INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Similar documents
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

Demand Control Kitchen Ventilation Cameron Ritzenthaler, Air Solutions & Balancing, LLC

David Reynolds, Business Development Manager. Halton Group Foodservice Division

DEMAND CONTROL KITCHEN VENTILATION

Revolving Oven Gas Wood Model 140

DEMAND CONTROL KITCHEN VENTILATION

FOOD SERVICE EQUIPMENT REBATES

EC Fans Growing in Popularity

Demand-Controlled Ventilation for Commercial Kitchen Ventilation

Sustainability Best Practices for HVAC Retrofits. Cal Poly State University, San Luis Obispo. Presented to the UC/CSU/CCC Sustainability Conference

GreenJet Transfer Fans

Kitchen Ventilation & HVAC Efficiency Solutions. Click to download presenta1on

Test, Adjust, and Balance Services Submittal

COMcheck Software Version Mechanical Compliance Certificate

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION

Variable Ventilation for the Kitchen:

Allure EC-Smart-Air Series Communicating sensors

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Energy Recovery with Cooling and Heating

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Illini Union Exhaust Hood Conversion University of Illinois at Urbana-Champaign U12241

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

COMMERCIAL KITCHEN FIRE SAFETY

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Stulz CyberMOD EC Fan Retrofit Kit Switch & Save

COMcheck Software Version Mechanical Compliance Certificate

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Energy Saving Results for Cheetah. Cheetah Energy Saving in Commercial Kitchens

Improved Thermal Comfort & Energy Efficiency with low-pressure VAV diffusion design

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

Demand Controlled Kitchen Ventilation (DCKV) [Strategy]

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

How to Cut Chiller Energy Costs by 30%

Customer Advanced Technologies Program Technology Evaluation Report

Duo-Aire. VAC-1 Vertical Air Curtain Wall Hood Single Plenum

Job Name Control Systems Description Date

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

The secrets to our success? Not so secret. How do you keep customers loyal? Keep giving them what they need. Exclusive technical innovations.

Guide for Air Treatment with Ozone for Restaurants and Commercial Kitchens

NOW AUSTRALIA S NUMBER ONE CHOICE IN COMMERCIAL MICROWAVE OVENS FSM

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

Hybrid Series. Innovative Heating Solutions continentalheatingandcooling.com

Excellent Ventilation for Professional Kitchens

TESTING, ADJUSTING AND BALANCING

Dee Fly Cube 300 and 370. Heat Recovery ventilation

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

M.A.R.V.E.L. Intelligent Demand Controlled Ventilation System for Professional Galleys. Enabling Wellbeing

MAXA-MI$ER Energy recovery solutions

Demand-Controlled Ventilation For Commercial Kitchens

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

SECTION COMMERCIAL-KITCHEN HOODS

Paul McCown, PE, CEM, LEED AP, CxA Sr. Mechanical Engineer SSRCx, LLC Nashville, TN USA

LACLEDE ENERGY EFFICIENCY PROGRAMS

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

CHAPTER 5: EXHAUST SYSTEMS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Clean. Easy. COMPLIANT.

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Exhibit J. Subcontract Agreement No.

SCRUBBOX. For commercial kitchens & industrial exhaust air cleaning systems. Electrostatic Precipitators

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

DEMAND CONTROLLED VENTILATION WITHOUT WIRES

Energy Recovery Ventilators MCV CORE Series. Customer for Life: Power of Connections Johnson Controls, Inc Page 1

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

PC-120 FLATWORK IRONERS. Advanced ironers for superior productivity, efficiency and quality results.

Energy Efficient Fan and Dust Collection Systems

COMcheck Software Version Mechanical Compliance Certificate

NATURAL GAS ENERGY ANALYSIS PROGRAM (NGEA)

SECTION PLUMBING/HVAC FINAL TESTING, ADJUSTING AND BALANCING

Benefits of ENERGY STAR Commercial Water Heaters in the Food Service Industry

The Corona air inlet TECHNICAL SPECIFICATIONS

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

THE ULTIMATE ROOFTOP SOLUTION

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Aspiration Detection.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

City of Duluth Festival Center 04/25

Technical Assignment 3 11/15/04. Executive Summary

Manual Supplement. Product/System Title: Static Pressure Controller. Contents of this manual supplement include:

MicroTech Self-Contained Air Conditioning System

Demand Control Ventilation What, When and Where?

CHEMICAL FUME HOOD PROGRAM

Transcription:

INTELLINOX DEMAND CONTROL KITCHEN VENTILATION

COMMERCIAL KITCHEN VENTILATION EXPERTS FOR OVER 25 YEARS

WHO WE ARE WE REALLY UNDERSTAND YOUR KITCHEN Extensive knowledge with all kitchen hood manufacturers including design, installation, and sales of hood systems. WE KNOW ENERGY EFFICIENCY The Intellinox commercial kitchen ventilation controls save energy, operational costs, and help contribute to a greener environment. WE REALLY UNDERSTAND AIR FLOW IN YOUR KITCHEN NEBB certified testing, adjusting, and balancing firm with a specialty in commercial kitchens.

ALL OR NOTHING VENTILATION EXHAUST & MAKE-UP AIR

WHAT S NEW WITH INTELLINOX? Addition of new components mean a solution for every commercial kitchen Multiple cooking modes yield lower average fan speeds Improved sensor durability & maintenance Lower cost on materials and installation Automatic on & off feature allows for greater energy savings

KEY COMPONENTS: TEMPERATURE SENSOR Senses temperature changes in the hood & ductwork Used for both cooking & auto on / off capability Programmable temperature spans Ease of installation in hood ductwork or top of hood Available in both standard and EMT model

KEY COMPONENTS: OPTIC SENSOR Iris Blue Optical Sensors Sensing smoke & steam in the hood Blue Light is able to detect smaller smoke & steam particles Available in both standard & EMT model Ease of installation Auto calibration Ease of cleaning & responsiveness

KEY COMPONENTS: MODULATING DAMPER Retrofitted into pre-existing ductwork Adjustable to fit existing conditions Fully-closed to fully-open in under 4 seconds Access panel installed when needed Responsible for additional energy savings Option on Intellinox-PLUS

VARIABLE FREQUENCY DRIVE (VFD) OPTIONS YASKAWA Z1000 with bypass YASKAWA without bypass ANY VFD MANUFACTURER WILL BE COMPATIBLE

PUTTING IT ALL TOGETHER

PUTTING IT ALL TOGETHER

INTELLINOX KEY FEATURES Temperature sensors, Optic sensors & Modulating Dampers Prep Mode, Cooking Mode, Cooldown, & Idle Constant auto calibration of Optic sensors Automatic On, Off & sensor monitoring Ease of maintenance & cleaning Integration with Building Automation System Versatility of component installation

APPLICATIONS BOTH NEW CONSTRUCTION & RETROFIT ALL HOOD SIZES & TYPES ALL EXHAUST FANS & MAKE-UP AIR UNITS WITH 3-PHASE MOTORS

CODES & REGULATIONS STANDARDS & COMPLIANCE 3.3.35.2 Limited combustible material 7.3.4 Access panel for dampers 7.5.4 Devices with duct penetration listed UL1978 8.2.1.1 Min air velocity 500ft/min in any duct 8.2.2.2 Air balancing 8.2.2.3 Lower exhaust air volume when not cooking 9.1.2 Listed dampers permitted in ducts UL710 Exhaust hoods for commercial equipment UL1978 Grease ducts UL2017 General-purpose signaling devices and systems CSA508A Industrial control equipment NSF-2 Commercial food equipment FCC part 15 subpart B Unintentional radiators CE 2004/108/EC Electromagnetic compatibility

ENERGY STAR 2015 EMERGING TECHNOLOGY AWARD

ENERGY SAVINGS & BENEFITS Average new fan speed of 65% (Temp & Optics) Average new fan speed of 50% (Temp, Optics & MD) Conditional air savings Up to 70% Average payback 1 to 3 years Improved Safety with auto on & off capability Improved Comfort with reduced hood air noise Sustainability by helping to achieve LEED credits Can qualify for local Utility Rebates

CASE STUDY: RESTAURANT SCENARIO Local restaurant 3 hoods 3 exhaust fans 16 hour / day runtime Retrofit Install time: 2 nights

CASE STUDY: RESTAURANT SCENARIO Installed cost: $13,500.00 Motor operating savings: $1,851.00/year Heating savings: $3,383.00/year Cooling savings: $1,971.00/year TOTAL SAVINGS: PAYBACK PERIOD: $7,205.00/year 1.9 years

AIR SOLUTIONS & BALANCING

WHAT WE OFFER Offer complete turnkey installations of Intellinox systems All in-house labor by licensed electricians Complimentary walkthroughs & site visits In-house design engineering services Free energy analyses Over 10 years demand ventilation installation experience Hood performance testing

CONTACT AIR SOLUTIONS CAMERON RITZENTHALER Cameron@USAbalancing.com T 603-262-9292 USAbalancing.com 40 King Street Unit 1, Auburn NH