REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045

Similar documents
REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT Dialight, 1501 Route 34 South, Farmingdale, NJ 07727

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT COMMERCENTRE DRIVE, LAKE FOREST, CA 92630

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

Technical-Report for SL Lamp 5 W

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

SIGMADEK, LTD. FIRE TEST REPORT

REPORT NUMBER: MID-003r1 ORIGINAL ISSUE DATE: March 11, 2015 Revised Date: March 20, 2015

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

In Situ Temperature Measurement

FLASHLIGHT ANSI STANDARDS

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

SECTION INTERIOR LIGHTING

Fast. Precise. Versatile. UL Lighting Sciences

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: AOK)

NVLAP LAB CODE For. Shen Zhen Green Works Lighting Co., Ltd. Floor 4, Bldg. A, No. 36-8, Yingtai Road,Dalang, Longhua, SHENZHEN,China.

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

NVLAP LAB CODE In Situ Temperature Measurement Test Report. For SHENZHEN SUNPER OPTO CO.,LTD. (Brand Name: SUNPER)

NVLAP LAB CODE ISTMT Test Report. For IROCO AOTOM (HUBEI) PHOTOELECTRICITY CO., LTD

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

In Situ Temperature Measurement Test Report. For. AOK LED Light Company Limited. (Brand Name: ) Outdoor Pole/Arm-Mounted Area and Roadway Luminaires

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

Safety Certification of Solid-State Lighting Products. September 23, 2009 Todd Straka Director - Lighting Services

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

E10 & L9 Low Wattage Light Cone Data

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

FUNDERMAX GMBH FIRE TEST REPORT

lumenalpha downlight Specification Sheet

Lighting Measurement Solutions

Product Description. Features. Table of Contents. CLM-DS08 Rev 11. Product family data sheet. Source with

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Technical application guide

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Optics & Radiometry Laboratory

FPLHB - Fidelux Premier Linear Highbay

Technical application guide

January 26, Mr. Larry Sunshine Bentax USA 418 Meadow Street Fairfield CT Dear Mr. Sunshine:

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Product Specifications MaxLumen MRI LED Diffused Lighting

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

Rating. Class I Div II

SDL4 LED Strip Diffused Lens

LED Reliability and Current Standards for Measurement

Models: LED-8088M40/LED-8088M40C,LED-8088E40/LED-8088E40C,LED-8088M57 /LED-8088M57C,LED-8088E57/LED-8088E57C

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

ENGINEERING EVALUATION

Optical Testing Report for 46 Lamp Sample Sets

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Dimensions (111mm) (111mm) 3 (76mm)

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

CONTENTS. Draft Minimum Energy Performance Standards for LED Lighting V6 14 November

Table of Contents. Product Description. Features. CLM-DS08 Rev 9A. Product family data sheet. Source with. Characteristics - WhiteLight Dimming...

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Product Specifications MaxLumen MRI LED Diffused Lighting

2018 Midstream Lighting Product Catalog

Optical Measurement Techniques for LED Clusters and LED Safety

Philips MASTER LEDbulb DIM W & W E27/B K 230 V

Refrigerating Appliance DOE Test Report

Alliance 4 - ALI4 LED 4 Linear High Bay

DRAFT. Models: LED-8085M30, LED-8085M30C; LED-8085M42, LED-8085M42C; LED-8085M57, LED-8085M57C

Fortimo LED Line High Flux Module

BAS SDL8' LED Strip Diffused Lens

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

ENERGY STAR Program Requirements for Residential Light Fixtures. Eligibility Criteria Version 4.2. Table of Contents

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

LHBXD LED Linear High Bay

CLARA AC Crystal CLARA AC 50. LED-modules for downlight. A qualified solution to replace and exceed Halogen solutions in Downlights.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

2018 Instant Lighting Rebates Product Catalog

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

Philips MASTER LEDbulb 7-40 W and W E27/B K 230 V

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

BAS SFP22 Edge-lit LED Panel

ELLA ID. High CRI, High lm/w OptoDrive LED-module

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

CDL8 LED Architectural

Cree XLamp MT-G MR16 Reference Design

OUTPUT RANGE: VIVID SERIES

Transcription:

REPORT 3933 US ROUTE 11, CORTLAND, NEW YORK 13045 FOR THE SCOPE OF. ACCREDITATION UNDER NVLAP LAB CODE 100402-0.. Project No. G101537614 Date: April 8, 2014 REPORT NO. G101537614CRT-005 TEST OF ONE LED HIGH BAY MODEL NO. PROCTV22LEDGV235W35KEX/PR22 RENDERED TO SPECTRUM LIGHTING 994 JEFFERSON ST FALL RIVER, MA 02721 TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number Q500506321. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-2008: Electrical and Photometric Measurements of Solid State Lighting ANSI NEMA ANSLG C78.377: 2012: Specifications of the Chromaticity of Solid State Lighting Products Energy Star Manufacturer s Guide Version 2.1 (2010): Guide for Qualifying Solid State Lighting Luminaires DESCRIPTION OF SAMPLE: DATES OF TESTS: The client submitted one production sample of model number PROCTV22LEDGV235W35KEX/PR22. The sample was received by Intertek on March 27, 2014, in undamaged condition and one sample was tested as received. The sample designation was CRT1403271056-001. April 7, 2014 through April 7, 2014. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.

SUMMARY Model No.: Description: PROCTV22LEDGV235W35KEX/PR22 LED HIGH BAY Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW) Sphere 20831 227.3 91.65 Result Goniometer 21191 227.2 93.27 Criteria Result Power Factor at 120Vac 0.997 Power Factor at 277Vac 0.952 Current ATHD % at 120Vac 4.92 Current ATHD % at 277Vac 9.65 Correlated Color Temperature (CCT - K) 4097 Color Rendering Index (CRI - Ra) 85.9 Color Rendering Index (CRI - R9) 27.6 DUV 0.001 Chromaticity Coordinate (x) 0.377 Chromaticity Coordinate (y) 0.378 Chromaticity Coordinate (u') 0.222 Chromaticity Coordinate (v') 0.502 Maximum In-Situ Source Temperature Point ( C) 78.8 EQUIPMENT LIST Equipment Used Yokogawa Power Analyzer LABSPHERE 3M Fluke Temp Meter Elgar Power Supply Extech Hygro-Thermometer SORENSEN POWER SUPPLY NIST Spectral Flux Standard Source LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer ExTech Hygro Thermometer Fisher Scientific M-D Building Products Cole Parmer Hygro-thermometer Fluke Multimeter Fluke Temp Meter Model Number WT1600 W/ CDS 1100 53 II CW1251 445703 XFR 150-8 RF1024 6440 CW1251 WT210 445703 14-649-9 Smart Tool 03313-85 87 53 II Control Number E474 N307 T1318 --- T1366 --- N/A --- --- E464 T1357 N1405 L112 T1469 E259 D587 Last Date Calibrated 03/07/14 03/21/14 11/27/13 09/18/10 03/25/14 04/17/13 11/25/13 08/13/13 03/15/14 05/31/13 03/20/14 04/24/13 Calibration Due Date 03/07/15 03/21/15 11/27/14 100 hrs of use 04/25/14 04/17/14 11/25/14 08/13/14 03/15/15 05/31/14 03/20/15 04/24/14 Report No. G101537614CRT-005 2 of 8 Date: April 8, 2014

TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Integrating Sphere Method A Labsphere Model CDS 1100 CCD Array Spectroradiometer and Two Meter or Ten Foot Sphere was used to measure correlated color temperature, chromaticity coordinates, and the color rendering index for each SSL unit. Ambient temperature was measured at a position inside the sphere. Each SSL unit was operated on the client provided driver at the rated input voltage in its designated orientation. Each SSL unit was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. The calibration of the sphere photometer-spectroradiometer system is traceable to the National Institute of Standards and Technology. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 6440 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Xitron or Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. In-Situ Maximum Measured Power Supply Case and LED Source Point Temperature Power supply case and/or LED source operating temperature measurements were taken on one test sample per model with a thermocouple and Fluke 87 temperature meter. The SSL sample was allowed to reach thermal equilibrium for seven and a half hours before measurements were taken. Power supply or source temperature measurements were measured at the TMPPS or TS point as indicated by the included diagram in accordance with manufacturers declared hot spot location, or at a hot spot location found with a thermal camera when no diagram from the manufacturer is given. The maximum temperature was recorded for the sample. A simulated ceiling or other enclosure may be used in accordance to UL 1598 or UL 153 as applicable. Report No. G101537614CRT-005 3 of 8 Date: April 8, 2014

RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) - Integrating Sphere Method Input Input Input Input Current Intertek Sample No. Base Orientation Voltage {Vac} Current (ma) Power (Watts) Power Factor ATHD (%) CRT1403271056-001 UP 120.0 1900 227.3 0.997 4.92 277.0 851.5 224.5 0.952 9.65 Luminous Flux (Lumens) 20831 Lumen Efficacy (LPW) 91.65 Correlated Color Temperature (K) 4097 CRI CRI -Ra -R9 DUV 85.9 27.6 0.001 CIE 31 Chromaticity Coordinate (x) 0.377 CIE 31 Chromaticity Coordinate (y) 0.378 CIE 76 Chromaticity Coordinate (u ) 0.222 CIE 76 Chromaticity Coordinate (v ) 0.502 Spectral Distribution over Visible Wavelengths nm mw/nm nm mw/nm nm mw/nm nm mw/nm nm 350 4.484 440 144.1 530 238.9 620 285.7 710 355 2.731 445 219.2 535 246.8 625 273.9 715 360 2.956 450 310.8 540 258.6 630 260.9 720 365 2.842 455 336.2 545 270.1 635 248.4 725 370 2.916 460 264.8 550 279.7 640 236.1 730 375 3.269 465 202.1 555 288.9 645 222.3 735 380 2.289 470 174.6 560 297.6 650 206.9 740 385 2.915 475 146.9 565 303.3 655 190.8 745 390 2.533 480 133.2 570 306.8 660 174.6 750 395 2.856 485 137.7 575 309.2 665 158.3 755 400 405 2.850 3.638 490 495 147.9 159.7 580 585 315.5 318.4 670 675 143.2 127.3 760 765 410 5.623 500 175.1 590 320.2 680 113.0 770 415 9.795 505 188.9 595 321.4 685 100.0 775 18.350 510 201.9 600 321.1 690 88.0 780 425 32.210 515 210.9 605 315.2 695 77.3 430 55.340 520 220.5 610 307.0 700 67.6 435 92.270 525 229.1 615 297.7 705 58.9 mw/nm 51.000 44.130 37.990 32.680 28.030 24.350 20.940 18.410 15.870 13.610 11.890 10.310 8.931 7.749 6.736 (mw/nm) Spectral Data Over Visible Wavelengths 400.000 350.000 300.000 250.000 200.000 150.000 100.000 50.000 0.000 350 400 450 500 550 600 650 700 750 800 Nanometers Report No. G101537614CRT-005 4 of 8 Date: April 8, 2014

RESULTS OF TEST (cont'd) Photometric and Electrical Measurements at Ambient Temperature (25 C +/- 1 C) Distribution Method Intertek Sample No. CRT1403271056-001 Base Orientation UP Input Voltage {Vac} 120.1 Input Current (ma) 1897 Input Power (Watts) 227.2 Input Power Factor 0.998 Absolute Luminous Flux (Lumens) 21191 Lumen Efficacy (Lumens Per Watt) 93.27 Intensity (Candlepower) Summary at 25 C - Candelas Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0 17650 17930 18289 17054 13616 10586 7036 3252 1890 920 749 578 379 334 294 227 136 92 78 88 99 106 107 116 128 142 162 188 226 276 313 326 335 341 376 22.5 17499 17202 17422 16601 13957 10753 6488 3848 1751 957 762 610 349 275 201 45 17429 16790 16873 16335 14333 10906 6255 4140 1701 998 771 601 197 158 163 108 122 82 81 86 86 96 96 104 110 107 112 116 123 132 139 148 160 171 180 192 197 217 215 268 255 316 314 323 326 321 325 341 381 444 367 277 334 386 67.5 17594 17527 17611 16602 13954 10784 6756 3745 1797 966 775 607 345 276 206 156 102 77 89 103 107 108 117 131 150 169 193 219 263 311 320 323 337 385 90 17661 17900 18250 17103 13600 10517 6744 3124 1709 918 748 581 387 333 288 221 132 90 76 89 108 111 110 116 129 142 160 187 224 272 311 316 328 341 375 Report No. G101537614CRT-005 5 of 8 Date: April 8, 2014

RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 10 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 25 C Zonal Lumens and Percentages at 25 C Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Lumens 12916 17124 19328 898.6 20226 965.0 21191 % Luminaire 61.0 80.8 91.2 4.2 95.4 4.6 100.0 Zone 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 Lumens 1668 4907 6341 8 1516 687.7 436.9 294.3 167.4 93.7 104.6 109.7 119.0 131.3 138.7 140.7 92.5 34.8 % Luminaire 7.9 23.2 29.9 19.9 7.2 3.2 2.1 1.4 0.8 0.4 0.5 0.5 0.6 0.6 0.7 0.7 0.4 0.2 Report No. G101537614CRT-005 6 of 8 Date: April 8, 2014

RESULTS OF TEST (cont'd) In-Situ Maximum Measured LED Source Temperature Manufacturer Supplied Documentation: X Maximum Junction Temperature from LED specification (Tj) = 110 C Thermal Resistance Formula from LED specification = 20 C/W Maximum Forward Voltage (Vf) from LED specification = 3.3V Measured LED Current = 88.7mA Calculated LED Wattage = Vf x Measured LED Current = 0.293W Maximum Source Temperature (Ts) = Tj (LED Wattage x Thermal Resistance) = 104.1 C Maximum Measured Manufacturer Designated Source Temperature Maximum Measured Maximum Rated Sample No. Source Temperature ( C) Location Source Temperature ( C) CRT1403271056-001 78.8 Per diagram 104.1 Report No. G101537614CRT-005 7 of 8 Date: April 8, 2014

CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Gerald Gray Associate Engineer Lighting Division Jacki Swiernik Staff Engineer Lighting Division Attachment: None Report No. G101537614CRT-005 8 of 8 Date: April 8, 2014