University of Colorado Department of Aerospace Engineering Sciences ASEN Project Definition Document (PDD)

Similar documents
6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

Team Rescue X: Autonomous Firefighting Robot

SEC Signature Process Gas Analyzer

Technical specifications of FT-IR Spectrometer

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

RLDS - Remote LEAK DETECTION SYSTEM

Sensor Report. University of Florida Department of Electrical and Computer Engineering EEL5666 Intelligent Machines Design Laboratory

1.1. SYSTEM MODELING

Maxline 2 Thermal Imaging Solutions for Manufacturing

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

optris TM Temperature Monitor for Infrared Sensors Operators manual

Test Readiness Review

Hunting the Mighty Milliwatt- The next Technology Step

The design of the human body infrared thermometer

The Study of Low-Light Sights Reliability Test System in High and Low Temperature Environment

Temperature Data Logging

GP-B P0321 Rev -2 December 5, 1997

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

United Electric Controls One Series Safety Transmitter Safety Manual

Source Test and Characterization Program

User Detection Sensors

COMPLEX SATELLITE SYSTEMS EVERY SATELLITE IS BORN SOMEWHERE

Nanotechnology-Based Gas Sensors

Chapter 1. Introduction

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Smart Fire Prevention

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Specifications Wavelength Range: 190 nm to 800 nm continuous

Welcome to Micro-Epsilon

Passive Standoff FTIR Detectors as Transducers. Background From radiation to information

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

The new generation of Multi-Gas measurement. Dipl.- Ing (FH) Andreas Hester, SIGAS Corp. Environment protection Personal safety Process control

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Black Body Calibration Source User Manual

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

QUICK BGA2015. Precision BGA Rework System. Features:

Conduction, Convection, and Radiation Lab Page 1 of 5

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Product data sheet Palas Fidas 200 S

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

BGA Rework Station Pro-660

Vacuum drying oven for non-flammable solvents

S ATION EWORK ST BGA R

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Wildland fire phenomenology experiments:

Split Range Control for Mobile Room Heating System

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

IR IN MODERN TECHNOLOGY 1. Infrared Radiation in Modern Technology. Brian D. Dold. Brigham Young University - Idaho

Figure 1-1 Furnace Front Elevation

10 K Airborne Cryocooler and

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

CT398 Heaterstat TM Temperature Controller. Technical User Guide

Air Resource Specialists, Inc.

Digital EPIC 2 Safety manual

REFURBISHED AND 3D MODELED THERMAL VACUUM CHAMBER. A Thesis. presented to. the Faculty of California State University, San Luis Obispo

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

February 21, 2003 Team Page 1

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

INTERNATIONAL JOURNAL OF RESEARCH GRANTHAALAYAH A knowledge Repository

Thermomechanical Fatigue (TMF) Test System

Automated Fire Detection and Suppression in a Retrofitted Tunnel Using Fiber-Optic Linear Heat Detection

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

OVEN INDUSTRIES, INC.

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

Infrared Moisture Balance (FD-800)

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

NEW GENERATION. Efficient use of valuable space INCUBATORS

More Precision. thermometer // Non-contact IR temperature sensors

Bringing Smarts to Methane Emissions Detection

S ATION EWORK ST BGA R

Incorporating Aluminum Honeycomb to Increase Efficiency of U-tube Removable Heat Exchanger

Electrical failure during NPP cable fires

Hunting the Mighty Milliwatt The next Technology Step

HELPCOS THE HELICOPTER BASED PIPELINE CONTROL SYSTEM OF VNG - VERBUNDNETZ GAS AG

The Design of Temperature Control System for Vegetable Greenhouse

Improving Productivity, Quality and Security

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Minco SmartHeat SLT Self-Limiting Thin-Film Heater Technology

PIP PCTPA001 Testing of Process Analyzer Systems

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

INSTRUCTION MANUAL 4-WAY BALL VALVE Digital Manifold

Broadening IR applications through using spectral filters

Perimeter security using Fibre optics

Loop Heat Pipe Wick Fabrication via Additive Manufacturing

Product Training Module: Inertial Measurement Unit 6-D Motion Variant 6DF Series. Copyright 2013 Honeywell International Inc. All rights reserved.

Substation Monitoring System

Variable Temperature Microprobe Systems

Dräger Polytron Pulsar 2 Open Path Gas Detector

Chapter 1 Introduction

C-NRPP Quality Assurance Guidance for Radon Test Devices

Innovation in distillation. PAMv2. Automatic Distillation testing. by Orbis BV

Transcription:

University of Colorado Department of Aerospace Engineering Sciences ASEN 4018 Project Definition Document (PDD) Systematic Testbed Apparatus for Thermal Infrared Sensors (STATIS) Project Customers Name: Joe Lopez, Shane Brown, Hansford Cutlip Address: Ball Aerospace and Technologies Corp. 1600 Commerce St, Boulder, CO 80301 Phone (W): (303) 939-6222 Email: jlopez@ball.com Team Members Cameron Comeau 970-846-6660 cameron.comeau@gmail.com Daniel Flora 303-579-1271 daniel.j.flora@colorado.edu Smith Johnston 281-702-0107 smjo3537@colorado.edu Alexander Potter 651-343-5563 apotter33@gmail.com Maria Rocco 248-912-7367 rocco.n.maria@gmail.com Evan Schomer 303-905-9093 evan.schomer@colorado.edu Dylan Stewart 303-929-4066 dylan.stewart@colorado.edu Sarah Wilson 303-921-7225 sarah.wilson-1@colorado.edu Ashley Zerr 314-608-0316 zerra.cu@gmail.com 1

1.0 Problem or Need Many space systems contain sensors and data acquisition devices crucial to mission success. These sensors need to be able to withstand four main types of stresses presented by the space environment. The trauma of launch, the vacuum of space, extreme temperature ranges, and electromagnetic interference from background radiation and the spacecraft itself. Currently, contact based temperature sensors such as thermocouples take measurements on various surfaces of a spacecraft. The problem presented by contact based sensors is that they require complex wiring systems and flexible circuits that span over moving parts and joints on a space craft. The use of these complex wiring systems requires expensive and time consuming reliability testing, as they present opportunities for single-point failures that can compromise an entire mission. Contact sensors also do not allow for temperature measurements on surfaces where direct contact mares and reduces the overall effectiveness of the surface. Further explanation and examples are presented in Section 2 of this document. Based upon the risk factors presented by contact sensors, it can be deduced that the use of non-contact infrared temperature sensors would be highly beneficial. The intent of STATIS is to design, build and validate the functionality of a test bed that will characterize a range of commercial off the shelf (COTS) non -contact infrared temperature sensors, by testing their accuracy and precision over variable distance and on different target surfaces when compared to contact based temperature sensors, in a simulated space environment. The test bed will be integrated into a Thermal Vacuum Chamber 1, which will represent the vacuum and temperature environment of space. The temperature of 5 different target surfaces will be controllable in the range of 250-350 K, and 4 different COTS non-contact infrared temperature sensors will record measurements over this range. The test bed shall provide the capability to increase the temperature of the target surfaces by 20K/hr and decrease it by 5K/hr through the designed user interface. The test bed shall also provide the capability to vary the distance (0-TBD cm) between the sensors and target surfaces through the designed user interface. The 5 different target surfaces that will be tested are, Chromated Aluminum, Anodized Aluminum, Glass, Graphite Composite (TBD), and Emissive Paint. These target surfaces are being tested because they represent common surfaces on spacecraft, which have different emissivity values. The 4 sensors will be bought with funds directly from STATIS own budget. The prices of COTS non-contact infrared temperature sensors range from 20 to 10,000 dollars (Optris Gmbh, 2014), due to STATIS budget restrictions only 4 will be utilized. The infrared measurements will be compared to data from a contact based temperature sensor. 2.0 Previous Work Infrared (IR) radiometry allows for the measurement of an object s temperature, above absolute zero, from the electromagnetic radiation emitted (emissivity) from its surface. The emissivity depends on the material, its surface properties and geometry, temperature, wavelength, and the measuring arrangement. IR temperature sensors are the preferred temperature measuring device when the temperature of moving objects is required; it is difficult to design a wiring configuration a by-product from conventional contact temperature sensors such as thermocouples compatible with a system involved with a dynamic event: assembly lines, rotating joints, etc. Infrared temperature sensors are being employed in robotic welding where by its very nature the melting point exceeds the temperature of all metals (Luma Sense Technologies, 2014). Additionally IR sensors have found their way into mechanized food production where items pass by the sensors moving at several miles per hour, leaving only a fraction of a second for the sensor to check temperature (Thermo Works, 2014). For aerospace applications, conventional contact temperature sensors, such as thermocouples, increase production times because the wiring attaching the sensors must be properly designed to prevent fraying and meet military/nasa specifications (Crimping, 2011). The Visible Infrared Imaging Radiometer Suite (VIIRS) could have benefited from a non-contact IR temperature sensor (Visible, 2014). VIIRS has a rotating telescope assembly and a half angle mirror mechanism whose temperature is desired in order to validate optics outputs and other data. Because of the 1 Thermal Vacuum Chamber: Provides a vacuum environment of 1e-5 Torr while maintaining a temperature that allows the sensors to be tested within the suppliers recommended operating range. The size specifications of this Thermal Vacuum Chamber are still to be determined until a specific chamber is chosen. 2

dynamic circumstances involved with the rotating telescope and half angle mirror mechanism, an IR temperature sensor could have reduced the risk of the mission by validating temperature tests in vacuum chambers, on-orbit temperature monitoring, or validate component capability (temperature tolerance verification, mechanical optimization, etc.). Reducing risk would have reduced the cost of the project, or would have allowed for the allocation of resources to be placed elsewhere. 3.0 Specific Objectives Levels of success were created in order to break down different aspects of the test bed, these are shown below in Table 1. While STATIS will be designing the components to achieve Level 3 success, should unforeseen issues arise, the project has the ability to be scaled back to still achieve Level 2 or Level 1 success. The project is being designed to go into a TBD thermal vacuum chamber at Ball, therefore, Level 3 revolves around the fact that everything must comply with the provided Integration Control Document (ICD). Should STATIS not be able to acquire time in the thermal vacuum chamber, success can still be achieved for all criteria by demonstrating the functionality in ambient conditions. Table 1: Levels of Success Criteria Environment Level 1 Ambient Level 2 - Level 3 TVAC Data Acquisition Acquire data from temp sensors (Contact sensors at both IR and target plus data from IR sensors themselves) Acquire data from temp, distance, and target selection sensors Electronic ICD compliance of all sensors Temp Control IR Sensors Uncontrolled Command and control sensor temp to set values between 275-325K to within +1 K Command and control sensor temp to set values between 275-325K to within +1 K with a stability of +1K Temp Control Target Command temp to range of ambient - 350K Command and control target temp to set values between 250-350K to within +1 K Command and control target temp to set values between 250-350K to within +1 K with a stability of +0.1K Distance Control Manually be able to change and measure distance from IR sensor to target in between each test series Target Selection Manually change the five targets in between test series IR Sensors One IR sensor per test series with the capability of collecting temp data from given target - - - Using software, mechanically change and digitally measure the distance from IR sensor to target from 7-76mm as part of the test series. Using software control, mechanically switch between five targets during the test series Four IR sensors per test series with the capability of collecting temp data from given target 4.0 Functional Requirements 4.1 Functional Block Diagram Once the test bed is installed inside and the thermal chamber has been pumped down to a pressure less than 1.0e -5 torr, the tester will initiate a set of commands from the control software of the test station computer. The commands will consist of a target temperature and sensor temperature commands (in the range of 250-350 K and 275-325 K respectively), a target selection (5 target materials), and a separation distance command in the range of 0-TBD cm. This information will travel by wire to the digital-to-analog converter (DAC) through the test chamber cable port. The DAC system will take the temperature, target, and distance commands and supply the corresponding voltage inputs to the heaters (target and sensor), target selection system, and distance control system, respectively. The target and sensor housings will connect to the TVAC chiller plate (TBD K) to dump heat and maintain a constant temperature. Once the selected target material is at the commanded temperature and distance, measurements will be taken from the IR sensor at a frequency of TBD Hz and sent to the analog-to-digital converter (ADC). Contact temperature sensors on the IR sensor and on the target material will also send reference temperature data to the ADC at a rate of TBD Hz. The distance control system will provide distance measurements at the same TBD Hz rate. The local ADC will continuously convert and communicate the acquired data back to the test computer, where the data will be processed and stored. This data will be analyzed by the control software to provide closed-loop feedback control of the target and sensor thermal control systems, distance control system, and target selection system. Once 300 seconds of data are collected from the sensor at a set temperature, distance, and target, (sufficient 3

time to monitor sensor drift) the tester will modify any one of these parameters via an input command to the control software, and data collection will repeat. A depiction of this process is shown in Figure 1. Figure 1: Functional Block Diagram 4.2 Concept of Operations The concept of operations depicted in Figure 2 shows the testing procedure involved in operating STATIS and the future goals of the product upon completion. The test bed will be loaded with 4 sensors (exact models TBD) and 5 target surfaces aforementioned in Section 1 and integrated into the thermal vacuum chamber. Integration requires wiring into the thermal vacuum, exact requirements TBD based on specifications of the TVAC to be used at Ball s facilities. The chamber will be de-pressurized, and the user will initiate temperature data collection. Each sensor will be tested simultaneously. The materials will be cycled such that each sensor will record data from each material. Distance between the sensors and materials will be altered and temperatures of the materials will be modified from 250 K to 350 K based on the rates provided in Section 1. A contact based sensor will supply a temperature truth reference of the materials which will provide a benchmark from which comparisons can be made to the experimental data recorded. The data will be compared based on a common clock to ensure data corresponds directly to the truth reference. Upon completion of the STATIS project, a test report summarizing the results and possible sensor recommendations will be delivered to the customer. Additional tests will be performed by the customer to further research sensor capabilities for space use. 4

Figure 2: Concept of Operations 5.0 Critical Project Elements CPE.1 Data Collection: The test bed must be able to collect and store useful data while testing the IR temperature sensors. If the test bed is unable to store data about the IR sensors performance then the test bed provides little functionality to the customer. CPE.2 Sensor Selection: An important part of the project is selecting off-the-shelf IR temperature sensors that meet initial requirements to be tested in the TVAC environment. The sensors must meet the resolution and accuracy requirements set by the customer. This also means they will have to withstand the manufacturer operating temperature limits and TVAC outgassing requirements. CPE.3 Test Bed Functionality: The test bed must be able to give accurate performance metrics of the IR sensors including accurate and precise temperatures of the target materials and IR sensors and also accurate measurements of the distance between the targets and the IR sensors. These metrics need to be accurate so that the customer can effectively assess the performance of the IR sensors under test. CPE.4 Thermal Model: Since the target materials temperature must change within a specific timeframe, a thermal model must be developed to determine what hardware is necessary to meet the requirements for heat exchange. CPE.5 Electrical Model: The electrical system must be able to handle the data needs of the test bed in terms of sample rates and feedback control. An electrical model must be created to determine what hardware can handle the requirements of the system. CPE.6 Thermal Control: The test bed targets must be heated at certain rates which may require difficult to design hardware to meet these requirements. 6.0 Team Skills and Interests Critical Project Elements Thermal Control Team Members and Associated Skills/Interests Ashley: experience in theoretical thermal control and interested in the thermal aspect. Sarah: Interested in the design and implementation of feedback/control loops in aerospace applications. Dylan: Experience in control system design and thermal system modeling. 5

Thermal Models Electrical Models Sensor Selection Data Collection Test Bed Functionality 7.0 Resources Critical Project Elements Resources Needed Sources Available Thermal Control Control system for maintaining and controlling the temperatures of the sensors, TVAC, and the target surfaces. Thermal Models Electrical Models Sensor Selection Data Collection Test Bed Functionality Maria: theoretical experience with thermal models. Dan: Experience with CAD software, interested in developing 3D model of test bed components for thermal modeling. Dylan: Experience in analytical modeling of dynamic systems. Smith: Interested in financials as well as electronics. Dylan: Interested in electronic design and hardware control systems. Evan: two years of designing cubesat avionics, internship with Ball Aerospace working on EMI susceptibility analysis Sarah: Passion for electronic component design previous experience with micro-avionic component design. Eager to learn more about electronics and data budgeting. Maria: Interest in trade studies and research into IR sensor capabilities Smith: Interested in financials and sensor implementation. Alexander: Interest in finding/using/modifying commercial off the shelf IR sensors for use in space applications Cameron: minoring in computer science and have an interest in developing embedded systems Dylan: Interested and experienced in software development and data analysis. Evan: two years of designing cubesat avionics including data budgeting, internship with Ball Aerospace working on EGSE software Ashley: one year full time job experience creating, testing and operating test beds for rockets and multi-mission software. Dylan: Interest in system integration. Experience in multi-system sequencing. Dan: Interested in systems integration and testing. Cameron: have experience in fabrication and like to get my hands dirty Alexander: Interest in mechanical component design, studying structures for BS/MS. Access to Thermal Modeling software. Understanding of heat transfer between components in a vacuum. Access to circuit analysis software. Understanding of proper DAQ protocol. Understanding of current infrared sensor technologies available on the market today. Understanding of the data budget for each component, DAQ software. Control system for maintaining and controlling the distance between sensors and target materials. Subsystem integration between project components. Control system for target selection. Dale Lawrence, Shane Brown, XinLin Li. Guidance from customers (Hansford Cutlip, Shane Brown), CU faculty (Xinlin Li, Jelliffe Jackson). ITLL Lab Stations and Software. Interface Control Document of TVAC provided by Shane Brown (TBD). Trudy Schwartz. Guidance from customers (Hansford Cutlip, Shane Brown, Joe Lopez) Sensor data sheets and list of materials from manufactures. ITLL Lab Stations and Software. Interface Control Document of TVAC provided by Shane Brown (TBD). Trudy Schwartz. Dale Lawrence, Shane Brown, Matt Rhode, Joe Lopez. 6

8.0 References Crimping, interconnecting cables, harnesses, and wiring. (2011, March 29). Retrieved September 14, 2014, from http://www.hq.nasa.gov/office/codeq/doctree/87394.pdf Luma Sense Technologies. (2014, 09 10). Retrieved from Luma Sense Technologies: http://www.lumasenseinc.com/en/solutions/industrial/metal-processing/induction-tubewelding.html Optris Gmbh, F.-B.-S. (2014). Infrared Thermometer PI160. Berlin, Germany: Optiris Product Brochure. Thermo Works. (2014, 09 10). Retrieved from Thermo Works: http://www.thermoworks.com/products/ir/ Visible Infrared Imaging Radiometer Suite (VIIRS). (2014, September 14). Retrieved September 15, 2014, from http://npp.gsfc.nasa.gov/viirs.html 7