Detectors used in the intercomparison

Similar documents
Intercomparison s working group:

Quality and Technology - Made in Germany -

Designing and construction of a new radon calibration facility in Romania

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

A new passive integrating detector for measurement of individual radon exposure at working places.

MetroRADON project and its potential impact on mitigation practices Dobromir Pressyanov Sofia University St. Kliment Ohridski Bulgaria

Sensitivity to Thoron on Passive Radon Detectors

Introduction...1 Specifications... 1 Limitations... 1

Development of high sensitivity radon detectors

Radiation Monitoring Equipment

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Measurement Devices. Topic 5 - Audio 56

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

INTERNATIONAL INTERCOMPARISON EXERCISE ON NATURAL RADIATION MEASUREMENTS UNDER FIELD CONDITIONS (IFC11) *

A new personal dosemeter for the individual monitoring of exposure to radon gas

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Ramon 2.2 Radon-Monitor

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

Use of MCNPX for Alpha Spectrometry Simulations of a Continuous Air Monitor

Dynamic Radon Detection Over Measurement

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

A distributed network of sensors for real-time remote control of radioactivity and radiation

A study of Indoor Radon / Thoron Levels in Some Dwellings by using Solid State Nuclear Track Detectors

Radon in thermal waters and radon risk in chosen thermal water spas in V4 countries - preliminary results

Měření difúze, ultranízké koncentrace a emanace radonu pro podzemní laboratoř

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Ultraviolet radiation detector to obtain the rate of particles at different heights

RTM / & 01/ / RTM

National Radon Action Plan and Radon Database

Radon and Thoron Measurements at Special Underground Circumstances

Environmental, Pollution & Security Monitoring. Radiation Protection & Nuclear Security. Radon, Thoron, Daughter Products & Radioactive Aerosols

Radon Reference Facility at Bowser-Morner, Inc. AMUG Meeting Las Vegas May 4, 2010 Phillip H. Jenkins, PhD, CHP

Radon monitoring system in the Kamioka mine

EFFECTS OF SMALL PRESSURE DIFFERENCES BETWEEN THE STRUCTURE AND SURROUNDINGS ON RADON ENTRY

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

ENVIRONMENTAL RADON MONITORING IN DWELLINGS NEAR THE RADIOACTIVE SITES

HISTORY OF SOIL-GAS RADON CONCENTRATION MEASUREMENTS IN THE CZECH REPUBLIC

THE EFFECT OF VENTILATION AND FILTRATION ON RADON DECAY PRODUCT MEASUREMENTS

1 SCOPE 2 OVERVIEW 3 NORMATIVE REFERENCES

Environmental radioactivity surveillance system of ANPA

Canberra icam: the worldwide alpha/beta air monitoring solution. James Forde-Johnston EMS Product Manager Japan User Group Meeting

their original bags during the test period determine what background reading they might accumulate. The actual

Measurement system for detection of Radon in building

Design and Fabrication of New Radon Chamber for Radon Calibration Factor of Measurement

Sergey Kiselev. SRC Federal Medical Biophysical Center

INTERNATIONAL INTERCOMPARISON EXERCISE OF ACTIVE RADON DEVICES AND PASSIVE DETECTORS AT THE FIRST EAST EUROPEAN RADON SYMPOSIUM (FERAS 2012)

Radon in (Greek) workplaces GREECE

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

Radon Entry Dynamics with Alpha Track Monitors or Just How Does the Radon Get In?

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

laboratories radiation. presence disturb radon as results. Measurements of the influence of radon on a that 30 Bq m-3, system using a that generates

Radon Measurements at Australian Antarctic Stations

Results of the 2012 HPA Intercomparison of Passive Radon Detectors

Abstract. Introduction/Background. New Radon guideline for Canada

Application Note. Application Note for BAYEX

Evaluation of radon survey, setting a national reference level

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

Situation on Radon Assessment in Latvia

Performance Requirements for Monitoring Pulsed, Mixed Radiation Fields Around High-Energy Accelerators

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Guide for Radon Measurements in Residential Dwellings (Homes)

W.E.T. (Water Extraction Techniques) Lab

Radon Environmental Health Program Health Canada, Alberta Region. Bradley Hameister October 4, 2011

European Commission approach with regard to radon

C-NRPP Quality Control and Quality Assurance Manual for Radon Sampling and Analysis conducted by Radon Measurement Professionals and Laboratories

C-NRPP Quality Assurance Guidance for Radon Test Devices

Using downhole probing for real-time grade estimation for uranium exploration and mining

METHODOLGY FOR RADON PRESENCE INVESTIGATION IN MINE GALLERIES. CASE STUDY: BĂIŢA BIHOR REPOSITORY

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

ß-Aerosolmonitor FHT 59 C

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Battery-operated, hand-held alarm and measuring instruments for radiation protection

CURRENT INDOOR RADON SITUATION IN LITHUANIA

SEASONAL VARIATION OF RADON CONCENTRATION - MEASUREMENTS IN SOME EUROPEAN COUNTRIES

Baseline radon detectors for shipboard use: Development and deployment in the First Aerosol Characterization Experiment (ACE 1)

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

2.18 Air Sampling Equipment RCT Study Guide Identify the factors that affect the operator's selection of an air sampling system.

AC, AT, LS Measurement Devices

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

International Requirements for the Control of Radon

ASSESSEMENT OF INDOOR RADON, THORON AND THEIR PROGENY IN DWELLINGS OF BAREILLY CITY OF NORTHERN INDIA USING TRACK ETCH DETECTORS

SP-3800AA Atomic Absorption Spectrophotometer

Importance of standardization for decommissioning

RADPAR: Radon Prevention and Remediation ( )

RADON CONCENTRATIONS AFFECTED BY DIFFERENT FACTORS IN TWO OFFICE BUILDINGS. Raimo Halonen, Pirjo Korhonen, Pentti Kalliokoski and Helmi Kokotti

Development of the Groundwater Radon Detector

Portable Survey Instruments NISP-RP-01

Radon Testing Results. City Hall

Assessment of factors causing false alarm signals from detection equipment, and ways to mitigate this challenge

RADON SURVEY IN KALAMATA (GREECE) Medicine, London SW7 2AZ U.K. Greece. Republic

A CONTINUOUS RADON MONITORING SYSTEM BASED ON A SOLID- STATE SILICON DETECTOR

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

Underground Air Radon Monitoring First Experiment

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

National and Regional Surveys of Radon Concentration in Dwellings

ABSTRACT FOR AARST CONFERENCE OCTOBER 1990 INSTRUMENTATION FOR RADON MEASUREMENT AND DIAGNOSIS

Transcription:

Detectors used in the intercomparison The second radon-in-field international intercomparison for passive measurement devices: dwellings and workplaces 21 22 september 2017 Campus Bovisa Politecnico di Milano Milan (ITALY) M. Faure Ragani - Environmental Protection Agency of Aosta Valley Region www.arpa.vda.it Intercomparison s working group: Filippo Berlier, Francesco Cardellini, Enrico Chiaberto, Daniele Giuffrida, Massimo Faure Ragani, Federica Leonardi, Mauro Magnoni, Gianfranco Minchillo, Anna Prandstatter, Elena Serena, Rosabianca Trevisi, Rosamaria Tripodi, Stefania Verdelocco, Miriam Veschetti

The measurement campaigns S1: low radon concentrations and 5 months of exposition (office); S2: medium radon concentrations and 5 months of exposition (storage room); S3: high radon concentrations and 9 days of exposition in a mixed radon/ thoron atmosphere (cellar).

The detectors In order to achieve a complete characterization of the three sites we have to: provide the three reference values of Rn concentration/exposure; evaluate the possible radon concentration inhomogeneity; evaluate the Thoron presence / influence in the Rn/Th mixed atmosphere exposure evaluate the equilibrium factor (spot for the long exposures and average for the mixed Rn/Th exposure) 26 continuous radon monitors used in field Intercomparison of active instruments

The detectors 5 ALPHAGUARD, pulse-counting ionization chamber, Saphymo Gmbh, Germany 1 NG ALPHAGUARD, pulse-counting ionization chamber, Saphymo Gmbh, Germany 11 RADIM 5B, semiconductor detector, Jiry Plch, Czech Republic 1 THORON SCOUT, semiconductor detector, SARAD Gmbh, Germany 1 EQF 3220, semiconductor detector, SARAD Gmbh, Germany 5 Lucas Cells monitors, alpha scintillation chamber, MI.AM S.r.l, Italy 1 AER+, semiconductor detector, Algade-Dosirad, France 1 Corentium Pro, semiconductor detector, AirThings, Norway Reference and comparison instruments

The detectors Radon 5 Alphaguard 11 Radim 5B 5 Lucas cells 1 AER+ 1 Corentium pro Operational modes: Integration time: 1h Radon Thoron 1 Thoron scout 1 NG Alphaguard 1 EQF3220 Radon and progeny 1 EQF 3220 Sampling: diffusion 10 min: NG Alphaguard in flow: EQF 3220 1.5 l/min, NG Alphaguard 2 l/min, 1 MR1 Lucas cell 0.4 l/min

The detectors background Radon concentrations are low (S1,S2) instruments background is very important The steps we followed: ARPA Piedmont Radon Chamber: exposure to N 2 CESNEF Radon Chamber: exposure to N 2 and air with low radon concentration ENEA INMRI Radon Chamber: exposure to radon-free air of selected detectors best estimate of detectors background

The detectors background Decision threshold Detection limits

The detectors calibration The initial situation Rn Th Rn progeny 1 not calibrated 11 Internal certificates (performed by the owners) 10 Company certificates 1 Accredited laboratory certificate 3 Primary body certificates (ENEA-INMRI) 10 certificates during 2016-2017 1 certificate during 2015 14 certificates older than 5 years 3 Company certificates (2017) 1 Company certificate (2017)

The detectors calibration The step we followed: Rn ARPA Piedmont Radon Chamber CESNEF Radon Chamber ENEA INMRI Radon Chamber initial situation first intercalibration reference exposure for calibration of selected detectors Th ENEA INMRI Thoron Chamber ARPA Piedmont Radon Chamber first Thoron measurements Radon / Thoron mixture measurements Rn progeny ENEA INMRI PAEC measurements comparison of 2 instruments

Initial situation @ CESNEF 40% 20%

The calibration @ CESNEF 3 steps calibration: very high concentrations low/medium exposures Step1 Step2 Step3 38000 14000 8000 Bq/m3 1400 500 300 kbqh/m3 7%

The calibration The final calibration factors (after exposure @ ENEA-INMRI of selected detectors) Sometimes: CF 1 CF depending on the concentration Calibration function? Extrapolation at low concentrations?

Radon / Thoron mixed atmosphere Aims: correct measurement of Radon concentration in presence of Thoron evaluation of Thoron influence on continuous Radon monitors measurement of Thoron concentration (?) instrument calibration for Thoron (?) Instruments: 1 Thoron Scout, semiconductor detector, diffusion mode 1 EQF3220, semiconductor detector, flow mode 1 NG Alphaguard, pulse-counting ionization chamber, flow mode 1 MR2, Lucas Cell with Thoron cycle used in radon chamber only

Radon / Thoron mixed atmosphere Radon Thoron

Radon/Thoron mixed atmosphere: instrumental techniques for continuous measurements α spectrum Th spectrum during the first hours Th spectrum in the activity equilibrium Po 218 Bi 212 Po 216 Po 214 Po 212 tailing Po 216 tailing Po 212 Po 214 tailing Po 212 Bi 212 β decay 6 MeV 6.8 MeV 7.7 MeV 8.8 MeV α energy Spectrum after Th exposure Rn spectrum in equilibrium state Thoron Scout - EQF 3220 Rn Fast Rn Slow

Radon/Thoron mixed atmosphere: instrumental techniques for continuous measurements Delayed coincidences method Time interval distributions between the events ( Time spectrum of alpha decays) MR2 flow mode (30 min cycle) only Th by now Double counting interval method It makes use of the difference in half lives of Rn and Th NG Alphaguard flow mode (10 min cycle) Rn+Th Rn Pump on Counting on Pump off Counting off Pump off Counting on

Thoron measurements ENEA - INMRI 3.6 l/min 3.6 l/min Thoron source MR1 EQF - 1.5 l/min Thoron source MR1 AG 1.9 l/min Reference value : 20169 Bq/m 3 ± 5% Measured value EQF: 27000 Bq/m 3 ± 4% Measured value AG: 30465 Bq/m 3 ± 15% Difference from reference: 34% (CF: 0,75) Difference from reference: 51% (CF: 0,66)

Thoron measurements ENEA - INMRI V 1 Thoron source 3.6 l/min MR1 V 2 EQF Reference value in V 1 : 20169 Bq/m 3 ± 5% Calculated value in V 2 : 6454 Bq/m 3 ± 5% Measured value in V 2 : 7801 Bq/m 3 ± 11% 21 % diff We have to improve hardware configuration in order to be sure about the Th uniformity in V 2

Radon / Thoron mixed atmosphere ARPA Radon Chamber Th + Rn Th Rn Rn concentration (Bq/m 3 ) Th + Rn Rn Δ AG 268 202 66±25 Radim 405 190 215±60

Radon / Thoron mixed atmosphere α spectrum - EQF Th Th + Rn Rn ROI Tailing and overlapping correction ROI

Radon / Thoron mixed atmosphere α spectrum - EQF Th Th + Rn Rn

Radon / Thoron mixed atmosphere ARPA Radon Chamber Th Th + Rn Rn Th concentration (Bq/m 3 ) Th Th+Rn All period Tscout 813 740 (91%) 760±151 EQF 939 821(87%) 853±100 MR2 675 630(93%) 645±127 No changes in Rn concentration

Radon / Thoron mixed atmosphere Sensitivity to Thoron Concentration (Bq/m 3 ) AG 66±25 Sensitivity (s) Δ Rn (Th) Th Th/Rn Δ Rn (Th)/Th 0.09±0.04 753±74 4 Radim 215±60 0.29±0.11 Open questions: s is depending on the specific instruments? s is depending on Th/Rn ratio? s is depending on environmental parameters? In S3 site we decided to set up a Rn measurement configuration with Th free atmosphere: MR1 in flow mode with 50 m of pipe in the inlet, in order to achieve complete Th decay In bibliography for Alphaguard: AG s info Michielsen et al. [2015] Sumesh et al. [2012] Kochowska et al. [2009] Ishikawa [2004] 0.09±0.04 Different instruments Rn free atm 0.11±0.04 0.06-0.08 Low Rn conc 0.07-0.12 Low Rn conc 0.08-0.17 Th/Rn 4 0.03-0.07 0.04-0.06 0.04-0.07 Radon free atmosphere Different Th concentration 0.09-0.14 Rn free atm 0.07 Th/Rn 1:1

Radon PAEC: the instruments EQF 3220 SARAD ARPA BWLM-PLUS-2S - TRACERLAB ENEA - INMRI mesh filter EEC for attached, unattached and cluster Radon and Thoron daughter products PAEC for attached and unattached Radon and Thoron daughter products PAEC = (Mev/l) 4 j=1 n j E j = 4 j=1 λ j n j E j λ j = 4 j=1 c j E j λ j j=1,2,3,4 Po218, Pb214, Bi214, Po214 n = number of atoms per unit of volume c = activity concentration E j = PAE λj= decay constant EEC = PAEC k e k e =34735 Mev/Bq

Radon PAEC: the walk-in chamber Measurements at ENEA INMRI radon walk-in chamber : 150 m 3 Depression system (ΔP = 1 mbar) Natural emanation of radon

Radon PAEC Measurements at ENEA INMRI:

Radon PAEC Measurements at ENEA INMRI radon walk-in chamber : 1.56 0.90

Conclusions Good exercise to understand instruments behaviour: Long measurement campaigns Rn/Th mixed atmosphere exposure In chamber intercomparison In field intercomparison Background measurements PAEC measurements Metrological critical aspects (references, calibrations ).

Thank you