Industrial Automation Enclosure

Similar documents
Part Number: RCSTR INSTRUCTIONS CM450 SAFETY REQUIREMENTS

OPTICOM Fiber Optic Splice Module

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

NHR-25 Feed Hopper with Agitator

HR Powder Feed Hopper

COOKTOP PARTS For Model: KDRS807XSP01 (Stainless)

Pole Mounting System Installation & Certification Manual

COOKTOP PARTS For Models: KESS907SBL04, KESS907SWW04, KESS907SSS04 (Black) (Designer White) (Stainless)

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

27" Gas Dryer MODELS: MGDB950YW3 (White) MGDB950YG3 (Cosmetallic) 05/31/ Maytag Part No. W Rev. A

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTRUCTION & SERVICE MANUAL

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

standards: standards:

Harvey Chemiclave EC Series Sterilizers

MBCE-110/230UV Flame Sensor Module

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Operating Instructions

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

Model 9001, Alarm

HDLV 55-Gallon Powder Drum Unloader

PUREFIRE PF-850 & PF PF-850 & PF-1000 Heat Exchanger

INSTRUCTION & SERVICE MANUAL

ES-5050 / ES5050TE Parts Manual

Service Manual Model 3163

WIDE AREA VACUUM MODEL PF2030 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

MBCE-110/230FR Flame Sensor Module

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Rotary XL (558 Series) and Classic (548 Series)

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Installation Instructions

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

WATLOW ELECTRIC MANUFACTURING COMPANY Installation & Maintenance Manual for ECO-HEAT Heaters I&M MANUAL No: Page: 1 Date: 3/15/2017 Rev: 4

INSTRUCTION MANUAL (ATEX / IECEx)

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

Orbis Battery Scrubber OBS38130

INSTALLATION AND USER INSTRUCTION MANUAL RENCOOL ECK4-48

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

Manifold Installation Controller MIC-180. Installation and Operation Instructions

AVANI Grinding Booth

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

MBCE-110/230FR Flame Sensor Module

Product Support Bulletin

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

HI Industrial Utility Heater HI Soleus Air International

COOKTOP, BURNER AND GRATE PARTS For Model: JDRP430WP00 (Stainless)

Model 9001, Alarm

IntelliDoX Operator Manual

e Heater/Exhaust Fan/Light User s Guide

CR Series Command Relays

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

24 VAC SYSTEM CONTROL KIT

TECHNICAL INSTRUCTIONS

GV Series 4 Section Assembly

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

A I FAN ASSEMBLY KIT FOR SERIES 3860 AND 3890 DESCRIPTION

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

GAS DRYER MODELS: MGD8200FW0 (White) MGD8200FC0 (Chrome Shadow) 05/24/ Maytag Part No. W Rev. A

VANGUARD 245 POST-MIX DISPENSER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Ductless Split Air Conditioner

SERIES: A REVISION ECN# DESCRIPTION OF CHANGE MOD. BY DATE 3 N/A DRAIN HOSE UPDATED 31/08/2016. Drawing Ref. No. Kit No. Part Description Qty

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

CAUTION . CRACKED. SCRATCHED. BOILED DRY. HEATED WHEN EMPTY. USED ON HIGH FLAME. OR EXPOSED ELECTRIC FAILURE TO COMPLY RISKS INJURY

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

Integrated Hood Liner

Installation Instructions

SEL-3422 Motor Relay HMI Quick-Start Guide

Everbrite LCD OrderRite Order Confirmation System

MLG35 Parts Manual Phase 8

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

1 x4 Dimmable LED RetroFits

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

Repair Parts List DRYER MODEL NUMBER MDG30PN3AW. When requesting service or ordering parts, always provide the following information:

Dual Column Dehydrating Breather Manual

e Bath Fan with Light User s Guide

INSTALLATION AND OPERATION GUIDE

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Manual. Model 200QF 8/8 Model 200QF 8/ DC Edge III

29" GAS DRYER MODELS: MGD7000AW1 (White) MGD7000AG1 (Cosmetallic) 07/02/ Maytag Part No. W Rev. A

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

BUNN CWT-CS CWTF-CS BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Transcription:

Industrial Automation Enclosure Part Number: IAEIP66, IAEFK54 Panduit Corp. 2004 INSTALLATION INSTRUCTIONS Important Notice: Should Fan Kit P/N IAEFK54 be integrated into the enclosure, P/N IAEIP66, the IP rating of the enclosure shall be reduced to IP54. If the enclosure and any active equipment is located in an environment containing conductive particles that have the potential to cause sparks and shorts, or the enclosure is placed in an environment that contains ignitable dust or explosive gases, in this scenario the IP rating of the enclosure shall be reduced to IP44. Before any application in these last cases, the installer should insure that all requirements, legal and industry, are met and precautions are taken to meet the installation requirements of the equipment placed inside the enclosure. List of Components: (1) 24 VDC Power Supply (3) TAK-TYS (6) Adhesive Backed Mounts (6) PAN-TYS (1) Electrical Hole Seal (1) Port ID Label (3) ing s (1) 12 AWG ing (1) 35mm DIN Rail (1) #10-32 x 1/2" Pan Head Screw (3) #10 Spring Lock Washer (2) #10-32 Hex Nut IAEIP66 35mm DIN Rail Inner Panel Opening for 1/2" Conduit Fitting Opening for Industrial Enclosure Gland Plate Cover Plates for Fan and Exhaust Filter Openings (view shown with door removed) Page 1 of 5

Step 1: Power Supply Installation 1.1 Install the 24 VDC Power Supply to the 35mm DIN rail. Refer to the power supply instruction sheet for proper wiring techniques and safety. 1.2 Run a lead from the inside "+" position on the output side of the power supply to the switch. 1.3 Run a lead from the inside " - " position on the output side of the power supply to the switch. 1.4 Terminate the leads to the switch per the instructions provided by the switch manufacturer. Note: Verify the switch being installed is 24 VDC. 1.5 If installing the optional fan, complete the following after the fan has been installed and wired. Use the Adhesive Backed Mounts and PAN-TYS to manage the wires and secure them to the inner panel. Save a couple adhesive mounts and PAN-TYS to manage and secure the incoming power lines to the inner panel. Note: Refer to figure 1 for an example of how the wires can be routed. Step 2: Gland Plate Installation (sold separately) PANDUIT Part # s: IAECGP - Industrial Automation Enclosure Connector Gland Plate (1) Gland Plate (14) Patch Cords (8) #10-32 Nuts (1) Gland Plate Gasket (8) #10 Flat Washers (14) IP67 Bulkheads (8) #10 Split Lock Washers IAEBGP - Industrial Automation Enclosure Blank Gland Plate (1) Blank Gland Plate (8) #10 Flat Washers (8) #10-32 Nuts (1) Gland Plate Gasket (8) #10 Split Lock Washers 1 Adhesive Mount Area for Switch 2 Power Supply 2.1 Insert the studs of the gland plate through the holes on the enclosure. 2.2 Verify the gland gasket is flat and positioned evenly between the plate and the enclosure. 2.3 Secure the plate to the enclosure using the supplied #10 Flat Washers, #10 Split Lock Washers and #10-32 Nuts. Torque the nuts to 5 in-lbs. Step 3: Optional Fan Kit Installation (sold separately) PANDUIT Part #: IAEFK54 - Industrial Automation Enclosure Fan Kit (1) IP54 Fan (1) Thermostat (1) IP54 Exhaust Filter 3.1 Remove the cover plates from the enclosure. 3.2 Snap the IP54 Fan from the outside into the bottom opening near the gland plate. Make sure the louvers are angled toward the bottom of the enclosure. 3.3 Snap the IP54 Exhaust Filter from the outside into the top opening of the enclosure. Make sure the louvers are angled toward the bottom of the enclosure. 3.4 Install the Thermostat to the DIN rail of the enclosure. 3 Fan Thermostat Exhaust Filter Page 2 of 5

Step 4: Wiring Optional Thermostat and Fan 4.1 Refer to the power supply instruction sheet for proper wiring techniques and safety. 4.2 Run a lead from the outside "+" position on the output side of the power supply to the 1 position of the thermostat. 4.3 Run the positive lead of the fan to the 2 position of the thermostat. 4.4 Run the negative lead of the fan to the outside " - " position on the output side of the power supply. 4.5 Use the adhesive mounts and PAN-TYS to manage the wires and secure them to the inner panel. Save a couple adhesive mounts and PAN-TYS to manage and secure the incoming power lines to the inner panel. 4 Step 5: Wiring the Input Side of Power Supply 5.1 Refer to the power supply instruction sheet for proper wiring techniques and safety. If the power supply is not being connected to the incoming power at this time, cover the hole using the provided Electrical Hole Seal. 5.2 Connect the hot wire to the "L" on the input side of the power supply. 5.3 Connect the neutral wire to the "N" on the input side of the power supply. 5 Page 3 of 5

Step 6: ing Installation 6.1 Connect the incoming ground cable to the ground stud on the base of the enclosure. Use the remaining adhesive mounts to manage and secure the hot wire, neutral wire and incoming ground cable to the inner panel. 6.2 Using one of the supplied ing s, attach one end to the grounding stud on the base, on top of the incoming ground, and the other end to the grounding stud on the door. 6.3 A second ing is to be attached to the grounding stud on the base, on top of the other two cables, and the other end will be secured to the inner panel as shown in Figure 6B. 6.4 Secure the cable ends to the grounding studs on the base and the door using the supplied #10 Spring Lock Washers and #10-32 Hex Nuts. 6.5 The third ing is to be attached to the grounding position on the switch and the other end will be secured to the inner panel. 6.6 The 12 AWG ing is to be attached to the power supply and the inner panel. The end without a terminal should be attached to the power supply. Refer to the power supply instruction sheet for proper wiring techniques and safety. 6.7 Secure the three grounding cables (base, switch and power supply) to the inner panel using the supplied #10-32 x 1/2" Pan Head Screw and #10 Spring Lock Washer. 6A 6B Door Incoming Base 12 AWG Secure s Here Inner Panel Page 4 of 5

Step 7: Patch Cord Installation 7.1 Insert the connector end of the patch cord into an IP67 bulkhead. 7.2 Insert the plug end of the patch cord into the corresponding port on the switch. 7.3 Insert the provided TAK-TYS through the shear forms on the inner panel to manage and secure the patch cords within the enclosure. 7 (Switch) Patch Cord TAK-TY For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 5 of 5 E-mail: cs@panduit.com Fax: (708) 444-6993