lighting management standalone sensors installation details Ceiling mounting All sensors have built-in bracket systems that enable ceiling mounting. Most sensors are suitable for standard EU boxes (Ø65). This is important for applications where the ceiling is unavailable for sensor installation Only one Cat. No. for two ways of mounting Wall mounting Wall mounting sensors are supplied with mounting base Simply fi x base to the wall, connect wires to the automatic wiring block and fi x sensor to base Settings Most sensors feature Smart Factory Set technology Adjustments are typically not needed after installation If adjustments need to be made (due to last minute changes in furniture or fi xture placement), sensitivity and time delays should match the activity levels of the monitored spaces Two commissioning tools can be used to adjust settings : For standard configuration : - Time level : 3, 5, 10, 15, 20 mn - Lux level : 20, 100, 300, 500, 1000 lux - Presence, presence walkthrough, absence modes - PIR and US detection sensibility : low, medium, high, very high - test mode Presence mode 3' Walkthrough mode Cat. No. 0882 35 (see p. 83) Absence mode For advanced configuration : This commissioning tool enables a very precise commissioning of your sensors : - Time : from 0 seconds to 60 mn - Lux : from 1 lux to 1275 lux - Detection mode : presence, presence walkthrough, absence modes - PIR and US detection sensibility : low, medium, high, very high - Provides access to advanced functions such as calibration, alarms, choice of mode of detection (initial detection, maintain detection, retrigger), daylight function - Allows downloading, saving and duplication of sensor parameters Cat. No. 0882 30 (see p. 83)
Room controller (2 outputs) The room controller is a key component of the lighting control system. It provides low voltage power to SCS sensors Several sensors can be linked (up to 10). Only one Cat. No. for several applications 0488 20 Product features > Screw terminal block > Auxiliary input for manual control by simple push > 1 RJ 45 input for SCS sensors > 16 A outputs for lighting and fan 0488 22 0488 21 Wiring accessory Wiring accessory Example of installation - example of a 400 m 2 premises Office 1 Hall Office 2 s Archives Offi ce Infrared 45 m 2 Meeting room Dual-tech 90 m 2 Lighting accounts for up to 20% of a commercial building's electricity use Meeting room Archives Hall Workshops Warehouses Ultrasonic 45 m 2 Workshops/Warehouses switches connected to push buttons Deliberate switch-on / automatic switch-off Example of a 400 m 2 public building or work premises with self-contained detectors and controllers (public spaces with capacity for 50 or more people) Exhibition hall Office 1 Office 2 Office 3 Work premises 3 offi ces regulated by self-contained ON-OFF detection - 1 output Infrared 360 Public building Exhibition hall Unit and detector linked to push buttons : Deliberate switch-on / automatic switch-off Possibility of illuminated push button with LED (accessibility regulations) Showroom Lighting controls can provide energy savings of 30% to 55% Showroom DALI controller Cat. No. 0488 51 DALI controller Cat. No. 0488 51 ON-OFF controller Cat. No. 0488 50 Window Dual-tech detector Cat. No. 0488 22 Ultrasonic detector Cat. No. 0488 21 Infrared detector (PIR) Cat. No. 0488 20 85
lighting management BUS/KNX system installation supervision Operating principle of the IP communication module Cat. No. 0035 43 Operating principle of the supervision gateway Cat. No. 0035 44 LAN Cat. No. 0488 84 Measurement control unit 97
lighting management Radio/ZigBee sensors and remote control devices No 1 : also using a BUS/SCS infrastructure BUS/SCS interface - Radio/ZigBee Cat. No. 0488 32 BUS/SCS infrastructure with DALI BUS/SCS controller 4 outputs Cat. No. 0488 44 Infrared sensor 45 m² Cat. No. 0488 20 Extension block with Radio/ZigBee 2-way control. Cat. No. 5738 34 : lighting, and computer Cat. No. 5738 24 Where an offi ce is fi tted out completely in glass and the BUS/SCS cannot drop vertically, a wireless Radio/ZigBee control unit can be installed at the door. At the same time in the extension block, a 230 V Radio/ZigBee control unit will allow offi ce lighting to be controlled and will allow this to be switched on and off from the PC No 2 : using only Radio/ZigBee Source Sensor 230 V Detection field 180 m² Cat. No. 0488 14 230 V Source Cat. No. 5738 34 Cat. No. 5738 34 The new thermal regulation recommendations are that a manual on-switch and an automatic cut-off will provide an even bigger saving (55%) In a building renovation for example, if a large area is fi tted with selfcontained presence sensors but the vertical connection cannot be made with its control points, Radio/ZigBee wireless control units will be installed 99
building management active building management BUS/KNX active building management with several Legrand or other systems + 1st example : Active building management with the building manager viewer Cat. No. 0490 00 or 0490 04 for display, analysis and alarms 2nd example : Active building management with the building manager viewer Cat. No. 0490 00 or 0490 04 + building manager controller Cat. No. 0035 44 for interoperability between the various connected systems : - Legrand solutions : lighting management, lighting, power measurement, fi re alarms - Other solutions : HVAC, etc. Example : Lighting management + lighting + power measurement + fire alarm BUS/KNX KNX IP ler IP/KNX gateway Cat. No. 0035 43 BACNET Management interface for units MODBUS IP BUS RS 485 RS 485/IP converter DPX 3 MCB ler Measurement control unit Electricity meter Touch screen 101