MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

Similar documents
MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

TECHNICAL DATA. Page 1 of 5

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

STANDARD/quick. Sprinkler 42o. August 8, 2011

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

microfast quick response Pendent sprinkler VK302 (K5.6)

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) TECHNICAL DATA

December 14, 2015 Page 1 of 7 TECHNICAL DATA

Standard Spray concealed horizontal sidewall sprinkler VK481

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

Quick response concealed horizontal sidewall sprinkler VK481

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

micromatic Standard response Horizontal Sidewall sprinkler

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

sprinkler vk538 (K11.2)

STANDARD RESPONSE DRY PENDENT STANDARD ORIFICE SPRINKLERS TECHNICAL DATA

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

MICROMATIC STANDARD RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK104 (K5.6) TECHNICAL DATA

quick response extra-large orifice upright sprinkler vk531 (storage-density/area)

MICROMATIC STANDARD RESPONSE PENDENT SPRINKLER VK102 (K5.6) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

standard response dry horizontal sidewall sprinklers

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

TECHNICAL DATA. The Web site may include a more recent Frame Casting: Brass UNS-C84400

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK120 (K8.0) TECHNICAL DATA

TECHNICAL DATA STANDARD/QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD ELO PENDENT SPRINKLER VK608

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

micromatic standard response Upright sprinkler VK100 (K5.6)

microfast quick response extended coverage hsw sprinkler vk606

TECHNICAL DATA OBSOLETE

micromatic Standard response Horizontal Sidewall sprinkler

microfast and microfasthp quick conventional sprinklers

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

standard response/ quick response extended coverage

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

micromatic standard sprinkler VK003 (K2.8) 3. technical data Page 1 of 7

microfast sr/qr extended coverage pendent sprinkler

standard response Fusible Link Upright sprinkler VK204 (K8.0)

MicrofastHP QUICK RESPONSE HORIZONTAL SIDEWALL HIGH PRESSURE SPRINKLER VK319 (K5.6) TECHNICAL DATA

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

standard response elo upright sprinkler

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

MICROMATIC STANDARD RESPONSE CONVENTIONAL SPRINKLER VK118 (K5.6) TECHNICAL DATA

MICROFAST QUICK RESPONSE PENDENT SPRINKLER VK3311 (K4.2) TECHNICAL DATA

freedom residential concealed pendent sprinkler vk474 (K5.8)

quick response horizontal sidewall sprinkler vk360 (K8.0)

standard response large orifice dry

micromatic standard response stainless steel sprinklers

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

Microfast quick response Fusible element hsw sprinkler

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

freedom residential concealed pendent Sprinkler vk458 (K7.4)

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

standard response fusible link sidewall sprinkler VK112 (K5.6)

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

quick response Sprinkler 105a October 25, 2010

micromatic standard sprinkler VK004 (K4.2) 3. technical data Page 1 of 6

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

standard/quick response extended coverage light and ordinary hazard elo sprinklers

freedom residential concealed pendent sprinkler VK488 (K3.0)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

standard response dry horizontal sidewall sprinklers

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

freedom residential concealed pendent lead free sprinkler

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

Transcription:

Page of 7 TECHNICAL DATA. DESCRIPTION Viking Mirage Standard and Quick Response Concealed Pendent VK6 and HP VK6 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a lowprofile cover assembly that provides up to ½ (.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The push-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive environments and is culus Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated.. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approval: Class 0 NYC Approved: MEA 89-9-E, Volume VdS Approved: Certificate G0800 LPCB Approved: Certificate number 096e/ CE Certified: Standard EN 9-, EC-certificate of conformity 0786-CPD-09 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 9-, EC-certificate 08-MED-00 Refer to Approval Chart Design Criteria for culus Listing requirements, and refer to Approval Chart and Design Criteria on page for FM Approval requirements that must be followed.. TECHNICAL DATA Specifications: Available since 006. Minimum Operating Pressure: 7 psi (0. bar)* Working Pressure: VK6 is rated for use with water working pressures ranging from the minimum 7 psi (0. bar) up to 0 psi (7. bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating 0 stamped on the deflector. VK6 is rated to a maximum 7 psi ( bar) wwp. Factory tested hydrostatically to 00 psi (. bar) Thread size: / ( mm) NPT Nominal K-Factor:.6 U.S. (80.6 metric ) Glass-bulb fluid temperature rated to -6 F (- C) Patents Pending *culus Listing, FM Approval, and NFPA installs require a minimum of 7 psi (0. bar). The minimum operating pressure for LPCB and CE Approvals ONLY is psi (0. bar). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. Material Standards: Body: Brass UNS-C800 Deflector: Copper UNS-C900 for VK6 Phosphor Bronze UNS-C000 for VK6 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal mm diameter Replaces Form No. F_000 Rev 8. (Updated MED approval.)

TECHNICAL DATA Page of 7 Pip Cap and Insert Assembly: Copper UNS-C000 and Stainless Steel UNS-S000 Button: Brass UNS-C6000 Screws: 8-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C000 Cover Adapter: Cold Rolled Steel UNS-G0080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover: Copper UNS-C000 or Stainless Steel UNS-S000 Base: Brass UNS-C6000 or UNS-C6800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage Standard and Quick Response Concealed Pendent s and Cover Plate Assemblies must be ordered separately: : Base Part No. VK6-0A for Brass finish and 0JN for ENT finish. VK6 - HP Base Part No. 667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix: F (68 C) = B, 7 F (79 C) = D, 00 F (9 C) = E For example, sprinkler VK6 with a F (68 C) temperature rating = 667AB. Standard Cover Plate Assembly: Base Part No. 0 (-/ diameter), Base Part No. 6 (-/6 diameter), or Base Part No. 9 (square cover plate, -/6 ) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: F (7 C) UL (9 F (9 C) FM and LPCB) = A, 6 F (7 C) = C For example, cover 0 with a Polished Chrome finish and a 6 F (7 C) temperature rating = 0FC. Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 876 (-/ diameter) or Base Part No. 87 (-/6 diameter). Temperature Suffix: F (7 C) UL (9 F (9 C) FM and LPCB) = A, 6 F (7 C) = C For example, cover 876 with a 6 F (7 C) temperature rating = 876C NOTE: The culus Listings for the square cover plate 9 are for the F (7 C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table. Accessories: (Also refer to the Viking website.) Wrenches**: A. Heavy Duty Wrench Part No. 07W/B (available since 006), or B. Head Cabinet Wrench Part No. 0*** (available since 006) C. Optional Concealed Cover Plate Installer Tool Part No. for cover 0, or Part No. 867 for the large diameter cover (available since 007) **Requires a ½ ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Cabinet: Part No. 07A (available since 97). INSTALLATION Refer to appropriate NFPA Installation Standards.. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking s VK6 and VK6 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly.

Page of 7 Temperature Classification Nominal Temperature Rating TABLE : AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Ambient Ceiling Temperature Ordinary F (68 C) 00 F (8 C) Temperature Rating of Cover Assembly (Required) F (7 C) culus 9 F (9 C) FM and LPCB Cover Plate Base Part Number Large Cover Plate Base Part Number Square Cover Plate Base Part Number Bulb Color 0 or 876 6 or 87 9 Red Intermediate 7 F (79 C) 0 F (6 C) 6 F (7 C) 0 or 876 6 or 87 9 Yellow Intermediate 00 F (9 C) 0 F (6 C) 6 F (7 C) 0 or 876 6 or 87 9 Green Cover Plate Finishes : Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Finishes: Brass and ENT Corrosion Resistant Coatings : ENT Footnotes The sprinkler temperature rating is stamped on the sprinkler deflector. Based on NFPA-. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway, but the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. FACTORY APPLIED CUSTOM PAINT COLOR All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure : Identification of Custom Paint for Concealed Covers -/6 (8 mm) Figure : Square Cover Assembly 9

Page of 7 Base Part No. SIN Approval Chart (UL) Mirage Concealed Pendent s VK6 and VK6 Thread Size Nominal K-Factor Water Working Listings and Approvals (Refer also to Design Criteria) Inch mm U.S. metric Pressure culus NYC VdS 7 LPCB Standard Response Applications 0A VK6 / --.6 80.6 7 psi ( bar) -- -- AY, CZ AY, BZ AY, CZ 8 AY -- 978A VK6 / --.6 80.6 7 psi ( bar) -- -- -- -- -- -- AY, CZ 6A VK6 --.6 80.6 7 psi ( bar) -- -- -- -- -- -- AY, CZ Quick Response Applications 0A VK6 /.6 80.6 7 psi ( bar) AV, BX, AS, BT AV, BX 6 -- -- -- AY -- 0JN VK6 /.6 80.6 7 psi ( bar) AV, BX, AS, BT AV, BX 6 -- -- -- -- -- 667A VK6 /.6 80.6 0 psi (7. bar) AV, BX AV, BX 6 -- -- -- -- -- Temperature Ratings A - F (68 C) B - 7 F (79 C) and 00 F (9 C) C - 00 F (9 C) Cover Plate Assembly Temperature Ratings, 9 S - F (7 C) cover 876 or 87 (large diameter) T - 6 F (7 C) cover 876 or 87 (large diameter) V - F (7 C) culus Listed cover 0, 6 (large diameter), or 9 (square cover plate) X - 6 F (7 C) cover 0, or 6 (large diameter) Y - F (7 C) cover 0 LPCB Approved as 9 F (9 C) Z - 6 F (7 C) cover 0 Cover Plate Assembly Finishes 0 - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black - Brass - Stainless Steel Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-9-E, Vol.. 7 VdS Approved, standards VdS :00-, VdS 00-:008-0, and EN 9-:999 + A:00 + A:00 + A:006, Certificate G0800. 8 CE Certified, Standard EN 9-, EC-certificate of conformity 0786-CPD-09. 9 The /9 F cover has an orange label. The 6 F (7 C) cover has a white label. 0 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. culus Listed as corrosion resistant. MED Certified, Standard 9-, EC-certificate 08-MED-00. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure.

DESIGN CRITERIA - UL (Also refer to Approval Chart ) Page of 7 culus Listing Requirements: Mirage Concealed Pendent s VK6 and VK6 are culus Listed as quick response for installation in accordance with the latest edition of NFPA for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA. spacing allowed is ft. (.6 m). Minimum spacing allowed is 6 ft. (.8 m) unless baffles are installed in accordance with NFPA. Minimum distance from walls is in. (0 mm). distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA for standard coverage pendent spray sprinklers must be followed. NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. VdS Approval Requirements: a) The sprinkler can be installed in a concrete ceiling (massive ceiling) or in a false ceiling made of light materials. b) This sprinkler is deflector fixed type and can be only activated by heat. The housing is not tight. c) Follow installation guidelines of current standards, CEA00VdS and EN8. These sprinklers can only be installed in LH and OH occupancies, except in OH. NOTES: Due to the design the sprinkler type Domed-CCP shall not be installed in false ceilings in which the false ceiling space is protected by a water extinguishing system. Due to the design the sprinkler type Domed-CCP shall not be installed in false ceilings in which during a fire the pressure above the false ceiling may be assumed to be higher than the pressure below the false ceiling. The criterion for the dropping of the cover relevant for this approval is heat. Steps of installation:. Prepare the sprinkler key.. Remove the plastic cover.. Hold the sprinkler with the wrench and fasten it.. Replace the plastic cover and do not remove until the cover is installed. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of s. Also refer to Form No. F_0806 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 6 of 7 Approval Chart (FM) Mirage Standard Response Concealed Pendent VK6 Base Part No. SIN NPT Thread Size Nominal K-Factor Inch mm U.S. metric Water Working Pressure FM Approvals (Refer also to Design Criteria below.) 0A VK6 /.6 80.6 7 psi ( bar) AW, BX, AY, BZ Temperature Ratings A - F (68 C) B - 7 F (79 C) and 00 F (9 C) Cover Plate Assembly Temperature Ratings, Y - 9 F (9 C) cover 87 or 876 Z - 6 F (7 C) cover 87 or 876 W - 9 F (9 C) cover 0, 6 (large diameter), or 9 (square cover plate) X - 6 F (7 C) cover 0, 6 (large diameter), or 9 (square cover plate) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. Cover Plate Assembly Finishes - Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black - Stainless Steel Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 0.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. The 9 F (9 C) cover has an orange label. The 6 F (7 C) cover has a white label. Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure. N FM Approval Requirements: DESIGN CRITERIA - FM (Also refer to Approval Chart above.) Viking Concealed Pendent VK6 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet -0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from culus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_09699 - Care and Handling of s. Also refer to Form No. F_0806 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.

Page 7 of 7 and Adapter Assembly Protective cap removed Use wrench 07WB** Wrench Part No. 07WB** -/ (7 mm) diameter opening required in the ceiling. Step : Carefully slide the wrench sideways around the deflector and pins Step : Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 07WB** or 0**. A leak tight seal should be achieved by turning the sprinkler clockwise to -/ turns beyond finger tight. wrench flat frame arms Figure : Installation and Proper Wrench Usage A / ratchet is required (Not available from Viking) ** / ( mm) NPT -9/6 (6 mm) -/6 ( mm) Minimum -/6 ( mm) NOTE: Upon sprinkler activation, the deflector descends to approximately /6 ( mm) below the sprinkler body. -/ (70 mm) or -/6 (8 mm) Figure : Dimensions and Cover Installation Replaces Form No. F_000 Rev 8. (Updated MED approval.)