etc. Do not operate electrical lights or switches either on or off. Open all doors and windows,ventilate the area. Sheet Metal Parts This boiler contains metal parts (components) and care should be taken when handling and cleaning, with particular regard to edges. Sealed Components Under no circumstances must the User interfere with or adjust sealed parts. Gas Category This boiler is for use only on G20 natural gas, but the 30cxi may be converted for use on G31 gas (Propane L.P.G.). Gas Safety (Installation and Use) Regulations In your own interests and that of safety, it is the Law that ALL gas appliances are installed by a competent person in accordance with the current issue of the above regulations. Testing and Certification This boiler is tested and certificated for safety and performance. It is, therefore, important that no alteration is made to the boiler, without permission, in writing, by Glowworm. Any alteration not approved by Glow-worm, could invalidate the certification, boiler warranty and may also infringe the current issue of the statutory requirements. CE Mark This boiler meets the requirements of Statutory Instrument, No. 3083 The Boiler (Efficiency) Regulations, and therefore is deemed to meet the requirements of Directive 92/42/EEC on the efficiency requirements for new hot water boilers fired with liquid or gaseous fuels. Type test for purposes of Regulation 5 certified by: Notified body 0087. Product/production certified by: Notified body 0086. The CE mark on this appliance shows compliance with: 1. Directive 90/396/EEC on the approximation of the laws of the Member States relating to appliances burning gaseous fuels. 2. Directive 73/23/EEC on the harmonisation of the Laws of the Member States relating to electrical equipment designed for use within certain voltage limits. 3. Directive 89/336/EEC on the approximation of the Laws of the Member States relating to electromagnetic compatibility. Control of Substances Hazardous to Health Under Section 6 of The Health and Safety at Work Act 1974, we are required to provide information on substances hazardous to health. The adhesives and sealants used in this appliance are cured and give no known hazard in this state. Insulation Pads / Ceramic Fibre These can cause irritation to skin, eyes and the respiratory tract. If you have a history of skin complaint you may be susceptible to irritation. High dust levels are usual only if the material is broken. Normal handling should not cause discomfort, but follow normal good hygiene and wash your hands before eating, drinking or going to the lavatory. If you do suffer irritation to the eyes or severe irritation to the skin seek medical attention. Electrical Supply The boiler must be earthed. All system components shall be of an approved type and all wiring to current I.E.E. wiring regulations. External wiring must be correctly earthed, polarised and in accordance with the relevant standards. In GB this is BS 6891. In IE this is the current edition of I.S.813 "Domestic Gas Installations". The boiler must be connected to a permanent 230V ac, 50Hz supply. Connection of the whole electrical system of the boiler, including any heating controls, to the electrical supply must be through one common isolator and must be fused 3 Amp maximum. Isolation should be by a double pole switched fused spur box, with a minimum gap of 3mm for both poles. The fused spur box should be readily accessible and preferably adjacent to the appliance. It should be identified as to its use. Alternatively connection can be made through an unswitched shuttered socket and 3A fused 3-pin plug both to the current issue of BS 1363 may be used, provided they are not used in a room containing a bath or shower. Wiring to the boiler must be PVC 85 O C insulated cable, not less than 0.75mm 2 (24/0.20mm). 0020008154A 4

General Information General Note This boiler is designed for use as part of a sealed water central heating system with fully pumped circulation. The pump, expansion vessel and associated safety devices are all fitted within the boiler. Once the controls are set the boiler operates automatically. Please read these instructions and follow them carefully for the correct installation and economical use of your boiler. Water Treatment In the case of an existing installation, it is ESSENTIAL that prior to installing the new boiler the system is thoroughly flushed. For optimum performance after installation of a new system, the boiler and its associated central heating system should also be flushed. Flushing should be carried out in accordance with BS7593: 1992 using a cleanser such as Sentinel X300 or X400, Fernox Superfloc or Salamander corrosion guard cleaner. For long-term corrosion protection, after flushing, an inhibitor suitable for stainless steel exchangers should be used, refer to the current issue of BS 5449 and BS 7593 on the use of inhibitors in central heating systems. Examples are Sentinel X100 Fernox or Salamander corrosion guard inhibitor. Compartment or Cupboard Installations If the boiler is fitted into a compartment or cupboard it does not require ventilation openings. Do not use the compartment or cupboard for storage. Condensate Drain The condensate drain, see section 8.2, must not be modified or blocked. Pluming from flue terminal Like all condensing boilers this appliance will produce a plume of condensation from the flue terminal in cool weather. This is due to the high efficiency and hence low flue gas temperature of the boiler. It is normal and not a fault indication. Cleaning The boiler casing can be cleaned using a mild liquid detergent with a damp cloth, then a dry cloth to polish. Do not use any form of abrasive or solvent cleaner as you may damage the paintwork. Electrical Supply If the mains electricity and gas are to be turned off for any long periods during severe weather, it is recommended that the whole system, including the boiler, should be drained to avoid the risk of freezing. Make sure that, if fitted, the immersion heater in the cylinder is switched off. NOTE: If you have a sealed water system contact your installation/servicing company as draining, refilling and pressurising MUST be carried out by a competent person. Clearances If fixtures are positioned close to the boiler, space must be left as shown in section 2. Enough space must also be left in front of the boiler to allow for servicing. Manual Handling IMPORTANT. With regards to the Manual Handling Operations, 1992 Regulations, the following lift operation exceeds the recommended weight for a one man lift. General recommendations when handling Clear the route before attempting the lift. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. Do not twist reposition feet instead. If 2 persons performing lift, ensure co-ordinated movements during lift. Avoid upper body/top heavy bending - do not lean forward/ sideways. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip. Always use assistance if required. Removal of carton from delivery van Recommend 2 person lift or 1 person with use of sack truck. If 1 person is performing lift, straddle the load, tilt and place carton into position on truck. Recommend secure appliance onto truck with suitable straps. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. If 2 persons performing lift, ensure coordinated movements during lift. Always use assistance if required. Carriage of carton from point of delivery to point of installation ground floor Recommend 2 person lift or 1 person with use of sack truck. If 1 person is performing lift, straddle the load, tilt and place carton into position on truck. Recommend secure appliance onto truck with suitable straps. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. If 2 persons performing lift, ensure coordinated movements during lift. Clear the route before attempting the lift. If removing boiler from truck straddle the load and tilt forwards to facilitate secure grip. Ensure safe lifting techniques are used keep back straight bend using legs. Do not twist reposition feet instead. Take care to avoid trip hazards, slippery or wet surfaces and when climbing steps and stairs. Always use assistance if required. 5 0020008154A

Manual Handling Carriage of carton from point of delivery to point of installation first or higher floor, cellar. Recommend 2-person lift or 1 person with use of sack truck. If 1 person is performing lift, straddle the load, tilt and place carton into position on truck. Recommend secure appliance onto truck with suitable straps. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. If 2 persons performing lift, ensure coordinated movements during lift. Avoid upper body/top heavy bending - do not lean forward/sideways. Clear the route before attempting the lift. If removing boiler from truck straddle the load and tilt forwards to facilitate secure grip. Ensure safe lifting techniques are used keep back straight bend using legs. Do not twist reposition feet instead. Take care to avoid trip hazards, slippery or wet surfaces and when climbing steps and stairs. Always use assistance if required. Carriage of carton from point of delivery to point of installation roofspace. Recommend 2-person lift. Ensure co-ordinated movements during lift. Avoid upper body/top heavy bending - do not lean forward/sideways. Clear the route before attempting the lift. Take care to avoid trip hazards, slippery or wet surfaces and when climbing steps and stairs. When transferring appliance into roofspace, recommend 1 person to be in roofspace to receive the appliance and other person to be below to pass up and support appliance. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. Always use assistance if required. It is assumed safe access, flooring and adequate lighting are provided in the roof space. It is recommended a risk assessment of the roof space area be carried out before moving the appliance into the area to take into account access, stability of flooring, lighting and other factors, and appropriate measures taken. Unpacking of appliance from carton. Recommend 2 persons unpack appliance from carton. Always keep working area clear. Recommend cut base end of carton and open carton flaps, then tilt boiler forwards from its side onto its base and remove carton by sliding up over the boiler. Ensure safe lifting techniques are used keep back straight bend using legs. Keep load as close to body as possible. Always use assistance if required. Dispose of packaging in a responsible manner. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip when handling appliance outside packaging. Positioning of Appliance for Final Installation no obstructions. Recommend 2 persons lift appliance to position into place. Fit bracket securely onto wall before lifting appliance into position. Obtain firm grip on front and sides of appliance, lift upwards, ensure stable balance achieved and lift upwards to position in place on bracket. Ensure safe lifting techniques are used keep back straight bend using legs - when lifting load from floor level. Do not twist reposition feet instead. Keep boiler as close as possible to body throughout lift to minimise strain on back. Ensure co-ordinated movements to ensure equal spread of weight of load. Always use assistance if required. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip when handling appliance. Positioning of Appliance for Final Installation above worktop, foreseeable obstructions etc. Recommend 2 persons lift appliance to position into place. Fit bracket securely onto wall before lifting appliance into position. Obtain firm grip on front and sides of appliance, lift upwards, onto worktop if practicable. Ensure stable balance achieved and lift upwards to position in place on bracket. If 2 persons positioning onto bracket obtain firm grip at front and sides/base of boiler. Ensure co-ordinated movements during 2 person lifts to ensure equal spread of weight of load. Ensure safe lifting techniques are used keep back straight bend using legs - when lifting load from floor level. Do not twist reposition feet instead. Keep boiler as close as possible to body throughout lift to minimise strain on back. Avoid upper body/top heavy bending - do not lean forward/sideways. Always use assistance if required. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip when handling appliance. Positioning of Appliance for Final Installation within compartment etc. restricting installation. Recommend 2 persons lift appliance to position into place, space permitting. Fit bracket securely onto wall before lifting appliance into position. Obtain firm grip on front and sides of appliance, lift upwards, onto worktop if practicable. Ensure stable balance achieved and lift upwards to drop into place onto bracket. If 2 persons positioning onto bracket obtain firm grip at front and sides/base of boiler. Ensure co-ordinated movements during 2 person lifts to ensure equal spread of weight of load. If 1 person positioning onto bracket recommend obtain firm grip supporting base of boiler. Ensure safe lifting techniques are used keep back straight bend using legs - when lifting load from floor level. Do not twist reposition feet instead. Keep boiler as close as possible to body throughout lift to minimise strain on back. Always use assistance if required. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip when handling appliance. Positioning of Appliance for Final Installation in roof space restricting installation. Recommend 2 persons lift appliance to position into place, space permitting. Fit bracket securely onto wall before lifting appliance into position. Obtain firm grip on front and sides of appliance, lift upwards, ensure stable balance achieved and lift upwards to drop into place onto bracket. If 2 persons positioning onto bracket obtain firm grip at front and sides/base of boiler. Ensure co-ordinated movements during 2 person lifts to ensure equal spread of weight of load. If 1 person positioning onto bracket recommend obtain firm grip supporting base of boiler. Ensure safe lifting techniques are used - keep back straight bend using legs - when lifting load from floor level. Do not twist reposition feet instead. Keep boiler as close as possible to body throughout lift to minimise strain on back. Always use assistance if required. Recommend wear suitable cut resistant gloves with good grip to protect against sharp edges and ensure good grip when handling appliance. It is recommended a risk assessment of the roof space area be carried out before moving the appliance into the area to take into account access, stability of flooring, lighting and other factors, and appropriate measures taken. 0020008154A 6

Appliance Safety Devices - User Instructions Electrical Supply Failure Reset Switch The boiler will not work without an electrical supply. Normal operation of the boiler should resume when the electrical supply is restored. Reset any external controls, to resume normal operation of the central heating. If the boiler does not resume normal operation turn the mains reset switch off and on. If the boiler does not resume normal operation after this the overheat stat may have operated. Overheating safety In the event of the boiler overheating the safety devices will cause a safety shutdown. If this happens, call your Installation/ Servicing company. Safety Discharge Valve A safety discharge valve and discharge pipe is fitted to the boiler. This valve must not be touched. Should there be any discharge from the pipe, isolate the boiler electrical supply and call your installer or Glow-worm s own service organisation using the telephone number on the inside front cover of this booklet. Frost protection The appliance has a built in frost protection device that protects the boiler from freezing. With the gas and electric supplies ON and irrespective of any room thermostat setting, the frost protection device will operate the pump when the temperature of the boiler water falls below 7 O C. The burner will fire if the temperature inside the boiler falls to 3 O C. When the temperature reaches 10 O C the boiler stops. Any other exposed areas of the system should be protected by a separate frost thermostat. Condensate Drain Blockage As a safety feature the boiler will stop working if the condensate drain becomes blocked. During freezing conditions this may be due to the forming of ice in the condense drain external to the house. Release an ice blockage by the use of warm cloths on the pipe. The boiler should then restart. Contact your installation/ servicing company if the fault persists. Maintenance and Servicing - User Instructions Maintenance and Servicing To ensure the continued efficient and safe operation of the appliance it is recommended that it is checked and serviced as necessary at regular intervals. The frequency of servicing will depend upon the particular installation conditions and usage, refer to guarantee registration on the inside front cover of this literature. If this appliance is installed in a rented property there is a duty of care imposed on the owner of the property by the current issue of the Gas Safety (Installation and Use) Regulations, Section 35. Servicing/maintenance should be carried out by a competent person in accordance with the rules in force in the countries of destination. To obtain service, please call your installer or Glow-worm s own service organisation using the telephone number on the inside front cover of this literature. Please be advised that the 'Benchmark' logbook should be completed by the installation engineer on completion of commissioning and servicing. All CORGI Registered Installers carry a CORGI ID card, and have a registration number. Both should be recorded in your benchmark Logbook. You can check your installer is CORGI registered by calling CORGI direct on: 01256 372300. Spare Parts Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Glow-worm. If a part is required contact Glow-worm's own service organisation using the telephone number on the inside front cover of this booklet. Please quote the name of the appliance, this infomation will be on the name badge on the front of the appliance. If in doubt seek advice from the local gas company or Glowworm's own service organisation using the telephone number on the inside front cover of this booklet. 7 0020008154A

Operating the Boiler - User Instructions CONTROLS FASCIA CONTROL LIGHT DIGITAL DISPLAY NO PRE-HEAT POSITION ECONOMY POSITION APPROX 55 O WITH PRE-HEAT 9934 MAINS RESET SWITCH CENTRAL HEATING WATER TEMPERATURE CONTROL HOT WATER TEMPERATURE CONTROL MAXIMUM POSITION APPROX 62 O WITH PRE-HEAT Diagram 1 OPERATION OF THE BOILER 1. Check that all isolating valves on the boiler are open and that water flows from the hot water tap. 2. If you are in any doubt about the boiler being filled with water contact your installer or Glow-worm's own service organisation using the telephone number on the inside front cover of this booklet. Do not operate the boiler without water. 3. Check that the electrical supply to the boiler is ON and set any remote controls as required.. 4. With the User controls in their "OFF" (0) positions, turn the Mains Reset Switch to the ON (1) position, the running lamp will initially illuminate (green) then go off, the system pressure will be displayed and should read on the digital display, at least 0.7bar (recommended 1.0bar), if less, pressurise as described in the System Pressurisation section. CENTRAL HEATING CONTROL USER CONTROLS 1. Turn the central heating water temperature control "ON", the lighting sequence will begin, the running lamp will illuminate (green) to indicate the boiler has lit, the system temperature will now be displayed instead of system pressure. The temperature of the central heating water can be adjusted by turning the central heating water temperature control to desired setting between 1 'Min' and 'Max'. Maximum setting is appoximately 82 C. Set the control to '0' to switch off heating. If the boiler fails to light, reset the controls, see paragraph below, TO RESET If a fault occurs the running lamp will flash red and a fault code will appear on the digital display. DOMESTIC HOT WATER CONTROL 2. Position 0 - hot water OFF. Turn hot water temperature control between 0 to for hot water 62 o C with no pre-heat. Turn hot water temperature control between and for hot water, 40 o C - 62 o C with pre-heat. Pre-heat is a function that provides hot water with minimum delay. The ECO setting is recommended and ideally suited to normal family use (showers, washing up etc.). Positions between ECO and are for occasional use, for water above 55 o C approx. TO RESET 3. Turn the Mains Reset Switch to 0, wait for 5 seconds, turn Mains Reset Switch to 1, the boiler is reset. If the fault persists contact your installer/service provider using the telephone number on the inside font cover of this booklet. TO TURN THE BOILER OFF 4. Turn the Mains Reset Switch to the OFF (0) position. Turn the gas supply OFF at the gas service cock if the boiler is to be out of use for some time. 0020008154A 8

Operating the Boiler - User Instructions Digital Display/ System Pressurisation The digital display normally shows the operating temperature of the unit when there is a central heating demand and gives a pressure reading when there is no demand or when the appliance is in the domestic hot water mode. If the digital display shows pressure less than 0.7bar, repressurise the system to 1bar by gently opening the built in filling tap underneath the boiler, see diagram 2. A tap extension tool is provided to facilitate this. Ensure the tap is closed. If the system repeatedly loses pressure, YOU MUST CONTACT YOUR INSTALLER OR GLOW-WORM'S OWN SERVICE ORGANISATION USING THE TELEPHONE NUMBER ON THE INSIDE FRONT COVER OF THIS BOOKLET. To Turn the Boiler Off There is a mains reset switch on the right hand side of the controls fascia, which will isolate the boiler. However, it is preferable to leave the electrical supply on whenever possible to permit operation of the built-in frost protection (see 'Protection Against Freezing') and daily pump and valve exercise. To turn off the central heating use the room thermostat or programmer. To turn off the domestic hot water turn the hot water temperature control knob to the minimum setting. For holiday mode turn both of the temperature knobs to the minimum setting. To turn off the boiler for servicing, isolate it from the electrical supply. To turn it on again follow the instructions given in 'Operation of the Boiler'. FILLING LOOP TUBE FILLING LOOP TAP AND EXTENSION TOOL 11474 Diagram 2 9 0020008154A

1 Technical Information 87 176 334 14 FLUE CENTRE LINE 12848 C L FLUE 76 C L BOILER 715 SAFETY DISCHARGE DRAIN 177 THIS DIMENSION CAN BE INCREASED TO 600mm MAX. 22 18 77 GAS 48 86 44 GENERAL ARRANGEMENT 156 134 450 Diagram 1.1 1.1 IMPORTANT NOTICE The boiler is supplied in one carton, which includes a fittings and documentation pack, see diagram 6.1. The flue and fixing jig are supplied seperately. This boiler is for use only on G20 natural gas, but the 30cxi may be converted for use on G31 gas (Propane L.P.G.). Where no British Standards exists, materials and equipment should be fit for their purpose and of suitable quality and workmanship. The installation of this boiler must be carried out by a competent person in accordance the rules in force in the countries of destination. Manufacturer's instructions must not be taken as overriding statutory requirements. 1.2 Statutory Requirements In GB the installation of the boiler must be carried out by a competent person as described in the following regulations: The manufacturer's instructions supplied. The Gas Safety (Installation and Use) Regulations. The appropriate Buildings Regulations either The Building Regulations, The Building Regulations (Scotland),The Building Regulations (Northern Ireland). The Water Fittings Regulations or Water byelaws in Scotland. The Health and Safety at Work Act, Control of Substances Hazardous to Health (COSHH). The Current I.E.E. Wiring Regulations. Where no specific instructions are given, reference should be made to the relevant British Standard Code of Practice. In IE, the installation must be carried out by a competent person and installed in accordance with the current edition of I.S.813 "Domestic Gas Installations", the current Building Regulations and reference should be made to the current ETCI rules for Electrical Installation. In GB the following Codes of Practice apply: BS4814, BS6798, BS5440 Part 1 and 2, BS5546 Part 1, BS5449, BS6891, BS6700, BS7074 Part 1 and 2, BS7593, BS7671. In IE: I.S.813, BS5546, BS 5449, BS 7074, BS 7593. Manufacturer's instructions must not be taken as overriding statutory requirements. Note: For further information, see the current issue of the Building Regulations, approved document L1 ( in the UK) and the references: 1) GIL 59, 2000: Central heating system specification (CheSS) and 2) GPG 302, 2001: Controls for domestic central heating system and hot water. BRECSU. 0020008154A 10

1 Technical Information 11976 TABLE 1 24cxi 30cxi 38cxi Lift Weight 41kg(90lb) 42kg(92.5lb) 44kg(97lb) Total Weight (installed) 44kg(97lb) 45kg(99lb) 47kg(103.5lb) Gas connection Heating and return Domestic hot water Rc 1 / 2 ( 1 / 2 in BSPT) 22mm copper 15mm copper Safety valve Preset 3bar (43.5lbf/in 2 ) Safety valve discharge 15mm copper Expansion vessel capacity 8 litres (1.76 gallons) Charge pressure 0.5bar (7.3lbf/in 2 ) 11979 Heating system 0.7bar (10.1lbf/in 2 ) minimum pressure D.H.W Max. working pressure 10bar (145lbf/in 2 ) Minimum working pressure for max. domestic flow rate 0.2bar (2.9lbf/in 2 ) Max. Domestic hot water flow rate at 35 O C rise 24 cxi 9.8L/min. 30 cxi 12.3L/min. 38 cxi 15.5L/min. Min. Domestic hot water flow rate 24/30/38cxi 1L/min. Maximum flow temperature 63 0 C 11603 Maximum heating system 130 litres water content using (28.6 gallons) pressurised at 1bar. fitted expansion vessel, at 75 0 C average system temperature Electrical supply Electrical rating IP classification Internal Fuse rating On PCB 230V~50Hz 180W fused 3A X4D 630mAT Ball valves are fitted in water and gas connections. For larger systems use an additional expansion vessel. Diagram 1.2 11 0020008154A

1 Technical Information Certification This boiler certificated to the current issue of EN 483 : 2000 for performance and safety. It is important that no alteration is made to the boiler, without permission, in writing, from Glow-worm. Any alteration that is not approved by Glow-worm, could invalidate the warranty and could also infringe the current issue of the Statutory Requirements. 9165 1.3 Gas Supply The gas installation must be in accordance with the relevant standards. In GB this is BS6891. In IE this is the current edition of I.S.813 "Domestic Gas Installations". The supply from the governed meter must be of adequate size to provide a steady inlet working pressure of 20mbar (8in wg) at the boiler. On completion, test the gas installation for soundness using the pressure drop method and suitable leak detection fluid, purge in accordance with the above standard. 1.4 Technical Data All dimensions are given in millimetres (except as noted). See diagrams 1.1 and Tables 1 and 2. The data label is positioned on the inner door, refer to diagram 1.2. The Seasonal Efficiency Domestic Boilers UK (SEDBUK) is Class 'A' : 24cxi - 90.3%, 30cxi - 90.3% & 38cxi - 90.6%. The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from which it has been calculated has been certified by B.S.I. 1.5 Condensate Drain A plastic drain pipe must be fitted to allow discharge of condensate to a drain. Condensate should, if possible, be discharged into the internal household draining system. If this is not practical, discharge can be made externally into the household drainage system or a purpose designed soak away, see section 8.2 for more details. 1.6 Vertical Plumbing Kits Where the domestic hot water and heating flow and return pipes come from above the boiler or just the heating flow and return pipes, vertical plumbing kits are available to facilitate this. Central Heating only, part No. 2000460477 Central Heating and DHW, part No. 2000460468 Contact Glow-worm for further details. 1.7 Optional Programmer Kit An optional programmer for fitting in the boiler is available, Pt. no. 2000458065. SCHEMATIC LAYOUT OF BOILER BURNER %CO 2 APPROXIMATE GAS RATE (after 10 mins. from cold) BURNER %CO 2 APPROXIMATE GAS RATE (after 10 mins. from cold) BURNER %CO 2 APPROXIMATE GAS RATE (after 10 mins. from cold) TABLE 2 30 cxi Diagram 1.3 Case Off 9.1 +0.2-0.5 Case On 9.3 +0.3-0.5 MIN MAX m 3 /h 0.48 2.8 ft 3 /h 24 cxi Case Off 9.1 +0.2-0.5 Case On 9.3 +0.3-0.5 MIN MAX m 3 /h 0.48 2.24 ft 3 /h 38 cxi 16.8 79 16.8 99 Case Off 8.8 +0.2-0.5 Case On 9.0 +0.3-0.5 MIN MAX m 3 /h 0.62 3.6 ft 3 /h 21.8 127 0020008154A 12

2 Boiler Location and Ventilation 2.1 Location This boiler is not suitable for outdoor installation. This boiler may be installed in any room, although particular attention is drawn to the installation of a boiler in a room containing a bath or shower where reference must be made to the relevant requirements. In GB this is the current I.E.E. WIRING REGULATIONS and BUILDING REGULATIONS. In IE reference should be made to the current edition of I.S.813 "Domestic Gas Installations" and the current ETCI rules. 2.2 Clearances The boiler should be positioned so that at least the minimum operational and servicing clearances are provided, see diagram 2.1. Additional clearances may be beneficial around the boiler for installation and servicing. For flue installations where external access is not practicable, consideration should be given for the space required to insert the flue internally, which may necessitate clearance larger than those specified in diagram 2.1. 2.3 Timber Frame Buildings If the boiler is to be installed in a timber frame building it should be fitted in accordance with the Institute of Gas Engineers document IGE/UP/7/1998. If in doubt seek advice from the local gas undertaking or Glow-worm. 2.4 Room Ventilation The boiler is room sealed, so when it is installed in a room or space, a permanent air vent is not required. 2.5 Cupboard or Compartment Ventilation Due to the high efficiency and hence low casing temperature of this boiler, cupboard or compartment ventilation is not necessary. Leave existing air vents. 5 5 600 + 5 150 20 20 200 12344 + A removable compartment door can be placed at least 5mm in front of the appliance. MINIMUM CLEARANCE FROM PERMANENT SURFACES Diagram 2.1 13 0020008154A

3 Flue Location and Ventilation 3.1 Flue Options This boiler is suitable for concentric Horizontal and Vertical flues, elevated horizontal and vertical twin, all are fitted onto the top of the boiler. The Glow-worm Flue Options Guide, available on request or through the web site, describes in detail the necessary accessories. These instructions describe the use of the standard and telescopic horizontal flues. The instructions for all other flues will be contained in those packs. 3.2 Flue Length The maximum permissable horizontal flue length is 10 metres plus the flue terminal, this can be achieved by use of the accessories, however should additional 90 o or 2 x 45 o elbows be used then the length MUST be reduced by 1metre. When extension pipes are used the flue system must be designed to have a continuous fall to the boiler of at least 2.5 o 44mm/metre to allow condensate to run back into the boiler and out via the drain. The flue can be installed from inside the building, when access to the outside wall face is not practicable. The diagrams 3.1 to 3.4 describe the lengths achievable without the use of extensions or elbows. 75 min. to 540 max. WALL THICKNESS 12839 208 min. to 413 max. WALL THICKNESS 12837 87min 112 87min 112 176 176 OUTSIDE WALL FACE BOILER MOUNTING WALL OUTSIDE WALL FACE BOILER MOUNTING WALL NOTE. If necessary, it is permitted to increase this dimension to 600mm max. TOP REAR FLUE - STANDARD NOTE. If necessary, it is permitted to increase this dimension to 600mm max. Diagram 3.1 TOP REAR FLUE - TELESCOPIC Diagram 3.3 87min NOTE. If necessary, it is permitted to increase this dimension to 600mm max. Max flue length 717mm 12840 87min NOTE. If necessary, it is permitted to increase this dimension to 600mm max. Max flue length 589mm 12838 20mm min. clearance 239 211 20mm min. clearance 239 211 A CL FLUE A CL FLUE OUTSIDE WALL FACE INTERNAL SURFACE Max. distance from outside wall face to min clearance. LH - 458mm RH - 486mm TOP SIDE FLUE - STANDARD A Min. distance from outside wall face to min clearance. LH/RH - 75mm OUTSIDE WALL FACE INTERNAL SURFACE Max. distance from outside wall face to min clearance. LH - 330mm RH - 358mm Diagram 3.2 TOP SIDE FLUE - TELESCOPIC Diagram 3.4 A Min. distance from outside wall face to min clearance. LH - 125mm RH - 153mm 0020008154A 14

3 Flue Location and Ventilation MINIMUM SITING DIMENSIONS FOR FANNED FLUE TERMINALS POSITION MM HORIZONTAL FLUES A DIRECTLY BELOW AN OPENING, AIR BRICK, OPENING WINDOWS 300 B ABOVE AN OPENING, AIR BRICK, OPENING WINDOWS 300 C HORIZONTALLY TO AN OPENING, AIR BRICK, OPENING WINDOWS 300 D BELOW GUTTER, DRAIN/SOIL PIPE 25 E BELOW EAVES 25 F BELOW A BALCONY OR CAR PORT 25 G FROM VERTICAL DRAIN PIPES AND SOIL PIPES 25 H FROM INTERNAL/EXTERNAL CORNERS 25 H* TO A BOUNDARY ALONGSIDE THE TERMINAL 300 I ABOVE ADJACENT GROUND OR BALCONY LEVEL 300 J* FROM SURFACE OR A BOUNDARY FACING THE TERMINAL 600 K FACING TERMINALS 1200 L FROM OPENING (DOOR/WINDOW) IN CAR PORT INTO DWELLING 1200 M VERTICAL FROM A TERMINAL 1500 N HORIZONTALLY FROM A TERMINAL 300 3.4 Terminal Position The minimum acceptable siting dimensions for the terminal from obstructions, other terminals and ventilation openings are shown in diagram 3.5. For Ireland the minimum distances for flue terminal positioning must be those detailed in I.S.813 "Domestic Gas Installations". The terminal must be exposed to the external air, allowing free passage of air across it at all times. Being a condensing boiler some pluming may occur from the flue outlet. This should be taken into consideration when selecting the position for the terminal. H* and J* See diagram 3.5. These dimensions comply with the building regulations, but they may need to be increased to avoid wall staining and nuisance from pluming depending on site conditions. Increased siting flexibility can be achieved by using the Glowworm Plume Management Kit, A2044000 (black) or A2044100 (white). NOTE: If necessary it is permitted to increase the terminal protrusion through the outside wall to greater than the minimum dimension of 87mm but no more than 600mm, see diagram 1.1. Carports or similar extensions of a roof only, or a roof and one wall, require special consideration with respect to any openings, doors, vents or windows under the roof. Care is required to protect the roof if made of plastic sheeting. If the carport comprises of a roof and two or more walls, seek advice from the local gas supply company before installing the boiler. H* and J* See diagram 3.5. These dimensions comply with the building regulations, but they may need to be increased to avoid wall staining and nuisance from pluming depending on site conditions. 3.5 Terminal Guard A terminal guard is required if persons could come into contact with the terminal or the terminal could be subject to damage. If a terminal guard is required, it must be positioned to provide minimum of 50mm clearance from any part of the terminal and be central over the terminal. The guard should be similar to that shown in diagram 3.6. A suitable guard is manufactured by: - Tower Flue Components Morley Rd. Tonbridge Kent TN9 1RA. Size: 280mm x 280mm x 270mm. TERMINAL GUARD VERTICAL FLUES P FROM ANOTHER TERMINAL 600 Q ABOVE ROOF LEVEL 300 R FROM ADJACENT OPENING WINDOW 1000 S FROM ADJACENT WALL TO FLUE 300 Diagram 3.5 Diagram 3.6 15 0020008154A

4 Heating System 4.1 General The boiler is for use only with sealed central heating systems. The safety valve is an integral part of the boiler and it cannot be adjusted. The digital readout on the controls fascia indicates the system pressure when there is no central heating demand. The circulation pump is integral with the boiler. 4.2 Expansion Vessel The boiler has an integral expansion vessel with a capacity of 8 litres (1.76 gallons), with a charge pressure of 0.5bar. NOTE: The expansion vessel volume depends on the total water system volume and the initial system design pressure. Guidance on vessel sizing is also given in the current issue of BS5449 and BS7074 Part 1, for IE refer to the current edition of I.S.813 "Domestic Gas Installations". MODEL Table 3. Flow Rate MINIMUM FLOW RATE 24 cxi 774 litres/hr. 30 cxi 1032 litres/hr. 38 cxi 1289 litres/hr. 9168 This is equal to 20 O C differential at maximum heat input. 4.3 Flow Rate If it is necessary to alter the flow rate, the system can be fitted with a lockable balancing valve in the main flow or return pipes shown as valve "A" in diagram 4.1. The flow rate through the boiler must not be allowed to fall below that given in table 3. 4.4 Bypass The boiler is fitted with an adjustable automatic bypass. Ensure that under no circumstances does the flow rate drop below the figure specified, refer to table 3 and section 11.6. The installation of the boiler must comply with the requirements of the current issue of BS6798, in Ireland, refer also to the current edition of I.S.813 "Domestic Gas Installations". In GB it is necessary to comply with the Water Supply (Water Fittings) Regulations 1999 (for Scotland, the Water Byelaws 2000, Scotland). To comply with the Water regulations your attention is drawn to: The Water Regulations guide published by the Water Regulations Advisory Service (WRAS) gives full details of the requirements. In IE the requirements given in the current edition of I.S.813 "Domestic Gas Installations" and the current Building Regulations must be followed. 4.5 Filling the Sealed System NOTE: The water pressure at the boiler must be at least 1.2bar to enable filling the boiler to a minimum pressure. If not pressurisation must be carried out by an alternative filling loop. The boiler has a built in filling device, see diagram 4.2. A pushon extension is supplied in the loose items pack to ease access to the filling device tap. This filling device is designed to enable the re-pressurisation of the system in the event of loss of pressure. It is not intended to be used to completely fill the system. If so used, it may take a long time to fill the system. To fill the system quickly provision should be made to include a proprietry filling loop external to the boiler. Suitable external filling systems are shown diagramatically, see diagram 4.3. The system should be pressurized to 1 bar, indicated on the digital display with no heating demand. 11474 FILLING LOOP REDUCED TAP PRESSURE FILLING LOOP TAP * Refer to section 11.6 Diagram 4.1 ZONE VALVE EXTENSION Diagram 4.2 0020008154A 16

4 Heating System 4.6 Water Treatment In the case of an existing installation, it is ESSENTIAL that prior to installing the new boiler the system is thoroughly flushed. For optimum performance after installation of a new system, the boiler and its associated central heating system should also be flushed. Flushing should be carried out in accordance with BS7593: 1992 using a cleanser such as Sentinel X300 or X400, Fernox Superfloc or Salamander corrosion guard cleaner. For long-term corrosion protection, after flushing, an inhibitor suitable for stainless steel exchangers should be used, refer to the current issue of BS 5449 and BS 7593 on the use of inhibitors in central heating systems. Examples are Sentinel X100 Fernox or Salamander corrosion guard inhibitor. 12253 4.7 Draining Tap A draining tap must be provided at the lowest points of the system, which will allow the entire system to be drained. A drain tap for the appliance is provided as an integral part of the hydroblock, see diagram 12.12. Diagram 4.3 5 Domestic Hot Water System General - All domestic hot water circuits, connections, fittings must be in accordance with the relevant standards and water supply regulations. For GB: Guidance G17 to G24 and recommendation R17 to R24 of the Water Regulations Guide. For IE: The current edition of I.S.813 "Domestic Gas Installations". 5.1 Water Pressure The maximum working pressure of the domestic hot water circuit is 10 bar. If the cold water supply pressure exceeds this, then a pressure-reducing valve must be fitted in the supply to the boiler. 5.2 'Hard' Water Areas The temperatures within the heat exchanger are limited by the boiler control system to minimise scale formation within the hot water pipework. However, in areas where the water is 'hard' (i.e. more than 200mg/litre), it is recommended that the hot water setting is reduced and that a scale reducer is fitted. Refer to the manufacturer's instructions or consult the local water company for additional advice. 5.3 Domestic Water Flow Rate The water flow rate is restricted to a maximum 8 l/min (24cxi) 12 l/min (30cxi) and15.5 l/min (38cxi) by a restrictor fitted during boiler installation, see diagram 7.1. 17 0020008154A

6 Installation Preparation 6.1 Appliance Pack IMPORTANT: With regards to the Health and Safety Manual Handling requirements, two persons shall be required to lift the appliance, refer to Manual Handling section on page 5. Please check the contents of packs as shown in diagram 6.1. NOTE: The fittings pack is located in the base polystyrene packing under the boiler base. Remove the polystyrene end packing pieces then carefully lay the boiler on its back, remove the two front casing panel securing screws and lift off the panel from two retaining lugs. Remove the transit packaging behind the front panel and discard. Carefully place front panel and screws to one side. 12332 Diagram 6.1 0020008154A 18

6 Installation Preparation 6.2 Wall Template Take the wall template from the fixing jig pack and place in the desired position on a flat wall, giving due consideration to boiler clearances, see section 2, and the flue you are fitting. 2.5 44mm/metre Inclined Extended flue length 176 12075 6.3 Flue Hole Cutting The standard horizontal flue is designed with an internal fall of 44mm/metre towards the boiler for disposal of condensate. If the standard flue length alone is being used then the flue hole of diameter 105mm can be cut in the position marked on the wall template. For standard side flues the horizontal flue centre line on the wall template should be extended to the side wall, and the vertical centre of the flue hole marked at 176mm from the back wall. For installations with external access, a 105mm diameter core drill can be used. For installations with internal access only a 125mm diameter core drill should be used. When using extension pipes with the horizontal rear flue, a core drill size of 125mm should be used to allow the extension pieces to slope at 44mm/metre (2.5 ) towards the boiler. For extended side flues, the flue hole centre should be determined by extending the dashed inclined line on the template to the side wall. This dashed line is drawn at 44mm/metre (2.5 o ) rise from the boiler. Where this line reaches the side wall, a horizontal line should be marked. The vertical centre line of the flue should then be marked at 176mm from the back wall, see diagram 6.2. To allow for the flue passing through the wall at this angle a 125mm hole should be drilled irrespective of internal or external installation. Remove the wall template whilst drilling the flue hole. 6.4 Fixing Jig and Hanging Bracket Reposition the wall template over the flue hole and mark the position of the fixing holes for the jig and the hanging bracket, see diagram 6.3. Drill the four fixing holes, 2 for the hanging bracket and 1 each for the top hole of the fixing jig wall brackets and insert suitable wall plugs. If gas and/or water pipes are to be connected through the rear wall, the holes must be drilled as marked on the wall template prior to securing the fixing jig. Secure the fixing jig wall brackets to the wall using suitable screws. NOTE: Due to the varied site conditions we do not supply fixings and advise that the installer should supply those which are suitable. Locate the jig plate between the wall brackets and secure with the No. 8 self tapping fixing screws supplied in the fittings pack. 2.5 2.5 16 130 130 EXTENDED SIDE FLUE WALL TEMPLATE HANGING BRACKET SCREW WALL PLUG SCREW (2 OFF) 127 Standard flue length Horizontal WALL TEMPLATE 90 Ø 125 Diagram 6.2 WALL PLUG 12049 SCREW FIXING JIG PLATE FIXING JIG WALL BRACKETS (2 OFF) (Handed as shown) Diagram 6.3 19 0020008154A

7 Gas/Water & Appliance Connection 7.1 System Connection The system can now be connected without the boiler being mounted. All water and gas connections are on the fixing jig with the exception of the condense drain and safety discharge, the positions of these are shown on the wall template. The gas supply pipe must be chased into the wall if routed up the back of the boiler. A Vertical Plumbing Kit can be used to route the central heating or DHW pipes, see section 1.6. Make connections to fixing jig, gas, water and heating cocks with the tube assemblies supplied in fixing pack as shown in diagram 7.1. 7.2 Gas Connection Before connection check supply of local gas. Refer also to section 1.2. Do not subject the gas service cock to heat. Fit the sealing washer into the union nut and make good the connection to the gas service cock on the wall fixing jig, see diagram 7.1. Make sure the on / off lever is accessible. The whole of the gas installation, including the meter, should be inspected, tested for soundness and purged in accordance with the current issue of BS6891 and in IE the current edition of I.S.813 "Domestic Gas Installations". 7.3 Water Connections Flush out the domestic hot water and the heating systems before connecting to the boiler. Make the connections to the domestic hot water and heating systems by fitting the sealing washers into the securing nuts and make good the connection to the isolating valves on the fixing jig, see diagram 7.1. Do not subject the isolation valves to heat. Make sure the drain point is accessible, refer diagram 12.11. 7.4 Appliance Connection IMPORTANT: With regards to the Manual Handling Operations, 1992 Regulations, the following lift operation exceeds the recommended weight for a one man lift, refer to Manual Handling section, on page 5. The appliance will contain a small amount of water, place a water container beneath the boiler connections before removing the protective caps. Position gasket/sealing washers and cold water inlet flow restrictor supplied in the fittings pack, as shown in diagram 7.1. Lifting the boiler into position, lean the top of the boiler slightly to the wall and position just above the hanging bracket. Lower the boiler slowly and engage onto the hanging bracket. Pivot the boiler to engage the fixing jig connections, ensuring that the previously positioned washers /gaskets and DHW flow restrictor are not disturbed, see diagram 7.1. Make good the final connections. 12349 C A B D A ALL ISOLATION VALVES ARE SHOWN IN CLOSED POSITION 12347 Diagram 7.1 0020008154A 20