Product Data. Split System Cooling H-EN. January 2017

Similar documents
Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Cooling A. November 2013

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data. Split System Heat Pump

Product Data Split System Cooling

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Split System Heat Pump Product Data

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product & Performance Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Cooling Product Data

Split System Cooling Product & Performance Data

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Appendix J Noise Appendix

Illusion Split System

Hyperion TM Split Systems

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Split System Cooling Product Data XB 1000

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

Product Catalog Split System Air Conditioners Odyssey

Commercial High-Efficiency Condensing Units

Split System Heat Pump Product Data

MACH N-407 Heat Pump Air-Cooled Chiller

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Commercial High-Efficiency Condensing Units

R4H4. Product Specifications

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

MAC N-407 Air-Cooled Chiller

R4H4. Product Specifications

2 shp 13 lc 1 36 t - 1 a

WCH5**4. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

N4H4. Product Specifications

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

N4A6. Product Specifications

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

PACKAGE AIR CONDITIONER

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

36,000-62,000 BTUH Nominal Capacity

4YCC3048A3096A /3/ /

Transcription:

Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000B 4TTR4025L1000B 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note: Graphics in this document are for representation only. Actual model may differ in appearance. January 2017 22-1904-1H-EN

Product Specifications Model No. (a) 4TTR4018L1000A 4TTR4024L1000B/ 4TTR4025L1000B 4TTR4030L1000A/ 4TTR4031L1000A 4TTR4036L1000A/ 4TTR4037L1000A POWER CONNS. V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 14 17 18 BR. CIR. PROT. RTG. MAX. (AMPS) 20 20 25 30 COMPRESSOR CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATAUFF - SCROLL RL AMPS LR AMPS 9 63 10.1 52 12.8 68 14.1 72 Outdoor Fan FL AMPS 0.60 0.90 0.77/.64 0.77/.64 Fan HP 1/15 1/8 1/8 1/8 Fan Dia (inches) 18.2 18.2 23.0 23.0 Coil SPINE FIN SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 4 LBS., 8 OZ 4 LBS., 11 OZ 5 LBS., 4 OZ 6 LBS., 1 OZ LINE SIZE IN. O.D. GAS (c) 3/4 3/4 3/4 3/4 LINE SIZE IN. O.D. LIQ. (c) 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10 F 10 F 10 F 10 F / ( 8 F on 037) Dimensions H x W X D Crated (IN.) 30.1 x 26.7 x 30 30.1 x 26.7 x 30 34 x 30.1 x 33 38 x 30.1 x 33 Weight Shipping (lbs.) 153 153 183 183 Weight Net (lbs.) 133 133 156 156 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset (d) TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7* Service Valve Panel Cover AAYSVPANL0022AA AAYSVPANL0022AA AAYSVPANL0032AA AAYSVPANL3343AA (a) (b) (c) (d) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 60, Standard lift 60 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. * = 15, 20, 25, 30, 40 and 50 foot lineset available. 2 22-1904-1H-EN

Product Specifications Model No. (a) 4TTR4042L1000A/ 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A POWER CONNS. V/PH/HZ (b) 280/230/1/60 280/230/1/60 280/230/1/60 MIN. BRCH. CIR. AMPACITY 22 24 31 BR. CIR. PROT. RTG. MAX. (AMPS) 35 40 50 COMPRESSOR CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL AMPS LR AMPS 16.7 109 18.5 124 23.7 152.5 Outdoor Fan FL AMPS 1.05 1.05 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27.5 27.5 27.5 Coil SPINE FIN SPINE FIN SPINE FIN Refrigerant R-410A 6 LBS., 7 OZ 6 LBS., 9 OZ 7 LBS., 10 OZ LINE SIZE IN. O.D. GAS (c) 7/8 7/8 7/8 LINE SIZE IN. O.D. LIQ. (c) 3/8 3/8 3/8 Charge Spec. Subcooling 12 F 10 F 10 F Dimensions H x W X D Crated (IN.) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7 Weight Shipping (lbs.) 216 212 246 Weight Net (lbs.) 184 189 211 Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 Refrigerant Lineset (d) TAYREFLN7* TAYREFLN3* TAYREFLN3* Service Valve Panel Cover (a) (b) (c) (d) AAYSVPANL0044AA Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 60, Standard lift 60 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. * = 15, 20, 25, 30, 40 and 50 foot lineset available. 22-1904-1H-EN 3

Product Specifications MODEL A-Weighted Sound Power Level [db(a)] 63 * 125 250 Full Octave Sound Power(dB) 4TTR4018L1 71 74 71 65 68 67 63 56 50 4TTR4024L1 4TTR4025L1 71 74 71 65 68 67 63 56 50 4TTR4030L1 4TTR4031L1 71 73 73 72 69 68 60 52 45 4TTR4036L1 4TTR4037L1 71 73 73 72 69 68 60 52 45 4TTR4042L1 4TTR4043L1 71 81 72 69 69 66 60 57 54 4TTR4048L1 71 81 72 69 69 66 60 57 54 4TTR4060L1 71 81 72 69 69 66 60 57 54 500 1000 Note: Rated in accordance with AHRI Standard 270 2008 *For Reference Only 2000 4000 8000 4 22-1904-1H-EN

Accessory Description and Usage Anti-Short Cycle Timer Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. Evaporation Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. Model Nomenclature AHRI Standard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. 2. High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. 3. Low Temperature Heating 17 F DB air entering indoor coil. 4. Rated indoor airflow for heating is the same as for cooling. AHRI Standard 270 Rating Conditions (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95 F outdoor air. 4 T W V 0 0 3 6 A 1 0 0 0 A A 22-1904-1H-EN 5

Schematic Diagrams Figure 1. 1.5 4.0 Ton Models 6 22-1904-1H-EN

Schematic Diagrams Figure 2. 5.0 Ton Models 22-1904-1H-EN 7

Outline Drawing Model Base A B C D E F G H J K 4TTR4018L 2 4TTR4024L 4TTR4025L 4TTR4030L 4TTR4031L 4TTR4036L 4TTR4037L 4TTR4042L 4TTR4043L 2 3 3 4 4TTR4048L 4 4TTR4060L 4 730 (28 3/4) 730 (28 3/4) 730 (28 3/4) 832 (32 3/4) 741 (29 1/8) 741 (29 1/8) 943 (37 1/8) 724 (28 1/2) 724 (28 1/2) 829 (32 5/8) 829 (32 5/8) 946 (37 1/4) 946 (37 1/4) 946 (37 1/4) 651 (25 5/8) 651 (25 5/8) 756 (29 3/4) 756 (29 3/4) 870 (34 1/4) 870 (34 1/4) 870 (34 1/4) 3/4 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8 7/8 3/8 127 (5) 127 (5) 127 (5) 127 (5) 143 (5 5/8) 143 (5 5/8) 152 (6) 57 (2 1/4) 57 (2 1/4) 76 (3) 76 (3) 83 (3 1 4) 83 (3 1 4) 98 (3 7/8) 194 (7 5/8) 194 (7 5/8) 197 (7 3/4) 197 (7 3/4) 206 (8 1/8) 206 (8 1/8) 219 (8 5/8) 38 (1 1/2) 38 (1 1/2) 60 (2 3/8) 60 (2 3/8) 70 (2 3/4) 70 (2 3/4) 86 (3 3/8) 457 (18) 457 (18) 508 (20) 508 (20) 508 (20) 508 (20) 508 (20) 8 22-1904-1H-EN

Mechanical Specification Options General The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test. The base is made of a CMBP-G30 weatherproof material to resist corrosion. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Thermostats Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control See Low Ambient Cooling. 22-1904-1H-EN 9

Notes 10 22-1904-1H-EN

Notes 22-1904-1H-EN 11

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 22-1904-1H-EN 27 Jan 2017 Supersedes 22-1904-1G-EN (March 2016) 2015 Ingersoll Rand all rights reserved