Technical data sheet TDS0034

Similar documents
Technical data sheet TDS0060

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

PREMIER PLATINUM INFRARED GAS SENSOR

CO2 Carbon Dioxide Sensor

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Key Features. General Description

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

IR25 Dual Gas Series Datasheet

IR15 Dual Gas Series Datasheet

IR1 Single Gas Series Datasheet

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

VQ500 Series Combustible Gas Detector Elements

Integrated IR Datasheet

MICROpeL 75 Combustible Gas Sensor Part Number: PM

IRceL CH4 Methane (CH 4

Lamp Supply (Recommended)

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

Dräger Polytron Pulsar 2 Open Path Gas Detector

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

Model D12-IR. Digital Gas Transmitter...

P R O D U C T D ATA S H E E T

Dräger PIR 3000 Detection of flammable gases and vapours

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Dräger X-am 2500 Multi-Gas Detection

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron SE Ex Fixed Gas Detector

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

GAS PLUS ALARM SYSTEM

SIMRAD GD10PE IR GAS DETECTOR

ULTIMA X5000. MSAX5000.com

SIMRAD GD10 IR GAS DETECTOR

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

INSTRUCTION MANUAL (ATEX / IECEx)

4) Intrinsic Safety Certification

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

THE BELGIAN PIONEER IN GAS DETECTION

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

S5000 Gas Monitor. GMS5000.com

Dräger X-am 5000 Multi-Gas Detection

TX6351 TX6352 Sentro 1 Universal Gas Detector Contents

Hydrocarbon Gas Detector

APPLICATION DATA SHEET

GasAlertMicroClip X3 Specifications

Combustible Gas Detection and Control System

Dräger X-am 5000 Multi-Gas Detection

Dräger Polytron 8000 Stationary gas detector (EC)

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

CO warning instruments and gas spillage detectors

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

SprintIR -W CO2 Sensor

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

GX-2009 Portable Gas Monitor Operator s Manual

VQ600 Series Combustible Gas Sensing Head

Module Features are-configurable, no module jumpers to set

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Danfoss gas detection units

INSTRUCTION MANUAL (ATEX / IECEx)

Safe Operation Manual. Honeywell IQ Force Gas Detector

Datasheet: K-22 LO Sensor

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Carbon Monoxide Transmitter

SEC Signature Process Gas Analyzer

P R O D U C T D ATA S H E E T

FIRERAY 5000 range USER GUIDE

Dräger X-am 7000 Multi-Gas Detection

Relays for use in hazardous locations. Class I, Division 2 and ATEX

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

Dräger X-am 2500 Multi-Gas Detector

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger PIR 7000 Flammable Gas Detection

IREX Pellistor exchange IR gas detector

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

PTE0705 Electric Fence Monitor

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Model 144H. Product Data Sheet , Rev DB February Content

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

02/11/2015

Dräger PEX 3000 Flammable Gas Detection

ESD3000IR ESD3000IR. Infrared Gas Detector

Transcription:

Technical data sheet TDS0034 PREMIER HYDROCARBON INFRARED SENSOR CERTIFIED VERSIONS TYPES MSH-P-HC and MSHia-P-HC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending France EP [ FR ] 1544603 Germany EP [ DE ] 1544603 Italy EP [ I ] I1544603 Switzerland EP [ CH ]1544603 USA 7, 244, 939 Other World Patents Pending FEATURES Contains all the necessary optics, electronics and firmware to provide a linearized, temperature-compensated output. Choice of output format direct pellistor replacement, industry standard 0.4 to 2 volts dc or digital. Instantly converts existing compatible pellistor-based instruments to infrared. Large range of gas calibration options available, e.g. methane, propane, butane etc. Sensors can be factory configured to customer specification. All sensor types are user configurable using configuration equipment available from Dynament. Fast track route for original equipment manufacturers to introduce the latest infrared technology without any specialist knowledge. Internal Flash memory allowing sensor firmware updates via configuration equipment. Dynament Limited Hermitage Lane Industrial Estate ٠ Kings Mill Way ٠ Mansfield ٠ Nottinghamshire ٠ NG18 5ER ٠ UK. Tel: 44 (0)1623 663636 ٠ Fax: 44 (0)1623 421063 email: sales@dynament.com ٠ www.dynament.com TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 1 of 10

DESCRIPTION Dynament infrared sensors operate by using the NDIR principle to monitor the presence of target gas. The sensor contains a long life tungsten filament infrared light source, an optical cavity into which gas diffuses, a dual temperature compensated pyroelectric infrared detector, an integral semiconductor temperature sensor and electronics to process the signals from the pyroelectric detector. Two versions are available:- 3 Pin Version - Pellistor Replacement Infrared These sensors provide a pellistor style linearised, temperature-compensated output as shown in Graph 1. They can either be supplied pre-set to customer specification or may be configured by the user by means of a configuration unit available from Dynament Ltd. The output signal can be set to rise or fall with increase in the gas level. 5 Pin Version - Multi-Purpose Range This version of the sensor provides maximum user flexibility by providing the following output options:- Industry Standard 0.4 to 2 volt linearised, temperature-compensated output as shown in Graph 2, or alternative voltages for zero and full scale outputs. Digital output for direct communications with instrument electronics. Rising or falling output with increasing gas level. The digital output is a UART format comprising 8 data bits, 1 stop bit and no parity. Refer to specification for available baud rates. Contact Dynament Ltd for protocol details. Voltage Bridge Supply Voltage Rising Voltage 2.7 Volts Maximum 2 Volts Supply Mid-point Falling 0.4 V - Full scale Zero + Full scale Gas Zero Full scale Graph 1 Graph 2 Pellistor Replacement Characteristic 0.4 2 Volt Characteristic Gas TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 2 of 10

Hydrocarbon Response Characteristics The Premier range of hydrocarbon infrared gas sensors are calibrated to provide an output signal linearised for a specific gas type and concentration during manufacture. However, the sensor will also respond to a range of other hydrocarbon gases. The following graphs show the relative response of a methane sensor, and a propane sensor, to some of the common hydrocarbons. These characteristics can be used as a guide to setting up the associated instrument alarm levels. 5.00 4.50 Premier methane sensor cross sensitivity Reading on methane scale % volume 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 Methane Ethane Propane Butane Pentane Hexane Ethylene Ethanol Propylene Cyclopentane 0.00 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 Applied gas % volume 2.50 Premier propane sensor cross sensitivity Reading on propane scale, % volume 2.25 2.00 1.75 1.50 1.25 1.00 0.75 0.50 0.25 Butane Pentane Ethane Propane Ethylene Ethanol Hexane Propylene Cyclopentane Methane 0.00 0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 Applied gas % volume Note Refer to data sheet TDS0050 for additional cross reference data TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 3 of 10

Hydrocarbon Temperature Compensation The Premier sensor is temperature compensated over the range of -20 C to +50 C. The output variation is ± 2% full scale or ± 10% of the reading up to 50% full scale and ± 15% of the reading from 50% to 100% full scale, which ever is greater. The following graph is based on the hydrocarbon sensor being characterised for methane. Premier sensor temperature compensation -20 C to + 50 C 5.0 Gas reading 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 Ideal reading Min limits Max limits 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Applied gas Hydrocarbon Linearity The Premier sensor linearity at ambient temperature is ± 2% full scale or ± 10% of the reading which ever is greater. The following graph is based on the hydrocarbon sensor being characterised for methane, data based on 24 sensors. Premier sensor CH4 linearity Gas readings 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 Min reading Max reading Min limits Max limits 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Applied gas %v/v TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 4 of 10

Calibration options Dynament recommend a maximum interval of 12 months between calibration checks. A small amount of zero drift can be accomodated by re-zeroing the gas detector against the sensor. The degree of drift that is acceptable should be determined by the user. Note that the subsequent change in gas reading will be greater than the change in zero reading. If the sensor requires either a Zero or Span adjustment, there are three methods that can be used: 1) By using the Premier Configuration Unit When used in conjunction with dedicated PC software, this device uses the data communication pins on the sensor to provide a means of calibration. Refer to data sheet TDS0043 for additional information. 2) By using the data communications pins and software written in accordance with the protocol supplied by Dynament. 3) By using the "Manual Calibration" feature available with firmware version 1.5.2R. Zero and Span operations can be performed by momentarily connecting the data communication pins to the negative supply pin. Refer to data sheet TDS0064 for full instructions. The Manual Calibration option must be specified when the sensors are ordered. Sensor warm-up time When power is first applied to the sensor, the voltage at the output pin is held at a pre-determined level. The default setting for this start-up value is the zero gas value. This condition is maintained for a default warm-up time of 15 seconds, after this time the output voltage represents the calculated gas value. Sensors can take up to 1 minute to indicate the correct gas reading. Note: the sensor can output any reading from -100% full scale to +200% full scale in the first minute. The output value that is read using the communications pins is always held at zero during the warm-up time. Both the voltage at the output pin during the warm-up time, and the duration of the warm-up time can be pre-programmed to alternative values at the time of ordering sensors. Temperature transients and gas flow rates. The Premier sensor employs a pyroelectric detector, the output from which can be disrupted by sudden changes in temperature. If there is an excessive change in the ambient temperature, gas sample temperature or flow rate, then the output signal will be momentarily frozen. Correct operation is restored when the effects of the transient have settled. Rates of change in the ambient temperature should be restricted to 2 C/minute and gas flow rates kept below 600 cc/minute. Power supply considerations The sensor power supply rise time must be less than 50 ms to ensure correct operation. Operation outside the range of 3 5 V dc will result in either fault indication, or the sensor will not function correctly. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 5 of 10

Sensor over-range condition The sensor will continue to provide an output up to 200% of the full scale value; at this point the reading is clamped, regardless of any further increase in detected gas level. The linearity of the output is only guaranteed up to the full scale for the sensor; the over-range condition should therefore be determined and indicated by the host instrument. Sensor fault indication The sensor constantly performs checks on the internal memory contents, the incoming supply voltage and the analogue signal values. These checks are used to ensure that the sensor is operating within its correct parameters, and that no internal faults have developed. If a fault condition is detected: 1) the output will be set to 0V. 2) The output value that is read when using the communications pins, instead of the voltage output pin, will be set to -250% full-scale. As mentioned in the Sensor warm-up time section above, the voltage at the output pin during the warm-up time can be specified when ordering sensors. Digital interface The digital communication pins RX and TX operate at a 2.8V logic level. When interfacing to external circuitry that uses a higher voltage level it is necessary to limit the current that can flow. The external voltage level should be 5V maximum. For 5V signals use a 3K3 resistor in series with each communication pin. For 3.3V signals use a 1K resistor in series with each communication pin. The Rx and Tx voltage limits are as follows: RX - VIH: Input High minimum voltage - 0.8 VDD = 2.24V RX - VIL: Input Low maximum voltage - 0.2 VDD = 0.56V TX - VOH: High minimum voltage - VDD - 0.7 = 2.1 TX - VOL: Low maximum voltage - 0.6V Contact Dynament Ltd for details of the required protocol. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 6 of 10

Operating Voltage Range: Operating Current: Programmable Voltage Ranges: Methane measuring range: SPECIFICATION 3.0 5.0 V d.c. Constant current operation, current range 75 85mA Voltage Types 0v to 2.8 volts d.c. Bridge Types 0v to Bridge Supply Voltage 0 5% volume up to 0 100% volume Hydrocarbon measuring range 0 100% LEL equivalent Resolution: 1% of measuring range for readings above 50% of range, 0.5% of measuring range for readings below 50% of range Accuracy: ± 2% full scale @ 20 C (68 F), 1 bar pressure, applied gas 2.5% volume methane. Warm up time: To final zero ± 2% full scale : 1 minute @ 20 C (68 F) ambient Response Time T90: <30s @ 20 C (68 F) ambient Zero Repeatability: ± 1% full scale @ 20 C (68 F) ambient Span Repeatability: ± 2% full scale @ 20 C (68 F) ambient Long term zero drift: ± 1% full scale per month @20 C (68 F) ambient, (max ± 3% full scale per year) Operating temperature range: -20 C to +50 C (-4 F to 122 F) ± 10% of reading up to 50% full scale, ± 15% of reading Temperature performance: from 50% to 100% full scale, or 2% full scale whichever is * May not be applicable when using gas cross-reference factors greater over the range -20 C to +50 C (-4 F to 122 F) Storage temperature range: -20 C to +50 C (-4 F to 122 F) Humidity range: 0 to 95% RH non-condensing. Digital signal format: 8 data bits, 1 stop bit, no parity. 2.8V logic level Standard baud rates: 38,400, 19,200, 9600 User configurable parameters: Zero output voltage Full scale output voltage Positive or negative going output Sensor zero function Sensor span function MTBF: > 5 years Weight: 15 grams + ve supply, see notes Signal 4.24 7.62 Tx 0.43 Rx MECHANICAL DETAIL - ve supply, see notes 5.08 10.67 4.8 +0.5/-0.0 16.6-0/+0.2 20 Dia. 15mm Dia 20mm NOTES 1. TOLERANCE: +/- 0.15 UNLESS OTHERWISE STATED. 2. RECOMMENDED PCB SOCKET WEARNES CAMBION LTD CODE: 450-3326-01-06-00. 3. USE ANTI-STATIC PRECAUTIONS WHEN HANDLING 4. DO NOT CUT PINS 5. DO NOT SOLDER DIRECTLY TO PINS 6. THE LABELLING ADDS UP TO 0.2 TO THE OUTER DIAMETER, AND UP TO 0.2 TO THE OVERALL HEIGHT All dimensions are in millimetres. Pins viewed from underside Diameter of pins = 1.5 +/- 0.05 Tx & Rx communication connections are available as either pads or pins NOTE The above pin configuration is shown for the POSITIVE version of the sensor. The NEGATIVE version has the +ve and ve supply pin positions exchanged. See ordering details. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 7 of 10

CERTIFICATION DETAILS European ATEX Certification Sensor type MSH-P Sensor type MSHia-P Approval body Certificate Number Test Standards Certification Codes Input parameters Operating temperature SIRA SIRA 04ATEX1357U EN60079-0:2012+A11:2013, EN60079-1:2014, EN60079-11:2012, EN60079-26:2015 I M2 Ex db I Mb II 2 G Ex db IIC Gb 0.8W max, 30V max. (See footnote) -20 C to +60 C (See footnote) I M2 Ex db I Mb II 2 G Ex db IIC Gb 0.8W max, 30V max. (See footnote) International IECEx Certification Sensor type MSH-P Sensor type MSH-P Approval body SIRA Certificate Number IECEx SIR 05.0053U Test Standards IEC 60079-0:2011, EN60079-1:2014 EN60079-26:2014 Certification Codes Ex db I and/or Ex d IIC Ex db I and/or Ex d IIC Input parameters 0.8W max, 30V max. 0.8W max, 30V max. Operating temperature -20 C to +60 C (See footnote) North American Certification Sensor type MSH-P Sensor type MSHia-P Approval body Underwriters Laboratory Inc. Underwriters Laboratory Inc. File Reference E336365 E336365 Test Standards UL 60079 0, 4 th Edition UL 60079-1, 6 th Edition CAN/CSA-C22.2 No. 60079-0-1-7 CAN/CSA-C22.2 No. 60079-1 part 1, 1 st Edition UL913 7 th, Edition UL 60079 0, 4 th, Edition UL 60079 11, 2 nd, Edition CAN/CSA-C22.2 No. 157-92 Hazardous Locations Class 1, Zone 1, AEx d IIC and Ex d IIC Hazardous Locations Class I, II, III, Division 1 Class 1, Zone 0, AEx ia IIC, T4 with 60 C ambient Input/Entity parameters 0.8W max, 30V max. Ui=6V dc, Pi=0.8W, Ci=4.105µF, Li=0 mh Input parameters are defined for certification purposes only, refer to the Specification table for the sensor operating voltage and temperature range. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 8 of 10

Ordering Details In order to completely specify the type of sensor that is required, the customer needs to provide the following information:- An Order Code (see below) that specifies the sensors basic physical and electrical characteristics. The sensor configuration requirements. Available sensor options: F = Replaceable, self adhesive microporous PTFE filter EXAMPLE OF ORDER CODES MSH P / HC / 3 / B / P / F FILTER : Option BLANK = OMITTED F = FITTED SUPPLY POLARITY : P = Positive N = Negative OUTPUT TYPE : B = Bridge V = Voltage NUMBER OF PINS : 3 or 5 GAS TYPE : HC = Hydrocarbon PREMIER SENSOR TYPE MSH or MSHia (For Mining M1 applications only) CONFIGURATION OPTIONS (To be stated on customer order in addition to the Order Code) 1. voltage for zero. 2. voltage for span. 3. Rising or falling output voltage with increasing gas level. 4. Sensitivity e.g. 20 mv / % volume CH4. 5. Communication speed 38,400 baud (default), specify alternative rate if required. Pellistor Replacement - Explanation of Positive & Negative Polarity SIG DET COMP RX OUTPUT TX + - POS RX OUTPUT TX + - POS Note On the 3 pin version of the sensor, the RX and TX connections are pads, not pins. Typical Pellistor Pinout Premier Negative Polarity Option Premier Positive Polarity Option Use where the DET pin of the existing pellistor is connected to the Negative of the pellistor bridge supply. Use where DET pin of the existing pellistor is connected to the Positive of the pellistor bridge supply. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 9 of 10

Warranty information All Dynament Premier sensors carry a five-year warranty against defects in materials and workmanship. The warranty is invalidated if the sensors are used under conditions other than those specified in this data sheet. Attention should be paid to the following criteria: Observe the correct supply polarity Do not exceed the maximum rated supply voltage of 5V Do not solder directly to the sensor pins Do not expose the sensor to corrosive gases such as hydrogen sulphide Do not allow condensation to take place within the sensor Dynament reserve the right to alter technical specifications, without prior notice, when it is appropriate to implement a technical enhancement that leads to improved performance. Should any changes be required that could affect the customer s use of the product, Dynament will endeavour to contact customers directly to inform them of the changes. TDS 0034 Issue 7.5 14/12/17 Change Note:596 Page 10 of 10