The 2013 National Fire Alarm and Signaling Code

Similar documents
NFPA 72 Code Changes vs 2013

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Fire Alarm System Fundamentals

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

MNEC NFPA 72 WHITE PAPER

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION


SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Fire Alarm System Inspection and Testing Report

2018 NICET Code Transition Changes

Florida Building Code 2010

Second Revision No. 104-NFPA [ Section No ] Submitter Information Verification. Committee Statement

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

INSPECTION AND TESTING FORM

Fire Alarm and Life Safety System Inspection Certificate

Changes in NFPA

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

Fire Alarm, Water Flow Alarm & Signaling Systems

El Reno Fire Department Fire Alarm Plan Review Worksheet

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Unified Fire Authority - Fire Prevention Bureau

1.3 REFERENCE STANDARDS

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

2019 COURSE CATALOG (rev )

Second Correlating Revision No. 21-NFPA [ Global Input ]

NFPA Changes

Fire Alarm Testing and Inspection Report

Fire Alarm Wiring. Circuit types, styles and limitations

Michigan State University Construction Standards FIRE DETECTION AND ALARM PAGE

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Overview of Fire Alarm Provisions Based on the 2012 IBC, IFC and NFPA 72, 2013 Edition

Advanced Fire Alarm Systems Training Program Outline (5 Day)

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement 10/20/ :03 AM

Proposed Changes to NFPA

AGENDA NFPA TECHNICAL COMMITTEE ON NOTIFICATION APPLIANCES. Report on Comments Meeting, October 13-14, Richmond Marriott, Richmond, VA

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

Bold items are particular to the City of Euless

Functional Performance Test

26 of 128 9/23/2014 9:25 AM

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

FIRE & LIFE SAFTEY STANDARD

SECTION COMMON WORK RESULTS FOR SAFETY AND SECURITY 1.1 RELATED SECTIONS

3.1 Introduction. 3.1 Introduction

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

SECTION FIRE ALARM SYSTEMS

You are required to READ ALL PAGES. of this application

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Full Service Central Station Fire Alarm Listing Evaluation

Brighton Area Fire Authority

Fire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability

THE BASICS OF FIRE ALARM PLAN REVIEW

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

SECTION FIRE ALARM INTEGRATED AUDIO VISUAL EMERGENCY COMMUNICATION SYSTEM

Questions/Comments for Richard Roux from Webinar on 7/11/13

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

VSC Fire & Security, Inc.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

STATE OF NORTH CAROLINA

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Frequently Asked Questions

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

SECTION : FIRE ALARM & DETECTION SYSTEMS

Applying Performance-based Fire Alarm System Design Part 4

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

University Design Standard Fire Alarm Systems

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio un=l the Webcast begins

Are You Prepared? The impending impact of Code on Servicing Security Systems

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

A. Provide addressable fire alarm system throughout the facility and supervise wet and preaction fire sprinkler system.

Transcription:

ARE YOU A MEMBER OF AFAA? WHY SHOULD YOU BE A MEMBER BECAUSE YOUR BUSINESS IS IMPORTANT James Mongeau The 2013 National Fire Alarm and Signaling Code 1

NFPA 72 Organization Be*er organiza2on Easier to locate key requirements Future growth NFPA 72 The National Fire Alarm and Signaling Code Administrative Chapters 1-9 Support Chapters 10-19 System Chapters 20-29 Usability Annexes A - I New Definitions (Narratives) Unwanted Alarm Malicious Alarm Nuisance Alarm Uninten2onal Alarm Unknown Alarm 2

Chapter 7 Documentation Applies to new system. Design Acceptance Completion Applies to existing system Alteration Maintenance Testing Chapter 7 Documentation Chapter 7 Documentation 7.1 Application 7.2 Min. Required Documentation 7.4 Shop Drawings (Inst. Documentation) 7.6 Insp., Testing & Maint. Documentation 7.8 Forms 7.3 Design (Layout) Documentation 7.5 Completion Documentation 7.7 Records 3

Chapter 7 Minimum Requirement Written Narrative Riser Diagram Floor plan Sequence of operation Equipment data sheets Manufacturers instructions Chapter 7 Battery calculations Voltage drop calculations for NAC s Completed Record of inspection and testing Completed record of completion A copy of Site Specific software Record (as-built) drawing 4

Chapter 7 Identification of the person responsible for design or layout USE of NFPA 170 symbols or others acceptable to the AHJ R/F Chapter 7 Documentation Beyond the Minimum Requirements Limi2ng clause added to 7.3, 7.4 and 7.5: The requirements of 7.3 shall apply only where required by other governing laws, codes or standards, other parts of this Code, or by project specifica@ons or drawings. 5

Chapter 7 Design Documentation Ambient noise & audible design sound pressure levels Designation of spaces to have visible notification Extensive ECS design documentation Chapter 10 Fundamentals Many changes to incorporate ECS Performance limitations to 10.3 equipment New 10.4 Installation and Design In areas that are not continuously occupied, automatic smoke detection shall be provided at the location of each fire alarm control unit(s) notification appliance circuit power extender(s) supervising station transmitting equipment To provide notification of fire at that location 6

Chapter 10 New 10.8 detection and signaling of conditions Conditions Abnormal, Alarm, Pre Alarm, Supervisory, trouble, Normal New 10.9 Response Conditions Abnormal, Alarm, Pre Alarm, Supervisory, trouble, Normal New 10.17 notification appliance circuits and control circuits Ground-fault, Short circuit fault (Shall not affect other notification circuits) Chapter 10 Changes by TMS to personnel requirements (10.5.3) Inspection personnel Testing personnel Service personnel Programming personnel (10.5.3.4) programming; personnel programming a system shall be certified by the system manufacturer ** Evidence of qualification shall be provided to AHJ 7

Chapter 10 10.6.5.2 Circuit Identification Circuit Disconnect permanently iden2fied at control unit. Permanently labeled for purpose Circuit discontent shall have red marking 15 Chapter 10 Fundamentals 10.6.7 Secondary Power Supply The secondary power supply for textual visible appliances shall be in accordance with 24.4.4.4.7.1. (10.6.7.2) Two hours 8

Chapter 10 Impairment reporting Supervising station must report fire alarm contract terminations to the AHJ (10.21.3) Service providers (but not owners??) must report any fire alarm system (not ECS?) out of service for more than 8 hours (10.21.4) Chapter 12 Circuits and Pathways Monitoring consolidated from CH 10 Circuit performance requirement consolidated from CH. 23 All power-limited and non power-limited circuits which enter or exit are now required to have transient protection (12.2.4.2) 9

Chapter 12 New 12.5 shared pathway designations Shared pathway level 0 Not required to segregate or prioritize life safety data from non life safety data Shared pathway level 1 Not required to segregate but shall prioritize life safety data from non life safety data Shared pathway level 2 Shall segregate life safety data from non life safety data Shared pathway level 3 Dedicated to the life safety system Chapter 14 Inspection, Testing and Maintenance New purpose section (14.2.1) Initial and re-acceptance inspections Initial and re-acceptance tests Periodic inspections Periodic tests 10

Chapter 14 Test plan (14.2.10) added Scope what will be tested Scope what will not be tested NFPA 72 includes and stops at the emergency control function interface device Documentation is a way to warn when an integrated test is not done Chapter 14 Mass Notification System Record Notification Appliance Record Record of Inspection and Testing Supplementary Record of Completion Forms Emergency Communications System Record Initiating Device Record Interface Component Record Records (14.6) unchanged Maintenance, Inspec2on, & Tes2ng Records (14.6.2) unchanged except reference to new Chapter 7 (7.8.2) for forms 11

Chapter 14 Inspection table (14.3.1) now has method Testing frequency and method tables combined into new table (14.4.3.2) Inspection and testing table numbers synchronized Chapter 17 Initiating Devices Remote alarm indicators must be labeled to indicate location and area protected (17.4.8) Nominal 30 ] spacing, 15 ] from walls or par22ons OR Coverage radius (0.7 x S) [17.7.3.2.3.1 (2)] ½ S ½ S ½ S ½ S R = 0.7 x S D = 1.4 x S 3'-0" 12

Chapter 17 Initiating Devices 17.7.4 Heating, Ventilating, and Air-Conditioning Detectors in air ducts or plenums are permi*ed to be supervisory or alarm ini2a2ng devices. (17.7.4.4) Was already permi*ed to be either in 21.7.4 of 2010 However 21.7.4 was changed in 2013 Requires supervisory but permits alarm if there is no signal to a constantly a*ended loca2on or supervising sta2on Requires supervisory but permits alarm if required by other governing laws, codes, or standards. Chapter 17 Initiating Devices 17.14 Manually Actuated Alarm-Initiating Devices Manually actuated alarm- ini2a2ng devices for ini2a2ng signals other than for fire alarm shall be permi*ed (17.14.1) Not red Must be labeled 13

Chapter 17 Initiating Devices 17.14 Manually Actuated Alarm-Initiating Devices Listed protec2ve covers are permi*ed on single- or double- ac2on manually actuated alarm ini2a2ng devices (17.14.7) Chapter 18 Notification Appliances Designer must identify where audible signaling will be provided (18.4.1.4.1) Designer must identify where visible signaling will be provided (18.5.2.1) Designer must document ambient SPL and design SPL Audible notification not required in non-occupiable areas(18.4.1.4.2)(18.5.1.2) 14

Chapter 18 Distinctive evacuation signal Now permitted for relocation Asserted that intelligibility is not required to be measured (18.4.10.4 & 5) Clarification that Low frequency signal is only required when it is needed to awaken sleeping occupants not all sleeping occupancies (18.4.5.3) Chapter 18 Notification Appliances 18.9 Textual and Graphical Visible Appliances Textual and Graphical Visible Appliances Does not apply to exit signs, etc. (18.9.1.2) Sta2c, flashing or scrolling (18.9.1.3) Desktop or surface (18.9.2.3) Locate for private mode (18.9.2.1) or public mode (18.9.2.2) 15

Ch. 21 Emergency Control Function Interfaces Requirement to test systems outside the scope of NFPA 72 was removed: (2010 ed.) 21.2.12 The opera2on of all fire safety emergency control func2ons shall be verified by an opera2onal test at the 2me of system acceptance. Elevator control and shutdown clarifica2ons Ch. 23 Protected Premises Fire Alarm Systems Circuit Performance 23.6.1* A single fault on a pathway connected to the addressable devices shall not cause the loss of more than 50 addressable devices. M 2 M 2 2 2 Four Class B SLCs M FACU 16

Ch. 23 Protected Premises Fire Alarm Systems Smoke alarms connected to a PPFAS supervisory only (23.8.3.2) CO detectors or detec2on systems connected to a PPFAS shall: (23.8.4.8) Ini2ate a CO alarm signal (Temporal 4) And shall indicate as Carbon Monoxide Alarm Excep2on: May indicate as supervisory if in accordance with emergency plans. Label as CO Response in accordance with emergency plans Chapter 24 Emergency Communication Systems Mass notification layers (24.3.8) Layer 1 in building Layer 2 outside wide area Layer 3 Distributed recipient MNS Layer 4 Public measure- n Broadcast, radio, TV, etc 17

Chapter 24 Extensive documentation requirements Colored strobes are NOT required but permitted Emergency Command Center defined and explained in annex(24.6.1) Chapter 26 Supervising Station Alarm Systems Alarm Signal Pre- verification(26.2.2) Point ID permitted, but not required (26.2.4) Supervising station must report fire alarm contract terminations to the AHJ (26.2.7.5) 18

Chapter 26 Single communications path option Requires<60 min test intervals Multiple communication path option Requires < 6 hours test intervals Chapter 26 Digital Alarm Communicator Transmitter(DACT) (26.6.3.2) Elimination of phone line for 2 nd transmission means Three options n One way private radio n Two way RF system n Performance based Testing interval reduced from 24 hours to 6 hours (for each transmission means) 19

Thank you for your time Time is not something you can borrow so I truly hope I did not waste yours. 20