Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Similar documents
A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES

Sensitivity to Thoron on Passive Radon Detectors

Radon and Thoron Measurements at Special Underground Circumstances

ASSESSEMENT OF INDOOR RADON, THORON AND THEIR PROGENY IN DWELLINGS OF BAREILLY CITY OF NORTHERN INDIA USING TRACK ETCH DETECTORS

A new personal dosemeter for the individual monitoring of exposure to radon gas

RADON SURVEY IN KALAMATA (GREECE) Medicine, London SW7 2AZ U.K. Greece. Republic

A new passive integrating detector for measurement of individual radon exposure at working places.

Development of high sensitivity radon detectors

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Assessment of Radon-222 Concentrations in Buildinps, Building Materials, Water and Soil in Jordan

MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) *

CURRENT INDOOR RADON SITUATION IN LITHUANIA

Relevant Radon properties

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania

Spatial variation of radon concentration in a room ZHANG ZHENGGUO*, XIAO DETAO**, ZHANG LIANG*, LI CHUNXIU*,

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

CR-39 SAMPLING OF INDOOR RADON IN SOUTHERN ROMANIA *

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Electronic Personal Dosemeter

THE NATIONAL RADON SURVEY IN IRELAND. S.G. Fennell, G.M. Mackin, J.S. Madden and A.T. McGarry

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

Environmental Radiation Monitoring System

Radon in elementary schools in Tunisia

Measurement system for detection of Radon in building

Outdoor radon concentration in China

adsw worth Center, New York State Department of Health, Albany, NY 12201

THE RELIABILITY OF RADON REDUCTION TECHNIQUES. CB Howarth

Dynamic Radon Detection Over Measurement

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Effect of Contamination on the Sensitivity of Optical Scatter Smoke Sensors

Radon in thermal waters and radon risk in chosen thermal water spas in V4 countries - preliminary results

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Ionisation Chambers Containing Boron as Neutron Detectors in Mixed Radiation Fields

Quality and Technology - Made in Germany -

Importance of standardization for decommissioning

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Radiation Environment on ISS in April 2013 According the Data from Liulin-5 Particle Telescope

Detectors used in the intercomparison

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Radon Measurements in Argentina

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

Guide for Radon Measurements in Residential Dwellings (Homes)

Radiation Monitoring Equipment

Measurement Devices. Topic 5 - Audio 56

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

International Requirements for the Control of Radon

THERMAL HYDRAULIC PHENOMENOLOGY FOR THE HEATING PROCESS IN A NATURAL CIRCULATION FACILITY

Radon in (Greek) workplaces GREECE

Original Research Higher Levels of Radon Affect Women's Fertility in Iraqi Kurdistan

Radiation Emitting Devices Research X-ray Safety Program

RESIDENTIAL RADON CONCENTRATIONS IN KATHMANDU VALLEY USING SOLID STATE NUCLEAR TRACK DETECTORS. Dinesh Thapa and Buddha Ram Shah

THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Sergey Kiselev. SRC Federal Medical Biophysical Center

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

Radon Detection Specialists, Inc.

Texas active target (TexAT) detector part 1: Design and construction progress

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

Indoor radon survey in Shiraz-Iran using developed passive measurement method

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

RADIATION PROTECTION PROPERTIES OF ADDITIONAL SHIELDING «PROTECTIVE CURTAIN» INSTALLED IN CREW CABIN OF RUSSIAN SEGMENT OF ISS

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

W.E.T. (Water Extraction Techniques) Lab

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL

Portable Survey Instruments NISP-RP-01

A CONTINUOUS RADON MONITORING SYSTEM BASED ON A SOLID- STATE SILICON DETECTOR

Urethral alarm probe for permanent prostate implants

PH.D. THESIS (SUMMARY)

Radon Detection Specialists, Inc.

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Optimization of Sensitivity Characteristics of Photoelectric Smoke Detector to Various Smokes

Key-Words: - PIR detector, simulation, temperature fields, temperature radiation, heating sensor. Fig. 1 Principle of PIR detector

A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Designing and construction of a new radon calibration facility in Romania

To investigate the surface properties for increasing efficiency of solar water heater

University of Bristol - Explore Bristol Research. Peer reviewed version. Link to publication record in Explore Bristol Research PDF-document

EC - RADON Latest strategies and draft regulations

Numerical study of heat pipe application in heat recovery systems

CHAPTER 3 RADIATION PRODUCING DEVICES I. AUTHORIZATION TO USE RADIATION PRODUCING DEVICES

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Radon Basics for Building Officials PATRICK DANIELS IEMA RADON PROGRAM

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

National and Regional Surveys of Radon Concentration in Dwellings

Radon Entry Dynamics with Alpha Track Monitors or Just How Does the Radon Get In?

INTERNATIONAL STANDARD

Keywords: VEWFD; Smoke detection; Smoke production; In-situ testing.

Transcription:

International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 1 Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement Murtadha S. Al-Nafiey,* Mohamad S. Jaafar,* Sabar Bin Bauk,** N.F. Salih* *Radiation and Medical Physics, School of Physics, Universiti Sanis Malaysia **School of Distance Education, Universiti Sanis Malaysia Abstract- This study consists of two parts: the first part is concerned with designing a new radon chamber that is constructed using a continuous radon monitor together CR-39 Nuclear Track Detectors (NTDs). The aim behind designing such a chamber is to measure radon at different times. The chamber has a cubic shape and it is made of pixy glass with a volume of 0.125. The solid radium 226 source with an activity 5 was placed at the bottom of the chamber to generate radon. The result has shown that the track density increased when increasing the exposure time to radon and the latter's homogenous concentration inside the chamber until it reached 38.377 ± 20 kbq. Second, the calibration factor for radon has been measured using CR-39 NTDs. Besides, PVC was used to calculate the calibration factor k. The values of the calibration factor for radon was 0.024 ± 0.004 ( per ) under three parameters, temperature, humidity and efficiency; accordingly the values were as such 27 ± 1, 57 ± 5 RH ; 80 % respectively.the study further revealed that the best PVC chamber that detects and measures the real value of airborne radon concentration is 237.67. Keywords: Chamber Design; Calibration Factor; CR-39; Radon Monitor; Radon Email: murtadhababylon@gmail.com * 1. Introduction The public exposure to radon and to its radioactive daughters present in the environment largely contributes to the average effective dose received by human beings [1]. The international recommendation of the annual dose of the natural radiation obtained from the public is 1 msv [2]. Radon is an alpha emitted with energy of 5.49 Mev with a half life of 3.8 days. As a common alpha particle, it is characterized by being relatively heavy and positively charged. Therefore, all the radiation energy will be absorbed in very small volume of matter immediately. Several techniques have been used to measure radon and its daughters in this area. One of these techniques is the solid state nuclear track detectors SSNTDs. Such a technique has been increasingly used in passive time integrated modes to measure the radon and thoron present in the environmental medium [3, 4]. In fact, this work includes two main parts: the first part is dedicated to design a cubic-shaped chamber that is made of pixy glass and under three parameters. The latter, embed temperature, humidity and the speed of the flux inside the chamber. It further aims at measuring the concentration of radon by using a continuous radon monitor. The second part is concerned with designing and constructing PVC chambers radon dosimeter via estimating the optimum volume of the dosimeters. Such a step helps measure the calibration factor of radon. The calibration factor was determined through the following expression [5]: k = (1) where k is the calibration factor ( per ); c is the standard radon concentration ( ); ρ is the track density ); and t is the exposure time (d). 2. Radon chamber design A new radon chamber was designed and fabricated in the Medical Physics at the School of Physics, Universiti Sains Malaysia. The chamber is cubic in shape and is made in laboratory. Its dimensions are (50 cm 50 cm 50 cm). Fig. 1 showcases two photos of the chamber and its continuous radon monitor. It further clarifies most of the following described features: The chamber consists of four openings. The first opening is located at the top and it is of the size (15 cm, 15 cm). This opening is used to put materials

International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 2 inside the chamber. The second and third openings are opposite to one another. They are fitted with a thick rubber glove to manoeuvre things inside the chamber and to turn on and off the continuous radon monitor and printing the results. The fourth opening is adjusted to join the power supply for the detector. Furthermore, a fan is fitted to provide the internal air circulation needed inside the chamber. The fifth groups of CR-39 are sized (10 15 0.50) mm 3, produced by the Track Analysis Systems Ltd., Napier House, Meadow Grove, Bristol, and (BS11 9PJ, UK). All these pieces were placed inside the chamber. PVC chamber was designed with a different volume for each detector, as shown in Fig. 2. The radium source ( ; 5 ) was used to obtain radon gas. In this study, the experimental conditions inside the chamber were properly under a controlled climate. The radon exhalation rate can be calculated by referring to the following climatic conditions each time: the relative humidity, which is 57 ± 5 RH and temperature, which is 27 ± 1. The continuous radon monitor was placed in SNC calibration camber, using a radon chamber of the US Department of Energy, Environmental Measurement Laboratory. Fig. 1.The radon chamber and the continuous radon monitor model (1023) Fig. 2. Homemade radon diffusion chamber 3. Measuring the Concentration of Radon Activity In order to determine the concentration of the radon activity inside the chamber, a continuous radon monitor was calibrated from the company. Such work has continued for two month and every 91.2 h, one has to register the results for each hour. Furthermore, the fifth groups of CR-39 were performed inside the PVC at different exposure times and different levels of exposure. This step has been achieved by controlling the hole in the tap of PVC by placing it differently inside the camber. Such a process helps measure the homogeneity of the radon inside the chamber. Figures 3 and 4 shows the track densities against the exposure time. They further showcase six photos of the track

Average Track Denssity (Track / cm2 International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 3 densities with different times. Figures 3 and 4 also show how the track density increased when increasing the exposure time. The results were then compared with other researches, and were found identical [3].The average radon concentration was determined to be 38. 377 ± 20 kbq. All the detectors were treated under etching conditions with water-bath and an optical microscope connected to a computer was used to count and measure the track density. Fig.3. The track densities with different times exposure radon 6000 5000 4000 3000 2000 y = 69.705x + 372.46 R² = 0.9376 1000 0 0 20 40 60 80 Exposur Time (day) Fig. 4. The track densities against the exposure time 4. Measuring Radon Homogeneity Homogeneity of radon inside the chamber was tested using the fifth groups CR-39 detectors. These CR-39 groups were arranged inside the chamber differently and in accordance with the position of the fan. The distribution of radon inside the chamber was uniform and its homogeneity might be considered acceptable as the differences were less than 10. It should also be noted that the average track densities observed, (around 3500 ± 10 track/ ), were not affected by the exposure circumstances. Fig. 5 shows the average track densities in relation to the different locations of the detector.

Average Track Density (track / cm2) International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 4 3500 3400 3300 3200 3100 3000 1 2 3 4 5 6 7 8 9 10 11 Distance from the source Ra ( cm ) Fig. 5. The track densities with the locations of the detector inside the chamber 4. Measuring the Calibration Factor (k) The calibration process of the CR-39 was very important in radon detection. The efficiency was measured because the latter was affected by the time of storage. The efficiency the detector was calculated using the radium source. Under these etching conditions, the calculated efficiency (η) was 80, using the following formula: η = 1 sin (Ɵc) (2) where Ɵc is the critical angle; and are the bulk and track etch rates, respectively. The calibration measured under the etching conditions was 6.25 N NaOH 70 [6, 7], using the optimum time of etching, 6 h. To determine the calibration factor, equation 1 was used. The fifth groups of CR-39 were performed with different volumes of PVC. They were then put inside the radon chamber for 91.2 h. It was noted that the calibration factor for radon detection depended on the geometric of its dosimeter. Besides, the emitted alpha particles located at a distance more than 8 cm has revealed that the dosimeters does not affect the detectors at least in this height - 10 cm with different diameters [8]. For this purpose, the fifth groups were listed as follows: (1) Group one were exposed with the PVC volume 34.64 and with (10 and 2.1 (2) Group two were exposed with the PVC volume 96.25 and with (10 and 3.5 (3) Group three were exposed with the PVC volume 159.1 and with (10 and 4.5 (4) Group four were exposed with the PVC volume 237.67 and with (10 and 5.5 (5) Group five were exposed with the PVC volume 331.96 and with (10 and 6.5 All detectors were etched and counted using the same condition described earlier. The optimum values for the calibration factor was (0.024 0.004 ( per.d) at an optimum volume that equals 237.67, as shown in Fig. 6. Table 1 depicts the values of calibration factor presented in this paper which agrees with the previous obtained results [9, 10, 11, and 12].

K( track.cm2/bq. m3 International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 5 0.026 0.024 0.022 0.02 0.018 0.016 0.014 0.012 0.01 0 50 100 150 200 250 300 350 V( cm3) Fig.6. Calibrating as the dosimeter volume. 5. Conclusions A new chamber fitted with many features was designed and fabricated to enable the calibration of radon measurement. Controlling the temperature, humidity and many other parameters was achieved. The track densities were noted to increase with increase in radon concentration. The concentration of radon measured inside the chamber was 38.377 ± 20 kbq. The calibration factor was 0.024 ± 0.004 ( per.d) at 80 efficiency. Besides, the optimum volume in this study was 237.67. This work was in line with the previously conducted studies in the same field of knowledge. Acknowledgments This study was supported by the School of Physics in Universiti Sains Malaysia. Table: 1Comparison results between present work and other references Calibration factor References Details of exposure 0.0027± 0.0004 [9 ] - 0.05 [10] Placed in a cup with polyethylene lid inside FRED 0.028 [11] Aerosol load provided to simulate dwelling condition 0.02 [12] Place in a plastic cup with special rubber membrane and exposed in a radon chamber 0.024 Present study PVC chamber inside the chamber cubic and exposure time of radon References [1] United Nations Scientific Committee on the Effects of Atomic Radiations UNSCEAR Sources and effects of ionizing radiation. UN, New York, 1982. [2] A.D.Wrixon, New ICRP recommendations.journal of Radiological Protection, 28, 161-168, 2008. [3] R. Shweikani, G. Raja, Design, construct and test of a calibration radon chamber, Radiat. Meas. 40, 316-319, 2005. [4] D. Nikezic H., K.N. Yu, Computer program TRACK-TEST for calculation parameters and plotting profiles for etch pits in nuclear track materials, Comput. Phys. Commun. 174, 60, 2006.

International Journal of Scientific & Engineering Research, Volume 3, Issue 10, October-2012 6 [5] Y. S. Mayya, K. P. Eappen, K. S. V. Nambi, Methodology for mixed field inhalation dosimetry in monazite areas using a twin-cup dosimeter with three track detectors, Rad. Prot. Dosim., 77(3), pp.177-184, 1998. [6] Gil Hoon Ahn, Jai-Kilee, Construction of an environmental radon monitoring system using CR- 39 nuclear track detectors, Nucl.Eng. Technol.37 (4) 395-400, 2005. [7] M. I. Al-Jarallah, Fazal-ur-Rehman, Khalid Abdalla, Comparative study of short and long-term indoor radon measurements, Radiat.Measure.43, S471-S474, 2008. [8] A. H. Ismail, Mohamad S. Jaafar, Design and construct optimum dosimeter to detect airborne radon and thoron gas: Experimental study, Nucl. Instr. and Meth. In Phys. Res. B269, 437-439, 2011. [9] Marcia Pires de Campos and Elaine Wirney Martins, Calibration of the solid state nuclear track detector CR-39 for radon measurements. INAC International Nuclear Atlantic Conference Santos, SP, Brazil, ASSOCIAÇÃO BRASILEIRA DE ENERGIA NUCLEAR ABEN. ISBN: 978-85- 99141-02-1, 2007. [10] J. C. H.Miles and E. J. Dew, A passive radon gas detector for use in homes. In Solid State Nuclear Track Detectors (Edited by Fowler P. H. and Clapham V. M.). Pergamon Press, Oxford, 1982. [11] M. C Subba Ramu., T. S. Murlidharan and T. V. Ramachandran, Calibration of a solid state nuclear track detector for the measurement of indoor levels of radon and its daughters. Sci. Total Environ. 73, 245-255, 1988. [12] J.Giridhar and M.Raghavayya, Calibration of cellulose nitrate film for measurement of time integrated concentration of Rn-222 in air. Report No. 1319, BARC, Bombay, 1986.