D-Tect 2 GJD300 Quad PIR Movement Detector

Similar documents
D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Dual Tech. GJD360 Triple Technology External Detector

Movement Detector GJD 300

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

DI601AM Outdoor PIR/AM Detector Installation Sheet

Installation Manual Premier Elite Orbit QD/DT INS483-2

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Intrusion Outdoor Protection Perimeter

LUX Hardwired - Installation Notes

Description. Optex Incorporated

Advanced DIGITAL Wired PIR Motion Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

English. Italiano. Português. Françias. Español

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

PRODUCT GUIDE Electronic Perimeter Detection & High Performance LED Illumination

Emerald 3000 MK3 GJD010 Lighting Controller

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

English. Series. Installation and Use Manual

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Passive Infrared Motion Detector 5420/90P. Installation Instructions

DUAL OPTIC. Installation manual

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

LPCMPIRM65 & LPCMPIRDSI65

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

LS800S Intruder Alarm System. Engineering Manual

Active Infrared Multi Beam Sensors

HX-80NRAM. High Mount Outdoor Detector

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

Intrusion sensors. We listened to you

Hardwired Alarm Accessories

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

1125 PIR Motion Detector

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

SYSTEMS GROUP. May Zilog and EE-SGI Present. epir TM. The Next Generation of PIR Motion Detector Technology. (Over View)

Installation Instructions

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

Sensors. Supplied by: User Interfaces. Networked Controls Product Catalogue

HDCVI PIR Camera User s Manual

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

Active Infrared Multi Beam Sensors. R Series

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Model 3300 Technical Support and Installation Manual

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

DYGIZONE GJD910 Lighting Controller & Enunciator

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

SECURIT 700L PLUS ENGINEERING MANUAL

Extended Range DUAL TEC Motion Sensor

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation And commissioning manual. Series S Double Beam 1/16

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

AT A GLANCE. Product D-TECT2/3/40/50 D-TECTX MKII 30/40/50. Dygi-TECT D-TECT LZR. Elite. Opal RFX. Opal/Mini-Opal D-LITE. Dygizone/Emerald/Sapphire

Commercial Series TriTech Motion Detector. Reference Guide

FR-A180 FR-A360. Occupancy detector. Use

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

Ceiling PIR HS presence detector. Product Guide. Overview. Features

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

PERMACONN PM1030 Includes DI300. Installation Manual

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

General Purpose IO Technical Manual

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Long-Range Barrier Sensors

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

EnvironmentalMonitoring

Quick Selection Guide Intrusion Detectors

DS160/161 Request To Exit PIR sensors Installation Instructions

Commercial Series TriTech+ Motion Detector with Anti-mask

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

Reflective Optical Beam Smoke Detector User Guide

Premium 8 Zone Wireless Alarm Kit

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

TRUST WIRELESS ALARM SYSTEM 200S

VX-402, VX-402REC CONTENTS FEATURES

"Pegaso" wireless alarm system

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Transcription:

D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x Tamper Feet x Tamper Cup x Installation manual 4. 5. Connecting The Unit The D-Tect includes jumpers that allow you to configure the internal end-of-line resistor values, when EOL resistors are required. Values are K, K, 3K3, 4K7, 5K6 and 6K8 Ω. Figure 8 shows:. EOL resistor jumpers. Wiring points Alternatively, you can remove the jumpers and connect a discrete resistor directly to the alarm or tamper outputs, as specified by the third-party equipment. Introduction The D-Tect is an outdoor motion detector and alarm trigger that uses two independent passive infra-red detectors, both of which must trigger to cause the detector to signal an alarm. Utilising quad PIR technology, the D-Tect delivers precise, reliable presence detection. Quick Installation.. 3. 4. Mount and connect the detector following the instructions given later in this sheet. Apply supply voltage to the unit. The detection LED (blue) flashes three times. Wait approximately to 3 minutes to allow the detector to settle. Press the programming button once to activate walk test mode. The detection LED is now enabled for five minutes. Note: The front cover must be fitted when walk testing. Connections The default settings are: Range: 0 meters Pulse count: (always set to during walk test) Detection LED: off (always enabled during Walk Test) 'S' Lux Level: 5 Contacts: Alarm : Normally Closed Alarm : Normally Open Contacts Timer: 5 (seconds). Label Description A 4 hour -VE Output S Dark -VE Output 3, 4 ALARM Alarm relay 4, 5 EOL End-of-line resistors 5, 6 TAMPER N/C Tamper relay, normally closed 7, 8 ALARM Alarm relay 9, 0 9-4V AC / DC Supply The multifunction lens fitted to D-Tect produces seven long range beams and seven medium to short range curtain PIR beams. The PIR circuitry detects changes in heat and movement in the beam pattern; therefore items such as trees, shrubs, ponds, boiler flues, and animals should be considered when positioning the detector. Note: The PIR sensor is more sensitive to movement across the beams, and less sensitive to movement directly towards or away from the beams. The detector module is fitted with two sliding shutters to reduce the detection angle. During installation, protect the electronics against water, as trapped moisture can affect or damage the unit. Drill the wall to accept the two fixing screws, the cable entry, and the tamper cup (if used). See Figures and. A hole-drilling template is provided. Note: We recommend using the tamper cup on uneven wall surfaces. Remove the cover assembly by loosening the locking screw using the allen key provided. The cover hinges from the top and lifts out of the location slot. See Figure 3. Terminal Multibeam Alignment & Masking Mounting The Unit. Feed standard eight-core alarm cable into the cable entry. Bare the wires and connect to the top PCB terminal block. See Figures, 4 & 5. Screw the unit to the wall ensuring that the rear tamper pin is correctly located and that the tamper microswitch is closed. See Figure 6. To aid installation, two spare tamper feet are provided. One is mm longer and the other is mm longer than the tamper foot originally fitted. The tamper foot is a push fit and can be removed by carefully pulling it from the pin. See Figure. When the detector is aligned, connected, and programmed to suit the installation, replace the front cover and lock as shown. See Figure 7. The curtains are fitted to the pan and tilt module as shown in Figure 9 (shown with primary and additional curtain sliders fitted). Each section of the detector lens gives a coverage pattern of approximately 0 degrees. An additional set of curtain sliders is provided should the beam pattern need to be narrowed even further, e.g. if the minimum detection angle of 0 degrees is required. When coverage exceeds the desired detection area, adjust the module as required and mask off any beams, either vertically or horizontally, to avoid unwanted detection. --

Use portions of the self-adhesive silver mask applied to the rear, smooth side of the lens as shown in Figures 0 and. Always replace the lens the correct way up to ensure exact beam pattern coverage (top of the lens is marked TOP). To change any of the D-Tect settings:. Press the program button, as shown in figure 6, for the number of the Option to be changed, i.e. once for range, twice for pulse count, three times for LED, four times for lux, five times for contacts and six times for timer. Note: If using the IR Key Fob, press the key fob button instead of the detector's program button. See Figure 7.. Wait until the blue LED indicator goes off (typically four seconds). When mounted at heights above 3 metres there could be a significant reduction in the range of detection and the target will have to move a greater distance within the field of view before an alarm is generated. Masking Configurations For Maximum Range Configuration Mounting Height (Metres) Tilt ( ) Max. Range (Metres) Reference Multibeam (Optimum) 3 0 Figure 0 Pet Immunity *.5 - Figure 3. The indicator will then flash out the existing settings. 4. To change the settings for that option, press the program button the number of times for the required new setting. 5. The indicator blinks twice and the changes are stored in the D-Tect 's non volatile memory. Note: When power is applied to the D-Tect, the user has a time slot of 5 minutes to start using the IR key fob. This can be reset either by pushing the program button as shown in figure 6 or by removing then reapplying power to the D-Tect. * Black area should be masked for pet alley applications up to meters. Figure shows the pattern for the maximum range in the optimum position (see Figure 0). Masking the top section of the lens reduces the range to 0m. Figure 3 shows the pattern for the minimum range. In this case masking the top section of the lens reduces the range to 6 meters. Example: To change the LED setting from OFF to ON:. Press the program button three times. Note: If using the IR Key Fob, press the key fob button instead of the detector's program button. See Figure 7.. Wait until the blue LED indicator goes off (typically four seconds). 3. The indicator will then flash once, indicating the current LED setting is OFF. 4. Press the program button twice to change the setting to ON. 5. The indicator blinks twice and the changes are stored in the D-Tect 's non volatile memory. Figures 4 and 5 illustrates alignment recommendations for when the detector is mounted close to a wall. The alignment shown in Figure 4 is not recommended. If the detector module is orientated at an angle of 90 to the perimeter, the mounting wall may cut off short and medium range beams. The long range beam will still detect an intruder, however the wall can cause false alarms when heated by sunlight. Figure 5 shows the recommended alignment. The detector module is orientated at a 55 angle to the perimeter. As a result, short and medium range beams are parallel to the perimeter, but the detection range along the perimeter is reduced to 5 metres. Programming Options Definitions Pulse Count This is the number of times the unit has to detect on both of its sensors before signalling an output. Programming The user can individually program a number of configurable settings, as illustrated in the programming chart. LED LED Off LED disabled. LED On LED signals a detection. Programming Chart SETTING 3 4 5 5 Range (m) 8 5 0 Pulse Count 3 O LED Off On P 3 T 'S' Output 5 0 I 4 Lux Level O N Alarm N/O N/C N/C S 5 Contacts Alarm N/O N/O N/C 6 Timer Seconds A 7 U X 8 5 0 6 7 Lux Level This is the approximate level that the ambient light must reach before the 'S' output will become active when there is an activation. 8 The 'S' output switches negative for 60 seconds when there is a detection and the light level is below the programmed setting. 0 0 40 40 50 50 The 'S' output is an open collector type rated at maximum 5mA. 4 HR Alarm & Alarm Outputs These are magnetically immune volt free relay contacts used to trigger alarm inputs on connected equipment. They can be set to be both normally open, one normally closed and one normally open or both normally closed. 60 Press 7 times to flash out your selected settings The contacts are rated at a maximum of 4V AC/DC @ 50mA. Press 8 times to reset to GJD factory settings Shaded settings are factory defaults --

Timer The timer setting adjusts the time that the relays change state after activation (to reduce repetitive alarms). Walk Test In walk test mode, the detection LED option is set to ON, and the pulse count option is set to. The detection LED lights each time the D-Tect detects your presence. To enter the walk test mode, press the programming button once. The detection LED lights and pulse count is automatically selected. The unit can then be aligned. Tamper Switches Front and rear tamper switches; case open and removal from wall. Power Input 9 to 4 V AC/DC. Current 0mA (V nominal). Pulse Count - 3. Temp. Compensation Digital sensitivity adjustment. Control Digital microprocessor non volatile memory. The test mode ends automatically five minutes after last detection. Alternatively, press the program button three times, or remove and then reapply power to cancel the walk test mode. Walk Test Output test mode with LED indication Operating Temp. -0 to +55 Centigrade Conformal coated electronics for increased stability. Note: When you conduct a walk test, make sure that the front cover is in place. Do not conduct walk tests with the cover removed. Housing High impact zinc alloy. Protection Rating IP 65. The range of the detector increases without the protective front cover. Therefore the front cover must be fitted to establish the correct beam pattern. Use programming chart to adjust the range as necessary. Pan and tilt the lens module over the field of view to obtain the correct coverage area. Dimensions 45 x 0 x 5 mm. Weight 750 grams NET, 880 grams GROSS Mounting Height Variable - optimum height 3 metres. Accessories Cable < 00m Using all five outputs (including tamper) core 7/0.mm Cable < 500m Using all five outputs (including tamper) core 6/0.mm GJD is able to supply the following accessories to aid installation: GJD3 GJD4 GJD5 GJD380 Infra-red Key Fob Programmer Conduit cable entry adaptor ring Pole mount clamp D-Tect Walk Tester CE Mark GJD reserve the right to amend specifications without prior notice Specifications Detection Area Programmable between 8 & metres. Coverage 0-70 degrees detection angle, m x m coverage max. Adjustment 80 degree pan + 90 degree tilt. Fresnel Lens 8 zones for each Pyro pair, which can be masked with curtain sliders and special masking tape (supplied). Customised Optics Double silicon shielded quad element eliminates 50,000 Lux of white light. Outputs Silent solid state magnetically immune. Alarm & Alarm GJD Manufacturing Limited Unit Birch Industrial Estate Whittle Lane Heywood Lancashire OL0 SX Sales: Technical: Fax: Email: Web: +44 (0) 706 363 998 +44 (0) 706 363 990 +44 (0) 706 363 99 info@gjd.co.uk www.gjd.co.uk Volt free relay signal contact 4V AC/DC @ 50mA with an integral 5Ω series resistor, selectable N/O & N/C. Adjustable timer options: to 60 seconds Output 'A' Open collector negative switching 5mA max. Alarm period 400ms. Output 'S' Open collector negative switching 5mA max. Alarm period: detection + 60 seconds. Adjustable: Dusk ( Lux) to 4 hour. D-Tect GJD0 Quad PIR Movement Detector Output 'T' Tamper Volt free, normally closed switch output -3-

Optional for Tamper Cup Cable Holes Template 3 4 / 4V AC Supply 0V Supply VDC Supply To GJD Lighting Controller Alarm Output Multiplexer, PTZ Dome DVR, Etc. 5 6 7 8 Normally Closed Tamper Circuit Front + Rear Alarm Output Multiplexer, PTZ Dome DVR, Etc. EOL Resistor Selectors 9 0-4-

3 4 5 6 Programming LED Programming Button 7-5-

Engineer Notes GJD Manufacturing Limited Unit Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL0 SX Sales: +44 (0) 706 363 998 Email: info@gjd.co.uk Technical: +44 (0) 706 363 990 Web: www.gjd.co.uk -6- Fax: +44 (0) 706 363 99

Engineer Notes GJD Manufacturing Limited Unit Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL0 SX Sales: +44 (0) 706 363 998 Email: info@gjd.co.uk Technical: +44 (0) 706 363 990 Web: www.gjd.co.uk -7- Fax: +44 (0) 706 363 99

Engineer Notes GJD Manufacturing Limited Unit Birch Industrial Estate, Whittle Lane, Heywood, Lancashire, OL0 SX Sales: +44 (0) 706 363 998 Email: info@gjd.co.uk Technical: +44 (0) 706 363 990 Web: www.gjd.co.uk -8- Fax: +44 (0) 706 363 99