G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

Similar documents
CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Cooled Butterfly 980nm Pump Laser Module

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

NX7363JB-BC. Data Sheet R08DS0009EJ0200 Rev.2.00 LASER DIODE. Sep 19, 2010 DESCRIPTION FEATURES

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

CATALOGUE LASER POINTERS

Electro Optical Components, Inc Skylane Boulevard, Santa Rosa, CA Toll Free: 855-EOC

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

(PT-A1-AC ) Surface Mount Ambient Visible Light Sensor. Electronics Tech. Direct Electronics Industry Co., Ltd. Version: July 31, 2017

Class 1 laser beam sensor safe for your eyes

LASER SAFETY BARRIER

NX7535 Series DESCRIPTION NX7535AN-AA FEATURES NX7535BN-AA

NX8663JB-BC. Data Sheet DESCRIPTION FEATURES R08DS0063EJ0100 LASER DIODE. Rev.1.00

Class 1 laser beam sensor safe for your eyes

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Metal, ceramic, plastic package products

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Class 1 laser beam sensor safe for your eyes

SMD 2121 Black Frame MC-S2121BHA

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

LASER DIODE NX7637BF-AA

Preliminary specification

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Important Safety Notice

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

The J22 and J23 series are high performance InGaAs detectors operating over the spectral range

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

G4 Pulsed Fiber Laser

AS 500. Instructions for Use. Version 1.0. December

Model ID-441-C InGaAs Near Infrared Detector with Preamplifier and Thermoelectric Cooler Operating Instructions

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

T3/E3 Fiber Optic Line Drivers

Technical Data Sheet 5mm Infrared LED, T-1

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

Specification MBT801-S

100 Ft. LASER DISTANCE METER

4-Channel Contact Closure Fiber Link Card System

All pulses < 4Hz (>0.25sec) BLUE>400mW. As measured under IEC measurement conditions for classification.

818 Series Low-Power Detectors

COMPACT FLAME CONTROLLER CFC 1000

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

COMPACT FLAME CONTROLLER CFC 2000

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

North Dakota State University Laser Safety

Wavelengths: From UV to Visible and IR COBRA TM Max

3kW 6kW, QUBE Fiber Lasers

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Technical Data Sheet 1.5mm Side Face Infrared LED

A. Administrative. B. Labeling and Posting. C. Control Measures. Laser Safety Self-Audit Checklist. Building Room Principal Investigator Date

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Fiber Optics and Liquid Level Sensors Line Guide

PRODUCT SPECIFICATION

Stony Brook University Hospital Environmental Health & Safety Policy & Procedure Manual. EH&S 6-8 Original : 1/00 Revision Date: 3/16/15 Pages 6

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

COMPACTNESS 34.1 PERFORMANCE ANTICIPATION

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

Hazard Analysis, Mitigation, and Operating Procedures for (Laser name) Laser

OWNERS MANUAL OPERATION GUIDE

NLC C61 Air-Cooled Argon-ion Laser

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

DUQUESNE UNIVERSITY. Laser Safety Program

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

Customers must fill in and mail the warranty card in order to activate the warranty.

order code: EQLA08 user manual

NLC 210 Air-Cooled Argon-ion Laser

G4 Pulsed Fiber Laser

This slide presentation has been prepared for Temple University Health System and is intended only for use by it s faculty, staff and students.

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Prizmatix UV Torch. User Manual

LUXEON S. Philips Lumileds does not recommend staring directly into any LED lamp or luminaire. LUXEON S Photobiological Safety Report

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

w w w. p r o l i g h t. c o. u k USER MANUAL Order code: EQLA15

OFS IV Optical Fibre System

Operating Microscope Adapter. Operator Manual

POWER METER INSTRUCTION MANUAL

Order code: EQLA21 user manual

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY

Transcription:

G155PU001S TECHNICAL DATA Pigtailed 14-PIN DIL Laser Diode with TEC Features 1 mw 1550 nm MQW Laser Diode Module with cooler 14pin DIL package with single mode fiber output Applications Optical Communication Ideal laser source of long-distance optical fiber communication Specifications (25 C) Type FLMS-1550-112-001 Min. Typ. Max. Unit Optical Specification CW Output Power P F - 1 - mw Center Wavelength λ C 1510 1550 1590 nm Spectral Width Δλ - 2 5 nm Wavelength Temperature Coefficient - 0.35 - nm/ C Fiber Characteristics Fiber Core Size - 9 - µm N.A. - 0.11 - Fiber Length 0.9 1 1.1 m Connector FC/PC Electrical Specification Slope Efficiency E S 0.2 - - W/A Threshold Current I th - 10 20 ma Operation Current I O - 35 - ma Operation Voltage V f - - 1.5 V Monitor Current I m 0.1 1.3 - ma Photodiode Dark Current I D - 10 20 na Cooling Capacity ΔT 40 - - C Cooler Current I C - 0.5 1 A Cooler Voltage V C - 1.2 2.1 V Thermistor Resistance R tr 9 10 11 KΩ Thermistor Constant β 3500 3900 4300 K Package Style 14PINDIP Absolute Maximum Ratings Reverse Voltage V r 2 V Operating Temperature T O -10 +75 C Storage Temperature T stg -40 +85 C 02.04.2012 G155PU001S 1 of 5

Package Dimensions 1 Cooler (+) 5 Laser (P), Case Ground 7 Monitor (N) 8 Monitor (P) 9 LD (N) 10 Laser (P), Case Ground 11 Thermistor 12 Thermistor 14 Cooler (-) 02.04.2012 G155PU001S 2 of 5

Typical Performance Curves Notes 1. Laser beam is harmful especially for your eyes. Don't look at the laser beam directly. 2. Lifetime of the diode laser varied with the operating temperature inversely. We advise that the TEC cooler should be used to keep the temperature suitable. 3. For turning on the diode laser, please increase the current gradually to the specified operating value. For shutting down the diode laser, please decrease the current to zero gradually, and then turn off the power. 4. Please wear static proof bracelet when operating. 5. Please connect the pins of the diode laser correctly as the picture shown in the manual. 6. The operating current must less than the rated current. Otherwise the diode laser should be damaged. 7. The fiber facet should be keep clean before the diode laser is operating. 8. Please use the constant-current source to avoid the surge. 9. Diode laser should be short circuit when stop using. 10. Bend diameter of the fiber must be larger than 4cm temporarily and 8cm permanently. 02.04.2012 G155PU001S 3 of 5

Laser usage requirements in environment Laser safety operating instructions A ultra-clean environment should be provided for operating the LD. The operating temperature should be controlled at 10 C 45 C. Laser safety warning signs should be posted in the working place. The requirements on the power supply driving the LD Constant-current should be available for power supply. The power supply should have the ability to avoid current or voltage surge at any condition (during start-up, intermittence or open circuit). The surge would result in instant increase of optical power, which can cause COMD (catastrophic optical mirror damage). High power Laser Diodes could operate in forward voltage. The reverse current and voltage should not be higher than 25 µa and 3 V, respectively. Laser operating requirements Please check the laser safeguard before used the LD. More information about the laser safe is mentioned in laser safe section of this manual. The semiconductor Laser Diode is a sensitive electronic device. Do not ship or store near strong electrostatic, electromagnetic, magnetic or radioactive fields. Please observe precaution for handling electrostatic sensitive devices, such as wearing anti-static wrist straps, use antistatic packaging material and tools when operation. Shut off the power supplier before connecting the LD with the power supplier. To shut off the LD please decrease the current to zero gradually then shut off the power supply. The operating current of laser must not be higher than the given rate current. The excessive current would accelerate aging and shorten lifetime, even damage the LD. Keep the fiber pigtail clean. In non-working environment, you must use the protection case to avoid fiber pigtail from being polluted. If you need to clean the fiber pigtail, use ethanol or water-free alcohol cotton balls and wipe fiber pigtail gently. Fiber pigtail protection case Fiber pigtail LD must be taken out of the fiber protection case before it starts to work. When laser is working, please don t point it straight to the fiber as shown below the yellow part, in order to prevent the fiber protection case from being damaged by high-power laser generated heat. LD must be taken out of the fiber protection case before it starts to work. When laser is working, please don t point it straight to the fiber as shown below the yellow part, in order to prevent the fiber protection case from being damaged by high-power laser generated heat. 02.04.2012 G155PU001S 4 of 5

Bending diameter of the fiber cannot be allowed to be less than 4cm. When bending the fiber, please make sure the starting point is away larger than 4cm from the fiber root. When moving the laser, please don`t directly use fiber (yellow part). Not obeying these rules may cause fracture of the laser fiber from the root. Fiber root Bending diameter D: D 4cm Fiber protection case Make sure that the module and the fiber are in the same plane. Cooling system High-power semiconductor Laser Diodes are temperature-sensitive devices. High temperature will affect its performance. Its lifetime may also be shortened by working at high temperature. So the generated heat must be removed in time when the LD is working. Water cooling system or TEC system is recommended for keeping the LD working at appropriate temperature. Laser safety instructions High power laser diodes are high energy laser devices. It is harmful to human body and health. Any personnel working with or around open lasers must be aware of the following: Exposure to the laser beam may cause physical burns and can cause severe eye damage. Proper eye protection should be used at all times. All eye protection should be appropriate for the radiation wavelength generated by the laser in use. Exposure to the laser beam may cause ignition of volatile or combustible materials. Never look directly into the laser output port. Interlock all rooms in which open beams may be present and post appropriate warnings on or near the doors. Access to these rooms should be limited to properly trained technicians when lasers are in use. Use appropriate protective coverings over all beam paths whenever possible. Lasers and optical elements should be positioned to keep the beam and reflections below eye level. 02.04.2012 G155PU001S 5 of 5