ID2000. intelligent fire alarm panel

Similar documents
ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel

ID50series. intelligent fire alarm panels

intelligent fire alarm ID60series panels

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

ZXSe Range Data Sheet

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Components Brochure DX CONNEXION

Advanced FireAlarm Panel 1-4Loop

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

The EN54 Part 2 & 4 Fire System

SMALL SCALE SOLUTIONS

The EN54 Part 2, 4 and 13 Fire System

Extending Your Potential. Product Range

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Product Data Sheet. Remote Terminals. Features:

DCS-100. intelligent damper control & monitoring system

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings


INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Analogue Addressable Fire Panel Range

Intelligent Security & Fire Ltd

System 800 Addressable Fire Detection & Alarm System

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

NETWORKING AND INTEGRATION

INTELLIGENT FIRE ALARM CONTROL PANEL

HART XL High Sensitivity Smoke Detection

SUPREMATouch. Modular Fire & Gas Detection System

Intelligent Security & Fire Ltd

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Fire control panels FC360

Air Sampling Smoke Detection

For Complete Fire and Gas Solutions

Reliably Advanced Extinguishing Control

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Reliably Advanced Extinguishing Control

Control Panel User Guide (TO BE RETAINED BY THE USER)

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

HART XL High Sensitivity Smoke Detection

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Fire control panels FC726 FC726-XA

SUPREMATouch. Modular Fire & Gas Detection System

TABLE OF CONTENTS. 1. Intelligent Light 1.1 Intelligent Corridor Light 1.2 Intelligent Down Light

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Different types of Fire Alarm System

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

DRAFT 20 October 2014

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Honeywell Air Sampling Devices Data Sheet

DS7400Xi Addressable Control/ Communicator

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Input/Output Modules Data Sheet

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Consultant Specification AGILE Wireless Fire Detection System

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Vigilant MX4428 Fire Alarm System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Intelligent Single Loop Fire Alarm Control Panel

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Feature Summary. I. System

Fire control panel detect 3004 plus and accessories

ID2000. operating manual

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Intelligent 2 & 4 Loop Fire Alarm Control Panels

user manual Document No , Revision 03 November 2015

Fire detection and alarm system Operating instructions

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

FireClass. Introducing a new class of fire detection

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Product Overview Brochure. Flexibility to design a fire system that best suits you

ONYXWORKS AND FIRSTVISION. Version 4

Flair 500 Series Annunciators

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

Polycarbonate External Sounder & Strobe Unit

Integrated Security Solutions

TrueAlarm Fire Alarm Controls

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

EVCS EMERGENCY VOICE COMMUNICATION SYSTEMS

Laptop / PC Programming Manual

Engineer Paging. Staff Paging. Deaf Alert.

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

Addressable Fire Alarm Control System 2100 series

THX-DL Data Logger USER & INSTALLATION MANUAL V

Conventional & Twin-wire Fire System

U ser's Guide PC6010

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Why Hart XL Aspirating Smoke Detection?

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Transcription:

ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel

features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules) Up to 80 fire zones per panel Modular Design Supports advanced detection VIEW HARSH HAZARD OptiPlex 9 levels of sensitivity "Autolearn" Facility Network option Programmable from the panel keypad or PC 2 x 40 character back lit LCD display Degraded mode of operation Variety of mounting options Flexible time programming Supports loop powered sounders and switching relays introduction The NOTIFIER ID2000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions whilst remaining easy to install, program and operate. The ID2000 has been 3rd party-certified to the current EN54 standard Parts 2 and 4. Advanced design and manufacturing techniques coupled with NOTIFIER s experience of over 50 years at the forefront of the fire industry, ensure that the ID2000 sets new standards in many areas such as product functionality, flexibility, user friendliness and reliability. A full range of intelligent sensors, advanced detection products, input and output devices, repeaters, mimic drivers, printers and other peripherals complement the ID2000. The ID2000 panel can be networked to extend the total capacity of the system for larger applications. The ID2000 has been designed to operate with NOTIFIER s ID1000 and ID3000 intelligent fire alarm panels in networking configurations, allowing for upgrades and extensions to existing sites. The modular design of the ID2000 offers solutions for a wide range of applications, facilitating installation and servicing while making it very easy for the ID2000 to be tailored to the requirements of the application. system The NOTIFIER ID2000 intelligent fire alarm panel is ideally suited to a broad range of applications such as shopping malls, schools, office buildings, hospitals, hotels, factories and large warehouses. With its expansion capability the ID2000 provides control of 2 to 8 loops, with each loop having a capacity of 198 devices (99 sensors and 99 modules). The modular design of the ID2000 allows the user to configure the panel to their exact application requirements. Three sizes of power supplies are available (2.5A, 4.5A and 7A) to cater for the needs of small, medium and large systems. Internal and external

printer options, a variety of mounting options and the optional loop and communication expansion modules all provide a high degree of flexibility during initial design with a ready-made expansion path for the future. The simple, menu driven, user interface brings full system monitoring and control functions to the fingertips of the system operator. Zone status LEDs are provided for up to 16 zones. Further zone status indicator LED s can be added for up to 80 zones per panel to give the user additional status indicators. configuration The NOTIFIER ID2000 is a fully onsite programmable intelligent fire alarm panel. It can be programmed from the panel keypad or from a personal computer using the off-line configuration tool. An "Auto-Learn" facility allows the user to install and commission a standard system with the minimum of effort. If a more complex "Cause & Effect" matrix is required, the ID2000 may be programmed to meet individual site requirements by means of powerful "Control By Event" (CBE) rules. Using CBE rules, site-specific requirements such as plant shutdown, fire door control, smoke control, phased evacuation, point/zone isolation, point-tooutput controls and many others can be programmed with relative ease. Devices can be grouped into 80 zones per panel for control and monitoring purposes. Furthermore, the CBE rules can be initiated and combined through flexible time programs. The ID2000 can be programmed to compensate for the differences in the use of the areas where the smoke sensors are used. A total of 9 different sensitivity levels can be assigned to individual smoke sensors, thereby allowing the system designer to closely match the sensor s response to the environment in which it is located. Using time programs, different sensitivity settings can be selected at different times of the day. For example, to avoid false alarms, smoke sensor sensitivity can be lowered during the day when a meeting room is likely to be used by smokers and returned to a high sensitivity during the night time when the premises are unoccupied. System security and integrity is an important aspect of the ID2000. The cover of the ID2000 cannot be removed without a special tool and an optional tamper switch can be installed to protect against unauthorised cover removal. In addition, two levels of Password protection makes it virtually impossible for unauthorised people to access the panel and its manual controls to change the system configuration. All configuration data is retained in non-volatile memory and is, therefore, protected against complete failure of the mains and backup power supplies. networking Where multiple control panels are required, the ID2000 intelligent fire alarm panels may be combined in a network of up to 8 panels giving a maximum system capacity of 64 loops with a total of 12,672 points. In the event of a network failure all control panels will resume normal local operation in stand-alone mode. The ID2000 network is an RS485 serial data link which can support up to 32 network stations, comprising fire control panels, IDR2A and IDR2P repeaters and/or mimic drivers. Up to a maximum of 8 stations can be ID2000 control panels. The network supports general control functions such as Reset, Silence, Mute, Evacuate and more specific functions such as Zone Isolate, Walk Test, Zone Event Broadcast and Control by Event (CBE) across the network. Full system monitoring and control is easily achieved from the main control panel. The ID2000 network is compatible with NOTIFIER s ID1000 and ID3000 intelligent fire control panels. However, if an ID2000 panel is connected to an ID1000 network, there will be some

ID2000 limitations as the ID1000 network does not support all of the ID2000 functionality. If connected to an ID3000 network, the ID2000 will not support all of the functionality offered by the ID3000. mounting options A wide variety of mounting options is available with the ID2000. The basic back-box options (standard, single extended and double extended) with matching bezels lend themselves to surface mounting and flush mounting respectively. A full range of 19-inch rack mounting assemblies address the needs of more industrial-type installations. As with all other ID series intelligent fire alarm panels from NOTIFIER, the ID2000 comes in the Black/Grey NOTIFIER colour as standard. A light grey cover and bezel option with a high quality, velvet imitation finish and a stainless steel cover, with optional bezel, offering clean, bright looks are also available for more architecturally-challenging sites. In areas where visibility is important or where local codes require, the full range of backboxes, covers and bezels are also available in red. The modular, 19-inch rackmounting range combines the industrial versatility of 19-inch rack mounting with the aesthetically pleasing appearance of the ID Series fire control panels. A combination of 3U and 6U size mounting assemblies is available for the various modules. repeater & mimic driver options The IDR Series repeaters and mimic drivers complement the ID Series intelligent fire alarm panels. By placing repeaters and/or graphical mimic display panels at strategic points in the facility - such as nurse stations, floor landings, gatehouse or control rooms - valuable time can be saved when identifying the location of a fire and/or evacuating the building. The IDR Series repeater panels combine a compact design with a 2 x 40 character LCD. The LCD replicates the display on the ID2000 fire control panel, and adopts the same, simple, menudriven user interface. The control buttons and navigation keys on the repeaters enable the operator to easily navigate through the menu options and event displays. The nine LED indicators provide the user with a quick summary of the general system status. The compact design of the repeaters makes them very easy to install and commission. Unlike conventional repeaters, the IDR series store event information of up to 150 events, therefore, making commissioning very easy. Two models are available: a) IDR2A active repeater: The IDR2A active repeater mimics the LCD & LED status indications on the main fire alarm panel and allows the operator to control the system via push-buttons such as Mute Buzzer, Accept, Evacuate, Silence Sounders, Resound Sounders and Reset. The IDR2A has built-in configuration and standard test functions such as Edit Normal Message, Lamp Test, LCD Test and Buzzer Test. The IDR2A repeater also has Power Diagnostics and a Push-button Test option.

b) IDR2P passive repeater The IDR2P passive repeater is an indication-only module with no controls. The LCD and common system LEDs reflect the status indication of the fire alarm control panel. The IDR2P has the same configuration and standard test functions described for the IDR2A module. The Mimic Driver consists of the main mimic control unit and up to 8 mimic drivers. The mimic driver kit consists of a mimic driver board and two termination boards for field wiring and has 64 opencollector drivers for LEDs. The main mimic control unit supports up to 8 mimic driver kits connected in a "daisy chain" arrangement, to provide a total of 512 outputs per mimic. The mimic driver board also has 8 programmable digital inputs/ outputs. These inputs/outputs can be programmed to perform various functions such as Lamp Test, Reset and Accept or to drive relays. The main mimic control unit can be programmed, using the onboard DIP switches, for simple zone fire/fault indication. The DIP switches can be set-up for "fire only" or "fire and fault" indication on the mimic display. The Windows -based IDR configuration tool allows more complex mimic display "Cause & Effect" tables to be easily programmed into the main control unit. graphical display and control system The ID2000 is fully compatible with the UniNet-ID graphics system. This allows up to two hundred ID2000 systems to be connected to a single UniNet-ID server. Up to 10 servers can also be networked together, using standard TCP/IP protocol, to provide a single system gateway to a large ID2000 system. UniNet-ID is the next generation in advanced technology to monitor and control fire and other facility information over a LonWorks network. The LonWorks network supports a variety of network topologies and media (wire, fibreoptic, etc.) and is an industry standard, open architecture. The UniNet-ID Workstation Software provides the operator interface to the UniNet-ID System. The workstation features standardised plug-in applications, to allow continued expansion of workstation and network functions. These applications can add new features to the software, implement features specific to certain devices, or even add situation and facility specific features. The ID2000 plug-in provides the user with complete control over all points in the system and includes: Accepted, Silence, Resound, Reset, Disable Zone, Enable Zone, Disable Device, Enable Device, Test Zone, Terminate Test & Evacuate. The UniNet-ID also allows a combination of these functions to be added together in a Macro. This allows the system provider to customise the workstation to provide functions, such as disable multiple plant shut downs, from a single, push button. All functions can be disabled at various security access levels. The workstation uses Microsoft Windows 2000 to provide an easy-to-use and easy-to-learn graphical user interface. The operator is presented with a consistent look and operation for all monitored equipment. The workstation features customerconfigurable screens and allows a wide variety of configuration options for any situation.

international offices UK AUSTRALIA BENELUX BRAZIL CANADA CHILE CHINA GERMANY HONG KONG INDIA ITALY JORDAN LEBANON MEXICO SINGAPORE SOUTH AFRICA SPAIN SWEDEN USA VENEZUELA Charles Avenue T: +44 (0) 1444 230 300 Burgess Hill F: +44 (0) 1444 230 888 W. Sussex E: sales@notifierfiresystems.co.uk RH15 9UF www.notifierfiresystems.co.uk local distributor Every care has been taken in the preparation of this data sheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. available only from your NOTIFIER Engineered System Distributor Ref: 120(1101)