Room Sensor for BACnet VAV Actuator

Similar documents
Installation and Maintenance Manual IM 1038

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Installation and Maintenance Manual IM 1102

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

ELECTRIC FLAT PANEL FIREPLACE HEATER

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Switch Housing.

Table of Contents What to Expect with Your Installation. Top Housing. Ceiling Plate. Tools Needed.

Table of Contents. What to Expect with. Mounting Options. Tools Needed

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Table of Contents. 1 M /10/14 Casablanca Fan Company. What to Expect with Tools Needed.

Installation & Operation Manual for WarmlyYours Towel Warmers

Table of Contents. What to Expect with. Mounting Options. Tools Needed

Installation & Operation Manual for WarmlyYours Towel Warmers

MINI BLINDS Classic GETTING STARTED STANDARD HARDWARE. A few simple tools are required: OPTIONAL HARDWARE

ITEM # SAIL STREAM CEILING FAN MODEL #41695

Table of Contents. 1 M /11/13 Casablanca Fan Company What to Expect with Your Installation

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Uponor Climate Cŏntrol Network System Thermostat Installation and Operation Guide RADIANT HEATING SYSTEMS UPONOR CLIMATE SYSTEM THERMOSTAT

ST. KITTS CEILING FAN

Table of Contents. What to Expect with Your Installation. Tools Needed. Mounting Options. Ceiling Bracket. Wiring.

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

What to Expect with Your Installation. Tools Needed. 30 inches PA G E. To register your fan, please visit: 11 PA G E

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

72 ONYX XL FLAT PANEL ELECTRIC FIREPLACE

Proliphix Thermostat Installation Guide. Release 2.0

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

Installation Instructions

INSTALLATION INSTRUCTIONS

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Table of Contents What to Expect with. Tools Needed. Mounting Options. Wiring. Downrod. Canopy.

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

180 Degree Ceiling Mounted Occupancy Sensors

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

ELECTRIC FLAT PANEL FIREPLACE HEATER

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

Installation Guide. For Model: COS52OSB5CR READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (9.9 kg) PRINTED IN CHINA

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

installation and operation manual for Hunter Ceiling Fans

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Installation and Care Instructions

ITEM # , CARATUK RIVER CEILING FAN MODEL #40046, 40303

Wall Mount Electric Fireplace

Installation Instructions

Wall Hanging Mode. Pedestal Mode

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

IntelliDoX Operator Manual

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

CONGRATULATIONS! TABLE OF CONTENTS. Introduction. Features and Benefits. Parts Guide 4. Installation Considerations 4. Installing the Loudspeaker 6

Installation Instructions

48 TAYLOR CEILING FAN

Installation and Care Instructions

ITEM # HYDRA CEILING FAN MODEL #41371

ELSTON 52 CEILING FAN

Wood. Blind owner's handbook

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

3CLMR56XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3CLMR56XXD

Owner s Guide and Installation Manual

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

Speaker Wall Mount (MSP-DCCSPM)

3DIR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3DIR52XXD

Owner s Guide and Installation Manual

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades.

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

HDCVI PTZ Camera. 6C Series. Quick Start Guide Version Dahua Technology USA Inc.

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

DPM-G DPM-CR DPM-W DPM-B INDOOR DOME PENDANT MOUNT INSTALLATION MANUAL

Viking Installation Guide

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

DM60-xxx Antennas. 1. Assembly. Installation Instruction for CMAX Antennas

Model NT20e Installation Guide

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

Ceiling Fan Installation Instructions

Install Guide Customer Support: or Visit our website

3AVOR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3AVOR56XXXXX

Tripod Ceiling Fans. Installation Instructions Models: CT52, D52, FR52, ME52 & OL52 (800) BETTER BY DESIGN MEJOR DISEÑO BETTER BY DESIGN

Owner s Guide and Installation Manual

52 CEILING FAN. Owner s Manual Models #50336, 50337

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

Installation. Leveling

DOUBLE DISHDRAWER TM DISHWASHER

Transcription:

BACnet VAV Actuator Room Sensor Installation Manual IM 1038 Group: Controls Part Number: IM 1038 Date: 3/4/2010 Supersedes: New Room Sensor for BACnet VAV Actuator Model(s): 2508031 & 2508032 2010 McQuay International

Table of Contents Table of Contents... 2 Revision History...3 Reference Documents...3 Limited Warranty...3 General Information... 4 Hazard Identification Messages...4 Getting Started... 5 Installation... 6 Required Tools and Materials...6 Installing a new BACnet VAV Actuator Room Sensor...6 2 IM 1038

Revision History IM xxx Date Initial release Reference Documents Number Company Title Source www.mcquay.com Limited Warranty Consult your local McQuay Representative for warranty details. Refer to Form 933-43285Y. To find your local McQuay Representative, go to www.mcquay.com. Notice Copyright 2010 McQuay International, Minneapolis MN. All rights reserved throughout the world. McQuay International reserves the right to change any information contained herein without prior notice. The user is responsible for determining whether this software is appropriate for his or her application. The following are tradenames or registered trademarks of their respective companies: BACnet from the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.; Windows from Microsoft Corporation; McQuay and MicroTech III from McQuay International. IM 1038 3

General Information This manual contains the information you need to install the BACnet VAV Actuator Room Temperature Sensor. Hazard Identification Messages! DANGER Dangers indicate a hazardous situation that will result in death or serious injury if not avoided.! WARNING Warnings indicate potentially hazardous situations, which can result in property damage, severe personal injury, or death if not avoided.! CAUTION Cautions indicate potentially hazardous situations, which can result in personal injury or equipment damage if not avoided.! WARNING Electric shock hazard. Can cause personal injury or equipment damage. This equipment must be properly grounded. Connections and service to the MicroTech III Chiller Unit Controller must be performed only by personnel knowledgeable in the operation of the equipment being controlled.! CAUTION Static sensitive components. Can cause equipment damage. Discharge any static electrical charge by touching the bare metal inside the control panel before performing any service work. Never unplug cables, circuit board terminal blocks, or power plugs while power is applied to the panel. NOTICE This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense. McQuay International disclaims any liability resulting from any interference or for the correction thereof. 4 IM 1038

Getting Started Review these instructions before beginning. Confirm that appropriate field wiring is installed (standard six-conductor room sensor cables, plenum or non-plenum as required) within the maximum wiring run length for the individual equipment controller. The maximum recommended length is 100 feet (30 m). All wiring must comply with National Electric Code (NEC) and local regulations. Description These room sensors allow users to view and adjust points in the controller using the room sensor buttons and digital display. Application They work with McQuay BACnet VAV Actuator 2508021 and 2508021P10. These devices incorporate a solid state or 10K NTC sensing element to detect temperature. The effective sensing and setpoint range is 55 to 95 F (13 to 35 C). These room sensors can be mounted on electrical boxes, stud-type mounting brackets, or drywall. Obtain the necessary mounting hardware and follow the appropriate mounting procedures for the type of installation required. Figure 1: Temperature Room Sensor IM 1038 5

Installation The following section describes how to field install a new BACnet VAV Actuator Room Sensor. Expected Install Time: 20 minutes! CAUTION Electrostatic discharge hazard. Can cause equipment damage. This equipment contains sensitive electronic components that may be damaged by electrostatic discharge from your hands. Before you handle a communications module, you need to touch a grounded object, such as the metal enclosure, in order to discharge the electrostatic potential in your body. Required Tools and Materials Phillips sizes 1 and 2 screwdrivers Small and medium flat-blade screwdrivers 1/16-inch hex key Medium-duty electric drill 3/16-inch (4.8 mm) drill bit One-inch (25 mm) hole saw Small level Tape measure Marker or pencil If using non-terminated or damaged cables, you also need: Room sensor connector tool (RJ-11 crimping tool) Room sensor connector kit (P/N 2508046) Installing a new BACnet VAV Actuator Room Sensor Mounting Information Always mount the room sensor vertically, on a flat wall. Locate the room sensor: According to design specifications and local regulations. Where the air circulates around it freely (not in recessed areas or behind doors). Allowing a minimum of 4 inches (10 cm) free space above and below for proper airflow, the hex bit or passkey tool, and the computer communication cable. Away from drafts caused by doors, windows, outside walls, air registers, pipes, return air plenums, etc. Away from heat sources such as strong lights, fireplaces, direct sunlight, etc. On an inside wall (preferably), about 5 feet (1.5 m) above the finished floor or per code (ANSI, ADA, or local regulation). 6 IM 1038

Drywall Mounting (No Rough-in), Typical 1. Mark the center (cable) hole and the mounting hole locations, using the room sensor base plate as a template. See Figure 2. 2. Drill two 3/16-inch (4.8 mm) mounting holes and mount the two plastic wall anchors flush to below the wall surface for stable mounting of the device. 3. Cut a 1-inch (25 mm) center hole with a hole saw. 4. Pull about three inches (75 mm) of the cable through the hole in the base plate. Figure 2. Drywall Mounting (No Rough-in), Typical. 5. Mount the room sensor base plate on the wall, noting the "UP" arrow: a. Install the two mounting screws provided, but do not tighten. b. Level the room sensor base plate for appearance. c. Tighten the two mounting screws to the room sensor base plate. 6. Do one of the following: If the cable is terminated: Inspect the RJ-11 connector for damage. If the cable is non-terminated or if the RJ-11 was damaged: Cut the cable, leaving about three inches (75 mm) on the room sensor side of the drywall, and attach an RJ-11 connector with an RJ-11 crimping tool. On the RJ-11 connectors, ensure that pin Number 1 connects to the same wire at each end of the cable. See Figure 3. IM 1038 7

CAUTION For retrofits: Before cutting the cable, make sure it is disconnected from the Temperature Room Sensor port on the controller cable end. Figure 3. Terminating the RJ-11 Connector. 7. Plug the terminated cable into the RJ-11 connector on the back of the room sensor's printed circuit board (PCB). 8. Feed the extra cable back through the hole. 9. Snap the room sensor cover to the room sensor base plate by first hooking the room sensor front to the top latches, and then rotating the cover downward until it latches. 10. Loosen the safety set screw at the bottom of the base one or two revolutions to lock the cover to the base. Be careful not to loosen too far as the screws can be completely removed from the base. 11. Connect the room sensor to the Temperature Room Sensor port on the controller. The installation is now complete. Electrical Box and Rough-in Mounting, Typical 1. If a locator is attached to the rough-in device, remove the locator by removing the two screws and lightly rocking the locator to pull it free. 2. Untie the twist tie and pull about three inches (75 mm) of the room sensor cable through the hole in the base plate. 3. Mount the room sensor base plate on the wall, noting the "UP" arrow: a. Install the two room sensor mounting screws provided, but do not tighten. b. Level the room sensor base plate for appearance only. c. Tighten the two mounting screws to the room sensor base plate. CAUTION Over-tightening may cause the room sensor base plate to crack or bend. 4. Continue with Drywall Mounting (No Rough-in), Typical, Steps 7 through 11. The installation is now complete. This document contains the most current product information as of this printing. For the most current product information, please go to www.mcquay.com. All McQuay equipment is sold pursuant to McQuay s Standard Terms and Conditions of Sale and Limited Warranty. 2010 McQuay International www.mcquay.com 800-432-1342