Varian, Inc. Vacuum Technologies. Diffusion Pumps. Feature and Benefits Typical Applications Pump Models

Similar documents
Varian, Inc. Vacuum Technologies. Diffusion Pumps. Features and Benefits 2-3. Typical Applications 4-5. Pump Models Fluids

AGILENT DIFFUSION PUMPS. 2-3 Features and Benefits 4-5 Typical Applications 6-29 Pump Models 30 Fluids 31 Baffles Technical Notes

INLET PRESSURE - TORR

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

Maintenance and Troubleshooting of Oil Diffusion Pumps

Custom Products Gallery

Scientific vapor pumps

VHS-10 & VHS-400 Diffusion Pumps

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

Vacuum Pumping process for Large Camera Dewars supplied by PixelVision of Oregon

Vacuum Pumps America Inc. Dry Screw Vacuum Pump VSS Series

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

High Throughput Diffusion Pumps

High Va. High Vacuum Pumps. DIP / DIJ / OB / LEYBOJET Oil Diffusions Pumps

Specification Sheet. Equipment Model: BVAC-1200 Vacuum Furnace. Type. Chamber. Maximum Temperature 1250 C. Hot Zone

OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

Heat up ramp rate 100 degrees C per minute - empty chamber.

2016 Ideal Vacuum (505) V 1.1

Innovative Vacuum Solutions

Fast Cycle Water Vapor Cryopump

Oil Trap Cleaning Procedure

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Stable High Vacuum. Oil diffusion pumps Oil vapor jet pumps

AGILENT VS SERIES LEAK DETECTORS

cooled, Non-heated ATH 1603 M, DN 200 CF-F, External drive electronics, Water cooled, Non-heated

Fast Cycle Water Vapor Cryopump

UHV Flow Cryostats. Ultra High Vacuum Flow cry stats CRYO INDUSTRIES

VAC-U-DRY VACUUM DEHYDRATOR

Applications and Accessories, Cryo Pumps

Understanding Process Vacuum for Process Improvement

Vacuum Insulated Pipe

Cryopumps, Cryogenics

Vacuum Traps and Filters

VAC-U-DRY VACUUM DEHYDRATION SKIDS

AGILENT ION PUMP 200 The first ion pump with maximum pumping speed at low pressure

Oil-Sealed Rotary Vane Pumps

Strip/Clamp-On Heaters

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

EM Oil Sealed Rotary Pumps

3.5 Cryosurface & Cryogenic Feed-through Specification

Integrated Process Solutions. Series 49. Thermal Management System

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 630 BP BE (9803) 1

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

Operating manual Incl. Manufacturer s declaration. Diffusion pump. with optional baffle DIF 320 BP BE (9906) 1

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Operating Instructions incl. Manufacturer's Declaration. Diffusion pump. with optional baffle DIF 501 BP BE (0003) 1

Ulster Bank Business Achievers Award Emerging Technology

Vacuum for Research & Development

EQUIPMENT FOR OIL/PAPER DRYING AND STABILIZATION

APPLIED VACUUM TECHNOLOGY VACUUM PUMPS & SYSTEMS

High performance dry leak detectors ASM 182 TD+ ASM 192 T2D+ HELIUM LEAK DETECTORS 297 > 308

Diamond Windows & MCP Detectors for Synchrotron Applications

ACORE Filtration Co.,Ltd provides engineering,

Instruction Manual. B Issue B. next Pump Accessories

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

92831 TEL: (714) FAX:

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

VacIon Plus 20. Outline Drawing. Technical Specifications

Product Overview 2017 Innovative Vacuum Components and Systems for Versatile Applications

C19 UNIVEX. High Vacuum Experimentation Systems UNIVEX 300, UNIVEX 450 UNIVEX 350, UNIVEX 450 B Special plants

VacIon Plus 150. Outline Drawing. Technical Specifications. Dimensions: millimeters (inches) 6" O.D. CFF (NW100) (1.88) REF (14.

IMPORTANT CONSIDERATIONS

ELD500 PRECISION LEAK DETECTOR

Chemistry diaphragm pumps

Saintech Ion Beam Systems - Ion Current Monitor

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

Industrial Processing Solutions

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

Furnaces. High Temperature Box Furnaces Deluxe Muffle Furnaces Economy Muffle Furnaces... 38

Selection of Precise vacuum Pumps for the Systems with Diverse Vacuum Ranges By H. M. Akram Quaid-e-Azam University, Pakistan

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

Root's Blowers. Introduction. Options to Choose from: RUTA Vacuum Systems. Root's Blower Vacuum Pumps. Industrial Series WAU Blower Hydrocarbon Oil

Variable Temperature Microprobe Systems

Atlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm

SULLAIR DESICCANT DRYERS

MODULAR HIGH CAPACITY REFRIGERATED AIR DRYERS. GMRN & GMRC Series

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Hotwatt, established in 1952, began with the manufacturing of one product, the open coil heating element. Since then Hotwatt has expanded our product

Rotary screw Air compressors. Fixed Speed 5 15HP

Cartridge. SORB-AC Cartridge Pumps MK5 Series. Pump Body. Heater. Thermocouple. Flange. Electrical Connector

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

NEW. APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

INNOVATIVE WATER VAPOR CRYOPUMP TECHNOLOGIES PRODUCT CATALOG

Use Metal Bellows To Replace Springs Benefits of Precision Metal Bellows as Spring Replacements in Mechanical and Electrical Applications

MODEL: DB500-X DESIGNED FOR QUICK & EASY DIE CHANGES WITH INSERTABLE 3- PIECE DIE SETS

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Cold Energy Saver. Thermal Mass Cycling Refrigerated Air Dryers ( scfm)

Transcription:

Varian, Inc. Vacuum Technologies Diffusion Pumps Feature and Benefits 62-63 Typical Applications 64-65 Pump Models 66-89 Fluids 9-91 Baffles 92-94 Technical Notes 96-99 61

Diffusion Pumps Features and Benefits Varian has earned its position as the leading Diffusion Pump manufacturer in the world by listening to customer needs and by continuously improving the performance and reliability of our benchmark designs. Throughout our more than forty years of leadership in the industry, we have consistently produced pumps that provide the most efficient means of converting heat into pumping throughput. Our experience has allowed us to optimize the design of every element of the pump. As a result, Varian Diffusion Pumps offer you the lowest cost of ownership available for many high vacuum-pumping applications. Options to Address Your Needs Many applications have unique requirements. Varian can provide additional features such as Halo or custom baffles to eliminate additional backstreaming, and a Quick Cool Coil option to accelerate system cycle times. Easy to Maintain Maintaining uptime is critical so we have simplified operation and maintenance. A sight glass provides visual indication of status when cold or hot and under vacuum. A gauge port facilitates system troubleshooting. 62

Diffusion Pumps Fully Optimized Jet Using our long and varied experience Varian designs and produces vapor jets that deliver the highest throughput, pressure stability, and tolerable foreline pressure available, while reducing backstreaming to a minimum. Built for Production Volumes Our success is in helping you meet the exacting requirements of your production process. Our pumps deliver superior pumping at high pressure and high gas flow conditions, and handle gas load variations that are typical of large volume production. Diffusion Pumps Robust Boiler Design Through optimized boiler design, Varian pumps are stable and reliable under widely varying operating conditions. This temperature stability prolongs fluid life as well. Thermal protection switches prevent system over-temperature conditions. Low Cost of Ownership By providing the highest throughput available per unit of power, reduced cooling water requirements, and rugged, durable stainless steel construction, Varian delivers large volume pumping at the lowest total cost to you. World-class Service, Training and Support Varian s application consulting capability makes use of our unparalleled experience to identify the optimal solution for you. And we invite you to take advantage of our industry leading worldwide service and support programs and award winning Vacuum Training classes to maximize system uptime and productivity. Varian, Inc. Vacuum Technologies 63

Diffusion Pump Typical Applications Courtesy of Mill Lane Engineering Courtesy of Materials Research Furnaces, Inc. Vapor Diffusion Pumps Vacuum Furnaces Vacuum Furnace applications require pumps that have the ability to achieve and maintain low base pressures and the ability to handle. The full fractioning design of the Varian diffusion pumps allows vaporized fluid to be fractionated in the boiler and jet assembly. Contamination and decomposition products are pumped away and only the purist fluid reaches the top jet, assuring highest speed and lowest backstreaming. Metallizing In web and roll coating systems, Varian diffusion pumps have the ability to pump high gas loads making them the perfect choice for continuous production applications. Large Area Coating / Thin Film Deposition Due to it s simplicity, high performance and low initial costs, the diffusion pump remains a primary pumping mechanism for large area coating systems. The large pumps used in this application come equipped with sight glass and drain assemblies and are also available with ASA or ISO flanges. Coatings (Optical, Electronics, Protective) With low ultimate pressure, high speed, high throughput and high tolerable forepressure, Varian diffusion pumps are the best choice for developmental and production systems. Molecular Beams The foreline ejector stage provides high tolerable forepressure and a large surface area for efficient degassing of compressed fluid, while the foreline baffle minimizes fluid loss even under high throughput conditions. All Varian pumps incorporate an ejector stage as will as full fractionating jets. HS Series pumps create high speed and low ultimate pressure, high throughput and high tolerable forepressure and low backstreaming combine to make the HS series the best diffusion pump. Pumps are equipped with full thermal protection. 64

Diffusion Pumps Diffusion Pumps Application Notes for Diffusion Pumps As the worldwide diffusion pump market leader, Varian produces the most comprehensive family of pumps, ranging from 2 in. to 35 in. in diameter, and is the only broad-line, U.S.-based manufacturer. The diffusion pump is the most common type of pump for use in high vacuum applications. These vapor jet pumps are one of the oldest and most reliable ways to create a vacuum. Since the chamber itself has no moving parts aside from the oil droplets, a vacuum diffusion pump can operate with stability over long periods. In all diffusion pumps, a small amount of backstreaming occurs. Backstreaming is the migration of minute levels of oil that move in the opposite direction toward the inlet of the pump and into the process stream, which may be the stage of an electron microscope or a welding chamber. In some applications, minor backstreaming has no impact; in others, where the purity of materials is critical, backstreaming cannot be tolerated. For this reason, systems typically add an optically dense baffle of varying design to deflect oil particles before they can reach the process stream. Diffusion pumps are in wide use because they have several advantages: They are reliable, simple in design, operate without noise or vibration, and are relatively inexpensive to operate and maintain. In fact, diffusion pumping is still the most economical means of creating high-vacuum environments. These pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. With the proper choice of motive fluids, traps, baffles, and valves, diffusion pumps can be used in a wide variety of applications and over pressure ranges from 1 x 1-3 torr to 2 x 1-11 torr Key Features of Varian Diffusion Pumps include: High pumping speeds High throughput High forepressure tolerance Low ultimate pressure Excellent backstreaming characteristics Long-term reliability Varian, Inc. Vacuum Technologies 65

Diffusion Pump Models AX-65 HS-2 VHS-4 VHS-6 VHS-25 Previous Model Number 16 183 184 Speed, l/s (operating range) Air 65 16 75 1,55 2,125 Helium & Hydrogen 9 2 94 1,93 2,66 Maximum forepressure, Torr (mbar) No load.75 (1.).55 (.72).65 (.86).65 (.85).65 (.85) Full load.6 (.78).4 (.52).55 (.73).55 (.72).55 (.72) Maximum throughput, T-l/s (mbar-l/s) In operating range.19 (.25).6 (.8) 1.5 (2.) 2.4 (3.2) 2.6 (3.5) @ 1 x 1-2 Torr (1.3 x 1-2 mbar).3 (.4).7 (.93) 2.5 (3.2) 3.5 (4.5) 3.5 (4.5) Minimum recommended backing pump for maximum throughput, cfm (m 3 /hr).15 (.25) 5. (8.5) 1 (17) 17. (28.9) 17. (28.9) Backstreaming rate at inlet flange mg/cm 2 /min (standard cold cap)* 2 x 1-4 1 x 1-3 5 x 1-4 5 x 1-4 5 x 1-4 Warmup time, minutes 7 15 1 1 15 Cooldown time, minutes With quick cool coil, where applicable 3 1 1 1 Fluid charge 3cc 1 cc 3 cc 5 cc 1, cc Electrical requirements 1 ph 1 ph 1 ph 1 ph 3 ph 5/6 Hz 5/6 Hz 5/6 Hz 5/6 Hz 5/6 Hz 9/115/165/22 V 12/24 V 12/28/24 V 12/28/24 V 12/28/24 V Power, Watts 2/25 45 145 22 22 Cooling water, U.S. gpm (l/hr) at 6-8 F (15-26 C) N/A.1 (2).15 (3).25 (5).25 (5) * Refer to page 96 for a description of test methods. Refer to page 99 for discussion of pump performance with halo baffles. 66

Diffusion Pumps VHS-1 VHS-4 HS-16 HS-2 HS-32 NHS-35 185 164 165 167 169 Speed, l/s (operating range) 3,65 4,5 6, 1, 17,3 28, 4,56 5,625 7,5 12,5 21,625 35,.65 (.85).65 (.85).65 (.85).65 (.85).5 (.65).55 (.71).55 (.72).55 (.72).55 (.72).55 (.72).35 (.45).4 (.52) 6.3 (8.4) 6.3 (8.4) 9.5 (11.7) at 81 W 12.5 (16.7) 3 (4) 25 (33) 7.5 (1.) 7.5 (1.) 11.5 (15.3) at 81 W 18 (23.4) 35 (45.5) 35 (45.5) 3 (51) 3 (51) 8 (136) 1 (17) 3 (51) 3 (51) 5 x 1-4 1 x 1-3 1.5 x 1-3 1.5 x 1-3 7 x 1-4 5 x 1-4 Diffusion Pumps 15 3 45 6 6 25 25 48 85 18 18 1, cc 3 U.S. qts. 5 U.S. qts. 3 U.S. gal. 3 U.S. gal. (2.8 liters) (4.7 liters) (11.3 liters) (11.3 liters) 3 ph 3 ph 3 ph 3 ph 3 ph 5/6 Hz 5/6 Hz 5/6 Hz 5/6 Hz 5/6 Hz 5/6 Hz 28/24/38/48 V 28/24/38/48 V 24/415/48 V 24/415/48 V 24/415/48 V 24/415/48 V 44 44 81/96 12, 24, 24,.4 (8).4 (8) 1.5 (3) 1.5 (3) 4. (8) 4. (8) Varian, Inc. Vacuum Technologies 67

AX-65 Outline Drawing Dimensions: inches (millimeters) Technical Specifications Pumping Speed*, Operating Range 65 l/sec Air, 9 l/s He and H 2 Maximum Throughput.19T-l/s (.25 mbar-l/s) in operating range.3t-l/s (.4 mbar-l/s) @.1 torr Compression Ratio 4 x 1 7 (Air), 2 x 1 6 (helium) Operating Range 3 x 1-3 to <5 x 1-8 torr (3.9 x 1-3 to 6.5 x 1-8 mbar) Maximum Forepressure No load:.75 torr (1. mbar) Full Load:.6 torr (.78 mbar) Backstreaming Rate* With cold cap: < 2 x 1-4 mg/cm 2 /min With baffle: <2 x 1-5 mg/cm 2 /min Recommended Backing Pump 1.5 cfm (2.5 m 3 /hr) Warmup Time 7 minutes Cooldown Time 1 minutes Fluid Charge 3 cc Electrical Requirements 1 ph, 5/6 Hz, 9/115/165/22 VAC Pump Power 2/25 watts Air Cooling 3 cfm 68

Diffusion Pumps Speed Curve.75 9.6 Air speed (l/sec) 7 5 3.45.3.15 Throughput (Torr-l/sec) 1 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed/cold cap Pumping speed/halo baffle Throughput Diffusion Pumps Description Wt. kg (lbs) Part Number KF-5 ISO-6 3KAX-65 with standard cold cap, 3.6 (8.) L96731 L97731 115 V, 25 W AX-65 with internal baffle, 3.6 (8.) L967311 L977311 115 V, 25 W AX-65 with standard cold cap, 3.6 (8.) L96732 L97732 22 V, 25 W AX-65 with internal baffle, 3.6 (8.) L967312 L977312 22 V, 25 W AX-65 with standard cold cap, 3.6 (8.) L96733 L97733 115 V, 2 W AX-65 with internal baffle, 3.6 (8.) L967313 L977313 115 V, 2 W AX-65 with standard cold cap, 3.6 (8.) L96734 L97734 22 V, 2 W AX-65 with internal baffle, 3.6 (8.) L967314 L977314 22 V, 2 W AX-65 with standard cold cap, 3.6 (8.) L96735 L97735 9 V, 25 W AX-65 with internal baffle, 3.6 (8.) L967315 L977315 9 V, 25 W AX-65 with standard cold cap, 3.6 (8.) L96736 L97736 165 V, 25 W AX-65 with internal baffle, 3.6 (8.) L967316 L977316 165 V, 25 W NOTE All pumps have NW-16 foreline See page 9 for Santovac 5 diffusion pump fluid Mounted cooling fan included with each pump (P/N 6613138) Overtemperature thermal switch set to open at 365 F (182 C) Use 25W heater with polyphenyl ether fluids (such as DC-75 and Santovac 5). Use 2W heater for other fluids. Ordering Information Description Wt. kg (lbs) Part Number Accessories Santovac 5 diffusion pump fluid, 4 cc.5 (1.) 95451 Santovac 5 diffusion dump fluid, 65 cc.9 (2.) 695452 DC-74 diffusion pump fluid, 5 cc 1.4 (3.) 6954745 DC-75 diffusion pump fluid, 5 cc 1.4 (3.) 6954755 Internal baffle kit.9 (2.) R11665 Centering ring for inlet flange, NW5.5 (1.) KC5SB Centering ring for inlet flange, ISO-63.2 (.5) IC63SV Centering ring for foreline flange, NW16.2 (.5) KC16SB Instruction manual 6999162 Replacement Parts (one heater harness required per pump) 2 W, 115 V heater harness.5 (1.) L999437 (for use with DC-74 and DC-72) 25 W, 115 V heater harness.5 (1.) L999433 (for use with DC-75 and Santovac 5) 2 W, 22 V heater harness.5 (1.) L999438 (for use with DC-74 and DC-72) 25 W, 22 V heater harness.5 (1.) L999434 (for use with DC-75 and Santovac 5) 25 W, 9 V heater harness.5 (1.) L999431 (for use with DC-75 and Santovac 5) 25 W, 165 V heater harness.5 (1.) L999432 (for use with DC-75 and Santovac 5) Overtemperature thermal switch.5 (1.) L99641 (included with each heater harness) Pump ready thermal switch (optional).5 (1.) L99642 Varian, Inc. Vacuum Technologies 69

HS-2 Outline Drawing.84 DIA O.D. (21.3) 6 (152.4) 4.78 (121.4) 12.69 (322) Dimensions: inches (millimeters) Technical Specifications Pumping Speed*, Operating Range 16 l/s Air, 2 l/s He and H 2 Maximum Throughput.6 T-l/s (.8 mbar-l/s) in operating range.7 T-l/s (.93 mbar-l/s) @.1 torr Operating Range 3.7 x 1-3 to < 5 x 1-8 torr, (4.9 x 1-3 to < 6.5 1-8 mbar) Maximum Forepressure No Load:.55 torr (.71 mbar) Full Load:.4 torr (.52 mbar) Recommended Backing Pump 5 cfm (8.5 m 3 /hr) Backstreaming Rate*, Standard Cold Cap < 1 x 1-3 mg/cm2/min Warmup Time 15 minutes Cooldown Time 1 minutes (with quick cool coil) Fluid Charge 1 cc Electrical Requirements 1 ph, 5/6 Hz, 12/24 VAC Pump Power 45 watts Cooling Water Requirements.1 gpm (2 l/hr) at 6-8 F (15-26 C) Water Connections 1 8 in. FPT 7

Diffusion Pumps Speed Curve 2 1.6 Air speed (l/sec) 15 1 5 1.2.8.4 Throughput (Torr-l/sec) 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed Throughput Diffusion Pumps Ordering Information Description Wt. kg (lbs) Part Number Description Wt. kg (lbs) Part Number ASA With standard cold cap, 12 V 2. (9.) 829631 With standard cold cap, 24 V 2. (9.) 829632 Accessories Wt. kg (lbs) Part Number 332 Water-cooled baffle with ASA 1. (4.5) F945332 Nominal 2 in. ASA blank 5. (2.3) ASA6N mating flanges 2 in. ASA bored mating flanges 5. (2.3) ASA6353N Santovac 5 diffusion 2.5 (1.1) 695455 pump fluid, 5 cc DC-72 diffusion pump fluid, 5 cc 3. (1.4) 6954725 DC-74 diffusion pump fluid, 5 cc 3. (1.4) 6954745 DC-75 diffusion pump fluid, 5 cc 3. (1.4) 6954755 Instruction manual 6999115 NOTE Inlet flange: nominal 2 in. ASA flange with 6 in. OD Foreline flange:.84 in. diameter tube See page 92 for Baffles See page 9 for Santovac 5 diffusion pump fluid Replacement Parts (one heater required per pump) 45 W, 12 V heater 1. (.5) 64732125 45 W, 24 V heater 1. (.5) 6473215 Heater block (one required per pump) 21. (1.) 82921 Heater platen (one required per pump) 1. (.5) 8291831 Replacement o-ring kit, (5 Inlet flange 1. (.5) K377159 o-rings (butyl, 2-338)) Varian, Inc. Vacuum Technologies 71

VHS-4 Outline Drawing Dimensions: inches (millimeters) Speed Curve 1 5 Air speed (l/sec) 8 6 4 2 1-8 4 3 2 1 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Throughput (Torr-l/sec) Pumping speed/ Standard cold cap Pumping speed/ Extended cold cap Throughput Technical Specifications Pumping Speed*, Operating Range 75 l/s air, 94 l/s He/H 2 Maximum Throughput 1.5 T-l/s (2. mbar-l/s) in operating range, 2.5 T-l/s (3.2 mbar-l/s) @.1 torr Operating Range 2 x 1-3 to <5 x 1-9 torr (2.7 x 1-3 to <6.5 x 1-9 mbar) Maximum Forepressure No Load:.65 torr (.86 mbar) Full Load:.55 torr (.73 mbar) Recommended Backing Pump 1 cfm (17 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <5 x 1-4 mg/cm 2 /min Warmup Time 1 minutes Cooldown Time 1 minutes (with quick cool coil) Fluid Charge 3 cc Electrical Requirements 1 ph, 5/6 Hz, 12/28/24 VAC Pump Power 145 watts Cooling Water Requirements.15 gpm (3 l/hr) at 6-8 F (15-26 C) Water Connections 1 8 in. FPT Tee 72

Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type VHS-4 Pump ASA ISO ConFlat VHS-4 with standard cold cap 12 V 25. (55.) 864631 L625631 L618831 VHS-4 with extended cold cap 12 V 25. (55.) 8646311 L6256311 L6188311 VHS-4 with standard cold cap 28 V 25. (55.) 864636 L625636 L618836 VHS-4 with extended cold cap 28 V 25. (55.) 8646316 L6256316 L6188316 VHS-4 with standard cold cap 24 V 25. (55.) 864632 L625632 L618832 VHS-4 with extended cold cap 24 V 25. (55.) 8646312 L6256312 L6188312 Accessories Page Weight kg (lbs) Part Number 334 Water-cooled baffle with ASA flanges 92 4.5 (1.) F828634 334 Water-cooled baffle with ISO flanges 92 4.5 (1.) F828635 334 Water-cooled baffle with ConFlat flanges 92 4.5 (1.) F828636 Centering ring for ISO inlet flange, 16K.5 (1.) IC16SV Centering ring for ISO foreline flange, KF4.2 (.5) KC4SV Santovac 5 diffusion pump fluid, 5 cc 9 1.1 (2.5) 695455 DC-72 diffusion pump fluid, 5 cc 9 1.4 (3.) 6954725 DC-74 diffusion pump fluid, 5 cc 9 1.4 (3.) 6954745 DC-75 diffusion pump fluid, 5 cc 9 1.4 (3.) 6954755 Instruction manual 6999121 Replacement Parts (one heater required per pump) 145 W, 12 V heater.5 (1.) 6473425 145 W, 28 V heater.5 (1.) 6473421 145 W, 24 V heater.5 (1.) 6473425 Heater clamp (one required per pump) 1. (2.) 8816431 Replacement nickel heater wire.5 (.2) 6561791 Replacement o-ring kit, (3 inlet flange o-rings (butyl, 2-258)/ 1 fill and drain o-rings (Viton, 2-113).5 (1.) K377183 Thermal switch (set at 3 F 147 C).5 (1.) 6429625 Extended cold cap 95.5 (1.) F689831 Sight glass repair kit L89831 Basic sight glass cooling kit R152331 Extended sight glass cooling kit R12831 NOTE Inlet flange 4 in. ASA, foreline flange KF4 Inlet flange ISO 16K, foreline flange ISO KF4 Inlet flange 8 in. CFF, foreline flange 23 4 in. CFF Pumps with ISO flanges do not include required centering rings Diffusion Pumps Varian, Inc. Vacuum Technologies 73

VHS-6 Outline Drawing Dimensions: inches (millimeters) Speed Curve 2 5 Air speed (l/sec) 16 12 8 4 1-8 4 3 2 1 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Throughput (Torr-l/sec) Pumping speed/ Standard cold cap Pumping speed/ Extended cold cap Throughput Technical Specifications Pumping Speed*, Operating Range 1,55 l/s Air, 1,93 l/s He/H 2 Maximum Throughput 2.4 T-l/s (3.2 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar-l/s) @.1 torr Operating Range 1.5 x 1-3 to <5 x 1-9 torr (2 x 1-3 to < 6.5 x 1-9 mbar) Maximum Forepressure No Load:.65 torr (.85 mbar) Full Load:.55 torr (.72 mbar) Recommended Backing Pump 17 cfm (29 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <5 x 1-4 mg/cm 2 /min Warmup Time 1 minutes Cooldown Time 1 minutes (with quick cool coil) Fluid Charge 5 cc exact fluid charge available Electrical Requirements 1 ph, 5/6 Hz, 12/28/24 VAC Pump Power 22 watts Cooling Water Requirements.25 gpm (5 l/hr) at 6-8 F (15-26 C) Water Connections 1 8 in. FPT Tee 74

Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type VHS-6 Pump ASA ISO ConFlat VHS-6 with standard cold cap 12 V 34. (75.) 8582631 L619331 L6231 VHS-6 with extended cold cap 12 V 34. (75.) 85826311 L6193311 L62311 VHS-6 with standard cold cap 28 V 34. (75.) 8582636 L619336 L6236 VHS-6 with extended cold cap 28 V 34. (75.) 85826316 L6193316 L62316 VHS-6 with standard cold cap 24 V 34. (75.) 8582632 L619332 L6232 VHS-6 with extended cold cap 24 V 34. (75.) 85826312 L6193312 L62312 Accessories Page Weight kg (lbs) Part Number 336 Water-cooled baffle with ASA flanges 92 7. (15.) F827736 336 Water-cooled baffle with ISO flanges 92 7. (15.) F827737 336 Water-cooled baffle with ConFlat flanges 92 7. (15.) F827738 Santovac 5 diffusion pump fluid, 5 cc (exact pump charge) 9 1.1 (2.5) 695455 DC-72 diffusion pump fluid, 5 cc (exact pump charge) 9 1.4 (3.) 6954725 DC-74 diffusion pump fluid, 5 cc (exact pump charge) 9 1.4 (3.) 6954745 DC-75 diffusion pump fluid, 5 cc (exact pump charge) 9 1.4 (3.) 6954755 Centering ring for ISO inlet flange, 2K.5 (1.) IC2SV Centering ring for ISO foreline flange, KF5.2 (.5) KC5SV Instruction manual 6999122 Replacement Parts (one heater required per pump) 22 W, 12V heater.5 (1.) 64736125 22 W, 28V heater.5 (1.) 64736175 22 W, 24V heater.5 (1.) 64736225 Heater clamping assembly (includes clamping plate, cover plate, insulator) 8664331 Heater cover plate (one required per pump) 1. (2.) 86881 Heater insulator (one required per pump).2 (.5) 86871 Heater clamping plate (one required per pump).5 (1.) 868631 Replacement nickel heater wire.5 (1.) 6561791 Replacement o-ring kit: 3 inlet flange o-rings (butyl, 2-267)/ 3 foreline flange o-rings (butyl/2-332), 1 fill and drain o-rings (Viton, 2-113).5 (1.) K377184 Thermal switch (set at 3 F 147 C).5 (1.) 6429625 Extended cold cap 95.5 (1.) F64551 NOTE Inlet flange 6 in. ASA, foreline flange 1.5 in. ASA Inlet flange ISO 2K, foreline flange ISO KF5 Inlet flange 1 in. CFF, foreline flange 33 8 in. CFF Pumps with ISO flanges do not include required centering rings Diffusion Pumps Varian, Inc. Vacuum Technologies 75

VHS-25 Outline Drawing Dimensions: inches Technical Specifications Pumping Speed*, Operating Range 2,125 l/s Air, 2,66 l/s He/H 2 Maximum Throughput 2.6 T-l/s (3.5 mbar-l/s) in operating range, 3.5 T-l/s (4.5 mbar l/s) @.1 torr Operating Range 1.2 x 1-3 to <5 x 1-9 torr (1.6 x 1-3 to <6.5 x 1-9 mbar) Maximum Forepressure No Load:.65 torr (.85 mbar) Full Load:.55 torr (.72 mbar) Recommended Backing Pump 17 cfm (29 m 3 /hr) Backstreaming Rate*, Standard Cold Cap < 5. x 1-4 mg/cm 2 /min Warmup Time 1 minutes Cooldown Time 1 minutes (with quick cool coil) Fluid Charge 5 cc exact fluid charge available Electrical Requirements 1 ph, 5/6 Hz, 12/28/24 VAC Pump Power 22 watts Cooling Water Requirements.25 gpm (5 l/hr) Water Connections 1 8 in. FPT Tee 76

Diffusion Pumps Speed Curve 3 6 25 5 Air speed (l/sec) 2 15 1 4 3 2 Throughput (Torr-l/sec) 5 1-8 1-7 1-6 1-5 1-4 1-3 1-2 Inlet pressure (Torr) 1-1 1 1 Pumping speed Throughput Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number VHS-25 Pump VHS-25 with standard cold cap 12V 34. (75.) K54331 VHS-25 with standard cold cap 28V 34. (75.) K54336 VHS-25 with standard cold cap 24V 34. (75.) K54332 Accessories Santovac 5 diffusion pump fluid, 5 cc (exact pump charge) 1.1 (2.5) 695455 DC-72 diffusion pump fluid, 5 cc (exact pump charge) 1.4 (3.) 6954725 DC-74 diffusion pump fluid, 5 cc (exact pump charge) 1.4 (3.) 6954745 DC-75 diffusion pump fluid, 5 cc (exact pump charge) 1.4 (3.) 6954755 Instruction manual 699912 Replacement Parts (one heater required per pump) 22 W, 12 V heater.5 (1.) 64736125 22 W, 28 V heater.5 (1.) 64736175 22 W, 24 V heater.5 (1.) 64736225 Heater cover plate (one required per pump) 1. (2.) 86881 Heater insulator (one required per pump).2 (.5) 86871 Heater clamping plate (one required per pump).5 (1.) 868631 Replacement nickel heater wire.5 (1.) 6561791 Replacement o-ring kit: 3 inlet flange o-rings (butyl, 2-379), 3 foreline flange o-rings (butyl, 2-332)/1 fill and drain o-rings (Viton, 2-113).5 (1.) K377178 Thermal switch (set at 3 F 147 C).5 (1.) 6429625 NOTE Inlet flange: ISO 25F (bolted, o-ring seal) Foreline flange: ASA with 5 in. OD Varian, Inc. Vacuum Technologies 77

VHS-1 Outline Drawing Dimensions: inches (millimeters) Technical Specifications Pumping Speed*, Operating Range 3,65 l/s Air, 4,56 l/s He/H 2 Maximum Throughput 6.3 T-l/s (8.4 mbar l/s) in operating range 7.5 T-l/s (1. mbar l/s) @.1 torr Operating Range 1.7 x 1-3 to <5 x 1-9 torr at 44 W (2.3 x 1-3 to <6.5 x 1-9 mbar) Maximum Forepressure No Load:.65 torr (.85 mbar) Full Load:.55 torr (.72 mbar) Recommended Backing Pump 3 cfm (51 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <5. x 1-4 mg/cm 2 /min Warmup Time 15 minutes Cooldown Time 25 minutes Fluid Charge 1, cc Electrical Requirements 3 ph, 5/6 Hz, 28/24/38/48 VAC Pump Power 44 watts Cooling Water Requirements.4 gpm (8 l/hr) Water Connections 1 8 in. FPT Tee 78

Diffusion Pumps Speed Curve 4 12 Air speed (l/sec) 3 2 1 9 6 3 Throughput (Torr-l/sec) 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed/ Standard cold cap Pumping speed/ Extended cold cap Throughput Diffusion Pumps Description Wt. kg (lbs) Part Number ASA ISO ConFlat VHS-1 with standard 68 (15) F42637 L59237 L617637 cold cap, 28 V VHS-1 with extended 68 (15) F426317 L592317 L6176317 cold cap, 28 V VHS-1 with standard 68 (15) F42638 L59238 L617638 cold cap, 24 V VHS-1 with extended 68 (15) F426318 L592318 L6176318 cold cap, 24 V VHS-1 with standard 68 (15) F426326 L592326 L6176326 cold cap, 38 V VHS-1 with extended 68 (15) F426336 L592336 L6176336 cold cap, 38 V VHS-1 with standard 68 (15) F42639 L59239 L617639 cold cap, 48 V VHS-1 with extended 68 (15) F426319 L592319 L6176319 cold cap, 48 V Accessories Wt. kg (lbs) Part Number 33 Water-cooled baffle 9. (2.) F8631 with ASA flanges 33 Water-cooled baffle 9. (2.) F86311 with ISO flanges 33 Water-cooled baffle 9. (2.) F86312 with ConFlat flanges NOTE Inlet flange 1 in. ASA, foreline flange 2 in. ASA Inlet flange ISO 32K, foreline ISO 63K Inlet flange 161 2 in. CFF, foreline flange 45 8 in. CFF See page 9 Santovac 5 diffusion pump fluid Baffles and extended cold caps can be found on pages 92 and 95 respectively Ordering Information Description Wt. kg (lbs) Part Number Accessories (Cont'd) DC-72 diffusion pump fluid, 5 cc 2.8 (6.) 6954725 (two required) DC-74 diffusion pump fluid, 5 cc 2.8 (6.) 6954745 (two required) DC-75 diffusion pump fluid, 5 cc 2.8 (6.) 6954755 (two required) Centering ring for ISO foreline.5 (1.) IC63SV flange, 63K Instruction manual 6999123 Replacement Parts (two heaters required per pump) 22 W, 28 V heater.5 (1.) 6473114 22 W, 24 V heater.5 (1.) 6473115 22 W, 38 V heater.5 (1.) 6473116 22 W, 48 V heater.5 (1.) 6473117 255 W, 28 V heater.5 (1.) 64731145 255 W, 24 V heater.5 (1.) 64731155 255 W, 38 V heater.5 (1.) 64731165 255 W, 48 V heater.5 (1.) 64731175 Heater crush plate (replace one with 1. (2.) K76671 each new heater) Heater clamping plate (one required.5 (1.) K49281 per pump) Replacement nickel heater wire.5 (1.) 6561791 Replacement o-ring kit, (1 Inlet flange 1. (.5) K377185 o-ring, (butyl, F431)/1 foreline flange o-ring, (butyl, 2-338)/1 fill and drain o-rings, (Viton, 2-113)) Thermal switch (set at 3 F 147 C).5 (1.) 6429625 Extended cold cap 2. (.9) L891731 Varian, Inc. Vacuum Technologies 79

VHS-4 Outline Drawing Dimensions: inches (millimeters) Technical Specifications Pumping Speed*, Operating Range 4,5 l/s Air, 5,625 l/s He/H 2 Maximum Throughput 6.3 T-l/s (8.4 mbar l/s) in operating range 7.5 T-l/s (1. mbar l/s) @.1 torr Operating Range 1.4 x 1-3 to <5 x 1-9 torr (1.9 x 1-3 to <6.5 x 1-9 mbar) Maximum Forepressure No Load:.65 torr (.85 mbar) Full Load:.55 torr (.72 mbar) Recommended Backing Pump 3 cfm (51 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <1. x 1-3 mg/cm 2 /min Warmup Time 15 minutes Cooldown Time 25 minutes Fluid Charge 1, cc Electrical Requirements 3 ph, 5/6 Hz, 28/38/48 VAC Pump Power 44 watts Cooling Water Requirements.4 gpm (8 l/hr) Water Connections 1 8 in. FPT Tee 8

Diffusion Pumps Speed Curve Air speed (l/sec) 5 1 45 4 35 3 25 2 15 1 5 1-8 1-7 1-6 1-5 1-4 1-3 1-2 Inlet pressure (Torr) 9 8 7 6 5 4 3 2 1-1 Throughput (Torr-l/sec) 1 Pumping speed Throughput Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type VHS-4 Pump ASA ISO VHS-4 with standard cold cap 28 V 75. (18.) K481637 L976737 VHS-4 with standard cold cap 38 V 75. (18.) K4816326 L9767326 VHS-4 with standard cold cap 48 V 75. (18.) K481639 L976739 VHS-4 with standard cold cap 24 V 75. (18.) K481638 L976738 Accessories Page Weight kg (lbs) Part Number DC-72 diffusion pump fluid, 5 cc (two required) 3 2.8 (6.) 6954725 DC-74 diffusion pump fluid, 5 cc (two required) 3 2.8 (6.) 6954745 DC-75 diffusion pump fluid, 5 cc (two required) 3 2.8 (6.) 6954755 Centering ring for ISO Inlet flange, 4K.5 (1.) IC4SV Centering ring for ISO foreline flange, 63K.5 (1.) IC63SV Instruction manual 6999123 Replacement Parts (two heaters required per pump) 22 W, 28 V heater 1. (.5) 6473114 22 W, 24 V heater 1. (.5) 6473115 22 W, 38 V heater 1. (.5) 6473116 22 W, 48 V heater 1. (.5) 6473117 255 W, 28 V heater 1. (.5) 64731145 255 W, 24 V heater 1. (.5) 64731155 255 W, 38 V heater 1. (.5) 64731165 255 W, 48 V heater 1. (.5) 64731175 Heater crush plate (one required per pump) 2. (1.) K76671 Heater clamping plate (one required per pump) 1. (.5) K49281 Replacement nickel heater wire 1. (.5) 6561791 Replacement o-ring kit, 1 inlet flange o-ring (butyl, 2-385), foreline flange o-ring (butyl, 2-338), 1 fill and drain o-rings (Viton, 2-113) 1. (.5) K377189 Thermal switch (set at 3 F 147 C) 1. (.5) 6429625 NOTE Inlet flange ISO 4K, foreline flange ISO 63-K. Inlet flange non-standard ASA, foreline flange 2 in. ASA. Pumps with ASA flanges include O-Rings for inlet and foreline flanges Pumps with ISO flanges do not include centering rings required for inlet and foreline flanges. Varian, Inc. Vacuum Technologies 81

HS-16 Outline Drawing Dimensions: inches (millimeters) Speed Curve 8 2 Air speed (l/sec) 6 4 2 15 1 5 Throughput (Torr-l/sec) 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed/cold cap Pumping speed/halo baffle Throughput Technical Specifications Pumping Speed*, Operating Range 6, l/s air, 7,5 l/s He and H 2 Maximum Throughput 8,1 W 9.5 T-l/s (12.7 mbar l/s) in operating range 9,6 W 12. T-l/s (16 mbar l/s) in operating range 11.5 T-l/s (15.3 mbar-l/s) @.1 torr 13.5 T-l/s (18. mbar-l/s) @.1 torr Operating Range 2 x 1-3 to <5 x 1-8 torr at 9,6 W (1.3 x 1-3 to <6.5 x 1-8 mbar) Maximum Forepressure No Load.65 torr (.85 mbar), Full Load.55 torr (.72 mbar) Pump Power 81/96 watts Recommended Backing Pump 8 cfm (136 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <1.5 x 1-3 mg/cm 2 /min Warmup Time 3 minutes Cooldown Time 48 minutes (3 minutes with optional quick cool coil) Fluid Charge 3 quarts (2.8 liters) Electrical Requirements 3 ph, 5/6 Hz, 24/415/48 VAC Cooling Water Requirements 1.5 gpm (3 l/hr) at 6-8 F (15-26 C) Water Connections 1 4 in. FPT Tee Recommended Fluid DC-74 (see page 9) 82

Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type HS-16 Pump ASA ISO HS-16 with standard cold cap 24 V 218. (48.) 7929238 L592138 HS-16 with halo baffle 24 V 218. (48.) 79292318 L5921318 HS-16 with standard cold cap 415 V 218. (48.) 79292326 L5921326 HS-16 with halo baffle 415 V 218. (48.) 79292336 L5921336 HS-16 with standard cold cap 48 V 218. (48.) 7929239 L592139 HS-16 with halo baffle 48 V 218. (48.) 79292319 L5921319 NOTE The HS-16 can be ordered with 96 W heaters by increasing the middle number of the 3-digit suffix by two; eg 79292328 Accessories Page Weight kg (lbs) Part Number Water-cooled halo baffle 93 9. (2.) K143316 Water-cooled baffle with ASA flanges 93 8. (18.) R115231 Water-cooled baffle with ISO flanges 93 6. (13.) R115331 Centering ring for ISO inlet flange, 5K.5 (1.) IC5SV Centering ring for ISO foreline flange, 1K.5 (1.) IC1SV Instruction manual 6999114 Replacement Parts (three heaters required per pump) 27 W, 24 V/415 V with leads.5 (1.) 6473162 27 W, 48 V with leads.5 (1.) 6473163 27 W, 24 V/415 V no leads used on pumps built before May 199.5 (1.) 64731635 27 W, 48 V no leads used on pumps built before May 199.5 (1.) 64731645 32 W, 24 V/415 V with leads.5 (1.) 64731623 32 W, 48 V with leads.5 (1.) 64731633 Heater crush plate (replace one with each new heater).5 (1.) K49191 Heater insulator (three required per pump).5 (1.) 79391 Heater clamping plate (three required per pump) 8. (4.) K49171 Replacement o-ring kit for ASA pumps, 1 inlet flange o-ring, (buna, 482141)/ 1 foreline flange o-ring, (buna, 2-348)/8 fill and drain o-rings, (Viton, 2-213) 1. (.5) K377164 Upper thermal switch (set at 185 F/85 C) 1. (.5) K951 Lower thermal switch (set at 39 F/199 C) 1. (.5) K952 Heater Retrofit Kit (for pumps built before May 199) HS-16, 24 25. (11.35) L652638 HS-16, 415 25. (11.35) L6526326 HS-16, 48 25. (11.35) L652639 NOTE Inlet flange 16 in. ASA, foreline flange 3 in. ASA Inlet flange ISO 5K, foreline flange ISO 1K Not recommended for use with Santovac 5 Pumps with ASA flanges include o-rings for inlet and foreline flanges Pumps with ISO flanges do not include centering rings required for foreline and inlet flanges Diffusion Pumps Varian, Inc. Vacuum Technologies 83

HS-2 Outline Drawing Dimensions: inches (millimeters) Speed Curve 12 3 1 25 Air speed (l/sec) 8 6 4 2 15 1 Throughput (Torr-l/sec) 2 1-8 5 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed/cold cap Pumping speed/halo baffle Throughput Technical Specifications Pumping Speed*, Operating Range 1, l/s air, 12,5 l/s He and H 2 Maximum Throughput 12.5 T-l/s (16.7 mbar l/s) in operating range, 18 T-l/s (23 mbar-l/s) @.1 torr Operating Range 1.3 x 1-3 to 5 x 1-8 torr (1.7 x 1-3 to 6.5 x 1-8 mbar) Maximum Forepressure No Load:.65 torr (.85 mbar) Full Load:.55 torr (.72 mbar) Recommended Backing Pump 1 cfm (17 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <1.5 x 1-3 mg/cm 2 /min Warmup Time 45 minutes Cooldown Time 85 minutes Fluid Charge 5 quarts (4.7 liters) Electrical Requirements 3 ph, 5/6 Hz, 24/415/48 VAC Pump Power 12, watts Cooling Water Requirements 1.5 gpm (3 l/hr) at 6-8 F (15-26 C) Water Connections 1 4 in. FPT Tee Recommended Fluid DC-74 (see page 9) 84

Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type HS-2 Pump ASA ISO HS-2 with standard cold cap 24 V 264. (58.) 8434138 L592238 HS-2 with halo baffle 24 V 264. (58.) 84341318 L5922318 HS-2 with standard cold cap 415 V 264. (58.) 84341326 L5922326 HS-2 with halo baffle 415 V 264. (58.) 84341336 L5922336 HS-2 with standard cold cap 48 V 264. (58.) 8434139 L592239 HS-2 with halo baffle 48 V 264. (58.) 84341319 L5922319 Accessories Page Weight kg (lbs) Part Number Water-cooled halo baffle 93 11. (25.) K185532 Water-cooled baffle with ASA flanges 93 1. (215.) R115431 Water-cooled baffle with ISO flanges 93 7. (16.) R115531 Centering ring for ISO foreline flange, 16K.5 (1.) IC16SV Instruction manual 6999114 Replacement Part (six heaters required per pump) Heater, 2 W, 24 V/415 V with leads.5 (1.) 647322 Heater, 2 W, 48 V with leads.5 (1.) 647323 Heater, 2 W, 24 V/415 V no leads used on pumps built before May 199.5 (1.) 647326 Heater, 2 W, 48 V no leads used on pumps built before May 199.5 (1.) 647327 Heater crush plate (replace one with each new heater).5 (1.) K7181 Heater clamping plate (six required per pump) 4. (8.) K7171 Heater insulator (one required per pump).5 (1.) L65141 Replacement o-ring kit for ASA pumps, 1 Inlet flange o-ring, (butyl, 843492)/ 1 foreline flange o-ring, (buna, 2-432)/8 fill and drain o-rings, (Viton, 2-213).5 (1.) K377165 Upper thermal switch (set at 185 F/85 C).5 (1.) K951 Lower thermal switch (set at 39 F/199 C).5 (1.) K952 Heater Retrofit Kit (for pumps built before May 199) HS-2, 24 13.62 (3.) L639238 HS-2, 415 13.62 (3.) L6392326 HS-2, 48 13.62 (3.) L639239 NOTE Inlet flange 2 in. ASA, foreline flange 4 in. ASA Inlet flange ISO 63K, foreline flange ISO 16K Not recommended for use with Santovac 5 ASA version pumps include o-rings for both inlet to foreline flanges. Centering rings for ISO version pumps must be ordered separately. Diffusion Pumps Please note that this item is controlled for export by the Nuclear Suppliers Group. Accordingly, you may be required to obtain an export license from the U.S. Department of Commerce prior to exporting this diffusion pump from the United States. Please consult the U.S. Export Administration Regulations, ECCN 2B231, for further guidance. Varian, Inc. Vacuum Technologies 85

HS-32 Outline Drawing 26.5 (673) 68.5 (174) 46.75 (1187) Dimensions: inches (millimeters) Technical Specifications Pumping Speed*, Operating Range 17,3 l/s Air, 21,625 l/s He and H 2 Maximum Throughput 3 T-l/s (4 mbar l/s) in operating range, 35 T-l/s (45 mbar-l/s) @.1 torr Operating Range 1.7 x 1-3 to <5 x 1-8 torr (2.3 x 1-3 to <6.5 x 1-8 mbar) Maximum Forepressure No Load:.5 torr (.65 mbar) Full Load:.35 torr (.45 mbar) Recommended Backing Pump 3 cfm (51 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <7 x 1-4 mg/cm 2 /min Warmup Time 6 minutes Cooldown Time 18 minutes Fluid Charge 3 U.S. gallons (11.3 liters) Electrical Requirements 3 ph, 5/6 Hz, 24/415/48 VAC Pump Power 24, watts Cooling Water Requirements 4 gpm (8 l/hr) at 6-8 F (15-26 C) Water Connections 3 8 in. FPT Tee Recommended Fluid DC-74 (see page 9) 86

Diffusion Pumps Speed Curve Air speed (l/sec) 2 5 18 45 16 4 14 35 12 3 1 25 8 2 6 15 4 1 2 5 1-8 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Throughput (Torr-l/sec) Pumping speed/cold cap Pumping speed/halo baffle Throughput Diffusion Pumps Description Wt. kg (lbs) Part Number HS-32 Pump ASA ISO HS-32 with standard 612 (1,35) 7613438 L592338 cold cap, 24 V HS-32 with halo baffle, 24 V 612 (1,35) 76134318 L5923318 HS-32 with standard 612 (1,35) 76134326 L5923326 cold cap, 415 V HS-32 with halo baffle, 612 (1,35) 76134336 L5923336 415 V HS-32 with standard 612 (1,35) 7613439 L592339 cold cap, 48 V HS-32 with halo baffle, 48 V 612 (1,35) 76134319 L5923319 Accessories Wt. kg (lbs) Part Number Water-cooled halo baffle 16 (35) K1856332 Water-cooled baffle with ASA flanges 16 (35) R115631 Water-cooled baffle with ISO flanges 135 (3) R115731 Quick cool coil must be installed in K61751 the factory, can not ship separately Centering ring for ISO foreline.5 (1.) IC2SV flange, 2K Instruction manual 6999114 NOTE Inlet flange 32 in. ASA, foreline flange 6 in. ASA Inlet flange ISO 8F (bolted), foreline flange ISO 2K (clamped) Not recommended for use with Santovac 5 ASA pump versions include o-rings for both inlet and foreline flanges ISO pump versions include inlet flange o-ring, but does not include foreline flange centering ring Baffles can be found on pages 93 and 94 Ordering Information Description Wt. kg (lbs) Part Number Replacement Parts (six heaters required per pump) Heater, 4 W, 24 V/415 V/.5 (1.) 6473321 48 V with leads Heater, 4 W, 24 V/415 V/.5 (1.) 64733275 48 V no leads used on pumps built before May 199 Heater, 4 W, 2 V.5 (1.) 6473352 Heater, 4 W, 4 V.5 (1.) L63831 Heater, 4 W, 44 V.5 (1.) L638311 Heater crush plate (replace one with.5 (1.) K72461 each new heater) Heater insulator (one required.5 (1.) 757921 per pump) Heater clamping plate (six required 4 (8) K72471 per pump) Replacement o-ring kit for ASA pumps,.5 (1.) K377167 1 inlet flange o-ring, (buna, 45391)/ 1 foreline flange o-ring, (butyl, 2-443)/ 8 fill and drain o-rings, (Viton, 2-213) ISO inlet flange o-ring.5 (1.) 785362 Lower thermal switch.5 (1.) K954 (set at 55 F/288 C) Heater Retrofit Kit (for pumps built before May 199) HS-32, 24 18.16 (4.) L651738 HS-32, 415 18.16 (4.) L6517326 HS-32, 48 18.16 (4.) L651739 Please note that this item is controlled for export by the Nuclear Suppliers Group. Accordingly, you may be required to obtain an export license from the U.S. Department of Commerce prior to exporting this diffusion pump from the United States. Please consult the U.S. Export Administration Regulations, ECCN 2B231, for further guidance. Varian, Inc. Vacuum Technologies 87

NHS-35 Outline Drawing 42.25 (173) 31.81 (88) 72.13 (1832) Dimensions: inches (millimeters) Speed Curve 35 7 3 6 Air speed (l/sec) 25 2 15 1 5 4 3 2 Throughput (Torr-l/sec) 5 1-8 1 1-7 1-6 1-5 1-4 1-3 1-2 1-1 Inlet pressure (Torr) Pumping speed/cold cap Pumping speed/halo baffle Throughput Technical Specifications Pumping Speed*, Operating Range 28, l/s air, 35, l/s He and H 2 Maximum Throughput 25 T-l/s (33 mbar l/s) in operating range, 35 T-l/s (45 mbar-l/s) @.1 torr Operating Range 9 x 1-4 to < 5 x 1-8 torr (1.2 x 1-3 < 6.5 x 1-8 mbar) Maximum Forepressure No Load.55 torr (.71 mbar), Full Load.4 torr (.52 mbar) Recommended Backing Pump 3 cfm (51 m 3 /hr) Backstreaming Rate*, Standard Cold Cap <5 x 1-4 mg/cm 2 /min Warmup Time 6 minutes Cooldown Time 18 minutes Fluid Charge 3 U.S. gallons (11.3 liters) Electrical Requirements 3 ph, 5/6 Hz, 24/415/48 VAC Pump Power 24, watts Cooling Water Requirements 4 gpm (8 l/hr) at 6-8 F (15-26 C) Recommended Fluid DC-74 (see page 9) 88

Diffusion Pumps Ordering Information Description Voltage Weight kg (lbs) Part Number Flange Type HS-35 Pump ASA ISO NHS-35 with standard cold cap 24 V 68. (1,55.) F17338 L592438 NHS-35 with halo baffle 24 V 68. (1,55.) F173318 L5924318 NHS-35 with standard cold cap 415 V 68. (1,55.) F173326 L5924326 NHS-35 with halo baffle 415 V 68. (1,55.) F173336 L5924336 NHS-35 with standard cold cap 48 V 68. (1,55.) F17339 L592439 NHS-35 with halo baffle 48 V 68. (1,55.) F173319 L5924319 Accessories Page Weight kg (lbs) Part Number Water-cooled halo baffle 94 2. (45.) K1857335 Water-cooled baffle with ASA flanges 93 225. (495.) R115831 Water-cooled baffle with ISO flanges 93 17. (375.) R115931 Quick cool coil must be installed in the factory, can not ship separately F17391 Centering ring for ISO foreline flange, 2K.5 (1.) IC2SV O-ring, ISO Inlet flange.5 (1.) 785362 Instruction manual 6999114 Replacement Parts (six heaters required per pump) Heater 4 W, 24 V/48 V with leads.5 (1.) 6473351 Heater 4 W, 24 V/48 V no leads used on pumps built before May 199.5 (1.) 647235248 Heat shield (reusable).5 (1.) L6371 Heater clamping plate (six required per pump) 4. (8.) F17491 Heater insulator (one required per pump).5 (1.) L96991 Replacement o-ring kit for ASA pumps 1 inlet flange o-ring, (buna, 785361)/ 1 foreline flange o-ring, (butyl, 2-267)/8 fill and drain o-rings, (Viton, 2-213).5 (1.) K377169 Sightglass service kit (pumps built before Oct 95) 1.5 (3.) F69731 Upper thermal switch (set at 2 F/93 C).5 (1.) K955 Lower thermal switch (set at 6 F/316 C).5 (1.) K956 Heater Retrofit Kit (for pumps built before May 199) NHS-35, 24/4/44 18.16 (4.) L639138 NHS-35, 415 18.16 (4.) L6391326 NHS-35, 48 18.16 (4.) L639139 NOTE Inlet flange 35 in. ASA, foreline flange 6 in. ASA Inlet flange ISO 1F (bolted), foreline flange ISO 2K (clamped) Not recommended for use with Santovac 5 ASA pump versions include o-rings for both inlet and foreline flanges ISO pump versions include inlet flange o-ring, but does not include foreline flange centering ring Diffusion Pumps Please note that this item is controlled for export by the Nuclear Suppliers Group. Accordingly, you may be required to obtain an export license from the U.S. Department of Commerce prior to exporting this diffusion pump from the United States. Please consult the U.S. Export Administration Regulations, ECCN 2B231, for further guidance. Varian, Inc. Vacuum Technologies 89

Diffusion Pump Fluids Varian offers a wide range of diffusion pump fluid types and containers sizes. We have just the right fluid type and container size to meet the requirements of your particular application. Varian now offers exact pump charges for many of our diffusion pumps, including the VHS-6, VHS-1, HS-16, HS-2, HS-32, and NHS-35. Exact pump charges enable you to purchase just enough fluid to fill your diffusion pump, thus eliminating costly waste. This eliminates problems associated with the disposal of diffusion pump fluid and eliminates the guess work associated with filling the pump. NEOVAC SY DC-72 DC-74 DC-75 SANTOVAC 5* Chemical description Synthetic Silicone Single-Component High-Purity Mixed 5-Ring Hydrocarbon Silicone Silicone Polyphenyl Ether Chemical composition Mono-N Mixed Tetramethyltetra- Penta phenyltri- Mixed 5-Ring Alkyldiphenylether Phenylmethyldimethyl phenyltrisiloxane methyltrisiloxane Polyphenyl Ether Cyclosiloxane Ultimate pressure Untrapped (torr) Low 1-8 Range 1-6 1-7 to 1-8 range 1-9 to 1-1 range 1-1 Trapped (torr) 1 x 1-11 Range to 1-11 range 1-11 range Vapor pressure at 25 C (torr) 1 x 1-8 1 x 1-6 2 x 1-8 3 x 1-1 1 x 1-9 at 2 C Viscosity (cst) at 25 C 25 at 4 C 45 39 175 24 Average molecular weight 45 484 546 446 Boiling temperature ( C) at.5 torr 22 at.8 torr 18 215 245 275 Flash point 23 193 221 243 288 Ultimate pressure Very Good Fair Very Good Excellent Excellent Thermal stability Good Excellent Excellent Excellent Very Good Oxidation resistance Good Excellent Excellent Excellent Very Good System cleanliness Very Good Good Very Good Very Good Excellent NOTE Santovac 5 is the only recommended fluid for leak detectors NEOVAC SY is a high quality, low cost synthetic organic compound (alkyldiphenylether) that performs as well as DC-74. With its low vapor pressure, it will achieve base pressures in the low 1-8 torr range untrapped and will not produce inorganic deposits which can cause electrostatic charge buildup on electrodes of sensitive instruments. Dow Corning DC-72 is an all-purpose silicone fluid that is capable of achieving pressures of 1-7 torr range. With lower boiling points than DC 74 and DC 75, it gives higher throughput for a given power. Dow Corning DC-74 is a single component silicone fluid that will achieve pressures in the low 1-8 torr range untrapped. With its low vapor pressure, it combines very good pumping characteristics with low Backstreaming Rates. Dow Corning DC-75 is a high-purity, single component silicone fluid designed for ultrahigh vacuum applications. It can achieve pressures in the low 1-1 torr range untrapped. The vapor pressure and backstreaming rate of this fluid is so low that the use of traps and baffles is often unnecessary. Santovac 5 is a five-ring polyphenylether for use in ultrahigh vacuum applications. With ultra low vapor pressure and backstreaming rates, this fluid is very clean and often eliminates the need for traps and baffles. Ultimate pressures in the 1-1 torr range can be achieved and will not produce inorganic deposits which can cause electrostatic charge buildup on electrodes of sensitive instruments. 9

Diffusion Pumps Ordering Information Description Diffusion Pump Weight kg (lbs) Part Number Exact Charge NEOVAC SY 1 liter/1, cc VHS-1, VHS-4 3. (1.4) K694831 U.S. gallon (3.8 liters) 1.6 (4.8) K694835 5 U.S. gallons (18.9 liters) 53. (23.9) K6948315 Dow Corning DC-72 5 cc VHS-6, VHS-25 3. (1.4) 6954725 1 U.S. gallon (3.8 liters) 12. (5.4) 6954728 5 U.S. gallons (18.9 liters) 51. (23.) 69547215 Dow Corning DC-74 5 cc VHS-6, VHS-25 3. (1.4) 6954745 1 U.S. gallon (3.8 liters) 12. (5.4) 6954748 6.2 U.S. gallons (23.5 liters) 51. (23.) 69547415 Dow Corning DC-75 5 cc VHS-6, VHS-25 3. (1.4) 6954755 1 U.S. gallon (3.8 liters) 12. (5.4) 6954758 Santovac 5 4 cc 1. (.5) 695451 65 cc 2. (.9) 695452 5 cc VHS-6, VHS-25 2.5 (1.1) 695455 Diffusion Pumps Varian, Inc. Vacuum Technologies 91

Water-Cooled Baffles Outline Drawing Dimensions: inches Technical Specifications Ordering Information 33 Water-Cooled Nominal Conductance Recommended Flow 334 Water-Cooled Nominal Conductance Recommended Flow 332 Water-Cooled Nominal Conductance Recommended Flow 336 Water-Cooled Nominal Conductance Recommended Flow 3,55 l/s (air).1 to.2 gpm (2-4 l/hr) 9 l/s (air).1 to.2 gpm (2-4 l/hr) 3 l/s (air).1 to.2 gpm (2-4 l/hr) 1,5 l/s (air).1 to.2 gpm (2-4 l/hr) Description Weight Part kg (lbs) Number Low-profile 33 Water-cooled baffle ASA 9. (2.) F8631 Low-profile 33 Water-cooled baffle ISO 9. (2.) F86311 Low-profile 33 Water-cooled baffle CFF 9. (2.) F86312 334 Water-Cooled Baffle ASA 4.5 (1.) F828634 334 Water-Cooled Baffle ISO 4.5 (1.) F828635 334 Water-Cooled Baffle CFF 4.5 (1.) F828636 332 Water-cooled baffle ASA 4.5 (1.) F945332 332 Water-cooled baffle ISO 4.5 (1.) F945333 332 Water-cooled baffle CFF 4.5 (1.) F945334 336 Water-cooled baffle ASA 7. (15.) F827736 336 Water-cooled baffle ISO 7. (15.) F827737 336 Water-cooled baffle CFF 7. (15.) F827738 92

Water-Cooled Baffles for HS-16, HS-2, HS-32, and NHS Diffusion Pumps Diffusion Pumps Diffusion Pumps Technical Specifications Recommended Cooling-water Flow Rate Supportable Weight 1-2 gpm (227-554 liter/hr) Designed to support weight of corresponding diffusion pump Flange Dimensions Baffle Diffusion Inlet & Outlet Flange Hole Size Flange Flange Outside Cooling Water Part Number Pump Model Flanges Bolt Circle Height Diameter Tubing OD R115231 HS-16 16 in. ASA 54 (21.25) 29 (1.125) 18 (7.9) 597 (23.5) 15 (.59) R115331 HS-16 ISO-5K Clamped flanges without bolts 18 (7.9) 55 (21.65) 15 (.59) R115431 HS-2 2 in. ASA 635 (25.) 32 (1.25) 18 (7.9) 699 (27.5) 15 (.59) R115531 HS-2 ISO-63K Clamped flanges without bolts 18 (7.9) 69 (27.17) 15 (.59) R115631 HS-32 32 in. ASA 921 (36.25) 22 (.875) 18 (7.9) 968 (38.12) 15 (.59) R115731 HS-32 ISO-8F 89 (35.4) 14 (.55) 18 (7.9) 92 (36.22) 15 (.59) R115831 NHS-35 35 in. ASA 978 (38.5) 22 (.875) 18 (7.9) 16 (41.75) 15 (.59) R115931 NHS-35 ISO-1F 19 (42.91) 14 (.55) 18 (7.9) 112 (44.9) 15 (.59) Ordering Information Description Weight kg (lbs) Part Number Water-cooled baffle for HS-16 with ASA flanges 8 (18) R115231 Water-cooled baffle for HS-16 with ISO flanges 6 (13) R115331 Water-cooled baffle for HS-2 with ASA flanges 1 (215) R115431 Water-cooled baffle for HS-2 with ISO flanges 7 (16) R115531 Water-cooled baffle for HS-32 with ASA flanges 16 (35) R115631 Water-cooled baffle for HS-32 with ISO flanges 135 (3) R115731 Water-cooled baffle for NHS-35 with ASA flanges 225 (495) R115831 Water-cooled baffle for NHS-35 with ISO flanges 17 (375) R115931 Varian, Inc. Vacuum Technologies 93

Halo Baffles for Large Diffusion Pumps for HS-16, -2, and NHS-35 Diffusion Pumps Varian s Halo Baffles provide nearly twice the speed at the pump inlet as that achieved with conventional chevron baffles, while adding no height to the system. These watercooled baffles are very economical compared to other opaque chevron baffles. Net Speed with Halo Baffle Approximately 6% of pump speed* Backstreaming Reduction Approximately 9%* Materials Nickel-plated copper (16 in., 2 in.) Nickel-plated mild steel (32 in., 35 in.) Cooling: Recommended Water Flow Technical Specifications In series with diffusion pumps. See specific diffusion pump technical specs HS16 HS-35. Ordering Information Baffle Size Weight Part kg (lbs) Number 16 in. 9. (2.) K143316 2 in. 11. (25.) K185532 32 in. 16. (35.) K1856332 35 in. 2. (45.) K1857335 * Values are estimates. Actual speed and backstreaming rate will vary depending on the application conditions. 94

Extended Cold Caps for VHS-4, -6, and -1 Diffusion Pumps Diffusion Pumps The Extended Cold Cap is an option that fits inside the VHS-4, VHS-6, and VHS-1 pumps in place of the standard cold cap. It stops backstreaming as effectively as an optically dense baffle, yet it retains 8% of the pump s speed. Residual backstreaming is so low that it cannot be measured by the American Vacuum Society s standard collection method. Diffusion Pumps Technical Specifications Ordering Information Speed with Extended Cold Cap Materials Cooling 8% of pump speed Nickel-plated copper Conduction (no water) Description Weight Part kg (lbs) Number VHS-4.5 (1.) F689831 VHS-6.5 (1.) F64551 VHS-1.9 (2.) L891731 Varian, Inc. Vacuum Technologies 95