CORRECT ENDOSCOPE REPROCESSING

Similar documents
ENDOSCOPE DECONTAMINATION : Where are we now!

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

Product Catalogue 2016

2015 Myco Industries, Inc Fax:

INSTRUCTIONS EVIS EXERA II DUODENOVIDEOSCOPE

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

SOLUSCOPE SERIES 3 DESIGNED WITH THE FUTURE IN MIND FEATURES FLEXIBLE ENDOSCOPE DISINFECTOR / STERILISER

Attendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.

Flexible endoscope automated reprocessing system

OLYMPUS AMERICA, INC. ENDOSCOPE GROUP TWO CORPORATE CENTER DRIVE MELVILLE, NEW YORK TEL (631) March 3, 2003

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

Caution: Federal U.S. law restricts this device to sale by or on the order of a physician.

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

When you sterilize an instrument set, you know what the standards are.

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

INSTRUCTIONS EVIS EXERA GASTROINTESTINAL VIDEOSCOPE

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

ARES flexible endoscope automated reprocessing system

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

Planning for the optimal sluice room

Classification of Instruments -

Fujinon Medical Hygiene. Reprocessing of flexible endoscopes and endoscopic accessories.

minietd2 the small reprocessor with the big performance.

Getinge 600 series Top-loaded flusher-disinfectors

I.F.U Re/Processing Reusable Medical Devices

Accurately With HSE COP PT 1 5

Housekeeping and Laundry Ulrika Ransjö

Always ensure that surfaces that are being disinfected are compatible with the product being used.

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

VET /2018-E VETPUMP 2. Precision Suction & Irrigation System

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

The Principles, The Process, and The Results:

SteelcoSure Independent performance verification of your equipment and processes

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

CER-1 / CER-2 (MV-1 / MV-2) (CLM-5001X / CLM-5002VX)

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

OPERATION MANUAL. (Cleaning, Disinfection and Storage) Endoscope ED-530XT

CLEANING INSTRUCTIONS

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

CLEANING OF INSTRUMENTS

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Aesculap Implant Systems

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

GETINGE WD15 CLARO 1 GETINGE WD15 CLARO THE CLEAR CHOICE IN WASHER-DISINFECTORS. Always with you

EG-2990i, EG-2790i EG-1690K, EG-2490K EG-2790K, EG-2990K EG-3490K, EG-3890TK EG27-i10, EG29-i10

PROFESSIONAL USER GUIDELINES FOR PRACTICE INFECTION CONTROL AND HYGIENE IN COMPANION ANIMAL VETERINARY CLINICS/HOSPITALS

Tornado Flusher disinfector

Manual. Reprocessing. RICHARD WOLF Heat-Sensitive Instruments. GA-J050 / en / V7.0 / PDI

TBJ Model SPCS B Scope Pre-Cleaning Sink. Product Specification. Product Description

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

Ultrasonic From delicate microsurgery instruments to heavy duty sets

Device Reprocessing Checklist Scoring Matrix 1=low 5=high

Sterling P1500 Washer-Disinf ec t or Acce s s or y Guide

Data of 57 hospitals** Estimated for England and Wales

2. Push the drain connector into the disinfectant removal port until it clicks.

Dealing with water shortages

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

Getinge WD14 Tablo Tabletop washer-disinfector

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Getinge WD15 Claro Washer-disinfector

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

4/8/2014 GOAL PATIENT EQUIPMENT

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

AMITY INTERNATIONAL (U.K.)

A new wave in automated instrument washing and disinfection Introducing the new HYDRIM G4 WD series

STERIS Instrument Cleaning Chemistries

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

Instructions for Use (GA16)

AF2 PROFESSIONAL LINE. Washer disinfector for human waste containers. Your Health, our Technology

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

Scottish Health Technical Memorandum 2030 (Part 2 of 3) Design considerations. Washer-disinfectors

Welcome to Section F, Application of Cleaning, Disinfection, and Sterilization Principles to Patient Equipment. This is the sixth of seven modules in

Processing Instructions. Cleaning so easy.

Getinge 600 series Top-loaded flusher-disinfectors

Guidance on Environmental Requirements for Minor Surgery in General Practice

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Infection Prevention and Control N/A. Executive Director of Nursing and Quality, DIPC. IPC Governance Meeting Members

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Flusher disinfectors for hospitals and nursing houses

THE BASICS OF DECONTAMINATION

Scottish Health Planning Note 13. Part 2 Decontamination Facilities: Local Decontamination Units

ProFormanceTM Cleaning Verification Products

Transcription:

CORRECT ENDOSCOPE REPROCESSING Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham HIRL Birmingham 1

Inadequate decontamination procedures and equipment malfunction were two leading causes of post endoscopic infection and contamination. More than 91% of the infections could be prevented if quality control systems were improved Kovaleva J et al Clin Microbiol Rev 2013;26(2):231-54 HIRL Birmingham

Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy TYPE OF FLEXIBLE ENDOSCOPIES No. of REPORTED INFECTIONS/ OUTBREAKS REASONS FOR FAILURE BRONCHOSCOPY 51 Inapprpopriate cleaning and disinfection povidone iodine Contaminated AER Incorrect connectors Rinsing with tap water Hole in the endoscope sheath (no leak testing) ERCP Endoscopic Retrograde Cholangio Pancreaticography UPPER GASTROINTESTINAL ENDOSCOPY 23 Inapprpopriate cleaning and disinfection povidone iodine, cetrimide Contaminated AER Incorrect connectors Failure to irrigate all channels Rinsing with tap water Contaminated water bottle 19 Inapprpopriate cleaning and disinfection povidone iodine Contaminated AER Incorrect connectors Rinsing with tap water Hole in the endoscope sheath (no leak testing) SIGMOIDOSCOPY & COLONOSCOPY HIRL Birmingham 5 Inapprpopriate cleaning and disinfection povidone iodine, BKC, cetrimide Contaminated AER Incorrect connectors Contaminated water bottle Biopsy forceps not sterilized Kovaleva J et al Clin Microbiol Rev 2013;26(2):231-54

HIRL Birmingham 4

DECONTAMINATION OF FLEXIBLE ENDOSCOPES Meticulous cleaning Proper immersion in disinfectant Thorough rinsing after disinfection Endoscope Washer Disinfectors are the preferred option HIRL Birmingham 5

ENDOSCOPE DECONTAMINATION PROBLEMS Instruments and accessories are expensive Damaged by heat and pressure Complex, difficult to clean and dry Penetration of channels uncertain Rapid throughput Risk of recontamination during final rinse from water supply/ewd HIRL Birmingham

ENVIRONMENT DESIGN AND LAYOUT Designated and dedicated decontamination area Separate dirty, clean and storage areas One-way flow for equipment Suitable facilities for manual cleaning Dedicated hand wash basin HIRL Birmingham

ENDOSCOPE CHANNELS HIRL Birmingham

DECONTAMINATION STAGES Pre clean at patient bed side Leak test Manual clean Endoscope Washer Disinfector Storage HIRL Birmingham

HIRL Birmingham CLEANING

PRE CLEANING At point of use Air/water channel External surfaces Suction channel Manufacturers instructions are essential HIRL Birmingham

MANUAL CLEANING At the sink in dedicated decontamination room Brushing Flushing Single use brushes must be used for cleaning at all times (UK recommendation) Staff must ensure meticulous adherence to manufacturers instructions for cleaning Important to ensure Access to all channels whether they have been used or not e.g. forceps raiser channel, auxiliary water channel Irrigation of all channels that cannot be brushed HIRL Birmingham

HIRL Birmingham DISINFECTANTS

ENDOSCOPE DISINFECTANTS Glutaraldehyde Peracetic acid Chlorine dioxide Superoxidised water OPA Etc, etc. HIRL Birmingham 14

DISINFECTANTS AND ENDOSCOPE DECONTAMINATION Ensure disinfectant has broad spectrum of antimicrobial activity is compatible with instruments and processing equipment is used at effective concentration is in contact with all surfaces HIRL Birmingham 15

CHANNEL IRRIGATION DEVICES HIRL Birmingham 16

HIRL Birmingham 17

ENDOSCOPE DECONTAMINATION : POTENTIAL PROBLEMS Disinfectant Spectrum of activity Over use Water quality Bacterial contamination Chemical contamination Training Accessories e.g. water bottle, biopsy forceps HIRL Birmingham 18

HIRL Birmingham 19

HIRL Birmingham 20

BACTERIA FREE WATER Cystoscopes Bronchoscopes ERCP Potential for infection and/or misdiagnosis of infection HIRL Birmingham 21

HIRL Birmingham 22

ENDOSCOPE WASHER DISINFECTORS The WD440 machines: Single chamber Twin chamber (independent operated) HIRL Birmingham 23

ENDOSCOPE WASHER DISINFECTORS : PROBLEMS Disinfectant concentration Machine contamination Water quality Maintenance Validation HIRL Birmingham

ENDOSCOPE STORAGE Endoscopes which have been reprocessed by high level disinfection and have been left for periods >3 hours should be reprocessed. MDA DB2002(05) HIRL Birmingham 25

TRANSPORTATION Protection of endoscopes and the environment from contamination and/or possible damage Separation of dirty and clean endoscopes HIRL Birmingham

DOCUMENTATION Types:- Policies: Statement of intent e.g. We will Provide decontaminated endoscopes Procedures: Sets of instructions How policy is implemented e.g. How to decontaminate endoscopes Forms: Evidence that procedures are carried out. e.g. List of items processed Others: Info, Guidelines, standards etc HIRL Birmingham

STANDARD OPERATING PROCEDURES Purpose of SOPs SOP s are required for all tasks which could have an effect on the quality of the decontamination process SOP s Must clearly describe specific tasks Must be easy to understand Must change if the task changes Are an essential tool in training HIRL Birmingham

STAFF TRAINING HIRL Birmingham 29

STAFF TRAINING At induction and regular updates Anatomy/construction of endoscopes Use of washer disinfectors (if applicable) Traceability systems Importance of decontamination record keeping Records kept of individuals training Sufficient time allowed for training HIRL Birmingham 30

SUMMARY It is important to ensure that Staff receive comprehensive training Cleaning takes place prior to sterilization or disinfection All surfaces of the endoscope are exposed during the decontamination procedure An effective disinfectant is used at the correct concentration The final rinse does not re-contaminate the endoscope Testing, in accordance with national guidance, takes place and is audited HIRL Birmingham

THANK YOU FOR LISTENING HIRL Birmingham 32