Complete Boiler Management in a Compact, Affordable System

Similar documents
Complete burner management in a compact, affordable system

Complete burner management in a compact, affordable system

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

Power Flame Incorporated

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

HAWK INTEGRATED BOILER CONTROL SYSTEM

Mk7 Manual: M.M. Flame Safeguard and Operation

STEAMPAK Series BurnerPAK BMS Burner Management Systems

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Distributed By: M&M Control Service, Inc Building Technologies

Revitalize Building Mechanical Systems (4619)

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Control Products & Systems OEM

RS /E-EV C01 SERIES

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Cleaver-Brooks Webinars

LOW NOx MODULATING GAS BURNERS

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

RS /E-EV C01 SERIES

Triton Series High Efficiency Boiler

HCLEARFIRE. High-efficiency, modular steam boiler HP

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Honeywell SLATE ICM Platform

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

HIGH EFFICIENCY COMMERCIAL BOILERS

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Power Flame Incorporated

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

Section 1 Overview. Introduction 1-1

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Metasys Integrator Cleaver-Brooks Application

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Reliably Advanced Extinguishing Control

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

Sola Hydronic Control. An Eco-Friendly Solution.

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

New Versa IC Platform

DIVISION FINNED WATER-TUBE BOILERS

FUNCTIONAL DESIGN SPECIFICATION

Pulse Firing Doubles Capacity and Cuts Fuel Costs

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Medical Refrigerators

The integral solution for. Air Handling Units. Technology & Evolution

Control Products & Systems OEM

RIELLO 40 GS/M SERIES

SECTION INSTRUMENTATION AND CONTROL FOR BOILER PLANT

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Better Design, Better Control, Better Systems.

Hydronic & HVAC Control Systems

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

TopGas Wall Hung Condensing Gas Boiler

NOZ2. Multi-Directional Heating & Cooling Solutions

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

PROFIRE BMS Controller

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

LFL Series Burner Flame Safeguard Control

Hubbell NX500 High Efficiency Gas Condensing Water Heater

High Efficiency Burner Controls Beyond Efficiency June 7, 2016

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

5.0 ALARMS & TROUBLESHOOTING

White Paper. Integrated Safety for a Single BMS Evaluation Based on Siemens Simatic PCS7 System

SLATE. Integrated Combustion Equipment Management Success Stories

Ventilation in balance

Steam Fundamentals. (in heating & processing applications)

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

Reliably Advanced Extinguishing Control

SIMPLICITY BY DESIGN M52 CONTROLLER

GAS FIRED HUMIDIFIER. Advantages. Typical Applications. Typical Installation

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Project Name: Location: Engineer: Contractor: I. GENERAL

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

AC WhisperGen System Product Specification 11 June 2003

OPTIMUM APPLIED SYSTEMS,

Transcription:

Touchscreen Mini Mk8 Controller Complete Boiler Management in a Compact, Affordable System The Mini Mk8 is a cutting-edge Micro-Modulating system that provides an easily programmable and flexible means of optimising combustion throughout the load requirement range of the boiler/burner. This control module encompasses all the functions required for reliable burner management. Built into this system is a fully automated flame safeguard and valve proving system, MODBUS connectivity, and a new touchscreen interface. This system ensures the burner temperature is accurate to within 1 and pressure to within 1 PSI. The positioning accuracy of the direct drive motors controlling the air damper and fuel valve is 0.1 angular degrees throughout the load range. This accuracy ensures repeatable fuel-to-air ratio that leads to improved fuel economy and reduced carbon footprint. Able to reduce fuel consumption by 5-7% over traditional linkage systems Capable of reducing CO 2 emissions by 10% Repeatable and accurate positioning system reduces maintenance costs Controls fuel, VSD, scheduling, sequencing and other automatic settings Robust steel construction Available in a control panel package

Main Screen Actual facia size (16.75 x 13.5cm) Actual screen size (14 x 10.7cm) Optional functions like EGA, IBS, etc will appear/ disappear from screen when enabled/disabled. Touchscreen This system is configured for dual fuel. The user can get back to this Main Screen from anywhere in the system with a few taps. Navigate to advanced screens and history with the touch of a finger from the Main Screen. Steam Pressure or Water Temperature Setpoints Flame Safeguard Intelligent Boiler Sequencing Exhaust Gas Analyser (Requires installation of EGA) VSD (Variable Speed Drive) Air/Fuel Servomotors VPS (Valve Proving System) Online Settings & Fault History home/features

Schedule the boiler plant to run when and how you Drag slider to adjust timer. Tap to adjust function. need it. Schedule on, off and reduced (weekend) required temperature/pressure by day of week. It is much more fuel efficient to run two boilers at 60% than three boilers at 20%. Intelligent Boiler Sequencing (IBS) manages the number of boilers firing at any given time, automatically taking unneeded boilers offline or into standby warming modes to maintain load demand. Users can manage up to 10 boilers. Scheduling

Easily change target set points for both the Required setpoints (used for general ouput) and the Reduced setpoints (used for when less steam or hot water is required). The flame is monitored via UV or IR scanner or ionization probe. The UV scanner can feature self-checking to cover an unmanned boiler house. Post Purge Pre Purge Damper Main Valve Pilot Ignition Burner Motor Flame Safeguard monitors & manages every stage of burner startup, including valve proving & IR/UV testing. Dotted vertical line slides right as the system advances through burner sequence. 3 servomotors and 1 VSD provide accurate and repeatable control of valves and dampers. 24 hour on-screen history enables immediate troubleshooting and optimising. VPS (Valve Proving System) tests the main gas valves to ensure seal integrity and safety. status/history

Over 150 options and parameters can be adjusted providing a sophisticated level of customisation. All of these are viewable while the boiler is online. A selection of these changes can be set while the burner is running, ensuring minimum boiler downtime. A technician can view & modify a variety of settings without having to take the boiler offline, reducing boiler downtime. Error and Lockout logs allow engineers to view a history of burner operation to aid in troubleshooting. View the most recent 64 errors and lockouts. Single Point Change allows a technician to edit the combustion curve without the need of a full re-commission, reducing downtime. The optional Exhaust Gas Analyser (EGA) enables three parameter trim features to maintain commissioned exhaust values. This ensures optimum burner operation at all times. servicing

Main Features Direct replacement for Mini Mk7 Micro Modulation of fuel/air ratio control 2 fuel curve capability 3 servomotor channel control 1 VSD channel control Internal flame safeguard control Full flame supervision with self-check UV, IR or ionisation flame detection Self-check UV detection (optional) Lead-Lag/Intelligent Boiler Sequencing (IBS) Precise target setpoint control (PID) 3 parameter trim, O 2, & CO (requires EGA option) NFPA compliant Outdoor Temperature Compensation (requires OTC module) Time clock feature Improvements over Mini Mk7 Touchscreen interface XVGA 1024X768 Software update through Micro SD card Dual-core safety processor. Both processors run the same code in parallel, and if there are discrepancies the system fails safe Direct power to the IR scanner removes need for external power supply Logging of 64 most recent lockouts and 64 most recent errors Add additional inter points during single point change Scheduling enables up to 5 different states per day (Reduced/Off/On) Grouping of options/parameters in relation to function Gas pressure sensor monitoring Gas valve proving system Air pressure sensor proving system Low Flame Hold integrated into interface, removing need for panel switch operation Micro Modulation Fuel/Air Ratio Control Independently controlled fuel and air positioning motors with an accuracy of 0.1 of an angular degree Single point change facility for commissioned fuel/air ratio User-defined optimum ignition position FGR management delay from startup of FGR until exhaust temperature, boiler setpoint, or time delay achieved Burner Functions Burner control functions with user configurable timings User Features Editing of parameters protected by userconfigurable password IR COM s port for upload/download of commissioned data and operating history Boiler screen configuration Data exportable via Modbus Internal calendar clock display Multiple languages On-screen 24 hour data logging specifications

Setpoint Control Features Internal 3 term PID control to maintain required setpoint for both pressure and temperature Software-adjustable thermostat/pressure stat facility (lockable) Lead-lag for both steam and hot water Lead boiler select facility 2 port valve operation for hot water sequencing Fuel flow metering instantaneous and totalised Software-adjustable Hand/Auto/Low flame hold facility 0-10V input for external modulation Ability to use external temperature or pressure detectors External Inputs Low/high pressure switches Low/high end switches Specifications 120/230V, 50/60 Hz switchmode IP65/NEMA 4 enclosure with panel facia mounting (IP65 front facia, IP20 back of unit) Manufactured under BS EN ISO 9001:2000 EGA (optional module) O 2, CO trim, NO, SO 2, and NO 2 continuous monitoring and display User definable combustion limits on O 2, CO, NO, and exhaust gas temperature Exhaust temperature, ambient temperature and difference in temperature displayed Combustion efficiency calculation - net or gross displayed Patented three paramater trim Mini Mk8 Advantages: Fuel Savings Emission Control Repeatability/Durability Maintenance Savings Safety

About Autoflame Founded in 1972, Autoflame is a world leader in boiler/burner management systems for both commercial and industrial applications. Based near London, England, it ensures industry-leading quality control and innovation by performing inhouse R&D, engineering, software development, manufacturing production, and technical support. Privately held by its founder, Brendan Kemp, Autoflame currently has more than 10,000 systems in operation globally, and is now specified as standard equipment in some of the world s most prestigious organisations. Autoflame has partnerships with more than 60 technology centres worldwide. In each market we serve, our technology centres have been thoroughly vetted for quality and reliability. They receive regular training to ensure they are up to date with our latest innovations. Optional Upgrades The Autoflame Exhaust Gas Analyser (EGA) evaluates exhaust samples for temperature, O 2, CO, NO, NO 2, SO 2 and combustion efficiency. It then provides the O 2 and CO data feedback to the Mini Mk8. The Mini Mk8 then implements minute trim corrections to limit or increase air to the burner automatically to make it more fuel rich or air rich. These automatic corrections optimise combustion at all times, reducing fuel consumption and emissions without user intervention. The degree to which the Mini Mk8 implements these corrections is user-definable. The EGA can also signal an alarm or lockout if temperature or emissions exceed prescribed ranges. The EGA records emission data for up to 2 years. The Data Transfer Interface (DTI) collects data from up to ten Mini Mk8 systems in one site. Data can be transmitted to PC s and Building Management Systems via Ethernet (LAN) or Modbus (RS422). Autoflame s CEMS AUDIT Software brings burner control to the PC, either on-site or LAN/ internet, allowing for on/off control, temperature/pressure adjustment, and emmissions monitoring. Alarm conditions can be set, and if triggered a user can by notified by their BMS system. The software requires a DTI. Touchscreen Ancillary Equipment Autoflame manufactures to the highest quality standards a range of servomotors, probes, scanners, sensors, valves and other parts to support its burner/boiler management system. Phone: +44 (0) 845 872 2000 Fax: +44 (0) 845 872 2010 salesinfo@autoflame.com MINI8-14-10-2014 Autoflame Engineering Ltd. Autoflame.com