The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

Similar documents
The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Open / Closed Sensors OPEN / CLOSED. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Dry Contact Sensors. General Description. Features of Monnit ALTA Sensors

Wireless Water Detection Sensors General Description Features of Monnit ALTA Sensors Water Detection Principle of Operation

The Leading Enterprise Internet of Things Solution. Wireless AC Voltage Detection Sensors ( VAC) VOLTAGE DETECT. General Description

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. General Description. Features of Monnit ALTA Sensors

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Wireless DC Voltage Detector

Wireless Light Detection Sensor

Wireless Thermocouple Sensor

Wireless 0-5 Volt Meter Sensor

Wireless Duct Temperature Sensor

Frequently Asked Questions

Smart Monitoring Systems. for Property Management SMART SOLUTIONS. Property Management DOORS & WINDOWS TEMPERATURES LIGHTS CARBON MONOXIDE

REMOTE MONITORING AND ALARM SYSTEM

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

Ion Gateway Cellular Gateway and Wireless Sensors

BSC-50 ADU-500. Autonomous RTUs

HOBO U30 Remote Monitoring Systems

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Quick Touch Pendant User Guide

WAVE SEQUENCER DELIVERS:

Smart Wireless Sensor

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Architectural and Engineering Specification for a. Flash / Flare

Monnit Wireless Local Alert. User s Guide

SAFESITE Multi-Threat Detection System

Fiber Optic Cable Fence Disturbance Sensor

Architectural and Engineering Specification for a Real-Time Locating System Flare

Smart Wireless Sensor

Q3200 Smart Home Alarm. Kit Content and Installation Guide

Emergency Communications Tower Applications (Solar/Wireless/Surveillance)

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

DS500. Alarm Sensors (built in) Power. Sounds. Accessories* Attachment

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Essential Insight.mesh Wireless System,

Photoelectric Beam Detector

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

LIGHTNING PROTECTION SYSTEM

AirTest Technologies Inc.

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Panel XTO210/610/710 GPRS

ACTIVE INFRARED BARRIER

Hazardous Area Ringdown Telephone

wireless. web-based. worthy of the name RACO.

Specifications Minimum Typical Maximum Unit

Selecting an Electrical Enclosure

Smart Security, Always Connected

User Guide. Alert. Locate. Respond. A Mobile Worker Safety Device Complementing Loner Mobile. SureSafe Safety Monitoring confirmation light

EW 40 Wireless Fan Control

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

STRIKE GUARD DELIVERS:

DATAssure. Laboratory wireless alarm & monitoring system

D3 Wireless temperature alarm & monitoring system family. tek-troniks

>WIRELESS> ALARM SYSTEM CR200

Waspmote Plug & Sense! Quick Overview

Ross SysCon Control Panels

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Variable Frequency Drive SERIES MP800 VFD

FEATURES AND SPECIFICATIONS

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

EL-OEM-3 OEM Packaged Voltage Data Logger

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

ALTAIR 5X Multigas Detector Product Specification

Model OEM-2 INSTRUCTIONS FOR USE

Arlo Wire-Free Smart Security Lights. No cords. No wires. No worries. 100% Wire-Free. Fully Customizable. Works with Arlo Camera Systems

Personal Assistance System Owner s Manual

New Recognition Certification for Access Hardware INDUSTRY ARTICLE

K100A Insertion Probe Thermometer

EL-USB-1-LCD Temperature Data Logger with LCD

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

Laboratory Refrigerator/Deep Freezer TC 802

WM3000 WIRELESS MODULES

NU2 Smart Power Supply (SPS) Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Solar-Powered BLE Sensor Beacon 5 Pack Kit Guide

TotalPac X Single interlock SUREFIRE system

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

Q3000 Smart Home Alarm. Kit Content and Installation Guide

environmental chambers for Battery testing

RAPID Alert System User Guide. RAPID Alert System. User Guide

FLOOD SERIES DATA SHEET

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

TotalPac X Firecycle III Preaction Double interlock system

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

INSTALLATION GUIDE XTLN-WIFI PANEL

Data Center. Cold Storage

SenSmart Universal Gas Detector Series

EWS3 WIRELESS INDOOR SIREN

ALTAIR 5X Multigas Detector

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

EWR2 WIRELESS SIGNAL REPEATER

1126 Series Ceiling Mount PIR Motion Detector

Signature Series 418 Mhz COMMUNICATOR RECEIVER INSTALLATION AND OPERATIONS MANUAL

Transcription:

Wireless 0-20 ma Current Meters by The Leading Enterprise Internet of Things Solution General Description The ALTA Wireless 0-20 ma Current Meter is capable of measuring the current off another device or sensor up to 20mA VDC. Measures current up to 20 ma Principle of Operation By connecting the leads on the ALTA Wireless 0-20 ma Current Meter to the positive and ground terminals of another device, the sensor can measure the current and send data to the imonnit Online Sensor Monitoring and Notification System. The data is stored in the online system and can be reviewed and exported as a data sheet or graph. Notifications can be set up through the online system to alert the user when certain thresholds have been met or exceeded. Example Interfacing Current transducers ph sensors Dissolved oxygen sensors Pressure sensors Magnetic flow sensors Many additional applications Features of Monnit ALTA Sensors of 1,200+ feet through 12+ walls * Frequency-Hopping Spread Spectrum (FHSS) Improved interference immunity Improved power management for longer battery life ** (12+ years on AA batteries) Encrypt-RF (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages) Onboard data memory stores up to 512 readings per sensor: - 10-minute heartbeats = 3.5 days - 2-hour heartbeats = 42 days Over-the-air updates (future proof) Free imonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email * Actual range may vary depending on environment. ** Battery life is determined by sensor reporting frequency and other variables. Other power options are also available. Wireless Range Comparison Monnit Monnit ALTA Other Wireless Platforms Wifi Bluetooth PAGE 1

1.125 in (28.575 mm) 2.0 in (50.8 mm) 0.875 in (22.225 mm) ALTA Commercial Coin Cell Wireless 0-20 ma Current Meter Technical Specifications Supply voltage 2.0 3.8 VDC * 2.5 ma (MCU active), 5.5 ma (radio RX mode), 22.6 ma (radio TX mode) Operating temperature range (board circuitry and coin cell) -7 C to +60 C (20 F to +140 F) ** Optimal battery temperature range (coin cell) +10 C to +50 C (+50 F to +122 F) Full-scale current 0 20 ma *** 0.7 ounces Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A- G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 * Hardware cannot withstand negative voltage. Please take care when connecting a power device. ** At temperatures above 100 C, it is possible for the board circuitry to lose programmed memory. *** If application exceeds 20 ma the sensor will return a maximum reading of 20 ma. If current applied to measurement port PinchPower Enclosures _ CR2032 BATTERY CR2032 BATTERY + Pinch (press in on the sides) Pull (sensor away from base) Press (sensor back into base) PAGE 2

2.470 2.470 4.375 3.295 1.111 1.111 ALTA Commercial AA Wireless 0-20 ma Current Meter Technical Specifications Supply voltage 2.0 3.8 VDC (3.0 3.8 VDC using power supply) * Operating temperature range (board circuitry and batteries) Optimal battery temperature range (AA) 2.5 ma (MCU active), 5.5 ma (radio RX mode), 22.6 ma (radio TX mode) -18 C to 55 C (0 F to 130 F) using alkaline -40 C to 85 C (-40 F to 185 F) using lithium ** +10 C to +50 C (+50 F to +122 F) Full-scale current 0 20 ma *** 3.7 ounces Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A- G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 * ** *** Hardware cannot withstand negative voltage. Please take care when connecting a power device. At temperatures above 100 C, it is possible for the board circuitry to lose programmed memory. If application exceeds 20 ma the sensor will return a maximum reading of 20 ma. If current applied to measurement port Power Options The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 3.6 V power supply. The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage. Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements. PAGE 3

Industrial Wireless Sensor 2.316 in (58.84 mm) 3.701 in (94.0 mm) Height: 1.378 in (35.0 mm) ALTA Industrial Wireless 0-20 ma Current Meter Technical Specifications Supply voltage 2.0 3.8 VDC (3.0 3.8 VDC using power supply) * 2.5 ma (MCU active), 5.5 ma (radio RX mode), 22.6 ma (radio TX mode) Operating temperature range (board circuitry and battery) -40 C to +85 C (-40 F to +185 F) ** Included battery Max temperature range -40 to +85 C (-40 to +185 F) Capacity 1800 mah Optional solar feature Solar panel 5VDC/30mA (53mm x 30mm) Charging temperature range Max temperature range Included rechargeable battery 0 to 45 C (32 to 113 F) -20 to 60 C (-4 to 140 F) 600 mah/>2000 charge cycles (80% of initial capacity) Solar efficiency Optimized for high and low-light operation *** Full-scale current 0 20 ma **** Enclosure rating 4.7 ounces NEMA 1, 2, 4, 4x, 12 and 13 rated, sealed and weather proof UL rating UL Listed to UL508-4x specifications (File E194432) Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1. 868 and 433 MHz product tested and found to comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and EN 60950 * Hardware cannot withstand negative voltage. Please take care when connecting a power device. ** At temperatures above 100 C, it is possible for the board circuitry to lose programmed memory. *** Light present 25% of day yields 125% of operating power to support 10-minute heartbeats. **** If application exceeds 20 ma the sensor will return a maximum reading of 20 ma. If current applied to measurement port PAGE 4

Commercial Grade Sensors Monnit commercial grade sensors are designed for applications in ordinary environments (normal room temperature, humidity and atmospheric pressure). Do not use these sensors under the following conditions as these factors can deteriorate the product characteristics and cause failures and burnout. Corrosive gas or deoxidizing gas chlorine gas, hydrogen sulfide gas, ammonia gas, sulfuric acid gas, nitric oxides gas, etc. Volatile or flammable gas Dusty conditions Low-pressure or high-pressure environments Wet or excessively humid locations Places with salt water, oils chemical liquids or organic solvents Where there are excessively strong vibrations Other places where similar hazardous conditions exist Use these products within the specified temperature range. Higher temperature may cause deterioration of the characteristics or the material quality. Industrial Grade Sensors Type 1, 2, 4, 4X, 12 and 13 NEMA Rated Enclosure Monnit s Industrial sensors are enclosed in reliable, weatherproof NEMA-rated enclosures. Our NEMA-rated enclosures are constructed for both indoor or outdoor use and protect the sensor circuitry against the ingress of solid foreign objects like dust as well as the damaging effects of water (rain, sleet, snow, splashing water, and hose-directed water). Safe from falling dirt Protects against wind-blown dust Protects against rain, sleet, snow, splashing water, and hose-directed water Increased level of corrosion resistance Will remain undamaged by ice formation on the enclosure For more information about our products or to place an order, please contact our sales department at 801-561-5555. Visit us on the web at www.monnit.com. Monnit Corporation 3400 South West Temple Salt Lake City, UT 84115 801-561-5555 www.monnit.com Monnit, imonnit, ALTA, PinchPower, Encrypt-RF and all other trademarks are property of Monnit, Corp. 2018 Monnit Corp. All Rights Reserved. ADS-A004-1D (7/18)