Similar documents
PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

We Are Lightning Protection

LOCAL STORM DATA SHEET

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

TECHNOLOGIES FOR LIGHTNING PROTECTION LOCAL STORM DETECTION AIR TERMINALS AND ACCESSORIES TRANSIENT OVERVOLTAGES PERMANENT OVERVOLTAGES WELDING

LEADERS IN OUTDOOR MAINTENANCE. Timely performance with technical competence

Pinhole Detector Data Sheet / Instructions

Innovation for prevention, safety and protection against lightning

Gallagher Perimeter Product Overview

Table W-4...Total Improvement Expenditures by Homeowner Characteristics:

Oklahoma and Texas Interdependency Along the I-35 Corridor

South Central & Rocky Mountain Service Centers

LPI Lightning Warning System - LWS MKIII

NOTHING BURNS BRIGHTER THAN OUR COMMITMENT TO MEETING YOUR NEEDS.

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

With CV Technology products and care, you ll be better protected from dust explosions.

LPI Lightning Warning System (LWS) MKIII

Solysmart fan monitoring system

LPI Lightning Warning System (LWS) MKIII

automatic FiReFighTing SYSTeMS in PainT booths

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

EMERGENCY ACTION PLANS HOW READY ARE YOU?

D At your side in oil and gas exploration

THE LEADER IN MANAGED SECURITY

Credit Suisse Retail Round-Up. December 15, 2009

countries and 9,000+ employees.

EMERGENCY PROCEDURES LOOK, LISTEN, AND RESPOND

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

COMPANY BROCHURE. Fire Protection for Industrial Facilities and Buildings

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Perimeter Product Overview. Effective protection for your business

Policy and Organizational Statements

PERSONS NEEDING ASSISTANCE who are unable to quickly walk down the exit stairwells should follow these alternative procedures:

Professional Publications and Presentations Published and Presented by Jack Poole, PE, Principal

Y. ORMIERES. Fire risk analysis method for nuclear installations

INCREASING SAFETY THROUGH THE INTRODUCTION OF AN ELECTRONICALLY-BASED CENTRALIZED BLASTING SYSTEM. P J Laubscher DetNet South Africa

Hazardous Location Surge Protection Solutions

TRACY A. RAPP, P.E., CFEI Electrical Engineer Industrial, Commercial, Residential

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

PROFESSIONAL PROFILE. EDUCATION 2002 Americus University Associate of Arts & Sciences EXPERIENCE

Southwest Service Center

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity.

MET 200 Lecture 5: Water. Fall Weather and Birds. Radar Story. Previous Lecture Seasons and Diurnal Cycle. Outline Seasons Diurnal Cycle 8 PM 9 PM

Evaluation and Compliance with Facility Siting Regulations in the US API RP 752 / 753 / 756

Monitoring solutions

Corporate Relocation & Retention

Retail security solutions

UL High-Tech Direct Newsletter. Delta Electronics: Listed & Verified

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

One call protects it all.

Table A-4...Professional and Do-It-Yourself Improvement Expenditures by Homeowner Characteristics: 2007

The evolution of level switches and detectors

Urban Fires & Wildfires November 3, 2009

The Boomburb Downtown. Robert Lang, Ph.D. Arthur C. Nelson, Ph.D. FAICP Metropolitan Institute at Virginia Tech

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

fuel leak detection find leaks before they find you

Connected Metro TRANSPORTATION MADE SEAMLESS. Unveiling the Capabilities of a Connected Metro

TOXIC AND FLAMMABLE GAS CLOUD DETECTORS LAYOUT OPTIMIZATION USING CFD

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

Propane Safety and WILDFIRES

Fire Sprinkler Success Stories: How do Sprinklers Save Lives. Viking Group, Inc.

Experience the difference.

City of Bartlesville. City of Bartlesville. Multi-Hazard. Hazard Mitigation Planning. Mitigation Plan Update

CURRICULUM VITAE OF BRIAN R. NETTLETON, P.E. November 2017

DE-tector. Innovation with Integrity. Narcotics & Explosives Detector CBRNE

Implementing a Combustible Dust Program. Presented by: Nick Miedema Amway EH&S For: Michigan Safety Conference

Pump Control Products, Packages and Systems

Proven Leaders in Security Solutions & Integration.

Infinity 2020 Perimeter Security System Overview & Advantages

Fire suppression systems for server rooms and data centres

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

ABOUT US OUR LEADERSHIP OUR MISSION OUR VISION

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

STRIKE GUARD DELIVERS:

that sense s of ecurity

When the Dust Settles: Combating Combustive Dust in Food Manufacturing

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Transit Oriented Development. PB PlaceMaking Group RTD Planning & Development Committee May 4, 2010

- Residential Fire Sprinkler -

FM Approved Fire & Gas Detection System

Property Inspected: 1228 Radcliffe Ave, Kingsport, TN 37664

Continuing Education Units (CEU)

Coastal Planning in Texas. Tony Williams Senior Director of Planning Coastal Resources Division Texas General Land Office

Tunstall Healthcare Freedom to live your life. Personal alarms 24/7 monitoring Care & activity sensors

Overview of Control System Design


A revolutionary development designed for expansive and connected living.

ASCO Series 185 Power Transfer Switches

Greenways as an alternative to traditional infrastructure. Green Infrastructure

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

Introducing Sentry Interactive

Protecting Facilities Against Explosions. Since 1956

Section 5 Brieser Construction SH&E Manual

Hospital Codes, Safety, Exposure Control, Emergency Plans Handout

Integrated Door Systems

ST More than the sum of their components GAS DETECTION SYSTEMS

Pipeline Intrastructure Monitoring for Third-Party Interference Detection

Welcome to the ABB Webinar

INTRODUCTION to MADSKY Roofers Ladder to Success. 9/12/2016 v2

Product Liability Fire & Explosion Capability Statement

Transcription:

Introduction There are 50 cloud-to-ground discharges per second globally. One of the most potentially catastrophic consequences of these discharges is the loss of human life. Additionally, these discharges affect over 30% of US businesses causing over $5 billion in damages due to loss in production time and economic damages from the lightning or its consequences such as fire. A proper preventive protection, Lightning Warning System, can avoid these catastrophic incidents. Having site-specific information about the risk of thunderstorms allows the user to take preventive measures in advance to protect today s modern operations. ATStorm is a state of the art, patented, cost-effective, site-specific solution that is the most technologically advanced Lightning Warning System available today. Lightning Warning is a key part of our Total Site and Facility Protection Systems for sensitive electronics, prevention of losses in industrial processes, assuring basic service continuity, and prevention of serious accidents. WHY ATSTORM v2 Lyncole continue s as the Nation s leader in Lightning Protection, Grounding and Surge Suppression Systems. We are proud to partner with Applications Technologies to announce our latest product, ATStorm. page 3

Where to apply ATStorm v2 OPEN AREAS Workplaces, sports or open air activities, competitions, multitudinous events, farming, ranching or fishing activities. INDUSTRIAL PROCESSES Prevention of loss in industrial processes and operations. TECHNOLOGY Computers, electric or electronic controls, emergency, alarm or security systems. applications Once the hazard is detected, preventive actions can be taken. They should always be specific for the object (people, structure, open area...) to be protected. Switch off the main electrical service. Switch on UPS or back up generators. End/Postpone high risk activities. Run devices or operations in safety mode. Evacuation of individuals. CONTINUITY OF SERVICE Operations where basic service continuity has to be assured: telecommunications, power supply, energy transport and distribution, health and emergency services. INFRASTRUCTURE Harbors, airports, trains, roads, highways, cable railway. HAZARDOUS PRODUCTS Prevention of serious accidents involving hazardous products and processes (flammable, radioactive, toxic, explosive). page5

In normal weather conditions there is a balance between positive and negative charges in the atmosphere, where the earth is more negatively charged than the atmosphere and the elements situated on the ground. EVOLUTION & LIFE CYCLE OF A THUNDERSTORM However, when the storm clouds are developed, there is a change in polarization: positive charges on the top part of the cloud, a zone of negative charges in the middle (temperatures of-10 to -20 C) and a small positive charge near the freezing point. As the lower part of the cloud gets charged negatively, a positive charge is induced on earth and on the elements on it, transforming the atmosphere into an electric field that can reach tens of kilovolts page6

PHASES: Stages of a Lightning Storm Phase 1 >> Phase 2 >> Phase 3 >> Phase 4 >> Before the first lightning discharge, charge separation can be detected at ground level using electric field measuring devices like ATStorm. The first lightning strike follows the initial charge separation about 5 minutes later. In most cases the first discharges are the intra-cloud type. Intra-cloud discharges are often followed by the cloudto-ground discharges with a delay that is in the range of a few minutes to an hour. This is associated to a more mature phase of the storm. Reduction of the electrostatic field until it gets to repose. At this stage there is a low probability of lightning strikes. page7

The TOUCHSCREEN Interface The key elements of any storm detector are the SENSOR and the INTERFACE. The state of the art, touch screen interface allows for intuitive system set up and programming. All configuration options are available from the touchscreen. No clumsy switches or dials. The touchscreen allows a friendly and easy programming of all the system parameters: Alarm levels Alarm signal (existence and duration of the sound alarm) Tolerances for the starting and ending of the alarm. The SENSOR Is able to detect the formation of a storm over the areaa where the detector is placed (within a radius of 20 kilometers). It has been designed to protect the measurement system from the inclemency of the weather, thus enhancing its functioning and its working life. Based on the FCES technology (field-controlled electro- - metric sensor), developed by Aplicaciones Tecnológicas, S.A. to enhance the storm detection. This technology is totally electronic and has no mobile or mechanical rmed over the area where the detector is placed. parts. It allows detecting even storms which are formed Key Elements page8

COST EFFECTIVE When we envisioned our new Lightning Warning System, we landed on a remarkable innovative design, we also however, were able to uphold the integrity of the design while remaining cost effective to all of our clients. Creating a Lightning Warning System, which is the final piece of our Total Site and Facility Protection Systems, meant upholding Lyncole s innovative engineering capabilities and heightening industry standards. We understand the challenge of having to make the decision to halt activities such as: Sporting Events Workplaces where operations for basic service continually have to be assured (telecommunications...) Infrastructures such as harbors, airports, trains, and highways. Making this decision to halt or even postpone these activities due to lightning and when to resume can be frustrating due to the unpredictability of nature. Lightning in particular is most random in its behavior and cannot be ignored. Our ATSTORM v2 Lightning Warning System alleviates these challenges and virtually pays for itself after one use. Industry leaders across the nation have been provided with peace of mind by protecting their employees and customers, infrastructures, and equipment by installing ATSTORM v2 Lightning Warning System as part of their Total Site and Facility Protection Plan. page9

CONTACT US Lyncole is your best source for Total Site & Facility Protection needs including: Grounding, Lightning Protection, Surge Suppression and Lightning Warning Systems. Additionally we offer engineering and design services, installation services and educational courses all of which are available coast to coast and internationally. Contact us today to ensure your facility is protected. Headquarters Phoenix, Arizona Denver, Colorado Lyncole 90 Cutler Drive North Salt Lake, UT 84054 T. 800.825.1948 F. 801.292.4164 www.vfcinc.com www.z-pen.com www.lightningwarning.net 425 South 48th Street Suite 110 Tempe, AZ 85281 T. 480.966.0175 F. 480.966.0184 1500 West Hampden Ave Suite 4J Sheridan, CO 80110 T. 303.649.4905 F. 303.649.4906 3547 Voyager Street Suite 204 Torrance, CA 90503 T. 800.962.2610 F. 310.214.1114 www.lyncole.com www.lightningwarning.net Hamilton, New Jersey 200 Whitehead Road Bldg A Suite 114 Hamilton, NJ 08619 T. 609.781.0382 F. 817.488.4757 Dallas, Texas 1240 Texan Trail Suite 108 Grapevine, TX 76501 T. 817.488.4788 F. 817.488.4757 Raleigh/Durham, North Carolina 112-A Wheaton Drive Youngsville, NC 27596 T. 919.556.0685 F. 919.556.0636 Chicago, Illinois Local Installer T. 847.707.6736 Atlanta, Georgia Local Installer T. 210.347.4671 San Antonio, Texas Local Installer T. 210.268.5087 page 10