ENHANCED FIRE PERFORMANCE CABLE

Similar documents
FIRE PERFORMANCE CABLE

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP200 GOLD

High Performance LSZH Fire Resistant Cable

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

FIRE RESISTANT CABLES FP400

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

FIRE RESISTANT CABLES FP300

fire resistant cables

FIRE RESISTANT CABLES

Introduction.

BS /1000V XLPE Insulation LSZH Sheath Cables

Total Fire Solutions. Includes BS 8519 and the updated BS :

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

LSOH Flexible Cables

LV FIRE RESISTANT CABLES

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

BS 6387: 1994 Specification for performance requirements for cables required to maintain circuit integrity under fire conditions.

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Fire Resistant Cables

Method of test defined in IEC for determining the circuit integrity performance of a cable under fire conditions.

Flame Retardant Overall Screened Instrumentation Cables (multicore)

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

STANDARDS INSTALLATION. Certificate No 077m

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Catalogue Telecommunication Cables INTRODUCCIÓN

Multi-Core Fire Resistant Cable

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Loss Prevention Certification Board. This is to certify. KLAXON SIGNALS LTO Wrigley Street, Oldham, Lancashire, OL4 1HW

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Telecommunication Cables

Caledonian Fire resistant Coaxial Cables

The Quality Connection. BETAflam Fire Resistant Safety Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Caledonian Flame Retardant Coaxial Cables

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Photovoltaic Cables EN H1Z2Z2-K

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

DNVGL-CP-0401 Edition February 2016

Catalogue Power Cables

Tratos Railway Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

DNVGL-CP-0399 Edition March 2016

Havells Fire Survival Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Catalogue. Instrumentation & Control Cables

THE TRUE FIRE SURVIVAL CABLE

DNVGL-CP-0402 Edition February 2016

INTERNATIONAL STANDARD

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Caledonian fire Resistant signal & Data cables

Guide to the Specification and Installation of Pyro Mi Wiring Cables

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

TYPE APPROVAL CERTIFICATE

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

PRODUCT CATALOGUE Norröna

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Cable technology for highest safety requirements

SPECIAL ELECTRICAL AND OPTICAL CABLES

Cablosam Tapes for Fire-Resistant Cables

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

Requirements for Electrical Installations

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Wires, Cables, Cords and Adhesive Tapes

Single core cables with reduced wall thickness

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

KUTERLEX & KUTERLEX PLUS PLASTIC COATED COPPER TUBE

Loss Prevention Standard

INTERNATIONAL STANDARD

Lloyd s Register Type Approval System Test Specification Number 3

Compact Module. Category 6A FTP Cabling System 1.1

BS 476: Part 7: 1997 on K-Flex IN Clad Foil. Prepared for: L'Isolante K-Flex Srl Via Leonardo da Vinci, RONCELLO (MB) Italy


Department for Communities and Local Government Research Report:

OIL & GAS INDUSTRY OTHER INDUSTRIES

NUAIRE POSITIVE INPUT VENTILATION SYSTEMS DRIMASTER-ECO LOFT MOUNTED POSITIVE INPUT VENTILATION SYSTEMS

LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB

Special Provision No. 683S28 December 2017

Transcription:

FIRE PERFORMANCE CABLE Manufactured to BS 7629-1 Table 1 Plain Annealed Copper Conductors / Silicone Rubber Insulated / Glass Fibre Tape / Tinned Copper Circuit Protective Conductor / Double Layer of Copper/Polyester Tapes / Thermoplastic Low Smoke Non-Halogen (LSNH) Sheath. 300/500V Conductor: Plain Annealed Copper 1 or 2 to BS EN 60228 Insulation: Silicone Rubber Type EI2 to BS EN 50363-1 Screen 1: Glass Fibre Tape Screen 2: Double Copper/Polyester Screen In Direct Contact With Tinned Annealed Copper CPC. Providing excellent Earthing Characteristics Sheath: Thermoplastic LSNH Type LTS 3 to BS 7655-6.1 Current Ratings: For current ratings refer to table 4D2 of BS7671 IEE Wiring Regulations Seventeenth Edition. These cables are suitable for both indoor and outdoor applications in suitably protected environments and is particularly appropriate for direct burial in plaster, clipped directly to surface, tray and other installations requiring a dressable product. STANDARD CORE COLOURS 2 CORE 3 CORE 4 CORE MINIMUM OPERATING TEMPERATURE -15 C MAXIMUM OPERATING TEMPERATURE 70 C MINIMUM BENDING RADIUS 6xØ The British Cable Company You Can Trust Millfields Industrial Estate, Arksey Lane, Bentley, Doncaster, DN5 0SJ, United Kingdom t: 01302 821700 f: 01302 821701 e: sales@doncastercables.com www.doncastercables.com

FIRE PERFORMANCE CABLE FIRE PERFORMANCE : BS 6387:2013 (Category C Resistance to fire alone, 3 hours at 950 ) BS 6387:2013 (Category W Resistance to fire with water spray) BS 6387:2013 (Category Z Resistance to fire with mechanical shock) IEC 60311-21 (950 C) IEC 60332-3-24 EN 50200:2015 (Enhanced 120) BS8434-2 (120 minutes) BS 5839-1 Clause 26.2e (Enhanced) Conductor Identification: Two Core - Blue and Brown (plus CPC) Three Core -Brown, Black and Grey (plus CPC) Four Core -Blue, Brown, Black and Grey (plus CPC) Recommended Clips and Clipping Distances: 2 Core 3 Core 4 Core Size (mm 2 ) 1.0 1.5 2.5 4.0 1.0 1.5 2.5 4.0 1.0 1.5 2.5 4.0 Recommended Clip 30 34 43 47 34 37 47 54 37 43 51 54 Maximum Horizontal Clipping Distance 250 300 300 300 300 300 300 300 300 300 300 350 Maximum Vertical Clipping Distance 400 400 400 400 400 400 400 400 400 400 400 450 Weight and dimensional information is provided as an approximate guide only. Sales Office: Millfield Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire, DN5 0SJ Tel: 01302 821700 Fax: 01302 821701 Email: sales@doncastercables.com

FIRE PERFORMANCE CABLE Dimensional Details: Reference Number Number and nominal cross sectional area of conductors (mm²) stranding of conductor Stranding of CPC radial thickness of insulation radial thickness of sheath Overall Diameter Approximate weight (kg/km) HFSP2C1.0 2 x 1.0 1/1.13 1 / 1.13 0.6 0.9 8.5 104 HFSP2C1.5 2 x 1.5 1/1.38 1 / 1.38 0.7 0.9 9.0 128 HFSP2C2.5 2 x 2.5 7/0.67 7/0.67 0.8 1.0 11.0 185 HFSP2C4.0 2 x 4.0 7/0.85 7/0.85 0.8 1.1 12.3 TBA HFSP3C1.0 3 x 1.0 1/1.13 1 / 1.13 0.6 0.9 9.0 TBA HFSP3C1.5 3 x 1.5 1/1.38 1 / 1.38 0.7 0.9 10.0 TBA HFSP3C2.5 3 x 2.5 7/0.67 7/0.67 0.8 1.0 12.5 251 HFSP3C4.0 3 x 4.0 7/0.85 7/0.85 0.8 1.1 13.3 TBA HFSP4C1.0 4 x 1.0 1/1.13 1 / 1.13 0.6 1.0 9.6 142 HFSP4C1.5 4 x 1.5 1/1.38 1 / 1.38 0.7 1.0 11.0 187 HFSP4C2.5 4 x 2.5 7/0.67 7/0.67 0.8 1.1 13.0 264 HFSP4C4.0 4 x 4.0 7/0.85 7/0.85 0.8 1.2 15.0 399 Weight and dimensional information is provided as an approximate guide only. Sales Office: Millfield Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire, DN5 0SJ Tel: 01302 821700 Fax: 01302 821701 Email: sales@doncastercables.com

FIRESURE PLUS BENEFITS FIRE PERFORMANCE CABLE Our Firesure Plus cable has at least twice as many copper tapes than any other leading Fire Performance Cable; some other enhanced fire performance cables even opt to use an aluminium tape (usually seen on standard fire performance cables). The Firesure Plus design also incorporates a glass fibre tape which covers the inner conductors. These additional protections improve the fire performance and general characteristics of our cable. The Doncaster Cables Firesure Plus design offers numerous advantages in comparison to some other suppliers who opt for a longitudinally applied tape design. These longitudinal designs mean that the metallic tape required is simply folded along the inner conductors with a minimum 1mm tape overlap. In comparison to this, the Firesure Plus design consists of 2 helically applied copper tapes. This helically applied tape design means that both tapes are continuously wrapped around the conductors with a minimum tape overlap of 20%. This increased overlap allows for the following key performance benefits. The following benefits are further amplified through Firesure Plus cable as there are two metallic tapes as opposed to the minimum British Standard requirement of a single tape. FIRESURE PLUS KEY BENEFITS IN COMPARISON TO OTHER FIRE PERFORMANCE CABLES: HIGHER RESISTANCE TO ELECTROMAGNETIC INTERFERENCE SUPERIOR EARTH CONTINUITY (The bare CPC is placed between two copper tapes) RESISTANCE TO CABLE KINKS (Subsequently protecting cables performance) EXTREMELY ROBUST/DURABLE DESIGN (Due to increased tape numbers and overlap) IMPROVED DATA TRANSMISSION (Due to twisted cores and additional screening) Sales Office: Millfield Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire, DN5 0SJ Tel: 01302 821700 Fax: 01302 821701 Email: sales@doncastercables.com

Certificate of Product Approval Certificate Number: 338b Issue: 04 Doncaster Cables Millfields Industrial Estate Arksey Lane Bentley Doncaster South Yorkshire DN5 0SJ is authorised to use the LPCB mark in association with the product(s) listed in this certificate and appendix having complied with the requirements of the standard(s) detailed below: Product(s) Cable Types as listed below: FIRESURE PLUS See Certificate Appendix for details Standard(s) (see Appendix for details) BS 7629-1:2015 ( 120) BS 6387:2013 (Category CWZ) IEC 60331-21:1999 IEC 60332-3-24:2000+A1:2008 EN 50200:2015 ( ) BS 8434-2:2003+A2:2009 (120 mins) BS 5839-1:2002+A2:2013 (Clause 26.2e) This Certificate is maintained and held in force through regular surveillance activities and subject to the corresponding ISO 9001 Certificate being maintained. Damien Ward 19 December 2016 14 February 2008 Signed for LPCB Certification Scheme Manager Date of Issue Date of First issue This certificate and appendix remain the property of BRE Global Ltd and is issued subject to terms and conditions (for details visit www.redbooklive.com/terms). To check the validity of this certificate and appendix please visit www.redbooklive.com/check, scan the QR tag or contact us. LPCB is part of BRE Global Ltd, Garston, Watford, WD25 9XX T: +44 (0)333 321 8811 F: +44 (0)1923 664603 E: enquiries@breglobal.com BF1345 Rev. 0.3 Page 1 of 2 BRE Global Ltd, 2015

Appendix to Certificate No: 338b Issue: 04 Doncaster Cables Product name LPCB Ref. No. FIRESURE PLUS 338b/01 csa of conductor (mm 2 ) Core Construction BS 7629-1 BS 6387 IEC 60311-21 IEC 60332-3-24 EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 1.0( 1) 2 120 (3) C,W,Z Complies (4) Complies 1.5 (1) 2,3 & 4 120 (3) C,W,Z Complies (4) Complies 2.5 (2) 2,3 & 4 120 (3) C,W,Z Complies (4) Complies 4.0 (2) 2,3 & 4 120 (3) C,W,Z Complies (4) Complies Uo/U 300/500V Notes: 1. Solid conductor only. 2. Stranded conductor only. 3. In meeting the requirements of BS 7629-1:2015, the FIRESURE PLUS cables listed met the requirements for smoke density to EN 61034-2:2005+A1-2014, and achieved less than 0.5%HCI for the outer covering, binding tape & insulation when tested in accordance with EN 60754-1:2014 and in addition also met the fire resistance requirements in BS 6387:2013 Categories CWZ. 4. These cables met the requirements of IEC 60331-21:1999 when tested at a temperature of 950 C 5. The duration of 120 min when tested in accordance with BS 8434-2:2003+A2:2009 is achieved by 60 min for the fire and impact phase and an additional 60 min for the fire, impact and water phase as described in Clause 26.2e of BS 5839-1:2013. 6. The FIRESURE PLUS cables listed conform to BS 7629-1:2015, met PH 120 when tested in accordance with EN 50200: 2015 and met a duration of 120min duration when tested in accordance with BS 8434-2:2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2e of BS 5839-1:2013. This Certificate is maintained and held in force through regular surveillance activities and subject to the corresponding ISO 9001 Certificate being maintained. Damien Ward 19 December 2016 14 February 2008 Signed for LPCB Certification Scheme Manager Date of Issue Date of First issue This certificate and appendix remain the property of BRE Global Ltd and is issued subject to terms and conditions (for details visit www.redbooklive.com/terms). To check the validity of this certificate and appendix please visit www.redbooklive.com/check, scan the QR tag or contact us. LPCB is part of BRE Global Ltd, Garston, Watford, WD25 9XX T: +44 (0)333 321 8811 F: +44 (0)1923 664603 E: enquiries@breglobal.com BF1345 Rev. 0.3 Page 2 of 2 BRE Global Ltd, 2015