Distributed*and*installed*in*the*UK*by*

Similar documents
VEDOLUX ROBUST GREEN WOOD-FIRED BOILERS

Wood firing at its simplest

Installation and maintenance Vedolux 450

Wood-firing at its simplest

Installation and maintenance Vedolux 350


Combine. accumulators AQUALUX ACKTANK. Combine heat sources for cheap heating

VÄRMEBARONEN IS A UNIQUE COMPANY IN THE ENERGY INDUSTRY

Installation, operation and care Firewood boiler Vedolux 40 UB

Wood pellets economical and environmentally friendly. Wood pellet heating

Pellet heating. Boilers & Burners.

Solar heating. Free heat from the sun!

Installation, operation and maintenance. Accumulator tank. Acc-tank 500 CU. Acc-tank 500 UB ver: Supersedes:

Installation, operation and care. Pellmax UB. Burner not included Replaces:

Product catalogue. Our range of products for bungalows

Combined boiler. for solid fuel and pellets

Heating with wood chips

BIOMASS BOILER ATTACK PELLET 30 AUTOMATIC PLUS

PE1 Pellet. PE1 Pellet. Pellet boiler - Canada. PE1 Pellet APPROVED FOR EPA 2020 EMISSION LIMITS.

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Accumulator tank. 1000, 750 and 500 litres Aqualux Teknik Aqualux UB Aqualux 750 CU

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Installation and maintenance Viking Bio 35 - pellet burner

HERZ ECO-Line Heating with logs or wood pellets

English. Heating with logs & wood pellets 20-40

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

Installation, operation and care. Pellet burner Replaces:

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

Heating with log wood

PZ35RL BIOTECH THE FUTURE OF HEATING PZ 35 RL

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

modern heating devices

Installation and maintenance Viking Bio 35 - pellet burner

Eco Angus Wood Pellet Boilers

Providing sustainable energy solutions worldwide. CTC heating boilers modern technology, efficient heating

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

S3 Turbo Firewood boiler. S3 Turbo AVAILABLE WITH BROADBAND LAMBDA PROBE AND SERVO-MOTORS.

CITY OPEN - CITY BOX from 25 to 35 kw

New opportunities to heat with wood pellets

Biomass. Biomass solid fuel boiler range

Log fired heating system

Forward-looking and energy effi cient Biomass heating

Heating with pellets kw

Installation instruction

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Boiler Technical Specifications (2013)

INSTALLATION AND OPERATING INSTRUCTIONS

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

Olymp Werk GmbH c/o Grouped Renewables Ltd. PO Box 7180, Montrose DD10 0WX Tel: +44 (0) Web:

Pioneers of heating with biomasses

Installation, operation and maintenance. Pellet burner 18/01/2011. Replaces:

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Installation instruction

Efficient heating that won t cost the earth

Flexible heating system without limits.

natural warmth of the house A compact boiler designed to combust ecological fuel- pellet ORLIGNO 500 Compliant with EN norm

Heating with wood chips & pellets

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

RIELLO 40 GS/M SERIES

SWEBO Bioenergy Manual pellet burner PB50 Rev no. Date Page PBM1: (37) Installation and maintenance instructions

DUX WATER HEATERS HOT WATER SOLUTIONS PRODUCT GUIDE

The Difference Is Quality

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 400

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Heating with wood pellets kw

Your guide to. Biomass Heating Systems

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Fully water jacketed secondary chamber with stainless steel afterburner

FIREPLACE INSERTS AND STOVES THE FIRE COMPANY

Smart Heating Technology Ltd. U Statku 653/24, Ostrava-Bartovice Czech Republic

WOOD BOILER SWEDISH MADE V202KUB

Biomass Pellet Boilers

DUX WATER HEATERS GAS HOT WATER SOLUTIONS. Bunnings can replace your old hot water system and install a new one fast!

Harlequin HeatStream Case Study

JÄSPI Solid Fuel Boiler

PELLET BURNER PV 350

Leading European manufacturer of fireplace stoves and fireplace inserts. Fireplace inserts

Fireplace inserts Water heating fireplace inserts Fireplace door

From a renowned company

Forced draught gas burner

Operating Instructions

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

English. Heating with logs & wood pellets 20-40

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

SWEBO Bioenergy Manual pellet burner PB20 Rev no. Date Page PBM1: (36) Installation and maintenance instructions

GB The King of Comfort

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

Multi Fuel Heating Solutions for Every Home. A Cast Iron Masterpiece

Dux Water Heaters CLICK TO START

Sweden s leading air source heat pump

LOG BURNING BOILERS. Zeroridge Biomass Ed 17A

EKO Line Pellet Boiler Wood Pellet Storage Solutions And Pellet Dosage Systems

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Solid fuel expertise.

Home CALOR. At with INTRODUCING OUR NEW TUMBLE DRYER SAFETY AT HOME

Importance of a Draught Regulator

Transcription:

Distributed*and*installed*in*the*UK*by* www.biofutures.co.uk*

VEDOLUX ROBUST GREEN WOOD-FIRED BOILERS

WOOD BOILERS MADE IN SWEDEN Firing with wood is by far the cheapest way of heating your house. The Vedolux Lambda range makes it cheaper and easier than ever. Vedolux makes maintenance and handling easier for you. The clear display tells you what is going on in the boiler and guides you at the start. If you insert too much wood or poor quality wood, the boiler ensures that the output is adjusted so that the firing continues to be efficient and green. Hatch locks ensure that you cannot open the hatches by mistake. Lambda control ensures that the wood lasts for a long time and minimum soot is created. This saves you a lot of work both on the wood and on boiler maintenance. Sweeping and ignition are simple, and take just a few minutes. The boilers are very robust. Thick cover plates and solid buttons and handles that are durable. You need not worry about anything breaking for a while. All the products in the catalogue are designed and made in our own factory in Sweden.

LAMBDA FOR THE FUTURE AND FOR THE ENVIRONMENT Vedolux 350, 450 and 650 all have Lambda control. The principle is the same as in modern cars. The car's fuel economy and exhaust gas purification efficiency depend on the lambda value. Tests at SP, the Technical Research Institute of Sweden, show that both the efficiency and environmental values of Vedolux boilers are in a class of their own and the boilers thus meet strict emission requirements. LAMBDA ALSO SAVES TIME AND WORK Lambda has the pleasant side-effect of saving you a lot of work. The high efficiency level of 93% ensures that you get as much heat as possible out of your wood. This means less time chopping wood and more time for leisure activities. It also means longer intervals between firings. The fact that the boilers are very easy to sweep saves you further time and work.

ROBUST Its timeless design has gained the Vedolux range a great deal of attention at plumbing and heating fairs worldwide. But the Vedolux is not just a delight for the eye. Tests at SP, the Technical Research Institute of Sweden, show that both the ENVIRONMENT: Class 5 Best class according ENstandard 303-5:2012. efficiency and environmental values of Vedolux boilers are in a class of their own. The unique design of the Vedolux means that it suits both confirmed wood firers and those who are looking for the best modern wood-fired boiler on the market. The design and construction of the boilers produce unparalleled efficiency and ensure that the wood lasts a long time and EFFICIENCY: 93% the intervals between firings are long. Vedolux is a genuine quality product in all respects: steel quality, control, service and support. QUALITY DOWN TO THE SMALLEST DETAIL SWEDISH DESIGN SUCCESS VVS-Forum no. 4 2011 Handle Grate Display Tested by SP Vedolux Lambda comply with the highest demand according standard 303-5:2012. Test was performed by the Technical Research Institute of Sweden. A number of other boilers are available in addition to the Vedolux Lambda. Värmebaronen has a wide range. Order our wood-firing catalogue.

RIGHT OUTPUT FOR RIGHT HOUSE PRODUCES BEST ECONOMY Firing with wood is by far the cheapest way of heating. If you choose a boiler with the right output, it becomes even cheaper. Therefore, we have developed several Vedolux models with different output levels. This makes it easy to choose the right boiler for the right house. Vedolux is available in outputs from 35 kw up to 65 kw. ³. of error, while the environmental requirements are still met. The Vedolux 650 resembles an exclusive retro-style fridge painted matt black. This colour should, by definition, be the optimum colour for a wood-fired boiler VVS-Forum no. 4 2011 Sweep and ignite the boiler in five minutes: All sweeping takes place from the front through just one hatch. The round flues have no hidden corners or folds in which ash and soot can collect. You can easily withdraw the turbulators from the boiler by hand. No tools are required. The soot collects in the base of the boiler and is simply raked out in the retractable ash drawer. Insert the wood through the good-sized hatch and then light it with the LPG ignition supplied. It could not be easier.

AQUALUX CHOOSE THE RIGHT ACCUMULATOR FOR YOUR VEDOLUX By choosing a Vedolux wood-fired boiler, you are making a particularly good choice. In terms of handling and the environment and with 93% efficiency, Vedolux is ahead of its competitors. Then it is important to make an equally good choice when you choose the accumulator. AQUALUX TEKNIK ACCUMULATORS Aqualux Teknik is the best choice if you are thinking of combining your wood firing with solar panels now or in the future. Aqualux Teknik has up to 25 times the stratification-retaining properties of a standard tank. The buffer capacity is 15-20% higher than a good coil tank. Thanks to unique functions such as diffusers, Aqualux Teknik maintains its position as the leading accumulator on the market. Three different sizes to choose from. Vedolux with Aqualux Teknik accumulators Order our catalogue on combining heating. It contains all the information you need to read to understand how important it is to choose a really good accumulator tank.

ABOUT WOOD Wood firing need not be any more difficult than you make it. Some people like to collect their own wood and enjoy spending time in the forest. Others get together with neighbours and use machinery. This makes the job really fast and easy. If you want to make things even easier for yourself, you can buy split wood. Whichever approach you take, wood firing is always the cheapest way to heat your house. Ready-split wood ABOUT SOLAR POWER Solar panels have become popular. Then there is no need to fire your boiler throughout the warm half of the year. The sun takes care of your hot water from April to September. Order our catalogue! K2 solar panel K2 SOLFÅNGARSYSTEM

Vedolux 350 RSK 622 20 03 Overview 9 10 11 19 20 21 22 1 1452 0/+20 815 234 620 2 2 3 4 Minimum distance between rear of boiler and wall is 250 mm. 1. Flue pipe connection. 2. Cooling coil, DN 15. 28 29 30 31 32 23. Bypass damper. Weight empty 478 kg Flue pipe 24. Wood filling/soot hatch. full of water 620 kg 25. Latch, wood filling hatch. Standard Flue pipe upwards, accessory 26. Ash hatch. Water volume 140 litre n147 inv. 331 147 int. 220 643 27. Latch, ash hatch. Fuel: Wood length 500 mm 28. Opening for LPG ignition. Wood store volume 100 litre 29. Back-pressure damper, primary. 30. Motor/damper, primary air. depth 550 mm 145 220 31. Motor/damper, secondary air. Filling hatch w x h 350 x 265 mm 535 348 32. Back-pressure damper, secondary. Power nominal 35.8 kw 625 626 33. Flue gas temperature sensor. Chimney requirements height 5 m 34. O2 probe. draught -0.15 mbar 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. diameter 150 mm 37. Supply, 230 V~, charging pump. Accumulator volume min. 1500 litre 38. Fan. Emissions - comply with EN-standard 303-5:2012. 16 Subject to printing and proofreading errors Subject to printing and proofreading errors 17 142 175 1245 5 6 4 1434 0/+20 160 1025 8 7 4 7 127 1440 0/+20 205 12 13 14 15 16 17 18 3. Expansion connection/safety valve/rp 1. 4. Return from accumulator tank/drain, Rp 1 1/4. 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/4. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. Upper flue gas tubes, 4, with turbulators. 12. Lower flue gas tubes, 4, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 14. Bypass plate. 15. Air plates, detachable. 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 33 34 35 36 37 38 23 24 25 26 27

Vedolux 450 RSK 622 20 04 Overview 9 10 11 19 20 21 22 12 23 1652-0/+20 1633-0/+20 160 1639-0/+20 13 14 15 16 17 18 24 25 1 2 3 4 815 Flue pipe Standard 233 619 220 643 5 6 Flue pipe upwards, accessory 1. Flue pipe connection. 2. Cooling coil, DN 15. 3. Expansion connection/safety valve/rp 1. 4. Return from accumulator tank/drain, Rp 1 1/4. 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/4. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. Upper flue gas tubes, 4, with turbulators. 12. Lower flue gas tubes, 4, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 14. Bypass plate. 15. Air plates, detachable. 28 29 30 31 32 33 34 35 36 37 Weight empty 560 kg full of water 730 kg Water volume 170 litre Fuel: Wood length 500 mm Wood store volume 140 litre 29. Back-pressure damper, primary. 30. Motor/damper, primary air. depth 550 mm 31. Motor/damper, secondary air. Filling hatch w x h 350 x 325 mm 535 257 285.5 285,5 32. Back-pressure damper, secondary. Power nominal 47 kw 625 626 33. Flue gas temperature sensor. Chimney requirements height 5 m 34. O2 probe. draught -0.15 mbar 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. diameter 150 mm 37. Supply, 230 V~, charging pump. Accumulator volume min. 3000 litre 38. Fan. Emissions - comply with EN-standard 303-5:2012. 18 Subject to printing and proofreading errors Subject to printing and proofreading errors 19 142 175 1245 2 4 8 1025 7 4 7 Minimum distance between rear of boiler and wall is 250 mm. 204 70 177.8 n177,8 3 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 23. Bypass damper. 24. Wood filling/soot hatch. 25. Latch, wood filling hatch. 26. Ash hatch. 27. Latch, ash hatch. 28. Opening for LPG ignition. 38 26 27

Vedolux 650 RSK 622 20 05 Overview 9 10 11 19 20 21 22 23 Flue pipe Standard 1. Flue pipe connection. 2. Cooling coil, DN 15. 3. Expansion connection/safety valve/rp 1. 4. Return from accumulator tank/drain, Rp 1 1/4. Weight empty 730 kg full of water 930 kg Water volume 200 litre Fuel: Wood length 500 mm Wood store volume 200 litre 257 643 29. Back-pressure damper, primary. depth 550 mm 30. Motor/damper, primary air. 31. Motor/damper, secondary air. Filling hatch w x h 400 x 420 mm 257 285.5 285,5 32. Back-pressure damper, secondary. Power nominal 65 kw 493 33. Flue gas temperature sensor. Chimney requirements height 5 m 626 34. O2 probe. draught -0.15 mbar 35. Mains connection, 230 V~. 36. Supply, 230 V~, flue gas fan. diameter 180 mm 37. Supply, 230 V~, charging pump. Accumulator volume min. 3500 litre 38. Fan. Emissions - comply with EN-standard 303-5:2012. 20 Subject to printing and proofreading errors Subject to printing and proofreading errors 21 154 1 814 260 666 1800 0/+20 2 2 3 4 257 144 243 643 1245 5 6 4 160 8 1025 7 4 7 Flue pipe upwards, accessory 204 70 1790 0/+20 Minimum distance between rear of boiler and wall is 250 mm. 177.8 177,8 3 12 13 14 15 16 17 18 5. Connection, sensor for thermal valve (STW), Rp 1/2. 6. Flow line to accumulator tank, Rp 1 1/4. Can be used as lifting sleeve. 7. Adjustable foot bolts. 8. Drain, Rp 1/2. 9. Boiler temperature sensor (inside electronics box). 10. Box with boiler's electronics. 11. Upper flue gas tubes, 4, with turbulators. 12. Lower flue gas tubes, 4, with turbulators. 13. Resetting the max. temperature thermal relay (STB). 14. Bypass plate. 15. Air plates, detachable. 16. Wood store. 17. Grate. 18. Ceramics. 19. Rear cover plate, detachable. 20. Front cover plate, detachable. 21. Display/control panel. 22. Soot hatch. 23. Bypass damper. 24. Wood filling/soot hatch. 25. Latch, wood filling hatch. 26. Ash hatch. 27. Latch, ash hatch. 28. Opening for LPG ignition. 28 29 30 31 32 33 34 35 36 37 38 24 25 26 27

Arkelstorpsvägen 88 SE-291 94 Kristianstad Tel. 044-22 63 20, fax 044-22 63 58 email: info@varmebaronen.se www.varmebaronen.se

Distributed*and*installed*in*the*UK*by* Biofutures*Ltd* The*Biomass*Centre* Taliaris* Llandeilo* Carmarthenshire* SA19*7NF* * 01558*824100* info@biofutures.co.uk* www.biofutures.co.uk*