Ideal for industrial and commercial applications arge range of heat outputs and burner options Easy installation with a factory fitted bolt-on burner Durable long life stainless steel combustion chamber Design flexibility - floor standing, horizontal mounting or external site installation options All models meet ECA efficiency requirements Over 9.5% NET Efficient! Cabinet Heaters Quality in Any anguage TM 006
Technical Data PP ECA (Power as) & POP ECA (Pressure Jet Oil) Ranges Natural as (20) & P Propane () Data Cabinet Heaters Model 5 20 0 40 50 60 70 80 Maximum (kw) 56 7 9 0 62 208 242 275 49 Heat Input-ross (Btu/h) x (0) 89 250 8 44 55 70 826 99 89 Maximum Heat Output (kw) 47 6 78 0 5 78 205 20 29 (Btu/h) x (0) 62 209 267 76 459 607 700 786 Reduced ross Input* (kw) 9 5 65 9 46 69 9 244 (Btu/h) x (0) 75 222 0 87 497 578 657 82 Reduced Output* (kw) 4 55 77 94 24 44 6 205 (Btu/h) x (0) 46 87 26 2 425 490 550 70 Maximum as Rate (m /h) 5. 7.0 8.9 2.4 5.4 9.8 2. 26.2.2 Natural (20) (ft /h) 87 247 4 48 546 70 86 928 75 Minimum as Rate (m /h).8 5.0 6. 8.8.0 4.2 6.5 8.7 2.7 Natural (20)* (ft /h) 4 77 225 90 50 58 66 840 Maximum as Rate (m /h) 2. 2.8.5 4.9 6. 7.8 9. 0.4. P Propane () (kg/h)**.9 5. 6.5 9.. 4.5 6.9 9.2 24. Minimum as Rate (m /h).5.9 2.5.4 4. 5.5 6.4 7. 9.2 P Propane () (kg/h)** 2.7.6 4.5 6. 7.9 0..8.4 7.0 Inlet Pressure Natural as (20) (mbar) 20 (Minimum: 7; Maximum: 25) Inlet Pressure P Propane as ()(mbar) 7 (Minimum: 25; Maximum: 45) as Connection (ISO 7-R) * High/ow and Modulating Burners Only **For litres per hour, multiply: (kg/h) x.97 Oil Data (Class D Fuel Oil) Model 5 20 0 40 50 60 70 80 Heat Input (kw) 56 7 9 0 62 208 242 275 49 (Btu/h) x (0) 89 250 8 44 55 70 826 99 89 Heat Output (kw) 47 6 78 0 5 78 205 20 29 (Btu/h) x (0) 62 209 267 76 459 607 700 786 Consumption (/h) 5.2 6.8 8.7 2. 5. 9.4 22.5 25.6 2.4 (gal/h)..5.9 2.7. 4. 5.0 5.6 7. Oil Pump Connections (ISO 7-Rc) eneral Data Model 5 20 0 40 50 60 70 80 Electrical Supply* 20 V/50 Hz/ Ø 400 V/50 Hz/ Ø Main Fan Motor Type DD DD DD DD DD BD BD BD BD Motor Size (kw) 0.75 0.75 0.75 2.2 2.2.5 2.2 2.2 4.0 Start Current (A) 24 24 28 2 2 0.2 0 0 5.0 Run Current (A) 5. 5. 6. 6.2 6.2.5 5. 5. 9.6 Airflow - (m /h) 98 98 5097 6796 8495 044 244 244 70 Free Blowing (ft /min) 2000 2000 000 4000 5000 6500 7500 7500 0200 DD = Direct Drive BD = Belt Drive * Models 40 & 50 are available with 20 V Ø electrical supply as an extra cost option.
Dimension Data PP ECA & POP ECA Front View All Models Side View Models 5-50 Side View Models 60- Rear View All Models D D E C 70 A 8 F B 8 70 8 F B 8 08 8 H 8 Model 5/20 0 40 50 60/700 A Width (mm) 724 724 857 857 06 06 B Depth Cabinet Only (mm) 857 857 857 06 676 994 C Height Cabinet Only (mm) 740 740 90 90 90 90 D Depth Overall (mm) 267 267 7 496 256 2496 E Height Inc. Heads (mm) 988 2058 225 225 225 225 F eft/right Hand (mm) 78 78 78 940 600 98 Air Inlet Spigot - Depth eft/right Hand (mm) 457 457 560 560 560 559 Air Inlet Spigot - Height H Rear Air Inlet (mm) 648 648 78 78 na na Spigot - Depth J Rear Air Inlet (mm) 6 6 446 446 na na Spigot - Height Weight (kg) 200 200 245 270 440 50 Flue Diameter* (mm) 78 78 78 78 229 229 Heater Clearances to Combustibles (mm) To Side of Heater 600 To Rear of Heater 600 To Front of Heater 2000 For Air Distribution 4000 Note: Horizontal Cabinet heaters are designed to lie on their left hand side, as standard. *All heaters must be connected to a suitable flue system.
Dimension Data - External Heaters 50 P D 50 H J F C M 70 8 N 8 08 B E 8 K 8 A Model 5/20/0 40 50 60/700 A Width (mm) 724 857 857 06 06 B Depth Cabinet Only (mm) 857 857 06 676 994 C Height Cabinet Only (mm) 740 90 90 90 90 D Depth 0verall (mm) 96 498 657 248 2800 E External Heater Housing (mm) 7 474 474 69 69 F Width Overall (mm) 840 97 97 2 2 Air Outlet Spigot Depth (mm) 476 476 60 28 524 H Air Outlet Spigot Width (mm) 648 78 78 940 940 J Flue Spigot Diameter (mm) 20 20 20 254 254 K Rear Return/ (mm) 648 78 78 na na Fresh Air Inlet - Width Rear Return/ (mm) 69 469 469 na na Fresh Air Inlet - Height M eft/right Hand Return/ Fresh Air Inlet - Height (mm) 457 560 560 560 560 N eft/right Hand Return/ Fresh Air Inlet - Width (mm) 78 78 940 600 98 P Rear Of Heater (mm) 40 40 426 96 96 To Air Outlet Spigot* Note: *For models 60 -, the circular flue spigot is at the front of the heater with the rectangular air outlet spigot at the rear. COMBAT external cabinet heaters are designed to be sited externally, with heat ducted into the building. These models are fitted with a special metal rain drip cover and all cabinet joints are silicone sealed to ensure that the heaters are weatherproof.
Controls Each heater will require connection to a suitable remote control panel. This will require on-site wiring. Burner Options COMBAT cabinet heaters are fitted with On/Off burners as standard. High/ow burners are available as an option on all models, and a fully modulating burner is available as an option on all Natural as and P fired models. Inlet & Outlet Ducts Where there is a need for the heater to be connected to fresh air or air from an adjacent area, for its intake of distribution air, inlet duct connections can be provided. Note: When employing an inlet duct arrangement, there must be adequate provision for the supply of combustion air. Please contact Roberts-ordon for advice. As standard, each heater is supplied with the specified number of discharge heads for warm air distribution. If a heater is to be attached to ducting for warm air distribution, then an outlet duct spigot can be provided. In these instances, advice should be sought to ensure that proposed duct systems are compatible with the heater. Oil Connection Kit For all oil fired heaters, an oil line conection kit comprising: gate valve, spring operated fire valve, oil filter and connecting nipples is supplied for installation on site. COMBAT ECA Range Cabinet Heaters are high efficiency heaters and are listed on the Enhanced Capital Allowance Scheme 'Energy Technology Product ist'. Important Notice The equipment described in this Data Sheet is suitable for most commercial and industrial heating applications. However, in certain environments, particularly where there is a chlorinated atmosphere (e.g. near degreasing plant or other solvent processes), or a particularly dusty atmosphere, specialist advice should be sought at the design stage. Please consult Roberts-ordon. Roberts-ordon reserves the right to alter product specification details without notice. Installation Code: ROBERTS ORDON products are to be installed only in accordance with local laws, codes and regulations, and only by a contractor qualified in the installation and service of gas-fired heating equipment. Further Information: Applications, engineering and detailed guidance on systems design, installation and product performance is available through ROBERTS ORDON representatives. Please contact us for any further information you require, including installation, operation and service manuals. All warranties subject to Roberts ordon Standard Terms and Conditions.
Air Outlet & Flue Arrangements Vertical and Horizontal Heaters - Free Blowing Rear 5/20 0 40 50 60/700 65 65 20 229 Front 84 284 Notes: Models 5 and 20 are fitted with 9 inch diameter discharge heads as standard. Models 0 to are fitted with 4 inch diameter discharge heads as standard. Vertical and Horizontal Heaters - Air Outlet Spigots 5/20/0 40 50 60/700 Rear 8 8 K 8 8 8 K 8 4 4 68 Front 8 8 K 8 8 8 K 8 8 8 K 8 400 42 Outlet Spigot Dimensions Model 5/20/0 40 50 60/700 K Spigot Width (mm) 648 78 78 940 940 Spigot Depth (mm) 476 476 60 28 524 Roberts-ordon Oxford Street Bilston, West Midlands WV4 7E UK Telephone: +44(0) 902 494425 Fax: +44(0) 902 40200 Service Telephone: +44(0) 902 4987 Service Fax: +44(0) 902 40464 E-mail: uksales@rg-inc.com E-mail: export@rg-inc.com www.rg-inc.com Corporate Headquarters (USA): Roberts-ordon Telephone: + 76.852.4400 Fax: + 76.852.0854 Canadian Office: Roberts-ordon Telephone: + 905.945.540 Fax: + 905.945.05 2004 Roberts-ordon All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Roberts-ordon. Printed in U.S.A. CCHSUK 2M4-Rev C