Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

Similar documents
Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Distinctive Series Cooktop

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Installation Instructions Renaissance. Rangetop. Models: EG366, EG486

Installation Instructions. Discovery Rangetop. Models: DYRTP366, DYRTP486, HRTP366, HRTP486

Installation Instructions Induction Cooktop

Installation Instructions Dual Fuel Ranges

Installation Instructions Preference Wall Mount Range Hood

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

Integrated Hood Liner

Downdraft Raised Vent

GAS COOKTOP INSTALLATION INSTRUCTIONS

Integrated Ventilation System

Installation Instructions Epicure. 36-Inch Gas Range. For use with models ER36G and ER36GI

Installation Instructions. Discovery Wall Oven. EO, MOH and MOV Series. Part No Rev. M

Multi-Function Cooktop

Installation Instructions Epicure. 30-Inch Gas Range. For use with models ER30G and ER30GI

Modernist Warming Drawer

Integrated Hood Liner

THIS APPLIANCE HAS BEEN TESTED IN ACCORDANCE WITH THE LATEST EDITIONS OF ANSI Z21.1 STANDARDS FOR HOUSEHOLD APPLIANCES.

Installation Instructions. Renaissance Range

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

Installation Instructions Built-In Wine Coolers, Beverage Centers

Installation Instructions Renaissance Integrated Hood Liner

Installation Instructions Remote Blowers

Installation Instructions. Warming Drawer

Installation Instructions. Warming Drawer

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models EO, MO and PO

DESIGN CLASS FUNCTION

Installation Instructions. Warming Drawer. Preliminary - For Review Only

Installation Instructions Outdoor Refrigerator

Installation. Instructions. Distinctive. Series. Cooktop. Model DCT365

Modernist Rangetop DTT36M974L*/DTT48M976L* Installation Instructions

SAVE AND READ THESE INSTRUCTIONS

Installation Instructions. Warming Drawer. Models: EWD24, EWD27, EWD30, EWD36, IWD24, IWD27, IWD30, MWDV27, MWDH27, MWDV30, MWDH30 PWD27, PWD30

Installation Instructions Millennia Cooktops

Viking Installation Guide

Installation Instructions. Discovery Wall Oven. Preliminary - For Review Only No Scheduled Release Date. For use with models: EO, MO and PO

Gas Cooktop Installation, User and Service Instructions GMS 955.1

INSTALLATION GUIDE Dual Fuel Ranges

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

Installation Instructions Renaissance Built-in Dishwasher

DESIGN CLASS FUNCTION

Installation / Assembly

user manual Model #: BLZ-WVH-42

Instructions. Installation. Gas. Cooktop. Models: SGM304, SGM365, SGM466

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION MANUAL. Double Electric Wall Oven

user manual Model #: BLZ-HOOD

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MANUAL STEEL GAS STAR COOKTOPS 30" MODELS: SGS304, SGSX304 36" MODELS: SGS365, SGSX365 45" MODELS: SGS456, SGSX456

Installation Instructions

Installation Instructions Renaissance. Gas Range

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Instructions Dual Fuel Ranges

2 Finding Information

36" GLASS SEALED-BURNER GAS COOKTOP

Ins t a l l a t i o n In s t r u c t i o n s Wa r m i n g Ov e n For use with models: EW, EWO MW, MWO PW, PWO IWO, IOWO

Viking Installation Guide

GAS COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

INSTALLATION MANUAL. Rangetops. RNB Heritage Classic Platinum

Installation Instructions

Installation Instructions

Use and Care Manual Downdraft Raised Vent

Operating and Installation Instructions

Distinctive TM Electric Cooktop

NATURAL GAS CONVERSION KIT

Service Manual Electric Cooktop

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

USE AND CARE MANUAL GAS COOKTOP MODELS: CTG304D, CTG305D, CTG365D

Operating and Installation Instructions

NOTE: THIS APPLIANCE MUST BE INSTALLED SOLELY AND EXCLUSIVELY BY A QUALIFIED TECHNICIAN.

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions Wall Ovens

INSTALLATION INSTRUCTIONS

Use and Care Manual Distinctive Series Cooktop Models DCT305, DCT365

Modernist Pro Range DOP48M96DL*/DOP36M94DL* Installation Instructions

Downdraft Ventilation

Failure to follow these instructions could result in fire or explosion which could cause property damage, personal injury or death.

Use and Care Manual Downdraft Raised Vent

user manual Model #: BLZ-WVH-42

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

Using it in an enclosed space can kill you.

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

USE & CARE GUIDE SINGLE SIDE BURNER MODEL BLZ-SB1(NG/LP) DOUBLE SIDE BURNER MODEL BLZ-SB2(NG/LP)

INSTALLATION GUIDE Fryer Module

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

Installation Instructions

Natural Gas Conversion Instruction for

INSTALLATION MANUAL. Free Standing Ranges. RCS (Open/Sealed) RNB RPB Platinum Precious Metals 1

Use and Care Manual Preference Renaissance Cooktop

Transcription:

Discovery Gas Cooktop Models DYCT304G, DYCT365G Installation Instructions Part No. 108861 Rev. A

Important Safety Instructions...1 Important Information About Safety Instructions...1 General Safety Precautions...2 Electrical Requirements...3 Gas Supply Requirements...3 Installation Specifications...4 Product Dimensions...4 Cabinet and Countertop Layout...6 Important Table of Contents Before You Begin... Verifying the Package Contents...8 Installing the Cooktop...8 Connecting the Gas Line...8 Assembling the Burners...9 Verifying the Correct Setup...10 Installation Checklist...11 Replacement Parts List... 12 iring Diagrams... 14 Installer: In the interest of safety and to minimize problems, read this Installation Instruction manual completely and carefully before you begin the installation process. Leave this Installation Instructions with the consumer. rite the Product Data Label information inside the Use and Care manual for the consumer s future reference. Consumer: Keep these Installation Instructions for future reference and for the local electrical inspector s use. Note: Dacor is not responsible for service required to correct a faulty installation. Customer Service Information If You Need Help... If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. henever you call, have the model and serial number of the appliance ready. The model and serial number are printed on the product data label. Dacor Customer Service Phone: (800) 793-0093 ex. 2813 (U.S.A. and Canada) Monday Friday 6:00 a.m. to 5:00 p.m. Pacific Time ebsite: www.dacor.com Dacor Distinctive Service (repairs under warranty only) Phone: (800) 793-0093, ex. 2822 (U.S.A. and Canada) Monday Friday 6:00 a.m. to 5:00 p.m. Pacific Time Product Data Label The product data label is attached to the chassis, underneath the unit. The label contains: the model number and serial number the electrical requirement and gas supply requirements Product data label Model Shown: DYCT365G Product Data Label Location All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications. 2015 Dacor, all rights reserved.

Important Information About Safety Instructions Important Safety Instructions The Important Safety Instructions and warnings in these instructions are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you don t understand. See Customer Service Information. Safety Symbols, Labels, and Alerts These danger and warning alerts signal the reader to the risk of death or serious injury: DANGER Immediate hazards that ILL result in severe personal injury or death. ARNING Hazards or unsafe practices that COULD result in severe personal injury or death. IMPORTANT: If you smell gas: DANGER Do not use or light any appliance. Do not touch any electrical switch or use any electrical devices, including the telephone, in your building. From a neighbor s phone, immediately call the gas supplier. Follow the gas supplier s instructions. If you cannot contact the gas supplier, call the fire department. DANGER IMPORTANT: Do not store or use combustible, flammable or explosive vapors and liquids (such as gasoline) on or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans, away from the cooktop. Do not store flammable or explosive materials in adjacent cabinets or areas (including above and below the cooktop). ARNING ARNING: NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating of the appliance. ARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE: a. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b. NEVER PICK UP A FLAMING PAN - you may be burned. c. DO NOT USE ATER, including wet dish cloths or towels - a violent steam explosion may result. d. Use a fire extinguisher ONLY if: You have a Class ABC extinguisher, and you already know how to operate it. The fire is small and contained in the area where it started. The fire department is being called. You can fight the fire with your back to an exit. ARNING ARNING: NEVER cover any slots, holes, or passages on the cooktop and cooktop chassis. Doing so blocks air flow through the cooktop and may cause carbon monoxide poisoning. Aluminum foil linings may also trap heat, causing a fire hazard. Keep all slots, holes, and passages clear of grease and grime. CALIFORNIA PROPOSITION 65 ARNING The burning of gas cooking fuel generates some by-products that are on the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these substances, always operate this unit according to the Use and Care manual, ensuring you provide good ventilation when cooking with gas. PROLONGED POER FAILURE Do not attempt to use this appliance during a continuous power failure. READ AND SAVE THESE INSTRUCTIONS 1

Important Safety Instructions General Safety Precautions To reduce the risk of fire, electric shock, or serious injury or death when using your appliance, follow basic safety precautions, including the following: ARNING Read the accompanying use and care manual completely before operating this appliance. Keep packaging materials away from children. Plastic sheets and bags can cause suffocation. If you receive a damaged product, immediately contact your dealer or builder. Do not install or use a damaged appliance. This cooktop must be properly installed and grounded by a qualified installer according to these installation instructions prior to use. The installer should show the customer the location of the gas shut off valve and the power cord so that they know where and how to turn off the gas supply and disconnect power to the cooktop. Do not install, repair or replace any part of the cooktop unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Before servicing or installing this cooktop, make sure that the gas supply is turned OFF at the gas supply valve and that the power plug is disconnected from the electrical outlet. Disconnect the power plug from the electrical outlet before cleaning. Clean this appliance only in the manner specified in the Use and Care Manual. Only use the cooktop for cooking tasks expected of a home appliance as outlined in the literature accompanying it. This cooktop is not intended for commercial or laboratory use. DO NOT TOUCH THE SURFACES OF THE COOKTOP DURING OR IMMEDIATELY AFTER USE. Do not operate this appliance if the power cord is damaged. Turn the knobs to the OFF position prior to removing them from the valve stems. Clean the cooktop thoroughly before operating it for the first time. Make sure that all the cooktop parts are dry before lighting a burner. To avoid a fire hazard, do not hang flammable or heat sensitive objects over the cooktop. Do not climb on any part of the appliance. ARNING Do not leave the cooktop unattended while in use to avoid the possibility of a fire. Do not leave children alone or unattended in the area around the cooktop. Do not allow children to play with the controls or touch other parts of the cooktop. Do not store items of interest to children on top of or above the cooktop. Children could be burned or injured while climbing on the appliance. Keep flammable items, such as paper, cardboard, plastic, and cloth away from the burners and other hot surfaces. Do not place such items on the cooktop. Do not allow pot holders to touch hot surfaces or gas burners. Do not wear loose or hanging apparel while using the cooktop. Do not allow clothing to come into contact with the cooktop and surrounding areas during and immediately after use. If the cooktop is near a window, do not use long curtains as window treatment. The curtains could blow over the cooktop and create a fire hazard. Do not use towels or bulky cloth as pot holders. Do not use the cooktop to heat sealed containers. The container and contents may explode, causing personal injury. Non-stick coatings, when heated, can be harmful to pet birds. Relocate pet birds to a separate, wellventilated room when using the cooktop. IMPORTANT - This appliance is equipped with a three-prong grounding plug for your protection against possible electric shock hazards. Plug it only into a dedicated, grounded three-prong electrical outlet. It is the responsibility of the customer to make sure the proper type of outlet is installed. Under any circumstances: DO NOT cut or remove the third (ground) prong from the power cord. DO NOT use an adapter plug. DO NOT use an extension cord. DO NOT use a power cord that is frayed or damaged. 3-prong plug 3-prong outlet DO NOT connect to an electrical outlet with a ground fault interrupter (GFI). 2

Important Safety Instructions Electrical Requirements ARNING To prevent an electric shock hazard, the power supply must meet the specifications stated below. It is the owner s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed by a licensed electrician. The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical cord. It is connected to the chassis at the bottom right rear corner (see Chassis Bottom Diagrams below). It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician. The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70* and local codes and ordinances. A copy of this standard may be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02269-9101 The correct voltage, frequency, and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis. See the Gas and Electrical Requirements table on this page for reference. Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service. Chassis Bottom Diagrams DYCT304G DYCT365G Gas Supply Requirements Be certain that the cooktop being installed is correct for the gas service being provided (Natural Gas or LP gas). Also, if using the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude ( H ) operation. Units equipped for high altitude operation have an H at the end of the model number listed on the product data label. Units equipped for LP operation have LP in the model number listed on the product data label. See the Product Data Label section for label location. Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54. An external manual shut-off valve must be installed between the gas supply line and the cooktop for the purpose of turning on or shutting off gas to the appliance. The cooktop is shipped from the factory with a regulator in the carton. Use only the regulator provided. The regulator must be installed between the gas inlet on the cooktop and the gas shut-off valve. The regulator inlet accommodates a 3/4 gas line. The cooktop inlet itself is equipped with a 3/4 male NPT fitting. See the DYCT304G and DYCT365G images on the left. DYCT304G/NG DYCT365G/NG DYCT304G/LP DYCT365G/LP Gas Type Natural Gas LP Gas Manifold Pressure Min. Gas Supply Pressure ** Max. Gas Supply Pressure Total Connected Load Circuit Requirement 5-inch ater column 6-inch ater column 10-inch ater column 11-inch ater column 1/2 psi 1/2 psi 0.25 Amp. (0.03 k) 120 Vac, 60 Hz, 15 Amp. 0.25 Amp. (0.03 k) 120 Vac, 60 Hz, 15 Amp. Gas and Electrical Requirements* * The electrical and gas data on this page is for reference only. If the above data does not agree with the product data label, use the data on the product data label. ** The gas supply pressure for testing the regulator setting shall be at least 1-inch water column (249 Pa) above the specified manifold pressure. 3

Installation Specifications ARNING Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Product Dimensions All tolerances: ±1/16 (±1.6 mm) unless otherwise noted. Model DYCT304G Bottom of spill tray to top of cooking surface 2 1/8 (5.4 cm) 30 (76.2 cm) Chassis height 4 (10.2 cm) 21 (53.3 cm) 19 1/2 * (49.5 cm) 27 1/2 * (69.9 cm) * Including raised embosses on sides of chassis Front of cooktop Power cord Chassis Gas inlet 2 1/8 (5.4 cm) 5/8 (1.6 cm) DYCT304G Power Cord and Gas Inlet Location 3 3/4 (9.5 cm) 13/16 (2.1 cm) Top panel overhang 4

Installation Specifications Model DYCT365G 36 (76.2 cm) Bottom of spill tray to top of cooking surface 2 1/8 (5.4 cm) Chassis height 4 (10.2 cm) 21 (53.3 cm) 33 5/8 * (85.4 cm) 19 1/2 * (49.5 cm) * Including raised embosses on sides of chassis Gas inlet Front of cooktop Power cord in Chassis 2 1/4 (5.7 cm) 1 (2.5 cm) DYCT365G Power Cord and Gas Inlet Location 1 3/8 (3.5 cm) Top panel overhang 1 (2.5 cm) 5

Cabinet and Countertop Layout Installation Specifications ARNING To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop. Failure to meet or exceed the maximum and minimum dimensions/clearances stated in these instructions may result in a fire hazard. Follow the countertop manufacturer s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc. Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows, and heating and air conditioning vents. This appliance is to be used in conjunction with a suitable vent hood or approved Dacor downdraft vent. Minimum Required Clearances Around the Cooktop Refer to the following illustrations and notes for clearance allowances. Model (A) Minimum (A) Recommended DYCT304G 30 (76.2 cm) 36 (91.4 cm) DYCT365G 36 (91.4 cm) 42 (106.7 cm) All tolerances: +1/16-0 unless otherwise noted. Combustible overhead cabinets 13" max. (33.0 cm) Combustible surface to rear See cutout dimensions 30" min. 1, 2 (76.2 cm) A 1 7/8" min. (4.8 cm) 15" min. 1 (38.1 cm) See Note 3 Model DYCT304G DYCT365G (B) Minimum to allow for clearance of hold-down brackets 29 in (73.7 cm) 35 1/4 in (89.5 cm) Allow a minimum 1/4 (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer inside the countertop cabinet below the cooktop. The gas supply piping, gas shut-off valve, and the electrical outlet must be located so they do not interfere with the cooktop after it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it. The installation must allow for the following: Access to the gas shut-off valve and regulator when the unit is installed. The 40-inch (101.6 cm) power cord must be able to reach an electrical outlet, and that electrical outlet must be easily accessible after the cooktop is installed. Access to the underside of the cooktop for service and inspection purposes. Clearance inside the counter to allow for correct installation of the hold-down brackets. To allow underneath access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop. See the following pages for countertop cutout dimensions. Downdraft Compatibility If installing the cooktop with a downdraft, use only the approved Dacor downdraft model numbers below: Cooktop Models DYCT304G DYCT365G B 1/4 (6 mm) min. height clearance to combustible surfaces Underneath Cabinet Dimensions All tolerances: +1/16-0 unless otherwise noted. Approved Downdraft Models ERV3015, PRV30, or RV30 ERV3615, PRV36, or RV36 1 Measured from the cooking surface (top of cooking grate). 2 If installing an overhead vent hood, check the hood installation instructions for the minimum required clearance specifications and requirements. 3 Not required if the side cabinets are at least 6 inches or more from both sides of the cooktop. 6

Cutout Dimensions Installation Specifications All tolerances +1/16-0 (+1.6 mm) unless otherwise noted. Countertop Cutout View Rear wall Vertical combustible surface 4 1/4" (10.8 cm) min. from mounting surface to combustibles below cooktop chassis F C E D Countertop Cutout Dimensions 1 7/8" min. (4.8 cm) F Min. distance to combustible side wall above countertop (both sides) Installation Type (C) Minimum (D) (E) (F) DYCT304G with no downdraft 2 7/8 (7.3 cm) 19 3/4 (50.2 cm) 27 5/8 7 1/2 DYCT304G with ERV3015 or PRV30 3/8 (1.0 cm) 22 1/2 (57.2 cm) (70.1 cm) (19.1 cm) DYCT304G with RV30 5/8 (1.6 cm) 22 1/4 (56.5 cm) DYCT365G with no downdraft 2 7/8 (7.3 cm) 19 3/4 (50.2 cm) 33 3/4 DYCT365G with ERV3615 or PRV36 3/8 (1.0 cm) 22 1/2 (57.2 cm) 7 (17.8 cm) (85.7 cm) DYCT365G with RV36 5/8 (1.6 cm) 22 1/4 (56.5 cm) 3/8 min. (1.0 cm) required for downdraft cap clearance Countertop 5/8 min. (1.6 cm) required for downdraft cap clearance Countertop 23 3/8 (59.4 cm) 23 1/8 (58.7 cm) Stiffener DYCT Gas Cooktop Stiffener DYCT Gas Cooktop Cabinet face 3/8 min. (1.0 cm) space behind downdraft to clear stiffener Cabinet face 5/8 min. (1.6 cm) space behind downdraft to clear stiffener ERV or PRV Series Downdraft: check downdraft specifications to determine correct fit RV Series Downdraft: check downdraft specifications to determine correct fit Floor Floor Cooktop with Downdraft: ERV/PRV Series Cooktop with Downdraft: RV Series 7

Verifying the Package Contents Hold-down brackets (2) Grates: DYCT304G (2), DYCT365G (3) Burner sets: DYCT304G (4), DYCT365G (5) Gas pressure regulator (1) Stainless steel cleaner (1) (stainless steel models only) If any parts are missing, see the Replacement Parts List section on page 12 for Dacor Customer Service and ordering information. Installing the Cooktop ARNING Verify that the power supply meets the specifications on page 3 before proceeding. To prevent damage to the gas pressure regulator, install it only after the cooktop is mounted in its permanent position. IMPORTANT Do not over-tighten the hold-down bolts. Over tightening the hold down bolts may result in improper operation of the dual gas burners. Do not use a hardening compound or caulk to permanently seal the cooktop into place. The cooktop must be readily removable if service is required. Removal of sealant to service the unit will be performed at the customer s expense. 1. If the cooktop will be used with a downdraft, first install the downdraft according to the downdraft installation instructions. 2. Lower the cooktop into the cutout and center it. 3. Secure the cooktop to the countertop using the two (2) hold-down brackets as shown (included). Hold-down bracket mounting holes (both sides) Installation Instructions Gas inlet Power cord Model DYCT365G Underneath the Cooktop Connecting the Gas Line ARNING Verify that the gas supply meets specifications before connection. See page 3. Do not install or use the cooktop without the included gas regulator installed. Ensure that the arrow on the regulator points in the direction of the gas flow, toward the cooktop. Do not apply excessive pressure when tightening gas connections and fittings. Do not use Teflon tape or plumber s putty on flexible gas line connections. Before use, test the gas lines for leaks as instructed. Do not use a flame to check for leaks. The maximum gas supply pressure to the regulator must never exceed 1/2 pounds per square inch (psi) or 3.5 kpa. The cooktop and shut-off valve must be disconnected from the gas supply piping system during any pressure testing exceeding 1/2 psi (3.5 kpa). The cooktop must be isolated from the gas supply piping system by closing the shut-off valve to the cooktop during any gas supply piping system pressure testing equal to or less than 1/2 psi (3.5 kpa). For LP gas installations, the LP gas tank must have its own high-pressure regulator in addition to the pressure regulator supplied with the cooktop. Refer to the figure Underneath the Cooktop on the left while following these gas hookup instructions. 1. Attach the gas pressure regulator (included) to the gas inlet on the cooktop. hen working in tight space constraints, the regulator can be installed anywhere between the cooktop and gas supply/shut-off valve. For best performance, attach the regulator as close as possible to the cooktop. This will minimize gas pressure loss. 2. Connect regulator to the gas supply/shut-off valve with a minimum 1/2 flexible gas line (not included). 3. Check for gas leaks: Turn all cooktop control valves to OFF. Make a soap and water solution or use a gas leak detector and check all lines and connections for gas leaks. * Make sure the gas supply/shut-off valve is ON. Turn the gas supply/shut-off valve OFF. 8

Assembling the Burners Installation Instructions ARNING Never attempt to operate the cooktop with any of the burner parts removed. Do not attempt to adjust the burner air mixture settings. All adjustments are preset at the factory. 1. Remove the burner heads, burner rings, burner caps, and grates from their shipping packages. 2. Assemble the burners as shown below. hen assembling the burner components, twist each piece back and forth until it drops completely into place. The burners will not function properly unless all of the burner pieces are correctly seated. 3. Gently set the grates on top of the spill tray. Make sure that the rubber feet are placed in the indentations located in the spill tray. Grate Feet Cap cover (bottom view) Burner head Cap cover Line up this notch with the igniter Igniter Burner cap Burner skirt ide side down Burner head * Burner base Single Burner Assembly SimmerSear Burner Assembly Burner and Grate Diagram for DYCT304G and DYCT365G * The SimmerSear burner head is permanently attached to the burner base. It cannot be removed by the user. 9

Verifying the Correct Setup ARNING Make sure that power to the electrical outlet is turned off at the circuit breaker panel or fuse box and that the gas is turned off at the gas supply valve before proceeding. The cooktop must be properly grounded at all times when electrical power is applied. Prior to operating the cooktop, read the accompanying Use and Care Manual carefully. 1. Make sure all the cooktop burner controls are in the OFF position. 2. Connect the power cord to the electrical outlet. 3. Turn on power to the electrical outlet at the circuit breaker or fuse box. 4. Press and turn ONE burner control knob slowly left to the HIGH position. Verify that the associated burner igniter sparks, then return the knob to the OFF position. Repeat for all of the remaining control knobs. 5. Turn gas supply valve ON. 6. Perform this IGNITION TEST on all burners: Press and turn the control knob slowly left to the HIGH position. Only the selected burner will spark. It may take up to four seconds for the burner to ignite, at which time the igniter will stop sparking. If ignition does not occur within four seconds, turn the knob OFF, wait for at least five minutes to allow any gas to dissipate, then repeat this step. Once the burner lights, rotate the control knob from HIGH toward LO to adjust the flame height. SimmerSear burners: turn the control knob to the simmer setting, and make sure the low-level flame can be adjusted. hen the unit is installed correctly, the flame will burn steadily. It will have a sharp, blue inner cone that will vary in length proportional to the burner size. The flame will be reduced by the Smart Flame feature under the grate fingers to increase the life of the grate. Installation Instructions NOTE: If the cooktop does not function properly, follow these troubleshooting steps: Verify that power and gas are supplied to the cooktop. Check to make sure that the power cord is connected to an electrical outlet and that power is turned on at the circuit breaker, fuse box, or light switch. Check to make sure that all the burners are correctly assembled and seated. If the burner continues sparking after ignition, have a licensed electrician check the electrical outlet for correct grounding or reversed polarity. Repeat the IGNITION TEST (Step 6). If the appliance still does not work, contact Dacor Distinctive Service at (800) 793-0093, ex. 2822. Do not attempt to repair the appliance yourself. If you need service, be sure to have the model and serial numbers available when you call. See inside cover for location. Dacor is not responsible for the cost of correcting problems caused by a faulty installation. High Flame SimmerSear Control Knob High Flame Light Burner Light Burner Burner Indicator Burner Indicator On Low Flame On OFF High Simmer OFF Simmer Low Correct Flame Appearance Single Burner Control Knob Low Flame 10

Installation Checklist ARNING To ensure a safe and proper installation, the following checklist should be completed by the installer to ensure that no part of the installation has been overlooked. Proper installation is the responsibility of the homeowner. The importance of proper installation of your Dacor cooktop cannot be overemphasized. Is the electrical outlet for the cooktop grounded and located according to these instructions and in accordance with all applicable electrical codes? See page 3. Is the gas service for the cooktop located and installed according to these instructions and in accordance with all applicable codes? See page 3. Has the gas supply inlet pressure been measured to ensure that it does not exceed the maximums stated in these instructions? See page 3. Is the cooktop secured using the provided hold-down brackets? See page 8. Is the cooktop connected to the gas supply according to these instructions and in accordance with all applicable codes? Did the installer check the gas supply for leaks? See page 8. Are the burners and grates properly assembled according to these instructions? See page 9. Has the correct setup been verified? See page 10. Has the warranty been activated on-line or the warranty card filled out completely and mailed? Installation Instructions 11

Replacement Parts List Replacement parts can be obtained by contacting Dacor Customer Service. Dacor Customer Service Phone: (800) 793-0093 (U.S.A. and Canada) Monday Friday 6:00 a.m. to 5:00 p.m. Pacific Time Model DYCT3xxG Cooktop Parts See the Burner Parts and Cooktop Layout on right Cooktop Part Replacement Parts List Model DYCT304G Model DYCT365G Hold-Down Bracket w/screws (set of 2) PN 12269 PN 12269 Regulator (Natural Gas models) PN 62834 PN 62834 Regulator (LP Gas models) PN 72980 PN 72980 Knobs PN 109321 PN 109321 Trim Rings: Single LR (left rear) PN 108924-03 -- Trim Rings: Single RF, RR (right front, right PN 108924-02 -- rear) Trim Rings: SimmerSear PN 108925-02 -- LF (left front) Trim Rings: Single RR, CR, LR (right rear, center -- PN 108924-01 rear, left rear) Trim Rings: SimmerSear LF, CF -- PN 108925-01 (left front, center front) Grate: large PN 108900 PN 108900 Grate: small -- PN 108901 Grate support feet (4) PN 103712 PN 103712 Stainless steel cleaner PN A302 PN A302 Model DYCT304G See the Burner Parts and Cooktop Layout on right Burner Part Dacor P/N Cap Cover: LF (left front) 92231 Burner Cap: LF (left front) 92460 Burner Skirt: LF (left front) 92459 Cap Cover: LR, RF (left rear, right front) 92235 Burner Head: LR, RF (left rear, right front) 103735 Cap Cover: RR (right rear) 92236 Burner Head: RR (right rear) 103737 Model DYCT365G See the Burner Parts and Cooktop Layout on right Burner Part Dacor P/N Cap Cover: LF (left front) 92232 Burner Cap: LF (left front) 92230 Burner Skirt: LF (left front) 92226 Cap Cover: LR, RR (left rear, right rear) 92235 Burner Head: LR, RR (left rear, right rear) 103735 Cap Cover: CF (center front) 92231 Burner Cap: CF (center front) 92460 Burner Skirt: CF (center front) 92459 Cap Cover: CR (center rear) 92236 Burner Head: CR (center rear) 103737 Grate Sizes Grate: Large For models DYCT304G, DYCT365G Grate: Small For model DYCT365G 12

Replacement Parts List Burner Parts Grate Feet Cap cover Line up this notch with the igniter (bottom view) Igniter Burner head Cap cover Burner cap Burner skirt ide side down Burner head * Burner base Single Burner Assembly SimmerSear Burner Assembly * Burner head on SimmerSear is attached to the spill tray. Cooktop Layout LR RR Spill tray Burner Location Burner control knob & Trim ring LR RR Left Rear Right Rear LF RF SimmerSear control knob & Trim ring CR LF RF CF Center Rear Left Front Right Front Center Front DYCT304G LR CR RR Grate Grate Spill tray LF CF DYCT365G Burner control knob & Trim ring SimmerSear control knobs & Trim ring 13

iring Diagrams 120V, 60Hz. POER SUPPLY VERIFY PROPER OPERATION AFTER SERVICING IRING DIAGRAM DYCT304G CAUTION: LABEL ALL IRES PRIOR TO DISCONNECTION HEN SERVICING CONTROLS. IRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. 14

iring Diagrams 120V, 60Hz. POER SUPPLY VERIFY PROPER OPERATION AFTER SERVICING IRING DIAGRAM DYCT365G CAUTION: LABEL ALL IRES PRIOR TO DISCONNECTION HEN SERVICING CONTROLS. IRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. L N GRN 1 2 ISOLATOR BOARD P/N 106104 NO SITCH S1 NO SITCH S2 NO SITCH S3 N RE-IGNITOR RED L1 N RE-IGNITOR RED L1 N RE-IGNITOR RED L1 IGNITOR, LR BURNER IGNITOR, CR BURNER IGNITOR, RR BURNER 1 2 3 4 5 6 7 8 9 10 11 12 + - + - + - + - + - + - 1 2 3 4 5 6 7 8 9 10 11 12 NO SITCH S4 N RE-IGNITOR L1 RED IGNITOR, LF BURNER INDICATOR LED CF INDICATOR LED LF S4 NC SITCH (OPEN POSITION) NEON SIMMER INDICATOR LIGHT RESISTOR INDICATOR LED RR INDICATOR LED CR NO SITCH S5 N RE-IGNITOR L1 RED IGNITOR, CF BURNER INDICATOR LED LR S5 NC SITCH (OPEN POSITION) NEON SIMMER INDICATOR LIGHT RESISTOR 15

Dacor 14425 Clark Avenue, City of Industry, CA 91745 Phone: (800) 793-0093 Fax: (626) 403-3130 www.dacor.com