Catalog Number. Notes

Similar documents
Catalog Number. Notes

Catalog Number. Notes

Catalog Number. Notes. Type ADP. Series Air function Lumens Diffuser Voltage Driver Color temperature. Acrylic linear prismatic

LOW PROFILE 4 APERTURE UP TO 4800 LUMENS DELIVERED LLP4/LLPRM4 SERIES

800 TO 9000 LUMEN 10 LED RETRO-FIT HYPERBOLIC / PARABOLIC LRT10 SERIES

CERRA 10 LED Design2Ship

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

IECC. nlight Applications Guide.

Oh, Lic# SHOP DRAWINGS Lake Erie Electric, Inc. FOR DWG.& SPEC. CONFORMITY ONLY D.M.Y 08/15/2016

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

800 TO 9000 LUMEN 6 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT6 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

800 TO 8000 LUMEN 4 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L4 / LRM4 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

800 TO 9000 LUMEN 8 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L8 / LRM8 SERIES

800 TO 9000 LUMEN 6 LED NEW CONSTRUCTION/REMODEL/FLANGELESS HYPERBOLIC / PARABOLIC / WALLWASH L6 / LRM6 SERIES

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

BAS SDL8' LED Strip Diffused Lens

800 TO 5500 LUMEN 6 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC6 SERIES

SDL4 LED Strip Diffused Lens

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

VESICA LINEAR SUSPENDED VES L

800 TO 2800 LUMEN 4 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC4 SERIES

800 TO 5500 LUMEN 8 LED CYLINDER HYPERBOLIC / PARABOLIC / WALLWASH / OPEN APERTURE LC8 SERIES

BAS SFP22 Edge-lit LED Panel

Series / Housing Style Lumens CCT CRI Beam Driver Voltage 2 Options. 80CRI 15D 15 beam 35D 35 beam 45D 45 beam

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Dimensions (111mm) (111mm) 3 (76mm)

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

Catalog Number. Notes

Luminaire Type: Catalog Number: Slot Trim (SLT) MYO Configurable 1, 2 & 3-Head Recessed Multiple Series

Catalog Number. Notes

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Catalog # Project. Comments. Prepared by. 23-3/4" [603mm] LAMP CONFIGURATIONS. 3-1/4" [83mm] X=2-7/16" [62mm] Y=2-1/2" [64mm] CEILING COMPATIBILITY

Max 4 Flush Lens RECESSED

9533, 9534, 9535, 9537 Shower Curtain Model 9535 & 9537 Antimicrobial Shower Curtain

Grüv Flare Regressed. Recessed Linear LED

RECESSED T-Bar & Drywall

Alliance 4 - ALI4 LED 4 Linear High Bay

Grüv Flare Regressed. Recessed Linear LED

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

LHBXD LED Linear High Bay

Lighting Control Strategies. to meet code requirements save energy and improve building performance

lumenalpha downlight Specification Sheet

DIMMING 0-10V Continuous

LIGHTING WITHOUT LIMITS. Manufacturers of LED and Fluorescent Luminaires

PROJECT DATE FLANGE FINISH

RECESSED Spec Guide. up to 111 lm/w performance

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Project Name. Date. Cat. Number. Type

Catalog Number. Notes. Type

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Addendum # 1 to Bid MEB Audiovisual Faculty Training Center Renovation

RLN Recessed LED luminaire

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

Hornet HP. Semi-Recessed 4-Light Square Multiple

Velato. Recessed Slot Adjustable Multiples

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

FULL BLEED APPLICATION SHOT RENDERING

Highbay Linear LED Series Flat Profile Design

Etch 2' x 2' Recessed LED

Lumination LED Luminaires

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

ArcLine Recessed LED luminaire

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

IHOL-6DR / IRD600 6 Gravity LED Downlight

DHL-LP-LED Low Profile LED Linear High/Low Bay

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

RECESSED - WITH StepLens OPTION

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

FPLHB - Fidelux Premier Linear Highbay

Evoke Square Downlight

Recessed LED Wall/Slot SAE 202

SURFACE Spec Guide. up to 105 lm/w performance

RTC Recessed LED center basket

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Truss Surface SURFACE

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Hornet HP. Round Glass Downlight

North Hanover Township School District North Hanover Township, New Jersey

Evolve LED Garage Light

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

IHOL-4DR / IRD400 4 Gravity LED Downlight

Empowering Your Vision

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

led HIGH CEILING 3 OUTPUT LEVELS LL1 - Low Output: 49W LL2 - Medium Output: 69W LL3 - High Output: 100W

ARCHWAY TM PASSAGE TM

Claude Indirect Wall WALL

Hornet HP. Square Glass Downlight

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

Mini Product Guide.

Transcription:

Catalog Number FEATURES & SPECIFICATIONS INTENDED USE The BLT Best-in-Value Low Profile LED luminaire features a popular center basket design that offers a clean, versatile style and volumetric distribution. High efficacy LED light engines deliver energy savings and low maintenance compared to traditional sources. An extensive selection of configurations and options make the BLT the perfect choice for many lighting applications including schools, offices and other commercial spaces, retail, hospitals and healthcare facilities. The low profile BLT design (2-3/4") also makes it an excellent choice for renovation projects. CONSTRUCTION BLT enclosure components are die-formed for dimensional consistency and painted after fabrication with a polyester powder paint for improved performance and protection. The reflector is finished with a high reflective matte white powder paint for improved aesthetics and increased light diffusion. End plates contain easy-to-position integral T-bar clips for securely attaching the luminaire to the T-grid. For additional T-grid security, optional screw on T-bar clips are available. Diffusers are extruded from impact modified acrylic for increased durability. Injection molded diffuser light traps add a finished look to the diffuser ends and help seal the diffuser to the housing end plates. Optional diffuser trim rings provide an attractive mounting for integral sensors as well as adding a decorative element to the luminaire aesthetics. LED boards are accessible from below; driver is accessible from the plenum. OPTICS Volumetric illumination is achieved by creating an optimal mix of light to walls, partitions and vertical and horizontal work surfaces rendering the interior space, objects and occupants in a more balanced, complimentary luminous environment. High performance extruded acrylic diffusers conceal LEDs and efficiently deliver light in a volumetric distribution. Four diffuser choices available - curved and square designs with linear prisms or a smooth frosted finish. ELECTRICAL Long-life LEDs, coupled with high-efficiency drivers, provide superior quantity and quality of illumination for extended service life. 80% LED lumen maintenance at 60,000 hours (L80/60,000). Color Variation within 3-step MacAdam ellipse (3SDCM). eldoled driver options deliver choice of dimming range, and choices for control, while assuring flicker-free, low-current inrush, 89% efficiency and low EMI. Optional integrated nlight controls make each luminaire addressable - allowing it to digitally communicate with other nlight enabled controls such as dimmers, switches, occupancy sensors and photocontrols. Simply connect all the nlight enabled control devices and the BLT luminaires using standard Cat-5 cabling. Unique plug-and-play convenience as devices and luminaires automatically discover each other and self-commission. Lumen Management: Unique lumen management system (option N80) provides on board intelligence that actively manages the LED light source so that constant lumen output is maintained over the system life, preventing the energy waste created by the traditional practice of over-lighting. Step-level dimming option allows system to be switched to 50% power for compliance with common energy codes while maintaining fixture appearance. Driver disconnect provided where required to comply with US and Canadian codes. SENSOR Integrated sensor (individual control): Sensor Switch MSD7ADCX ((Passive infrared (PIR)) or MSDPDT7ADCX ((PIR/Microphonics Dual Tech (PDT)) integrated occupancy sensor/automatic dimming photocell allows the luminaire to power off when the space is unoccupied or enough ambient light is entering the space. See page 2 for more details on the integrated sensor. Integrated Sensor (nlight Wired Networking): This sensor is nlight-enabled, meaning it has the ability to communicate over an nlight network. When wired, using CAT-5 cabling, with other nlight-enabled sensors, power packs, or WallPods, an nlight control zone is created. Once linked to a Gateway, directly or via a Bridge, the zone becomes capable of remote status monitoring and control via SensorView software. See page 2 for the nlight sensor options. INSTALLATION The BLT s low profile design of only 2-3/4" provides increased installation flexibility especially in restrictive plenum applications. The BLT fits into 15"/16" and narrow 9"/16" T-grid ceiling systems. Suitable for damp location. For recessed mounting in hard ceiling applications, Drywall Grid Adapters (DGA) are available as an accessory. See Accessories section. LISTINGS CSA Certified to meet U.S. and Canadian standards. IC rated. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/customerresources/terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C. Specifications subject to change without notice. Notes Type Specifications Length: 47.75 (121.29) Width: 19.75 (50.17) Depth: 2.75 (6.99) All dimensions are inches (centimeters) unless otherwise specified. Multiple Diffuser Options ADP Curved Ribbed SDP Square Ribbed Capable Luminaire BLT Series LED ADSM Curved Smooth SDSM Square Smooth This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning. All configurations of this luminaire meet the Acuity Brands specification for chromatic consistency This luminaire is part of an A+ Certified solution for nlight control networks when ordered with drivers marked by a shaded background* This luminaire is part of an A+ Certified solution for nlight control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control options marked by a shaded background* To learn more about A+, visit www.acuitybrands.com/aplus. *See ordering tree for details 20"x48" LED LED

Volumetric Recessed Lighting 20"x48" A+ Capable options indicated by this color background. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: 4 40L ADP EZ1 LP835 4 Series Lumens 1 Diffuser Voltage Driver Color temperature 4 BLT series 20"x48" 30L 3000 40L 4000 48L 4800 60L 6000 72L 7200 ADP Curved, linear prisms ADSM Curved, smooth SDP Square, linear prisms SDSM Square, smooth Diffusers w/ trim rings ADPT Curved, linear prisms ADSMT Curved, smooth SDPT Square, linear prisms SDSMT Square, smooth (blank) MVOLT 120 120V 277 277V 347 347V 2 EZ1 eldoled dims to 1% (0-10 volt dimming) GZ1 Dims to 1% (0-10V dimming) 3 GZ10 Dims to 10%( 0-10V dimming) 3 SLD Step-level dimming 4 LP830 LP835 LP840 LP850 LP930 LP935 LP940 LP950 82CRI, 3000 K 82CRI, 3500 K 82CRI, 4000 K 82CRI, 5000 K 90CRI, 3000K 90CRI, 3500K 90CRI, 4000K 90CRI, 5000K Controls Occupancy control 6 Options (blank) N80 N80EMG N100 N100EMG No nlight nlight with 80% lumen management nlight with 80% lumen management For use with generator supply EM power 5 nlight without lumen management nlight without lumen management For use with generator supply EM power 5 (blank) No sensor control nlight Wired Networking NES7 nlight nes 7 PIR integral occupancy sensor 7 NESPDT7 nlight nes PDT 7 dual technology integral occupancy control 7 NES7ADCX nlight nes 7 ADCX PIR integral occupancy sensor with automatic dimming photocell 7 NESPDT7ADCX nlight nes PDT 7 dual technology integral occupancy dimming photocell 7 Individual Control MSD7ADCX PIR integral occupancy dimming control photocell 4,8 MSDPDT7ADCX PDT integral occupancy dimming control photocell 4,8 EL7L 700 lumen battery pack 9 EL14L 1400 lumen battery pack 9 BGTD Bodine Generator Transfer Device 10 PWS1836 PWS1846 6 pre-wire, 3/8 diameter, 18 gauge, 1 circuit 6 pre-wire, 3/8 diameter, 18 gauge, 2 circuit PWS1846 PWSLV Two cables: one 6' pre-wire, 3/8 diameter, 18 gauge, 2 circuits; one 6' pre-wire, 3/8 diameter, 18 gauge, purple and gray 11 PWS1856LV 6 pre-wire, 3/8 diameter, 18 gauge, 1 circuit w/low voltage purple and grey wires 11 GLR Fast-blowing fuse 12 GMF Slow-blowing fuse 12 NPLT Narrow pallet RRL_ RELOC -ready luminaire 13 LATC DWAM CP Earthquake clip Anti-Microbial paint Chicago plenum Accessories next page Notes 1 Approximate lumen output. 2 Not available with SLD driver, EL7L or EL14L battery packs. 3 GZ1, GZ10 not available with Controls or Sensor options. 4 Not available with N80, N80EMG, N100, N100EMG or occupancy control. 5 nlight EMG option requires a connection to existing nlight network. Power is provided from a separate N80 or N100 enabled fixture. 6 Must specify diffuser with trims rings. See sensor options on page 3. 7 Requires N80, N80EMG, N100, or N100EMG. 8 Only available with EZ1 driver option. 0-10v dimming wires not accessible via access plate. 9 When using pre-wire option, use PWS1846 or PWS1846 PWSLV. 10 Must specify voltage. Requires BSE labeling. Consult factory for options. 11 Not available with nlight wired network or individual controls. 12 Must specify voltage, 120 or 277 with GLR & GMF fusing. 13 For ordering logic consult: RRL_2013.

Volumetric Recessed Lighting 20"x48" Accessories: Order as separate catalog number. DGA204 Drywall grid adapter for 20"x 48" recessed fixture nlight Control Accessories: Order as separate catalog number. Visit www.acuitybrands.com/products/controls/nlight. WallPod stations Model number Occupancy sensors Model number On/Off npodm [color] Small motion 360, ceiling (PIR / dual tech) ncm 9 RJB / ncm PDT 9 RJB On/Off & raise/lower npodm DX [color] Large motion 360, ceiling (PIR / dual tech) ncm10 RJB / ncm PDT 10 RJB Graphic touchscreen npod GFX [color] Wall switch with raise/lower nwsx PDT LV DX [color] Photocell controls Model number Cat-5 cable (plenum rated) Model number Full range dimming ncm ADCX RJB 10' cable CAT5 10FT J1 30' cable CAT5 30FT J1 Replacement Parts: Order as separate catalog number. *237LKE DBLT48 ADP LENS ASSEMBLY 4 ft. replacement lens (light traps included) *237LKL DBLT48 SDP LENS ASSEMBLY 4 ft. replacement lens (light traps included) *237LL2 DBLT48 ADSM LENS ASSEMBLY 4 ft. replacement lens (light traps included) *237LLA DBLT48 SDSM LENS ASSEMBLY 4 ft. replacement lens (light traps included) *237LT2 DBLT48 ADPT LENS ASSEMBLY 4 ft. replacement lens (trims included) *237LT4 DBLT48 SDPT LENS ASSEMBLY 4 ft. replacement lens (trims included) *237LT6 DBLT48 ADSMT LENS ASSEMBLY 4 ft. replacement lens (trims included) *237LT8 DBLT48 SDSMT LENS ASSEMBLY 4 ft. replacement lens (trims included) *237LTA DBLT48 ADPT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) *237M52 DBLT48 SDPT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) *237M5A DBLT48 ADSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included) *237M5L DBLT48 SDSMT SENSOR LENS ASSEMBLY 4 ft. replacement lens (trims included)

Volumetric Recessed Lighting 20"x48" Option Automatic Dimming Photocell Sensor Options Occupancy Sensing PIR PDT nlight Wired Networking MSD7ADCX X X MSDPDT7ADCX X X NES7 X X NES7ADCX X X X NESPDT7 X X NESPDT7ADCX X X X Basic nlight Zone Integrated Sensor with Individual Control The MSD7ADCX PIR occupancy sensor/automatic dimming photocell is ideal for areas without obstructions and where daylight harvesting may be desired. Suggested applications include, but not limited to, hallways, corridors, storage rooms, and breakrooms or other areas where people are typically moving. The MSDPDT7ADCX PIR/Microphonics Dual Tech occupancy sensor/automatic dimming photocell is ideal for areas with obstructions and where daylight harvesting is desired. Suggested applications include, but not limited to, open offices, private offices, classrooms, public restrooms, and conference rooms. Sequence of Operation nlight Wired Networking The nes 7 is ideal for small rooms without obstructions or areas with primarily walking motion. Ideal areas include hallways, corridors, storage rooms, and breakrooms. Additionally, the NES7ADCX includes an integrated photocell, which enables daylight harvesting controls. For areas like restrooms, private offices, open offices, conference rooms or any space with obstructions, the nes PDT 7 dual technology sensor is recommended. The nes PDT 7 utilizes both PIR (passive infrared) and Microphonics technologies to detect occupancy. Additionally, the NESPDT7ADCX includes an integrated photocell, which enables daylight harvesting controls which is ideal for areas where windows are present. Sequence of Operation MAX MOTION NO MOTION MOTION MAX MOTION NO MOTION MOTION LIGHT LEVEL Occupants Detected In The Space Room Unoccupied Sensor Detects Motion LIGHT LEVEL Occupants Detected In The Space Room Unoccupied Sensor Detects Motion MIN 17.5 MIN TIME DELAY 2.5 MIN AT A 1% LEVEL LIGHTS OFF MIN 7.5 MIN TIME DELAY 2.5 MIN AT A 1% LEVEL LIGHTS OFF *The presetting on the automatic dimming photocell is 5fc. *The presetting on the automatic dimming photocell is 5fc. Sensor Coverage Pattern Mini 360 Lens Recommended for walking motion detection from mounting heights between 8 ft (2.44 m) and 20 ft (6.10 m) Initial detection of walking motion along sensor axes at distances of 2x the mounting height up to 15 ft (4.57 m) and 1.75x up to 20 ft (6.10 m). Provides 12 ft (3.66 m) radial detection of small motion when mounted at 9 ft (2.74 m) Initial detection will occur earlier when walking across sensor s field of view than when walking directly at sensor 9 FT Mounting 5.5 18 4.6 15 3.7 12 2.7 9 1.8 6 0.9 3 0 m 0 ft 0.9 3 1.8 6 2.7 9 3.7 12 4.6 15 5.5 18

Volumetric Recessed Lighting 20"x48" PHOTOMETRICS 4 40L ADP LP835, 3795 delivered lumens, test no. ISF30109P5, tested in accordance to IESNA LM-79 4 48L ADP LP835, 4926 delivered lumens, test no. ISF30109P9, tested in accordance to IESNA LM-79 Constant Lumen Management Enabled by the embedded nlight control, the BLT actively tracks its run-time and manages its light source such that constant lumen output is maintained over the system life. Referred to as lumen management, this feature eliminates the energy waste created by the traditional practice of over-lighting. Without Lumen Management Energy is wasted and light level is inconsistent. 100% 34W MOUNTING DATA Ceiling Type Exposed grid tee (1 and 9/16 ) G Concealed grid tee Plaster or plasterboard G* Appropriate Trim Type G 9/16 15/16 Screw Slot *DGA accessory available to provide ceiling trim flange and fixture support for plaster or plasterboard ceiling. Recommended rough-in dimensions for DGA installation is 20-3/4" x 48-3/4" (Tolerance is +1/8", -0 ). 80% Wasted Energy LIGHT OUTPUT 0 10 20 30 40 50 THOUSAND OPERATING HOURS With Lumen Management Energy is saved and light level remains consistent. 100% 80% Saved Energy POWER INPUT 0 10 20 30 40 50 THOUSAND OPERATING HOURS 27W 34W 27W Performance Data Lumen Package Lumens Input Watts LPW 30L ADP LP830 3178 30 106 30L ADP LP835 3243 30 108 30L ADP LP840 3331 30 111 30L ADP LP850 3359 30 112 40L ADP LP830 3720 34 109 40L ADP LP835 3795 34 111 40L ADP LP840 3898 34 114 40L ADP LP850 3952 34 116 48L ADP LP830 4828 45 107 48L ADP LP835 4927 45 110 48L ADP LP840 5060 45 112 48L ADP LP850 5104 45 113 60L ADP LP830 5816 53 110 60L ADP LP835 5935 53 112 60L ADP LP840 6096 53 115 60L ADP LP850 6148 53 116 72L ADP LP830 7145 67 106 72L ADP LP835 7291 67 108 72L ADP LP840 7489 67 111 72L ADP LP850 7553 67 112