FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

Similar documents
Firestone Lining Systems. Dependable Performance in Demanding Environments

SPIDER P SPIDER P mineral

Civil engineering Fibertex Geotextiles

RG1,5SA Self Adhesive

Firestone GeoGard EPDM Review of Technical Performances

Civil engineering Fibertex Geotextiles

Firestone EPDM Geomembrane Review of technical performances

CONTINUOUS GEOMEMBRANES FOR ON SITE APPLICATION. PDA Europe 2012 Annual Conference Istanbul, November

DRESS YOUR POOL IN COLOR WITH TEXPOOL TEXPOOL NG 11. Reinforced 1.5 mm waterproofing membrane, for that touch of elegance

SPECIAL SPECIFICATION 3687 Impermeable Liner

Geomembranes that work

Geomembranes that work

EFFISUS BRAZE MEMBRANE

G E O T E X T I L E S

Nonwoven geotextile. Edilfloor Professionalism and knowledge at 360

Leadax B.V. Covenant K93792/02. Leadax

Rhepanol hg. For more information on SIG Design & Technology visit A solid foundation for green roofs.

ARIES. 3,9mín 0,5 ( ph < 4)

MASTERBATCHES. Masterbatch Selection Guide for Geosynthetics

EARTH STABILIZATION GEOSYNTHETIC SOLUTIONS

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

SYSTEM OVERVIEW UTILITY ROOFDECKS GREEN ROOFS PODIUM ROOF DECKS PARKING ROOF DECKS 0.1

Liner Construction & Testing Guidance Overview

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED Quality ISO 9001

LiteEarth Advanced Synthetic Grass Geomembrane Liner INDEPENDENT THIRD PARTY PERFORMANCE TESTING REPORT. U.S. Patent No.

Section 714. GEOTEXTILE AND GEOCOMPOSITE DRAIN MATERIAL

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology

Technical Specification Guidelines

J. K. Gupta, Scientist D, Bureau of Indian Standards

NOPHADRAIN RO O F DE C KS. The inverted roof, a sound construction for roof decks! GREEN ROOFS PODIUM ROOF DECKS PARKING ROOF DECKS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

geotextiles bidim Nonwoven polyester geotextile Made in Australia Designed for performance RECYCLED

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

Chapter 12 Greenroof design, construction and maintenance

Table of contents. Introduction Design. 2. Installation. Attachments

GEOMEMBRANES FOR SEEPAGE CONTROL IN DAMS: NEW TECHNOLOGIES IN REHABILITATION AND NEW CONSTRUCTION

DUPONT TM PLANTEX LANDSCAPE SOLUTIONS Guidebook

Fortrac 3D Geogrid. High-Tensile Anti-Slip Reinforcement with Soil Retention Function

CI/SfB (16)(17) Common Arrangement D11 Uniclass L1411/ L132/ L6634. Woven Polypropylene Geotextiles.

DuPont TM Plantex landscape solutions Guidebook

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

Introduction. Functions of Non woven Geotextile (TechGeo) Separation. Filtration. Drainage. Containment. Tech Geo. . Geotextile Overview

Long-Term Durability of a 20 mil PVC Geomembrane

GEOSYNTHETICS PRODUCT OVERVIEW

Advantages gained from the use of a geomembrane waterproofing system on RCC dams: experiences from Australia

Bituminous Geomembranes in Canal Construction for Irrigation Projects

Greening the Built Environment. EXTENSIVE, INTENSIVE. Roof Garden. General Specifications

Icopal Screw Fasteners & Accessories

PavePro Stabilise Gravel & Decorative Stone.

Visqueen Vapour Control Tapes

FLEXIBLE NON-METALLIC COVERING FOR INDUSTRIAL INSULATION. Specially developed for use in offshore and industrial environments

6. Detail drawings. 1. Lap Splices 2. Corners 3. Penetrations 4. Terminations 5. Anchoring 6. Membrane cover

SCOPE OF ACCREDITATION. High-visibility clothing EC type examination LST EN ISO 20471:2013. EC type examination LST EN ISO 11611:2008

Firestone Reinforced Polypropylene (fpp-r) Geomembrane

Butyl Products Ltd. Pond Guide

Rhyno. Woven Polypropylene Geotextiles. Geosynthetics Limited

Introduction To Geosynthetics In Transportation

Scope of accreditation

AASHTO M Subsurface Drainage

Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva

A PVC geomembrane integrated in the landscape

Design Guide Fibertex Geotextiles

List of tests (2018)

Woven Polypropylene Geotextiles

PVC aquaculture liners stand the test of time

Aquaculture Lining Systems

Global Coitment to Quality Global Synthetics with their German partner, Naue GmbH, are now able partner, Naue GmbH, have strong coitments to quality a

Greening the Built Environment. EXTENSIVE, INTENSIVE. Roof Garden. General Specifications

Section Specification for Geotextile Used in Permanent Erosion Control Application

GIBE III: A ZIGZAG GEOMEMBRANE CORE FOR A 50 M HIGH ROCKFILL COFFERDAM IN ETHIOPIA

D.P.E. Enviroliner. geotextile protection layer. covering new ground 2016

G E O T E X T I L E s o l u t i o n s

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Geotextile Pipeline Weights

GRI White Paper #12. The Development of a Benefit/Cost Ratio Matrix for Optimal Selection of a Geosynthetic Material

SECTION TABLE OF CONTENTS GEOTEXTILE TUBES PARAGRAPH TITLE PAGE NOS.

REHABILITATION OF SAIDA DUMPSITE

CE TYPE EXAMINATION CERTIFICATE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Specification Suggestion Sedum Roof Plus with Floradrain FD 25-E P a g e 1

The Laboratory is qualified to update standards identifying the test procedures. Test procedure/ method identification

The Laboratory is qualified to update standards identifying the test procedures.

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

The Laboratory is qualified to update standards identifying the test procedures.

Coir Block System (fabric attached coir block) add New Dimension to Streambank Stabilization Projects

flat green roof structures

SET A NATURAL EXAMPLE. Green roofs on small areas in the private sector

Module 5 Erosion & Sediment Control. Introduction To Geosynthetics In Transportation. Prepared by. For the Local Technical Assistance Program

PLAY AREA LANDSCAPING

UNIFIED FACILITIES GUIDE SPECIFICATION

Twenty five years experience using bituminous geomembranes as upstream waterproofing for structures

Annex of the certificate (Page 1/5) Accreditation Scope

Cold. Humid warm. Fischer Kondensstop. * An enterprise of Corus Distribution & Building Systems

Alternative Cover Systems

Concrete pavers with sand filled joints. Bedding sand 1-1/2 in. (25-40 mm) thick

EROSION CONTROL SYSTEMS

BS EN ISO : 2010

Specification Suggestion Sedum Roof with Fixodrain XD 20 P a g e 1

Technical Supplement 14D. Geosynthetics in Stream Restoration. (210 VI NEH, August 2007)

Using Garden Roof Systems to Achieve Sustainable Building Envelopes

Transcription:

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

1085 CPD 0010 1085 CPD 0018 FLAGON SV www.flag.it COMPOSITION Synthetic membrane of plasticised PVC with a layer of glass fibre (50 g/m 2 ) inserted for dimensional stability. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Resistant to weathering and ultraviolet rays. UEAtc certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES Resistance to weathering and ultraviolet rays. No dimensional shrinkage Will not rot Resistance to puncturing Adaptability to structural movements Flexibility to low temperatures Vapour permeability AREA OF USE ROOFING Movable Ballast System: - horizontal surfaces without pedestrian traffic ballasted by gravel - horizontal surfaces with pedestrian traffic ballasted by prefabricated square concrete slabs - inverted roof - sandwich roof - vertical details Mechanical fastening system: - vertical details Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SV 120 FLAGON SV 150 FLAGON SV 180 FLAGON SV 200 FLAGON SV 240 Testing method Thickness (mm) 1,2 1,5 1,8 2,0 2,4 UNI EN 1849-2 Weight (Kg/m 2 ) 1,50 1,80 2,15 2,40 2,90 UNI EN 1849-2 Tensile strenght (N/mm 2 ) 9,0 9,0 9,0 9,0 9,0 UNI EN 12311-2 Elongation to break (%) 200 200 200 200 200 UNI EN 12311-2 Tear resistance (N) 110 135 160 170 200 UNI EN 12310-2 Resistance to impact (mm) 450 800 900 1000 1500 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof waterproof UNI EN 1928 meth. B (6 hours at 0,5 MPa) Dimensional stability (%) ± 0,1 ± 0,1 ± 0,1 ± 0,1 ± 0,1 UNI EN 1107-2 after 6 hours at 80 C Resistance to artificial weathering no cracking no cracking no cracking no cracking no cracking UNI EN 1297 Root resistance no penetration no penetration no penetration no penetration no penetration UNI EN 13948 Resistance to hail on rigid substrate (m/s) 25 25 25 25 25 UNI EN 13583 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint of joint of joint Resistance to static punching (kg) 20 20 20 20 20 UNI EN 12730 PRODUCTION STANDARD Thickness (mm) 1,2 1,5 1,8 2,0 2,4 Width (m) 1,60 / 2,10 1,60 / 2,10 1,60 / 2,10 1,60 / 2,10 1,60 / 2,10 Length (m) 20 / 25 20 20 20 20 Colour Light grey ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile - termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk

FLAGON PVC FLAGON SP ROOFING SYNTHETIC MEMBRANES

1085 CPD 0018 FLAGON SP www.flag.it COMPOSITION Synthetic membrane of plasticised PVC with a layer of glass fibre (50 g/m 2 ) inserted for dimensional stability. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Cerisie certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES No dimensional shrinkage Will not rot Resistance to puncturing Adaptability to structural movements Flexibility at low temperatures Vapour permeability Good resistance to hydrocarbons and bacterial attacks Signal red colour AREA OF USE ROOFING Movable Ballast System: - inverted roof - sandwich roof Rigid Ballast System: - pedestrian roof - trafficked roof - roof-garden Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SP 120 FLAGON SP 150 FLAGON SP 180 FLAGON SP 200 FLAGON SP 240 FLAGON SP 300 Testing method Thickness (mm) 1.2 1.5 1.8 2.0 2.4 3.0 UNI EN 1849-2 Weight (Kg/m 2 ) 1.50 1.80 2.15 2.40 2.90 3.65 UNI EN 1849-2 Tensile strenght (N/mm 2 ) 9,0 9,0 9,0 9,0 9,0 9,0 UNI EN 12311-2 Elongation to break (%) 200 200 200 200 200 200 UNI EN 12311-2 Tear resistance (N) 110 135 160 170 200 250 UNI EN 12310-2 Resistance to impact (mm) 450 800 900 1000 1500 1700 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 - 25-25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof waterproof waterproof UNI EN 1928 meth. B (6 hours at 0,5 MPa) Dimensional stability (%) ± 0,1 ± 0,1 ± 0,1 ± 0,1 ± 0,1 ± 0,1 UNI EN 1107-2 after 6 hours at 80 C Root resistance no penetration no penetration no penetration no penetration no penetration no penetration UNI EN 13948 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 - 25-25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint of joint of joint of joint Resistance to static punching (kg) 20 20 20 20 20 20 UNI EN 12316 PRODUCTION STANDARD Thickness (mm) 1,2 1,5 1,8 2,0 2,4 3,0 Width ( m) 1,60 1,60 1,60 1,60 1,60 1,60 Length (m) 20 20 20 20 20 20 Colour Red ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER PVC Flagmetal sheet - perimeter profile - termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk

FLAGON PVC FLAGON SFc ROOFING SYNTHETIC MEMBRANES

1085 CPD 0018 FLAGON SFc www.flag.it COMPOSITION Synthetic membrane of plasticised PVC with the addition of a 50 g/m 2 glass fibre reinforcement for stability and a 200 g/m 2 nonwoven polyester felt support to make the adherence process praticable. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Resistant to weathering and ultraviolet rays. UEAtc certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES High resistance to weathering and ultraviolet rays. No dimensional shrinkage Insensitivity to the hot-cold cycles Resistance to puncturing Possible RAL colour for landscape or architectural purpose AREA OF USE ROOFING Movable Ballast System: - vertical details Mechanical Fastening System: - verticals Fully Adhered System: - fully adhered on insulation boards - fully adhered on traditional reinforced-concrete slab Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SFc 120 FLAGON SFc 150 FLAGON SFc 180 FLAGON SFc 200 FLAGON SFc 240 Testing method Thickness (mm) 1,2 1,5 1,8 2,0 2,4 UNI EN 1849-2 Weight (Kg/m 2 ) 1,70 2,00 2,35 2,60 3,10 UNI EN 1849-2 Tensile strenght (N/5cm) 650 700 800 900 1100 UNI EN 12311-2 Elongation to break (%) 80 80 80 80 80 UNI EN 12311-2 Tear resistance (N) 150 170 180 200 220 UNI EN 12310-2 Resistance to impact (mm) 450 800 900 1000 1500 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof waterproof UNI EN 1928 meth. B (6 hours at 0,5 MPa) Dimensional stability (%) ± 0,1 ± 0,1 ± 0,1 ± 0,1 ± 0,1 UNI EN 1107-2 after 6 hours at 80 C Resistance to artificial weathering no cracking no cracking no cracking no cracking no cracking UNI EN 1297 Root resistance no penetration no penetration no penetration no penetration no penetration UNI EN 13948 Resistance to hail on rigid substrate (m/s) 25 25 25 25 25 UNI EN 13583 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out breaking out UNI EN 12317-2 of joints of joints of joints of joints of joints Resistance to static punching (kg) 20 20 20 20 20 UNI EN 12730 PRODUCTION STANDARD Thickness 1,2 mm 1,5 mm 1,8 mm 2,0 mm 2,4 mm Width 1,60 m 1,60 m 1,60 m 1,60 m 1,60 m Length 20 m 20 m 20 m 20 m 20m Colour Light grey ACCESSORIES SYSTEM FLEXOCOL A89 / FLEXOCOL W (for UK market) FLAGON PVC for detail work (FLAGON S) Prefabbricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile - termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: info@flag--soprema.co.uk

FLAGON PVC FLAGON SFb ROOFING SYNTHETIC MEMBRANES

1085 CPD 0018 COMPOSITION Synthetic membrane of plasticised PVC with the addition of a 50 g/m 2 glass fibre reinforcement for stability and a non-woven polyester felt backing 300 g/m 2. Appropriately the bottom layer is added in order to provide an anti-bitumen layer. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Resistant to weathering and ultraviolet rays. UEAtc certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FLAGON SFb www.flag.it FEATURES High resistance to weathering and ultraviolet rays. No dimensional shrinkage Compatibility with contact with bitumen on the lower layer Insensitivity to the hot-cold cycles Resistance to puncturing Possible RAL colour for landscape or architectural purpose AREA OF USE ROOFING Fully Adhered System: - refurbishment bitumen - adhered in bitumen Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SFb 150 FLAGON SFb 180 FLAGON SFb 200 FLAGON SFb 240 Testing method Thickness (mm) 1,5 1,8 2,0 2,4 UNI EN 1849-2 Weight (Kg/m 2 ) 2,10 2,45 2,70 3,20 UNI EN 1849-2 Tensile strenght (N/5cm) 800 950 1000 1200 UNI EN 12311-2 Elongation to break (%) 80 80 80 80 UNI EN 12311-2 Tear resistance (N) 250 270 300 330 UNI EN 12310-2 Resistance to impact (mm) 850 950 1050 1550 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof UNI EN 1928 met. B ((6 hours at 0,5 MPa)) Dimensional stability (%) ± 0,1 ± 0,1 ± 0,1 ± 0,1 UNI EN 1107-2 after 6 hours at 80 C Resistance to artificial weathering no cracking no cracking no cracking no cracking UNI EN 1297 Root resistance no penetration no penetration no penetration no penetration UNI EN 13948 Resistance to hail on rigid substrate (m/s) 25 25 25 25 UNI EN 13583 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint of joint Resistance to impact (mm) 10 10 10 10 UNI EN 12691 Resistance to static punching (kg) 20 20 20 20 UNI EN 12316730 PRODUCTION STANDARD Thickness 1,5 mm 1,8 mm 2,0 mm 2,4 mm Width 2,10 m 2,10 m 2,10 m 2,10 m Length 20 m 20 m 20 m 20 m Colour Light grey ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile -termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk

FLAGON PVC FLAGON SR ROOFING SYNTHETIC MEMBRANES

1085 CPD 0010 1085 CPD 0018 FLAGON SR www.flag.it COMPOSITION Synthetic membrane of plasticised PVC with signal layer. Reinforced with a polyester mesh. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Resistant to weathering and ultraviolet rays. UEAtc certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES Resistance to wind stress High resistance to weathering and ultraviolet rays. High mechanical resistance. Insensitivity to the hot-cold cycles Resistance to puncturing Possible RAL color for landscape or architectural purpose AREA OF USE ROOFING Mechanical Fastening System: - Mechanical fixing Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SR 120 FLAGON SR 150 FLAGON SR 180 FLAGON SR 200 FLAGON SR 240 Testing method Thickness (mm) 1,2 1,5 1,8 2,0 2,4 UNI EN 1849-2 Weight (Kg/m 2 ) 1,50 1,80 2,15 2,40 2,90 UNI EN 1849-2 Tensile strenght (N/5 cm) 1100 1100 1100 1100 1100 UNI EN 12311-2 Elongation to break (%) 15 15 15 15 15 UNI EN 12311-2 Tear resistance (N) 200 200 200 200 200 UNI EN 12310-2 Resistance to impact (mm) 450 800 900 1000 1500 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof waterproof UNI EN 1928 meth. B (6 hours at 0,5 MPa) Dimensional stability (%) ± 0,5 ± 0,5 ± 0,5 ± 0,5 ± 0,5 UNI EN 1107-2 after 6 hours at 80 C Resistance to artificial weathering no cracking no cracking no cracking no cracking no cracking UNI EN 1297 Root resistance no penetration no penetration no penetration no penetration no penetration UNI EN 13948 Resistance to hail on rigid substrate (m/s) 25 25 25 25 25 UNI EN 13583 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint of joint of joint Resistance to static punching (kg) 20 20 20 20 20 UNI EN 12730 PRODUCTION STANDARD Thickness 1,2 mm 1,5 mm 1,8 mm 2,0 mm 2,4 mm Width 2,10 m 2,10 m 2,10 m 2,10 m 2,10 m Length 25 m 20 m 20 m 20 m 20 m Colour Light grey ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile -termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk

FLAGON PVC FLAGON SRF ROOFING SYNTHETIC MEMBRANES

1085 CPD 0018 FLAGON SRF www.flag.it COMPOSITION Synthetic membrane of plasticised PVC reinforced with a polyester mesh and with a non-woven polyester felt backing of 200 g/m 2. For isolation or cushioning purposes. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Resistant to weathering and ultraviolet rays. Cerisie certified. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES Resistance to wind stress High resistance to weathering and ultraviolet rays. High mechanical resistance. Insensitivity to the hot-cold cycles Resistance to puncturing Possible RAL colour for landscape or architectural purpose AREA OF USE ROOFING Mechanical Fastening System: - Mechanical fixing on incompatible substraigth Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON SRF 120 FLAGON SRF 150 FLAGON SRF 180 FLAGON SRF 200 FLAGON SRF 240 Testing method Thickness (mm) 1,2 1,5 1,8 2,0 2,4 UNI EN 1849-2 Weight (Kg/m 2 ) 1,70 2,00 2,35 2,60 3,10 UNI EN 1849-2 Tensile strenght (N/5 cm) 1100 1100 1100 1100 1100 UNI EN 12311-2 Elongation to break (%) 15 15 15 15 15 UNI EN 12311-2 Tear resistance (N) 200 200 200 200 200 UNI EN 12310-2 Resistance to impact (mm) 450 800 900 1000 1500 UNI EN 12691 Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof waterproof waterproof UNI EN 1928 meth. B (6 hours at 0,5 MPa) Dimensional stability (%) ± 0,5 ± 0,5 ± 0,5 ± 0,5 ± 0,5 UNI EN 1107-2 after 6 hours at 80 C Resistance to artificial weathering no cracking no cracking no cracking no cracking no cracking UNI EN 1297 Root resistance no penetration no penetration no penetration no penetration no penetration UNI EN 13948 Resistance to hail on rigid substrate (m/s) 25 25 25 25 25 UNI EN 13583 Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25-25 - 25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint of joint of joint Resistance to static punching (kg) 20 20 20 20 20 UNI EN 12730 PRODUCTION STANDARD Thickness 1,2 mm 1,5 mm 1,8 mm 2,0 mm 2,4 mm Width 2,10 m 2,10 m 2,10 m 2,10 m 2,10 m Length 25 m 20 m 20 m 20 m 20m Colour Light grey ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile - termination strip - strip FLAGON SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk

FLAGON PVC FLAGON A ROOFING SYNTHETIC MEMBRANES

1085 CPD 0010 FLAGON A www.flag.it COMPOSITION Synthetic single layer membrane of plasticised PVC manufactured with polymeric plasticizers which are resistant to hydrocarbons. Manufactured in UNI EN ISO 9001:2000 (Quality System) and UNI EN ISO 14001:2004 (Environmental System) certified plant. Cerisie certified for hydrocarbons resistance. Laying by installers approved by Flag S.p.A. Finishing and accessories with elements manufactured and approved by Flag S.p.A. FEATURES Resistant to oils and hydrocarbons High mechanical resistance. High puncturing resistance Adaptability to structural movements AREA OF USE ROOFING Rigid Ballast System: - trafficked roof Membrane which is in accordance to the standards PHYSICAL-CHEMICAL PROPERTIES FLAGON A 150 FLAGON A 180 FLAGON A 200 Testing method Thickness (mm) 1,5 1,8 2,0 UNI EN 1849-2 Weight (kg/m 2 ) 1,80 2,15 2,40 UNI EN 1849-2 Tensile strenght (N/mm 2 ) 17,5 17,5 17,5 UNI EN 12311-2 (hourglass test tube) Elongation to break (%) 300 300 300 UNI EN 12311-2 (hourglass test tube) Resistance to impact (mm) 800 900 1100 DIN 16726-5.12 Tear resistance (N) 120 145 160 UNI EN 12310-2 Cold bending ( C) -25-25 - 25 UNI EN 495-5 Hydrostatic pressure resistance waterproof waterproof waterproof UNI EN 1928 met. B (6 hours at 0,5 MPa Dimensional stability (%) ± 2,0 ± 2,0 ± 2,0 UNI EN 1107-2 after 6 hours at 80 C Root resistance no no no UNI EN 13948 penetration penetration penetration Thermal ageing in air after 168 d at 70 C Cold bending ( C) - 25-25 - 25 UNI EN 1296 Peel resistance of joints (N/50 mm) 150 150 150 UNI EN 12316-2 Shear resistance of joints breaking out breaking out breaking out UNI EN 12317-2 of joint of joint of joint Resistance to static punching (kg) 20 20 20 UNI EN 12730 PRODUCTION STANDARD Thickness 1,5 mm 1,8 mm 2,0 mm Width 2,10 m 2,10 m 2,10 m Length 25 m 20 m 20 m Colour Black ACCESSORIES SYSTEM FLAGON PVC for detail work (FLAGON S) Prefabricated accessories (corners, rain water outlet ecc.) FLAGON PVC CLEANER FLEXOCOL V (for vertical surface) / FLEXOCOL C (for UK market) PVC Flagmetal sheet - perimeter profile -termination strip - strip Flagon SEAM PREP Due to its formulation, the liner is NOT subject to the requirements set forth in the EEC 79/831 regulation on dangerous substances. If the product should be disposed of as waste, we recommend sending it to an authorised landfill site or to an incinerator equipped with post-combustion chamber and fume washing system. 1/2009 SOPREMA GROUP Flag S.p.A. - via Industriale dell Isola, 3-24040 Chignolo D Isola (Bergamo) - Italy - T. +39.035.494.09.49 - F. +39.035.494.06.49 - e-mail: info@flag.it Flag Soprema UK Ltd. - Marlborough House, Beacon Hill Road - Beacon Hill - Surrey GU26 6QL - T. +44.1428.604.500 - F. +44.1428.606.898 - e-mail: tony.mellon@flaguk.co.uk