HEATING INVERTER DHC 6510R WELD PREHEATING AND STRESS RELIEVING

Similar documents
User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Oakton TEMP 9500 Advanced Multiparameter Controller

Compact Ultra Low Temperature Chamber

User Manual. Rooster series. This Manual applies to: Drying ovens and sterilizers. Rooster Series. Models : Rooster 30, 55, 80, 110, 140, 210 and 230.

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

JOVY SYSTEMS RE User Manual Rev. 1.00

Infrared heater - Item Description. Print

Bench-Top Vacuum Oven with 28 segments programmable controller

ec Preheater User Manual

Heated tools. Semiconductor equipment

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Altanium Temperature Controllers

FAG Induction Heating Devices HEATER. Quality and Safety Redefined

Standard Heat Treating Equipment Product Catalogue

Temperature Data Logging

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Combined boiler. for solid fuel and pellets

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

STR-600 Impact Dryer

HV-50 HVOF Thermal Spray System

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL


Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Software Version 2.01 LEVEL MONITOR MODEL 220

SCAN200E USER S MANUAL

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

Ventilation in balance

The Leaders in Heat Transfer. CRES MF Compact In-Line Electric Heater

S ATION EWORK ST BGA R

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Tel.: 016/ Fax: 016/

Quickheat 30 weather compensated boiler control

TEMPERATURE CONTROL MODULE MODEL R3-TC2

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

SPECIFICATIONS - NIKE

OUMAN EH-800 Heating controller USER MANUAL

KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Conveyor and Batch Reflow Ovens

DEKO Washer-disinfector WASHROOM SYSTEMS

IH 025 VOLCANO. Portable Induction Heater. smart mounting

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Process & TeMPerATUre UniversAl input DigiTAl MeTers

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Get connected with Xantrex Grid-Tie Inverters

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

GMM Güntner Motor Management

Customized Industrial Products

RND Soldering Station. RND W Temperature Controlled Soldering Station Instruction Manual

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Instrumentation Products and Applications

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

SHENZHEN ZHUOMAO TECHNOLOGY CO., LTD. BGA Rework Station ZM-R5860C Instruction Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

onlinecomponents.com

NEW GENERATION. Efficient use of valuable space INCUBATORS

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Repair under control

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

S ATION EWORK ST BGA R

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Universal control panel incorporating SIMS TM technology HTG Installation and Maintenance Instructions

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Automatic Isokinetic Sampler ST5

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

Do you want a versatile solution

Foodservice Fabrication Specialists

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

HEDSON TECHNOLOGIES WHEN YOU ARE GOING TO EQUIP, EQUIP TO WIN.

NEXT GENERATION OF ELECTRICAL LADLE HEATERS: A CASE STORY. Marcus Andersson. Sandvik Heating Technology, Hallstahammar, Sweden ABSTRACT

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Gas 220 Ace Cascade Assembly Manual

Service: to SLK Laboratory Hot Plates glass made of ideas

STREBEL S-CB + Cascade Kits

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

EasyLog Data Logger Series

The New Cooling Unit Generation Blue e+

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

JOVY SYSTEMS RE-7500 User Manual Rev Index

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Transcription:

HEATING INVERTER DHC 0R WELD PREHEATING AND STRESS RELIEVING APPLICATIONS ADVANTAGES Mobility - weighs only 7 kg, small size similar to a small welding machine. High performance - 0. kw connection to up to elements with a total length of up to. m. in - complex consisting of inverter + thermocontrol + recorder*. Quick and easy installation of the whole system - connecting elements, thermocouples and source set up in a matter of minutes - ready to heat up quickly! Built-in controller enables manual mode or programming. Low operating cost and low cost of consumables. No gas cost and minimal cost insulation. Insulation can be used repeatedly: 0-0x. Elements withstand repeated use under standard treatment. Low power consumption. Energy efficient system of preheating and heat treatment. Even and stable heating to the desired temperature with minimal deviation. Surface of the heated part is not locally overheated above the desired temperature as with a flame source. Surface of the material is not carburized as when using flame heating. Better safety and working conditions for welders. Operators and welders are not exposed to open flame, hot gases and the risk of explosion as when using flame. No health risks for operators from high frequency or high output voltage. Parts can be heated up to 800 C or higher without using water cooling and therefore offer greater flexibility of use. Any material can be preheated. Enables easy preheating of any material and non-ferrous materials. Lower costs for staff training, lower wage costs. Staff only installs and programs the device. The source heats the material unattended. There is no need to hold the burner and permanently check achieved temperature as with the flame. Continuous control of heating power, power supply. Significantly increases life of elements, reduces energy consumption and reduces demands on power grid. Very reasonable purchase cost compared to inductive heating. *) for R only Parts that require preheating before welding in the automotive, rail and shipping industry. Pipe and flange manufacturing, construction and repairs. Petrochemical industry - manufacturing, construction and repairs. Preheating before hard surfacing, foundry. Heat exchangers, pressure vessels, flanges etc. Energy industry. Manufacture of steel structures. Mining equipment. Maintenance TECHNICAL DATA DHP 00/R DHC 0R Output voltage / current 0-0 V / 80 A, continuously adjustable, CV/CC 0-0 V / 80 A, V / 0 A continuously adjustable, CV/CC Load Resistance heater elements 2-0 V (type 0 / 2 / 0 V) Supply voltage / current ~00 V, 0/0 Hz, 2 A ±% Supply fuse Temperature sensor 2 A Thermocouple type K, with galvanized insulation Range / regulation -0 C to 0 C / -2 C to 200 C Alarm Fault detection Multizone control Flexibility of use - can be connected anywhere, power supply x 00 V 2 A, easy and quick installation. Intuitive and easy control - low attention demands during operation. Control is similar to welding machines. Versatile use of preheating - even heating for shaped, flat, circular positioned or standard components. Operating temp. / coverage Dimensions and weight Multizone heating and control. Parallel connection of multiple inverters (up to 9 sources) enable multiple heating power and precise control of heating in up to 9 zones from one control. 2 adjustable (deviation SV/PV, Hi-alarm temperature achieved etc.) Thermocouple disconnection, overload, overheating, output short circuit etc. Yes, master/slave type, No max. 9 units -20 C to 0 C (with a capacity limit to 0 C) 70x70x0 mm, 7 kg Tel 07 978 70, web: www.foxheat.com, e-mail: admin@foxheat.com sales@dawell.cz

TYPICAL USE INVERTER DHP 00/R is a complex system specifically designed for quick and easy controlled weld preheating of various materials from 0 C to 00 C. Heating output can be programmed or changed during the process. The operator sets the temperature to which the material needs to heat up and the controller itself will ensure the fastest heating to the desired temperature. Alternatively, you can set the heating rate in the program and the controller heats the material at the set speed. Inverter DHP 00R is also equipped with recording machine. The whole heating process is digitally recorded and can be displayed in a table and graph form. Data can be copied to a PC using USB cable. Magnetic elements for heating flat surfaces and pipes in various positions. TYPICAL USE OF PREHEATING DHP Power and petrochemical industry preheating pipe joints, heat exchangers, boilers, stators, steel vessels, flanges etc. Constructions production, shipbuilding preheating long, short and shaped welds. Mining industry preheating pipes before welding and hard surfacing. Industrial protection preheating parts to a desired temperature. Repairs, renovations and hard surfacing economically and technologically correct preheating of components. With the ability to use up to four elements, it is possible to preheat long welds. Saves time preheating and therefore costs. Maintains required temperature of the parts before, during and after welding. Higher quality of welding. Even heating of parts to exact temperature. Significantly reduces gas costs. Increases safety and productivity of welders. INVERTOR DHC 0R is designed primarily for weld preheating and stress relieving of materials after welding to reduce stress, reduce hydrogen content and for preheating before welding up to 00 C. Compared to inverters DHP, it also has the option of higher-level programming designed especially for weld preheating and stress relieving. It also enables multizone mode, linking and copying programs, setting more control values and others. Recording time is hours. TYPICAL USE OF HEAT TREATMENT INVERTER DHC Standard elements for weld preheating and stress relieving of straight and curved surfaces and pipes in various positions. Power and petrochemical industry heat treatment and preheating pipe joints, heat exchangers, boilers, stators, steel vessels, flanges wherever there is a need to anneal welds after welding. Constructions production, shipbuilding welding long and short circuits weld preheating and subsequent heat treatment. Mining industry weld preheating components before welding and hard surfacing. Industrial protection weld preheating parts to a desired temperature. Repairs, renovations and hard surfacing economically and technologically correct preheating of components. Due to high mobility, DHC inverters can be used for preheating and heat treatment also in the field. With the ability to use up to four elements, it is possible to preheat long welds. Maintains required temperature of the parts before and after welding. Even heating of parts to exact temperature. Significantly reduces gas costs. Possibility of timing the process start and therefore reducing time for preparation before welding. Increases safety and productivity of welders. Due to parallel connection, continuous power up to 9 kw can be achieved. A wide range of element sizes and types. For normal preheating or stress relieving, -2 elements are sufficient. Low demands on storing consumables. Tel 07 978 70, web www.foxheat.com, e-mail admin@foxheat.com 2

ADVANTAGES OVER OTHER METHODS Inverters DHP and DHC can be used to supplement or replace conventional flame heating. Or can complete induction, big resistance heating sources. Inverter sources DHP and DHC for resistance heating have the following advantages, which increase their attractiveness in production, maintenance, renovation workshops, foundries, outdoor plants, etc.: ADVANTAGES OF RESISTANCE HEATING DHP AND DHC OVER FLAME HEATING Controlled preheating with recording. It is possible to print out the preheating record from PC and to present it together with manufacturing documentation. Controlled preheating to exact temperature with minimal deviation. Programmed and automatic preheating will reach the required temperature without need for operator s intervention or assistance, which reduces labor costs. Surface of the heated component is not locally overheated more than to the required temperature as with the flame. Surface of the material is not exposed to open flame and is not carburized as when using flame heating. Significantly higher safety. Operators and welders are not exposed to open flame and its effects, hence the risk of injury, fire or explosion. Lower energy use. Thanks to insulation, temperature does not leak outside the heated area. No need of testing and certification of staff to work with flame. Savings on thermochalks, thermometers, etc. ADVANTAGES OF RESISTANCE HEATING DHP AND DHC OVER INDUCTION HEATING Multi-zone heating better temperature control of larger parts by using more thermocouples. Parallel arrangement of sources to achieve higher continuous power and more precise control of the desired temperature. It is possible to heat various types of materials without modifications such as ferrous metals etc. Heating of temperature up to 00 C. No need for water-cooling in the whole temperature range up 00 C. Significantly lower purchase cost of equipment and accessories. Easier and inexpensive staff training. Even heating of surfaces due to greater surface of elements. Safe output voltage. Possibility of using magnetic elements. Several types of elements for various applications. Higher mobility weighs only 7 kg. Can be transported even in a passenger car! Easy and quick installation of elements, thermocouples and insulation. COMPLETE SET OF INVERTER DHP AND ACCESSORIES 2 Description Amount Pos. DHP00-200R DHP 00R inverter machine with regulator and recorder 0. kw HEA0-000 HEA0-0000 Heating element 2.7 kw - 0 V - A 00x0 mm Tygasil insulation, 2 mm thick, 000x00 mm 2 HEA0-00 Splitting cable 0 mm 2, m long, -way 2 HEA0-0200 Compensating cable 2x. mm 2, m HEA0-020000 2x0. mm 2 thermocouple type K twisted wire, isolated 0 Tel 07 978 70, web www.foxheat.com, e-mail admin@foxheat.com

CONTROLLER AND RECORDER CONTROLLER DHP 00/R easy and intuitive operation. Easy adjustment of controller parameters and heating start. The controller allows setting in the following modes - heating power, heating to a temperature, or adjustment of the following parameters of ramp segment, i.e. heating rate C/h, target temperature, i.e. set point and holding time. The most commonly used program for preheating is PRG, i.e. heating to a temperature in the shortest time possible. CONTROLLER AND RECORDER DHC 0R easy programming of the controller. Fast download of data from recording machine and easy work with measured data. Temperature can be controlled from any of the 20 user-adjustable temperature profiles / programs with up to 80 segments or directly to a user-set temperature, which can be changed any time as needed. You can set heating or cooling rate, time over which the temperature should be maintained as well as target temperature, independently in each profile segment as well as in the manual mode of temperature control. Of course, heating power can be controlled directly. The controller has a user lock in menu for locking settings of PID values. Digital recorder of the course of heating with the capacity of hours of recording is also integrated. Data can be transferred to a PC where it can be further processed, for example for logging the course of heating or its control. Thereby, maximum complexity and simplicity of use of this device was achieved, its control can be handled by anyone. Both inverters DHP 00R and DHC 0R allow you to connect external recorder. TABLE WITH MEASURED DATA VALUES RECORDED IN RECORDING MACHINE SPTemp [ C] Setting value required temperature PVTemp [ C] Process Value real measured temperature MV [%] Manipulation Value output power Volt [V] Measured output voltage Curr [A] Measured output current Time [h:m:s] Measured time GRAPHICAL DISPLAY OF DATA SPTemp [ C] PVTemp [ C] TECHNICAL DATA OF CONTROLLER AND RECORDER DHP 00 / DHP 00R DHC 0R Temperature control according to the set temperature program 2 Control Control to the set temperature Control of (output) power 0 Temperature profiles 2 segments 20 adjustable profiles at 9 segments, max. 80 segments Segment parameters Ramp OFF /... 9999 C/h Setpoint -2 C... 200 C Hold time OFF... 9999 min. Controller Digital, user-adjustable Recorder 8 hours of recording* h of recording, stores PV/SP/MV and error status Data downloading *) for R only Using 8/USB to PC to a text file (direct import to Excel)* Tel 07 978 70, web www.foxheat.com e-mail admin@foxheat.com

CONNECTION AND CONTROL Easy and intuitive inverter DHP 00/R control. Well-arranged connection of cables on the front of the inverter. ON button to start and stop heating DHP 2 Temperature and MW displays SET PARAMETERS button to select parameters + and buttons to select values Thermocouple plug Plug for downloading data from integrated recording machine 2 7 + and quick-couples to connect elements 7 Fast and easy operator training within approx. hours. Operator can adjust the machine and work independently after hour training. ON button to start and stop heating DHC 2 PV, SV and MV displays Control buttons for programming and recording process SET PARAMETERS button to select parameters + and buttons to select values Thermocouple and external recorder plug 7 MASTER/SLAVE plug for connecting second inverter and for downloading data from internal recording machine 8 + and quick-couples to connect elements 2 7 MULTIZONE CONNECTION OF DHC INVERTERS 8 MULTIZONE THERMOCOUPLE MEASUREMENT FOR VARIOUS PIPE DIAMETERS. 2. 9. Linking up to 9 machines, 9 kw. PARALLEL CONNECTION OF COUPLES DIA 0 mm 0 mm DIA > 0 mm DIA > 0 mm Maximum number of couples pcs per one inverter. Arrangement of thermocouples in the case of multizone control. Tel 07 978 70, web www.foxheat.com, e-mail admin@foxheat.com

CODES, ACCESSORIES DHP00-200 DHP00-200R Heating inverters DHP 00 inverter machine with regulator 0. kw, phase 00 V 0/0 Hz DHP 00R inverter machine with regulator and recorder 0. kw, phase 00 V 0/0 Hz, CD with download software and USB connector included HEA0-0000 HEA0-00202 HEA0-00200 HEA0-00220 External recorders Monitoring recorder with channels, CF card Monitoring recorder with 2 channels, CF card FH 0- with channels FH 0-2 with 2 channels DHC0-200R HEA0-000 HEA0-000 HEA0-0070 HEA0-0080 HEA0-0090 HEA0-0000 HEA0-000 HEA0-0020 HEA0-000 HEA0-000 HEA0-000 HEA0-000 HEA0-0070 HEA0-0080 HEA0-0090 HEA0-0000 HEA0-000 HEA0-0020 HEA0-000 HEA0-000 HEA0-000 HEA0-002000 HEA0-0000 HEA0-0000 HEA0-0000 HEA0-ONREQT Heating inverters DHC 0R inverter machine with regulator and recorder 0. kw, phase 00 V 0/0 Hz, CD with download software and USB connector included Elementy 0 V Heating element 2.7 kw - 0 V - A 0x00 mm Heating element 2.7 kw - 0 V - A 0x07 mm Heating element 2.7 kw - 0 V - A 0x09 mm Heating element 2.7 kw - 0 V - A 0x mm Heating element 2.7 kw - 0 V - A 0x mm Heating element 2.7 kw - 0 V - A 0x mm Heating element 2.7 kw - 0 V - A 7x7 mm Heating element 2.7 kw - 0 V - A 7x7 mm Heating element 2.7 kw - 0 V - A 7x70 mm Heating element 2.7 kw - 0 V - A 00x2 mm Heating element 2.7 kw - 0 V - A 00x0 mm Heating element 2.7 kw - 0 V - A 00x mm Heating element 2.7 kw - 0 V - A 2x20 mm Heating element 2.7 kw - 0 V - A 2x0 mm Heating element 2.7 kw - 0 V - A 2x0 mm Heating element 2.7 kw - 0 V - A 0x mm Heating element 2.7 kw - 0 V - A 0x0 mm Heating element 2.7 kw - 0 V - A 0x80 mm Heating element 2.7 kw - 0 V - A 7x29 mm Heating element 2.7 kw - 0 V - A 7x mm Heating element 2.7 kw - 0 V - A 200x2 mm Heating tapes 0 V, max. length 200 mm Magnetic preheater 0 V, 00x80 mm Magnetic preheater 0 V, 000x80 mm One-line heating cable 0 V, length 00 mm Heating elements made to size Insulation HEA0-0000 Ceramic fibre insulat. 28 kg/m 2 - mm thick, 8.92 m 2 HEA0-00002 Ceramic fibre insulat. 28 kg/m 2-2 mm thick,. m 2 HEA0-00000 Ceramic fibre insulat. 28 kg/m 2-0 mm thick, 2.2 m 2 HEA0-0000 Tygasil insulation, 2 mm thick, 2000x00 mm HEA0-0000 Tygasil insulation, 2 mm thick, 200x00 mm HEA0-0000 Tygasil insulation, 2 mm thick, 000x00 mm HEA0-00020 Tygasil insulation, 2 mm thick, 00x00 mm HEA0-000202 Tygasil insulation, 2 mm thick, 000x00 mm HEA0-00020 Tygasil insulation, 2 mm thick, 00x00 mm HEA0-00020 Tygasil insulation, 2 mm thick, 2000x00 mm Elements 0 V HEA0-0000 Heating element. kw - 0 V - A 0x2 mm HEA0-00020 Heating element. kw - 0 V - A 0x mm HEA0-0000 Heating element. kw - 0 V - A 0x mm HEA0-0000 Heating element. kw - 0 V - A 7x0 mm HEA0-0000 Heating element. kw - 0 V - A 7x80 mm HEA0-0000 Heating element. kw - 0 V - A 00x2 mm HEA0-000 Heating element. kw - 0 V - A 0x9 mm HEA0-000 Heating element. kw - 0 V - A 7x2 mm HEA0-0070 Heating element. kw - 0 V - A 7x0 mm HEA0-0080 Heating element. kw - 0 V - A 7x7 mm HEA0-0090 Heating element. kw - 0 V - A 200x0 mm HEA0-00200 Heating element. kw - 0 V - A 200x2 mm HEA0-0020 Heating element. kw - 0 V - A 200x0 mm Cables and connectors HEA0-00 Splitting cable 0 mm 2, length 2 m, 2-way HEA0-002 Connecting cable - double 0 m HEA0-00 Splitting cable 0 mm 2, length m, -way HEA0-0200 Compensatig cable 2x. mm 2, m HEA0-0200 Compensatig cable 2x. mm 2, 0 m HEA0-02000 Thermocouple socket HEA0-020002 Thermocouple plug female HEA0-02000 Thermocouple plug male HEA0-00008 USB connection cable x with USB reducer HEA0-00009 USB connection cable multichanel x2 with USB reducer HEA0-000020 USB connection cable multichanel x with USB reducer Tightening straps HEA0-00000 Tightening straps x 0. mm 0-00 m HEA0-00000 Locks for tightening strap x 0. mm Thermocouple fine point attachment units HEA0-00000 Thermocouple fine point attachment unit FPU00, comp. HEA0-00000 Thermocouple fine point attachment unit FPU200, comp. Trolleys for inverters DHC-TROLL-U Trolley for DHC units DHC-TROLL-U Trolley for DHC units Rights for changes reserved. 20 DISTRIBUTOR HEA0-020000 HEA0-0200700 HEA0-020000 Thermocouples type "K" 2x0. mm 2 thermocouple type "K" twisted wire, isolated 2x0.7 mm 2 thermocouple type "K" twisted wire, isolated 2x.0 mm 2 thermocouple type "K" twisted wire, isolated Tel 07 978 70, web www.foxheat.com, e-mail admin@foxheat.com