MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Similar documents
up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25 Pb Proudly made in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Proudly assembled in U.S.A

Proudly assembled in U.S.A

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

97% Thermal Efficiency

Proudly assembled in U.S.A

DIVISION FINNED WATER-TUBE BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Models HD101 thru 2342B

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

DIVISION FINNED WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

WATER-TUBE POOL HEATERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Date: Project #: Engineer: Prepared By: Bid Date:

New Versa IC Platform

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

TABLE OF CONTENTS BRADFORD WHITE BOILERS

DIVISION FINNED WATER-TUBE WATER HEATERS

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Project Name: Location: Engineer: Contractor: I. GENERAL

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Suggested Specifications Prestige Excellence 110

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

FXLF-9. High Efficiency Water Heaters and Boilers

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

NO ONE PUTS MORE INTO THEIR POOL HEATERS

Raptor 320HB & 399HB Submittal Sheet

High Efficiency Commercial Gas Water Heaters

96% COMMERCIAL INDUSTRIAL HEATER. Condensing Gas Water Heating System. Thermal Efficiency

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Automatic Circulating Water Heaters

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

Revitalize Building Mechanical Systems (4619)

Boilers Variable Fire Boilers

Residential/Commercial Gas Condensing Tankless Models

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Tankless Condensing High Efficiency Water Heaters

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

C1050ES Tankless Water Heater

Raypak Residential Products

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

FINALLY GET THE FEATURES YOU WANT

Commercial Tankless Rack System

HIGH EFFICIENCY COMMERCIAL BOILERS

High Efficiency Pool and Spa Heater

C1210ES Tankless Water Heater

MASCOT II. Gas-Fired Wall-Mounted Combination Boiler & Water Heater

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

FTIIIC-10. Domestic Hot Water Heaters and Boilers

Residential Gas Tankless Water Heater

Commercial Tankless Rack System

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Boiler & Water Heater

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Commercial Gas Water Heaters

FXLF-4. High Efficiency Water Heaters and Boilers

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Transcription:

VERSA IC Control Platform up to99% Efficiency! Can be vented with: PVC, Centrotherm Polypropylene or Stainless Steel. MBTU s 300A 400A 500A 700A 850A CSA Certified Low Lead Content Less Than.25% Lead Ultra Low Emissions Proudly assembled in the U.S.A

Xtreme Outdoor Performance Up to 99% part load! =ucóêét `çåçéåëáåö=jççìä~íáåö=_çáäéê J=qÜÉ=dêÉÉå=`ÜçáÅÉ Raypak s XFyreT is a natural extension of our successful XThermT modulating vertical boiler line (1.0 to 4.0 Million BTUH). Raypak offers state of the art features not found in other condensing boilers and combines these desirable features into one complete boiler package. A new leading edge in integrated control platform, the VERSA ICT, fully integrates burner modulation, temperature control, outdoor reset, ignition, safety, and individual fault monitoring. VERSA ICT also includes a Modbus communication port as standard. XFyre is outdoor certified. Utilizing cabinet and control protection technology already proven in over 250,000 Raypak products, the XFyre is a seasoned veteran of outdoor environments. Mechanical engineers, architects and building owners now have extreme installation flexibility, high efficiency, space saving footprint, zero side clearance, direct vent capability, inexpensive PVC or Polypropylene venting, and full service access. Installers enjoy ease-of-commissioning, reliability, serviceability and long-term performance. Small space, no longer a problem. Raypak s vertical water connections allow the units to be installed side by side, further reducing the footprint on multi-boiler installations. Our compact design makes it possible to install up to 3.4 million BTUH in under 67 ft² of floor space, plus front and rear clearance. Tie them all together with our built-in VERSA ICT Control and you may have a boiler system with a 20:1 turndown that operates at up to 99% thermal efficiency! This is an Xtreme green retrofit system. ucóêé=`çãäìëíáçå=póëíéã Modulation is nothing new to Raypak. We have been honing our gas modulation experience for over 60 years. The Raypak XFyre will precisely track the heating load with its built-in VERSA ICT Integrated Control platform, eliminating costly overshooting. Utilizing the latest European technology for the combustion-components, the optimum fuel-air ratio is maintained throughout the entire range of the load-tracking operation. Our 5:1 turndown ensures efficiency is maintained throughout the firing rate and actually increases during part load, right when you want it! The XFyre automatically self-tunes to accommodate the widest range of gas supply pressures. The high quality integrated blower-gas valve is self-correcting and allows smooth operation with fluctuating gas supply pressures. The Raypak XFyre is cutting edge technology with atmospheric simplicity. 2 séåí=cäéñáäáäáíó Category IV - Category IV AHRI-certified 94% efficiency at full fire for hydronic boilers and CSA-certified 95% for domestic water heaters (Up to 99% at part load!). When the job requires high efficiency, XFyre meets your needs. Combined vent and combustion air duct length of up to 200 equivalent feet. s H7-300A thru 500A and WH7-300A thru 850A are certified to use PVC, CPVC, polypropylene or stainless steel for your project, depending on the return water temperature. The units above ship PVC-ready. The D-33 kit adapts the unit in the field for CentrothermT Polypropylene. s H7-700A and H7-850A require the use of stainless steel venting only. héó=cé~íìêéë 5 models from 300,000 to 850,000 BTUH 94% thermal efficiency hydronic AHRI and 95% water heaters CSA CSA Low Lead Certified All models CSA indoor/outdoor certified Small footprint, less than 9-1/2 square feet Top water connections - allows side by side installation All models are equipped with 316L welded stainless steel heat exchanger and copper plumbing. ASME Section IV constructed and stamped. National Board registered. Multiple pump outputs - Boiler, System, and Indirect Dual flame sensing - Remote flame sensor and spark ignition rod Modulating gas valve and burner, up to 5:1 turndown Meets all current Low NOx regulations, less than 20ppm Whisper-quiet operation On-board diagnostic center, real English, no codes. 0-10 VDC BMS Interface (setpoint or direct drive) Built-in cascade function for up to 4 boilers Built-in outdoor reset functionality Complete cabinet protects all controls and wiring Tough rust-resistant powder coat finish Easy to service - air filter Most models certified for PVC*, CPVC, polypropylene, or stainless vent. H7-700A and H7-850A require stainless venting. *Max 170ºF return water & Max 180ºF setpoint at 9.0% CO2. Suitable for altitudes up to 10,000 ft. (derate may apply) Modbus BMS port léíáçåë Outdoor air sensor (B-32) Indirect sensor TruSealT direct vent kit (D-21 factory installed, D-22 Loose) Condensate treatment kit (Z-12)

700 1. Water Inlet As low as 50 F entering. All copper and brass factory installed vertical plumbing connections. Vertical plumbing allows boilers to be installed side by side or in tight places if need be. Male NPT connections. 2. Water Outlet All copper and brass factory installed vertical plumbing connections. Male NPT connections. 3. Direct Spark Ignition XFyre's state-of-the-art combustion control system utilizes the finest dual electrode igniter to start the combustion cycle. After ignition, the spark rod also acts as a second flame sensor. 4. VERSA ICT Board The VERSA ICT, Integrated Control system is CSA listed and certified as a combined temperature, safety, and ignition control device. Easy front access to all field wiring. This includes outdoor sensor, DHW sensor, system alarm, Modbus BMS port and 0-10V DC input connections. Each unit comes factory equipped with cascade control capability. Simple, quick access cascade of up to 4 boilers, link to Raypak Temp Tracker Mod+ Hybrid Master control for up to 16. 4a. Control Interface Large easy to read (3.5 ) LCD display. Will continuously monitor flame strength (µa) sensor temps, BMS signal (0-10V) set points, DeltaT, all safety signals, full diagnostics and fault history for last 15 events. Simple touch pad settings. Everything you need from set-up to service is at your fingertips, all in one location. 5. Air Fuel Ratio Gas Valve XFyre uses a German, precision manufactured, main gas valve considered by most to be second to none. This high tech gas valve works in perfect unison with the combustion air blower. The result is smooth and quiet light-offs while delivering a 5:1 turn down. With this much flexibility, XFyre is the right boiler for almost any size job. 6. Intake Air Filter Every XFyre comes standard with a front access, easy to service Merv 8 media, combustion air filter. 7. Manual Reset High Limit This function is fully integrated into the VERSA ICT control platform. (Not Shown) 8. Condensate Trap The XFyre has a built-in condensate trap located at the rear of the unit. The trap and the overfill condensate sensor are accessible through their own access panel. 9. Vent Switch Senses possible obstructions in the flue vent pipe. (Not Shown) 10. Flow Switch The XFyre keeps its flow switch safe and dry inside the cabinet, which protects it during shipping and in the boiler room. 11. Duo Style Heat Exchanger The XFyre uses a combined 316L stainless steel dual chamber condensing and non condensing heat exchanger. Weld-sealed technology eliminates gaskets and o-rings. Special glycol seals are not required for hydronic applications. ASME Section IV constructed and stamped. National Board registered. 12. Flame Sense Electrode After a call for heat, separate flame electrode monitors flame rectification. This helps to ensure proper carry over while also constantly monitoring the flame. (Not Shown) 13. Internal TruSealT Connection Allows the XFyre to be direct vented up to 200 combined equivalent feet (vent and air intake) in a horizontal or vertical vent system. (Not Shown) 14. Smart Blower Technology Utilizing a whisper quiet, all metal, technologically advanced combustion blower. Air and fuel are precisely mixed. 15. Weather-Proof Jacket Heavy gauge galvanized steel with a UV-resistant Polytuf powder coat finish is impervious to weather and corrosion. Raypak has one of the finest, top-of - the-line powder coat systems on the west coast regardless of industry. We laugh at a 1000 hour salt spray test. Independent test documentation available upon request. (Not Shown) Think Green Think Raypak 3

Xtreme Access The XFyre is purpose built for the contractor and service professional. 8 4 7 Completely serviceable from the front, top and both sides! 1. Flue Outlet Category IV. Most models certified for PVC, CPVC, polypropylene and stainless steel. These XFyres ship PVC-ready, no extras to purchase! s H7-700A and H7-850A require stainless vent. (PVC vent requires max 170 F return water & max 180ºF setpoint at 9.0%CO 2 ) 2. High Voltage Wiring Box 120VAC main incoming power connections. Boiler pump, system pump, and indirect DHW pump wiring. 3. Gas Inlet The XFyre will operate at 100% full rate with gas pressures as low as 4.0 w.c. 4. Condensate Drain and Trap 3/4 -NPT PVC connection for condensate removal. Inset photo shows condensate trap, overfill sensor and pressure switch for the flue. Raypak offers optional condensate treatment kits (option Z-12) that can be plumbed between the heater and the drain. 5. Direct Vent Capability Every XFyre is direct vent capable. By installing an optional combustion air adapter, your XFyre is ready for direct vent. For factory installation, order (option D-21) TruSealT at time of order. 6. Easy Access Rating Plate Location 7. Gas Valve Raypak uses German-made, high-quality gas valves, considered the finest modulating gas valves produced today. To the right of the gas valve is the boiler computer control center, which always keeps the blower, gas valve, direct spark ignition and flame supervision in perfect harmony. 8. Inlet and Outlet Connections and Flow Switch The vertical inlet and outlet connections are all copper and brass fitted with NPT male pipe thread connections. The flow switch is fully contained within the cabinet, protecting it from the elements and boiler room mishaps. Servicing of the Flow switch can be done from the top or left side. 9. Air Filter Simple front access; just remove the front door. The filter just slides right out for quick and easy inspection and replacement. The high-capacity filter is rated MERV 8. 10. Low Voltage Knockouts Separate conduit location for all sensor, communication, and low-voltage wiring to keep them as far away from the line voltage as possible. 1 9 4 Poly Vent PVC Vent Remove Front Door Loosen wing-nuts FRONT ACCESS INTAKE AIR FILTER Pullout filter media

Xtremely Small Footprint PHYSICAL DATA A Length F Mounting G NPT Dimensions (in.) H NPT K Flue Ø For installations at elevations above 2,000 feet, derate may apply, please consult the factory for additional instructions. No mechanical changes required up to 10,000 feet. T C/A Ø 300A 28-1/4 27-9/16 3/4 1-1/2 4 4 8-1/2 410 4.3 3 400A 30-3/4 29-3/4 1 2 4 4 7 465 4.7 4 500A 37-1/4 36-1/4 1 2 4 4 8-1/2 505 5.7 4 700A 47-3/4 47-1/16 1-1/4 2 6 6 10-5/8 550 7.3 5 850A 54-1/4 53-9/16 1-1/4 2 6 6 10-5/8 580 8.3 5 W Ship Weight (lbs.) Foot- Print (ft 2 ) Amps* *Current Draw is for heater only. (Supply breaker must have delayed trip.) MBTUH MBTUH Input Boiler (AHRI Certified) Output Efficiency MBTUH Input Water Heaters (CSA Certified) Output Efficiency Minimum Input 300A 300 282 94% 300 285 95% 60 400A 399 375 94% 399 379 95% 80 500A 500 470 94% 500 475 95% 100 700A 700 658 94% 700 665 95% 140 850A 850 799 94% 850 808 95% 170 CLEARANCES Heater Side Certified Minimum Service Minimum Front 24 24 Rear 24 24 Right 0 0 Left 0 0 Top 12 24 Floor* 0 --- Vent 1 --- *Do not install on carpeting Note: Local codes may require increased clearances XFyre Standard Pump s H WH HP Amps HP Amps 300A 0012-1/8hp 1.3 1611-1/4hp 5.7 400A 0012-1/8hp 1.3 1630-1/2hp 6.9 500A 1611-1/4hp 5.7 1630-1/2hp 6.9 700A 1630-1/2hp 6.9 1634-1hp 14.0 850A 1630-1/2hp 6.9 1634-1hp 14.0 Note: Current draw (Amps) is for pump only Max 75 equivalent feet Water hardness above 15 gpg requires water softener. 5

Xtremely Easy to Wire NOMs^`=táêáåÖ=`ÉåíÉê EêÉ~ê=çÑ=ÄçáäÉêF uíêéãéäó=b~ëó=íç=táêé=cêçåí=`çåíêçä mäìöë=cçê=póëíéã=`çååéåíáçåë XFyre has a front-mounted wiring center with plug connections for all low-voltage control systems and sensor connections. The VERSA ICT will allow cascading of up to four boilers, or DHW direct system, or if required a priority-based indirect DHW system. If additional boilers are needed it may be linked through its Modbus port to Raypak s Temp Tracker Mod+ Hybrid Master Control, to sequence up to 10 boilers. Also accepts 0-10VDC from BMS. NOMs^`=táêáåÖ=`ÉåíÉê The XFyre s 120VAC wiring center is located on the rear of the boiler. All incoming line voltage and pump wiring are contained away from the 24v control wiring. Wiring the boiler is simple and straight forward. içï=sçäí~öé táêáåö=`éåíéê eóçêçåáå=_çáäéê TYPE H XFyre Rates Of Flow And Pressure Drops 20 F 30 F 35 F Minimum Flow* GPM DP GPM DP GPM DP GPM DP DT Maximum Flow GPM DP DT 300A 28 17 19 8 16 6 14 5 39 36 28 16 400A 38 18 25 7 21 5 19 4 39 47 29 16 500A 47 16 31 7 27 5 24 4 39 56 23 17 700A 66 30 44 13 38 9 34 7 39 70 34 19 850A 80 40 53 17 46 12 41 10 39 80 40 20 *Closed systems only t~íéê=eé~íéê TYPE WH XFyre Water Hardness 3-15 Grains Per Gallon DT GPM DP MTS SHL GPM DP DT Flow Rates Minimum Flow Maximum Flow GPM DP DT 300A 24 24 12 1.5 17 20 9 29 36 28 16 400A 20 38 18 2 20 26 8 29 47 29 16 500A 20 48 16 2 19 33 8 29 56 23 17 700A 20 67 30 2 36 46 14 29 70 34 19 850A 23 70 30 2 36 56 19 29 80 40 20 MTS = Minimum Tube Size, inch. SHL = System Head Loss, ft (based on max 75 equivalent ft. of piping). DT = Temperature rise, F DP = Pressure drop through heat exchanger, ft Do not use when hardness exceeds 15 grains per gallon 6 TYPE WH XFyre 20 30 Recovery Rates Temperature Rise ( F) 40 50 60 70 80 90 300A 1728 1151 863 691 576 494 432 384 345 400A 2297 1532 1149 919 765 656 575 511 459 500A 2879 1919 1440 1151 959 823 720 640 576 700A 4031 2687 2015 1612 1344 1151 1008 896 806 850A 4894 3262 2446 1958 1632 1398 1224 1087 978 100

Xtreme Control _çáäéê=`çåíêçä=~åç= låj_ç~êç=aá~öåçëíáå=`éåíéê VERSA ICT merges safety, ignition and temperature control, outdoor reset and freeze protection, plus system monitoring, alarm and diagnostics, and BMS transmission all in one Integrated Control Platform. Easy front access to read, set up and troubleshoot on a 3.5 LCD screen. The entire package is CSA certified, and listed for each individual function. Inlet and outlet sensors factory-installed in boiler. Remote sensor for system included. BMS all point diagnostics transmission port. 0-10V DC setpoint input standard. Also can drive and monitor external motorized auxiliaries such as extractors and louvers. Additional connections for auxiliary functions indirect DHW, and dry contact remote alarm relay are provided. lìíçççê=mêçîéå= Raypak is no stranger to the outdoor environment. Our touchpad is 100% waterproof and has been proven and perfected on our pool products. No guesswork here, just one tough boiler ready to take on jobs that others have to walk away from. aá~öåçëíáå=fåñçêã~íáçå Safety Faults Sensor Failure - 6 Condensate Full Vent Temp Limit Low Water Level Low Water Flow High Temperature Limit Low Gas High Gas ΔT Error Blower Failure Blower Speed Low 24v Power History to 15 Faults Ignition Control Faults Ignition Failure False Flame Sense Xtreme Firing Rates `~ëå~çé=ìé=íç=q=_çáäéêë= aéäáîéê=ìé=íç=pkq=jáääáçå=_qr=~í=~=omwn=íìêåççïå=ê~íé> The XFyre comes standard with a built-in Cascading Boiler Control. No other controls to buy, just connect the units together in parallel with 2 wires (not supplied) that connect to the front-mounted low-voltage wiring board. Designate a Cascade Master Boiler and set all the other boilers as Followers. It s that simple! The XFyre has built-in Lead Rotation control. This allows rotation of the starting boiler so all boilers in the system remain active and the run times remain equal on each unit. 7

TM Water Heaters (Type WH) Boilers (Type H) ASME Section IV, National Board Registered, 160 PSI H Stamp v v eb^q=bu`e^kdbo g^`hbq lqebo GAS TRAIN p^cbqfbp lmbo^qfkd=`lkqolip Heat Exchanger Tubes 316L Stainless Steel v v Stainless Steel CSA Certified CA AB-1953 low lead v v Pressure Relief Valve 60 PSI V v (loose) 125 PSI v V 30, 45, 75, 150 PSI V V Temperature & Pressure Gauge (Loose) v v Pump 120V, Single-Phase V V Indoor/Outdoor Certified v v Vent Terminal Outdoor V V Through-the-Wall V V Fully-Enclosed Controls v v Combustible Floor Rated v v 120V Power Supply v v On/Off Switch v v Programmable Pump Time Delay, Single-Phase Included in Controller v v Terminal Block Connections Enable / Disable v v (Front mounted) 0-10 VDC Setpoint/Direct Drive Input v v LCD diagnostic display with 15-Event History v v VERSA ICT Control System (up to 5:1 Turndown) v v (Cascade up to 4 heaters) Outdoor Reset Sensor N/A V DHW Indirect Sensor N/A v External Multiple Boiler Controllers TempTracker Mod+ Hybrid V V (up to 5:1 Turndown) Direct Spark Ignition System 1-try V V 3-try v v High/Low Gas Pressure Switches V V Blocked Vent Switch v v High Limit Switch Manual Reset, Fixed v v Automatic Reset, Fixed V V Adjustable V V Low Water Cut-Off, 24V With Manual Reset and Test Buttons V V Flow Switch v v Combination Gas Valve v v Modulating Air Blower v v Additional Safety Valve Motorized (externally mounted) V V Solenoid (externally mounted) V V AHRI-Certified (H) 94% at Full Fire N/A v CSA-Certified Efficiency (WH) 95% at Full Fire v N/A 99% at Part Load v v Air Filter v v TruSeal Direct-Vent V V Alarm Contacts v v CSD-1 / GE GAP Control System V V Low NOx Meets all current requirements v v Condensate Drain and Trap v v Condensate Treatment Kit (Sales Option Z-12) V V v v = Standard V V = Optional LLC Raypak, Inc. 2151 Eastman Avenue, Oxnard, CA 93030 phone: (805) 278-5300 fax: (800) 872-9725 www.raypak.com 2009-2018 Raypak, Inc. Cat. No. 1000.22M Effective: 01-01-18 Replaces: 09-27-17