Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, , China

Similar documents
TEST REPORT IEC Safety of household and similar electrical appliances Part 2: Particular requirements for massage appliance

HISTORICAL OF SAMPLE RECEIVED EXAMINED SECTIONS

TEST REPORT IEC Safety of household and similar electrical appliances

RECOGNIZED COMPONENT Constructional Data Report (CDR)

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd. FCC MPE REPORT

TEST REPORT IEC Self-Ballasted LED-Lamp for general lighting services by voltage > 50V Safety specifications. See the cover page.

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

VERIFICATION STATEMENT EN :2006/ A1:2013+A12:2014 Part 1: General requirements for basic safety and essential performance

K-SQ13, KA-SQ13, K-SQ14, KA-SQ14, KO-SQ13, KOA-SQ13, KO-SQ14, KOA-SQ14, K-SQ13C, KA-SQ13C, K-SQ14C, KA- SQ14C, KO-SQ13C, KOA-SQ13C, KO-SQ14C,

UL TEST REPORT AND PROCEDURE

TEST REPORT PPP 11023A:2011 Rev. 00 TUV SUD Test report for T8/T5 LED tube Lamp

UL TEST REPORT AND PROCEDURE

Listing Constructional Data Report (CDR)

Test Report issued under the responsibility of:

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Model No.: VS806-6N ( ) V~ 50/60Hz LED 6x4W

C E R T I F I C A T E O F C O M P L I A N C E

Test report. ifesesws^ Date: Number: T /17 Project file: C Pages: Product: Fixed general purpose LED luminaire

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Safety of household and similar electrical appliances

Listing Constructional Data Report (CDR)

GUANGDONG XINYU TECHNOLOGY INDUSTRIAL CO., LTD

SPECIFICATION FOR APPROVAL

UL TEST REPORT AND PROCEDURE

SPECIFICATION FOR APPROVAL

Report Reference No...:

IEC60601_1J. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Test Report issued under the responsibility of:

RE-PR3-E-27 3-Phase Panel Mount 27kW

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

AS/NZS IEC :2013

Report No.: F690501/RF-SAF Testing location:

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC60529 Edition TD990426C02

Additional deviations may possibly be found if a complete type test is carried out on the product.

SOUTH AFRICAN NATIONAL STANDARD

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

No. KM First Issued: 23/03/1998 Latest Issue: 11/08/2010 Page 5 of 9

Technical-Report for SL Lamp 5 W

Modified Clauses of EN /A1:2004

HISTORICAL OF SAMPLE RECEIVED

Operating Instructions

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD NORME INTERNATIONALE

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

The product and any acceptable variation thereto is specified in the Annex to this certificate and the documents therein referred to.

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address...:

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

CE marking & your legal obligations

Refrigerating Appliance ErP Test Report

Annubar Flowmeter Series

M5800 Pressure Transducer with Rotatable Display

Quality Underfloor Heating

This is a preview - click here to buy the full publication ICS ISBN

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Tank Gauging System Special Safety Instruction

Certification Supplement Manual

HTC-915-CONT. Heat-Trace Control system

INSTRUCTION MANUAL (ATEX / IECEx)

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore Singapore

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

INTERNATIONAL STANDARD

Door Release Power Supply

TEST REPORT ON THE SAFETY OF ELECTRICAL EQUIPMENT FOR PRODUCT INNOVATORS LTD ON A INFRARED TANKLESS HOT WATER SYSTEM

HYTEK ATEX APPROVED TANK ALARM

M5800 Pressure Transducer with Rotatable Display

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

Delta Electronics Corp. APPROVAL SHEET PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE-ARRANGMENT.

Table of Content LT 5165-UL

LICENCE. to use the European Mark. Licence No Date of issue: Wien, Rev. No. 01 Wien,

Independent, accredited testing station Member laboratory of STL and LOVAG

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Certification Supplement Manual

BS EN : A2:2015 used in conjunction with BS EN : A11:2014 and BS EN 62233:2008

Model Name: FHS-A6025B01. Application: Intel Nehalem Socket U Xeon (45nm) W5500/X5500/E5500/L5500 CPU sequence. Pictures

LED DRIVER NEW PRODUCT CATALOGUE Edition V1.0 SHEN ZHEN MOSO ELECTRONICS TECHNOLOGY CO.,LTD

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Certificate of Compliance

Overload relays. General descriptions. Configuration of the front

PolyGard 2-channel Gas Controller MGC-03

MBCE-110/230UV Flame Sensor Module

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

USB CONNECTORS MINI USB CONNECTOR & CABLE ESB3,4,5 SERIES. USB CONNECTOR & CABLE ESB0 SERIES (Connector) ESB1 SERIES (Cable)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Victoreen Primalert 35 Area Radiation Monitor

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD. COPY OF MARKING PLATE

Transcription:

Applicant : Xiamen Comfort Science & Technology Group Co., Ltd 18 Long Shan South Road, Xiamen, Fujian Province, 361009, China Attn. to: Ms. Shen Manufacturing location : Zhangzhou Easepal Industrial Co., Ltd 228 Jiao Song Road, Long Chi Industrial Zone, Zhangzhou, Fujian, China Test object / Model : Switching Power Supply / EP-U-1220-EU, EP-U-1220-UK Test specifications / Test standard : EN 61558-2-16:2009 (Used in conjunction with EN 61558-1: + A1:2009) Purpose of examination : Test according to the test specification. Inspection of the compliance with protective objectives of the following EC Directives: - 2006/95/EC. Test result : In the opinion of SGS-CSTC the presented unit was found to be in compliance with the test specification. Remark : The EU plug was evaluated according to EN 50075: 1990. The UK plug was evaluated according to BS 1363-1:1995 +A1 +A2 +A3. This test report includes: Annex 1: 5 pages of EU Plug test. Annex 2: 8 pages of UK Plug test. Summer Xia Holon Li Project Manager Project Engineer Safety Laboratory This document is issued by the Company subject to its General Conditions of Service, available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company s findings at the time of its intervention only and within the limits of Client s instructions, if any. The Company s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be produced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 1 of 21

1. Function / Description : Switching Power Supply Both models are totally the same except for model No. and plug portion. 2. Ratings : Model : Rated Input : Rated Output : EP-U-1220-EU, EP-U-1220-UK 200-240 VAC, 50/60 Hz, 0,3 A 12 Vd.c., 1,6 A Type of transformers Safety insolating transformer Application portable Protection against electric shock Class II Short-circuit protection -- inherently short-circuit proof Yes non-inherently short-circuit proof No non short-circuit proof No fail safe : No Protection index IP20 Other characteristics Continuous operation Rated ambient temperature ta ( C) 25 Short-circuit voltage (V) -- Supply connection : Direct plug-in 3. Test : The test was done in the Electrical Safety Laboratory of SGS-CSTC in Guangzhou. 20 samples were submitted for tests on 2011-02-24. Tests were performed from 2011-03-10 to 2011-03-26. Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 2 of 21

Test Result: Clause Requirement + Test Result - Remark Verdict 8 Marking and other information See making plate P 9 Protection against electric shock P 10 Change of input voltage setting N 11 Output voltage and output current under load (see appended table) P 12 No-load output voltage (see appended table) P 13 Short-circuit voltage N 14 Heating (see appended table) P 15 Short-circuit and overload protection (see appended table) P 16 Mechanical strength P 17 Protection against harmful ingress of water and moisture 18 Insulation resistance and electric strength P 19 Construction P 20 Components (see appended table) P 21 Internal wiring P 22 Supply connection and external flexible cables and cords 23 Terminals for external conductors P 24 Provision for protective earthing N 25 Screws and connections N 26 Creepage distances and clearances P 27 Resistance to heat, fire and tracking P 28 Resistance to rusting N E ANNEX E, GLOW WIRE TEST P F ANNEX F, REQUIREMENTS FOR MANUALLY OPERATED SWITCHES WHICH ARE PARTS OF THE TRANSFORMER H ANNEX H, ELECTRONIC CIRCUITS (see appended table) P K ANNEX K, INSULATED WINDING WIRES FOR USE AS MULTIPLE LAYER INSULATION U ANNEX U INFORMATIVE OPTIONAL TW MARKING FOR TRANSFORMERS IP20 P P N N N Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 3 of 21

Clause Requirement + Test Result - Remark Verdict V ANNEX V, SYMBOLS TO BE USED FOR THERMAL CUT-OUTS Remark: Test case does not apply to the test object: N (not applicable) Test object does meet the requirement: P (pass) N 11 and 12 TABLE: OUTPUT VOLTAGE AND OUTPUT CURRENT UNDER LOAD; NO-LOAD OUTPUT VOLTAGE Clause 11 12 /rated output/ rated voltage (V) sec. voltage (V) delta Usec (%) Usec V no-load output delta Usec no-load output % further information P 12 Vd.c., 1,6 A 12 Vd.c. 12 Vd.c., 1,6 A 12 Vd.c. 11,7 Vd.c. 11,7 Vd.c. - 2,6 % 12,04 Vd.c. + 3,3 % Input: 200 V~ - 2,6 % 12,04 Vd.c. + 3,3 % Input: 240 V~ 14 TABLE: HEATING P /rated output r-cold Ω ambient temperature ( C)... : 25,3 C -- r-warm Ω temp. C ext. encl. C support C int. + ext. wire further information 12 Vd.c., 1,6 A -- -- 75,7 47,2 29,2 43,1 Input: 180 V~ 12 Vd.c., 1,6 A -- -- 76,8 47,0 28,8 41,4 Input: 264 V~ 15 TABLE: SHORT-CIRCUIT AND OVERLOAD PROTECTION P /rated output r-cold Ω ambient temperature ( C)... : 25,8 C -- r-warm Ω temp. C ext. encl. C support C int. + ext. wire further information 12 Vd.c., 1,6 A -- -- 147,0 77,9 37,2 69,2 Input: 180 V~ Overload at 2,6 A 12 Vd.c., 1,6 A -- -- 126,0 65.,9 33,9 56,1 Input: 264 V~ Overload at 2,9 A 20 TABLE: LIST OF CRITICAL COMPONENTS AND MATERIALS P Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 4 of 21

Component Manufacturer /Trademark Primary lead Various 1007 20 AWG, 80 C, 300 V Output lead Various 2725,1185, 2468, 2464 Heat shrinkable tube Fuse (FUSE) SHENZHEN WOER HEAT- SHRINKABLE MATERIAL CO LTD XC Electronics (Shen Zhen) Co., Ltd. Dongguan Better Electronic Technology Co., Ltd. Conquer Electronic Technology Co., Ltd Walter Electronic Co., Ltd. Type/Model Technical Data 2) Standard Approval/ Reference 1) RSFR 20 AWG, 80 C, 300 V VW-1, 125 C, 600 V 3T-Serie(s) T2AL, 250 VAC EN 60127-1: 2006 -- UL -- UL -- UL (E203950) EN 60127-3: 1996/A2:2003 334 T2AL, 250 VAC EN 60127-1: 2006 EN 60127-3: 1996/A2:2003 PTU T2AL, 250 VAC EN 60127-1: 2006 EN 60127-3: 1996/A2:2003 ICP T2AL, 250 VAC EN 60127-1: 2006 EN 60127-3: 1996/A2:2003 Hollyland Co., Ltd. 30TS T2AL, 250 VAC EN 60127-1: 2006 VDR (MOV) Brightking (shenzhen) Co., Ltd. Shantou High-New Technology Dev. Zone Songtian Enterprise Co., Ltd. 471KD07 AC 470V, 1750 A, 8/20 us, 40/085/56 STE- 07D471K AC 470V, 1200 A, 8/20 us, 40/085/21 EN 60127-3: 1996/A2:2003 IEC 61051-1: 2007 IEC 61051-2: IEC 61051-2-2: IEC 61051-1: 2007 IEC 61051-2: IEC 61051-2-2: (40019614) (40025428) (40001462) (40012824) (40011830) (40027827) (40023049) Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 5 of 21

X-cap. (CX1) Y-cap. (CY1, CY2) Xiamen Wanming Electronics Co., Ltd. Xiahua Advanced Sensitive Hongzhi Enterprises Ltd. Ultra Tech Xiphi Entreprise Co., Ltd. Xiamen Wanming Electronics Co., Ltd. Shantou High-new Technology Development Zone Songtian Enterprise Co., Ltd. Tenta Electric Industrial Co., Ltd. Liaoning Diya Capacitor Co., Ltd. Shenzhen Su Rong Capacitors Co., Ltd. Nanjing Yuyue Electronics Co., Ltd. 07D471K AC 470V, 1750 A, 8/20 us, 40/085/56 FNR- 07K471 HEL- 07D471K AC 470V, 1200 A, 8/20 us, 40/085/56 AC 470V, 1750 A, 8/20 us, 40/085/56 HQX 275 VAC, 0,22 μf, 40/100/21/C, X2 WPX, MPX, HQX, UTX 275 VAC, 0,22 μf, 40/110/56/C, X2 MPX 275 VAC, 0,22 uf, 40/110/56/B, X2 MEX 275 VAC, 0,22 uf, 40/100/21/C, X2 MKP-X2 275 VAC, 0,22 uf, 40/100/21/C, X2 MPX/MKP 280 VAC, 0,22 uf, 40/100/21/C, X2 Series CT7 4700pF, 250Vac, 25/125/21/C, Y2 IEC 61051-1: 2007 IEC 61051-2: IEC 61051-2-2: IEC 61051-1: IEC 61051-2: IEC 61051-2-2: IEC 61051-1: IEC 61051-2: IEC 61051-2-2: (40027412) (40008242) (40008621) (40024534) (40023119) TUV (R 50136379) (119119) (40019857) (40008924) (40008013) Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 6 of 21

Optocoupler (PH1) Xiamen Wanming Electronics Co., Ltd. Zonkas Electronic Co., Ltd. Shaanxi Huaxing Electronic Development Co., Ltd. Shantou High-new Technology Dev. Zone Songtian Enterprise Co., Ltd. Everlight Eletronics Co., Ltd Bright Led Electronics Corp. HM-Series ZE CT7 CE-Series EL817 BPC 817 4700pF, 250Vac, 25/85/21/C, Y2 4700pF, 300Vac, 25/125/21/C, Y2 4700pF, 400Vac, 40/85/21/C, Y2 4700pF, 250Vac, 25/125/21/C, Y2 Int. CR / Ext. CR / Dti. >7,6 mm / >7,6 mm / >0,4 mm, 55/110/21 Int. CR / Ext. CR / Dti. >7,6 mm / >7,6 mm / >0,4 mm, 30/100/21 Sharp Corporation PC817 Int. CR / Ext. CR / Dti. (mm) 6,4 / 6,4 / > 0,4 Line filter (LF1) Lite-On Technology Corporation XIAMEN TONG KUN INDUSTRY & TRADE CO., LTD. -- bobbin CHANG CHUN PLASTICS CO LTD LTV-817 Int. CR / Ext. CR / Dti. 6,5 mm / 6,5 mm / >0,4 mm UU9.8 N1, N2: Ф0,23 mm / 110T EN 60747-5-2: 2003 EN 60747-5-2: 2003 EN 60747-5-2: 2003 EN 60747-5-2: 2003 EN 61558-2- 16:2009 (Used in conjunction with EN 61558-1: + A1:2009) (40000263) (40020372) (133203) (40025748) (132249) (40007240) (40008087) (40015248) Tested with appliance T375H 150 C, V-0 -- UL (E59481) Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 7 of 21

Transformer (TR) Zhang Zhou easepal Industrial Co., Ltd. -- bobbin CHANG CHUN PLASTICS CO LTD --Insulation tape CHANG SHU LIANG YI TAPE INDUSTRY CO LTD -- alt. Insulation tape -- alt. Insulation tape --TIW (Sec. winding) --alt. TIW (Sec. winding) --alt. TIW (Sec. winding) --alt. TIW (Sec. winding) JIANGSU YONGLONG GLUE INDUSTRY CO LTD JINGJIANG YAHUA PRESSURE SENSITIVE GLUE CO LTD CHANGYUAN ELECTRONICS (SHENZHEN) CO LTD DAH JIN TECHNOLOGY CO LTD TA YA ELECTRIC WIRE & CABLE CO LTD E&B TECHNOLOGY CO LTD BCK- PQ2016-02 PQ2016 Pri. winding: NP1: Ф0,30 mm / 42T NP2: Ф0,30 mm / 42T NB: Ф0,27 mm / 16T EN 61558-2- 16:2009 (Used in conjunction with EN 61558-1: + A1:2009) Tested with appliance T375J 150 C, V-0 -- UL (E59481) LY-xx YL-168 PZ, CT CB-TIW TLW-B TILW-B E&B-XXXB Min. 2 layers, 130 C Min. 2 layers, 130 C Min. 2 layers, 130 C 130 C (Class B), 600V, Ф0,45 mm / 11T 130 C (Class B), 1,4kV, Ф0,45 mm / 11T 130 C (Class B), 1kV, Ф0,45 mm / 11T 130 C (Class B), 1kV, Ф0,45 mm / 11T PWB Various Various V-0, min. 105 C Insulation sheet under power board Insulation tape in heat sink CHANGZHOU ISOVOLTA ELECTRICAL INSULATION MATERIALS LTD CHANG SHU LIANG YI TAPE INDUSTRY CO LTD -- UL (E246820) -- UL (E306163) -- UL (E165111) -- UL (E249037) -- UL (E236542) -- UL (E225803) -- UL (E315265) -- UL MP V-0, 130 C -- UL (E196078) LY-xx Min. 2 layers, 130 C -- UL (E246820) Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 8 of 21

Pin holder (EU) Pin holder (UK) JINGJIANG JINGYI ADHESIVE PRODUCT CO LTD Zhang Zhou easepal Industrial Co., Ltd. Zhang Zhou easepal Industrial Co., Ltd. JY25-A EP-U-1220- EU EP-U-1220- UK Min. 2 layers, 130 C -- UL (E246950) -- EN 50075:1990 Tested with appliance -- BS 1363-1:1995 +A1 +A2 +A3 Tested with appliance Enclosure XIAMEN JAU WEI PLASTICS CO LTD J01F02B V-0, 60 C, ABS/PC -- UL (E255636) 1 ) An asterisk indicates a mark which assures the agreed level of surveillance. 2 ) Description to include adjacent markings for critical fuse/s. Annex H TABLE: ELECTRONIC CIRCUIT TEST P Component No. Ambient temperature ( C)... : 25,0 -- Power source for EUT: Manufacturer, model/, output rating... : Fault Supply voltage (V) Test time Fuse # Fuse current (A) -- -- Observation EC4 s-c 180 -- -- -- Circuit protected immediately. No EC4 s-c 264 -- -- -- Circuit protected immediately. No D7 s-c 180 -- -- -- Circuit protected immediately. No D7 s-c 264 -- -- -- Circuit protected immediately. No PH1 s-c c/e 180 -- -- -- Circuit protected immediately. No PH1 s-c c/e 264 -- -- -- Circuit protected immediately. No PH1 s-c diode 180 -- -- -- Circuit protected immediately. No Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 9 of 21

PH1 s-c diode 264 -- -- -- Circuit protected immediately. No Q1 s-c d/s 180 -- -- -- Circuit protected immediately. No Q1 s-c d/s 264 -- -- -- Circuit protected immediately. No Q1 s-c d/g 180 -- 2 7,2 Q1, R9, R10, R11,R12 broke immediately. Fuse FUSE opened immediately. No Q1 s-c d/g 264 -- 2 9,3 Q1, R9, R10, R11,R12 broke immediately. Fuse FUSE opened immediately. No Q1 s-c s/g 180 -- 2 7,1 Q1, R9, R10, R11,R12 broke immediately. Fuse FUSE opened immediately. No Q1 s-c s/g 264 -- 2 9,0 Q1, R9, R10, R11,R12 broke immediately. Fuse FUSE opened immediately. No EC1 s-c 180 -- 2 7,2 Fuse FUSE opened immediately. No EC1 s-c 264 -- 2 9,4 Fuse FUSE opened immediately. No D2 s-c 180 -- 2 7,2 Fuse FUSE opened immediately. No D2 s-c 264 -- 2 9,4 Fuse FUSE opened immediately. No Output s-c 180 -- -- -- Circuit protected immediately. No Output s-c 264 -- -- -- Circuit protected immediately. No Remark: Dielectric strength test after heating test, Pass Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 10 of 21

4. Photo document EP-U-1220-EU [ x ] general See making plate [ ] Internal EP-U-1220-EU [ x ] general [ ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 11 of 21

EP-U-1220-EU [ x ] general [ ] Internal EP-U-1220-EU [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 12 of 21

EP-U-1220-EU [ x ] Internal EP-U-1220-EU [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 13 of 21

EP-U-1220-EU [ x ] Internal EP-U-1220-EU [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 14 of 21

EP-U-1220-UK [ x ] general See making plate [ ] Internal EP-U-1220-UK [ x ] general [ ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 15 of 21

EP-U-1220-UK [ x ] general [ ] Internal EP-U-1220-UK [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 16 of 21

EP-U-1220-UK [ x ] Internal EP-U-1220-UK [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 17 of 21

EP-U-1220-UK [ x ] Internal EP-U-1220-UK [ x ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 18 of 21

PWB [ X ] top [ ] Internal PWB [ X ] bottom [ ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 19 of 21

EP-U-1220-EU, marking plate [ ] Internal EP-U-1220-UK, marking plate [ ] Internal Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 20 of 21

NOTES TO THIS TEST REPORT 1. The following language(s) of marking(s) and instruction sheets were submitted during the test application: English According to the standard, instruction sheets and other texts required by the standard should be written in the official language(s) of the country in which the product is to be sold. The applicant should ensure that the product in future production fulfils the receptive standard requirements. 2. The components performed satisfactorily during testing and are considered to be suitable for use in the sample tested. Acceptances of the safety critical components and materials were based on: the certification record(s) and/or test report submitted by the applicant; or component / material tested with the appliance Detail shall be referred to the component list on the appendix of this test report. 3. Plug (and socket) used in this product must be compiled with the local plug and socket regulation of the respective country. - - - End of Report - - - Tel: +86 20 8215 5555 Fax: +86 20 8207 5058 Page 21 of 21