Specifications Wavelength Range: 190 nm to 800 nm continuous

Similar documents
detectors UltiMate 3000 Variable Wavelength Detectors

Nexera-i Specifications Prominence-i Specifications

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Agilent 1200 Series Variable Wavelength Detector

OMA-300 Process Analyzer

APPLIED. OMA-406R Rackmount Process Analyzer

Agilent 1100 Series Variable Wavelength Detector. Reference Manual

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

Agilent 1200 Series Diode Array and Multiple Wavelength Detectors

An FT-NIR Primer. NR800-A-006

APPLIED. OMA-206P Portable Process Analyzer. A window into your process since 1994.

Nicolet Evolution 300. UV-Visible Spectrophotometer

Technical Information OUSAF44

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Vanquish. Variable Wavelength Detectors VF-D40. Operating Manual

Who is GBC Scientific Equipment?

WASTEWATER Online UV%Transmission Analyzer

SPECTRAL INSTRUMENTATION

Technical Information OUSAF21

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Technical Information OUSBT66

Common Features of DX-600 Modules

LABTRON LAAS - Series Atomic Absorption Spectrophotometer

Technical Information OUSAF22

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Infrared Moisture Balance (FD-660)

Mercury Vapor Monitor VM-3000

2998 Photodiode Array Detector Operator s Guide

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

VM-3000 Mercury Vapor Monitor

Model 1062 Environment Monitor

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

VM-3000 Mercury Vapor Monitor

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

Technical Information OUSBT66

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

for Drinking Water Systems

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

SP-3800AA Atomic Absorption Spectrophotometer

Air Resource Specialists, Inc.

ACQUITY UPC 2 Photodiode Array Detector Overview and Maintenance Guide

Features and Benefits

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Affordable Lab Technology

PUV, PIR and PFO Series BROCHURE

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011

OFS IV Optical Fibre System

Chemistry Instrumental Analysis Lecture 4. Chem 4631

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Understanding total measurement uncertainty in power meters and detectors

Technical Information OUSAF12

Features and Benefits

NanoReady. Micro UV-Vis Spectrophotometer

Equipment specifications (D6)

CALIDUS tm the Modular micro Gas Chromatograph

Waters 996 PDA Detector

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

The Viva-ProE System

WHAT IS LASER ULTRASONIC TESTING?

SmartClass and SmartPocket Optical Handhelds. Portfolio of Optical Handhelds for Fiber Field Test

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

Agilent 1100 Series Diode Array and Multiple Wavelength Detectors. Reference Manual

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Infrared Moisture Balance (FD-800)

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Optilab T-rEX. Differential Refractometer with Extended Range. 256 Times the Detection Power 50 Times the Dynamic Range

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

Fast. Precise. Versatile. UL Lighting Sciences

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

Speed and Frequency Seite 1 von 7

Spectrum Detector, Inc.

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

Key Features. General Description

Technical specifications of FT-IR Spectrometer

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Turbimax CUE21 / CUE22

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

OVEN INDUSTRIES, INC.

300/400 UNITS - MODULAR CONFIGURATION

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Flame Simulator User Manual. Publication Rev. A

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

ProStar 325 UV-Vis Detector

Meets all design requirements of U.S.EPA. Double pass optical system for accuracy and sensitivity. Modulated light beam to eliminate interference

Innovative Technology for Traditional and Challenging Applications

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

ACCURATE ELECTRONICS INC

Transmission Photometer UV / VIS / NIR / IR. Reflection Photometer VIS / NIR / IR

Cone Calorimeter. (ISO 5660 ASTM E 1354) The most comprehensive bench scale fire test THE BENCHMARK IN FIRE TESTING

Product data sheet Palas Fidas 200 S

The design of the human body infrared thermometer

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Certified, Refurbished Lab Equipment Thermo Finnigan Surveyor PDA Detector Specifications Wavelength Range: 190 nm to 800 nm continuous Wavelength Accuracy: ±1 nm at 254 nm and 656 nm Digital Wavelength Resolution: 1.2 nm Absorbance Range: í2.0 AU to +4.0 AU, 20-bit resolution Short Term Noise* : 6 AU/cm at 254 nm for the 50 mm LightPipe According to ASTM E1657-94 Standard Practice for Testing Variable-Wavelength Photometric Detectors Used in Liquid Chromatography (for 50-mm flow cell, 5-nm bandwidth, 2-sec rise time, and MeOH at 1 ml/min.). Drift : 1 mau/h after warm up at 254 nm at a stable temperature (±1 ºC) Warm-up: 90 min to meet noise and drift specifications Linearity: deviation 5% up to 2.0 AU at 256 nm Scan Rate: 0.5, 1, 2, 4, 5, 10, or 20 Hz (user selectable) Rise Time: 0.0, 0.1, 0.2,0.5, 1, 2, 5, or 10 s (user selectable) Cell Dimensions: PP /_/LJKW3LSH

Cell Pressure Rating: 1000 psi Diodes: 512 Diode Spacing: 1.2 nm Light Source: Deuterium and tungsten-halogen lamps, pre-aligned Filter Wheels: Standard Filter Wheel: 2 position wheel, 1 open position and 1 Holmium oxide/perchloric acid filled cuvette, NIST traceable Optional Linearity Calibration Wheel: 5 position wheel, 1 with perchloric acid blank and 4 cuvettes with different concentrations of potassium dichromate in perchloric acid, NIST traceable Analog Outputs (2): 20-bit digital / analog conversion, unattenuated at 10 mv/au, 100 mv/au, or 1.0 V/AU Remote Controls: Start, Zero, RJ45 Ethernet interface for ChromQuest Dimensions: 18 cm (7.1 in.) 36 cm (14.2 in.) 47 cm (18.5 in.) (h w d) Weight: 19.5 kg (43 lbs) Power Requirements: 100/115 or 230 V ac; 50/60 Hz, 200 VA max. Operating Temperature: +10 to +30 ºC Storage Temperature: í WR ºC Operating Humidity: 5% to 95% non-condensing relative humidity Product Certification: CE, TUV-C/US, FCC (EMI)

Functional Description The Surveyor PDA Detector is a full-featured, time-programmable, photodiode array detector. Detection can be carried out in the full ultraviolet-visible range from 190 to 800 nm. Data can be taken in this range at a rate of up to 20 Hz with 20-bit digital conversion. The Surveyor PDA Detector is a bench-top unit for inclusion in the Surveyor liquid chromatography system. It is controlled remotely over an Ethernet communication link from a PC using ChromQuest or Xcalibur software. The detector consists of a dual-light source, an optical bench, a photodiode array, a low voltage power supply, several printed circuit boards (PCBs), and four status LEDs. Figure 1-2 shows the optical system used in the detector. The dual-light source includes a deuterium lamp for detection in the ultraviolet wavelength range (190 to 360 nm) and a tungsten-halogen lamp for detection in the visible wavelength range (360 to 800 nm). There is some overlap between the two lamps in the 300 to 500 nm range. Attenuators are used to adjust the intensity of light reaching the photodiode array. The optical bench contains a beam combiner, focusing lens, filter wheel, flow cell, beam shaper, folding mirror and grating. The beam combiner reflects the light coming from the tungsten-halogen lamp so that it is parallel to and coincident with the light from the deuterium lamp. The combined beam is then focused on the inlet window of the flow cell through the filter wheel. The standard filter wheel has two positions. Position 1 (Open) is used for normal operation. Position 2 contains a sealed, quartz cuvette filled with a holmium oxide / perchloric acid solution (NIST Traceable) for wavelength accuracy verification and calibration. Figure 1-2. The Surveyor PDA optical system

The light focused on the inlet window of the flow cell travels down the cell, is partially absorbed by the sample flowing through the cell, and exits into the beam shaper. The beam shaper is a fiber bundle. Its entrance aperture is circular to collect light from the flow cell. The other end of the bundle is arranged to produce a narrow slit of light for the grating. The beam shaper transfers all of the light to the grating for greater light throughput than the mechanical slit used in conventional photodiode array detectors. The folding mirror between the output of the beam shaper and the grating is used to shorten the optical bench and thus reduce the physical size of the detector. The spectrum from the grating is focused on the 512-element photodiode array (two of the diodes in this array are not used). Because the spectrum of light falling on the array is 611 nm (190 to 800 nm, inclusive), the effective spacing of the diodes is 611 nm / 510 = 1.2 nm. Firmware on the CPU PCB automatically interpolates diode intervals to arrive at integer wavelengths. The photodiode array is mounted on the Array Acquisition PCB, which also contains all of the analog detection circuitry. The diode array is continuously scanned at a 20-Hz rate, the light intensity at each diode is converted into a 20-bit digital word, and these words are stored in a dualport Random Access Memory (RAM) on the CPU PCB. As the data points are stored through one RAM port, the CPU reads the data it needs (based on user parameters entered through the software) through the other RAM port, processes the data, and sends it to the computer. The CPU PCB also processes remote inputs and outputs through the Converter PCB, which functions as an input / output panel. A dual, 20-bit digital-to-analog converter on the CPU PCB provides two, singlewavelength analog outputs on the rear connectors of the detector. The Converter PCB also has RS-232 and Ethernet communications connections, as well as unit identification settings. The detector also contains a lowvoltage power supply and a lamp power supply. Four status LEDs (light-emitting diodes) labeled Power Comm, Run, and Lamps are located on the right door of the detector. The Power LED illuminates green when the detector is switched on and receiving power. The Comm LED illuminates green when communication to the PC is established. It illuminates amber when there is no communication with the data system, and flashes amber when you download firmware to the CPU of the detector. The Run LED flashes green when a run is in progress. It illuminates amber when an error has occurred while performing a run. The Lamps LED illuminates amber when the lamps are off or when the D2 lamp is turning on (approximately 45 s). It illuminates green when

one or both lamps are on. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Certified, Refurbished Lab Equipment