LORAIN CSP DC Power System

Similar documents
LORAIN CIP 4890/48120 DC Power System

Galaxy Pulsar Plus Digital Battery Plant Controller

CPS V Cabinet Power System

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Galaxy Power System 4848/100 with Dual Rectifier Shelf (GPS 4848/100) H

Spectron LSN (Life Safety Network) Suggested Specifications

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Specification for On-Line UPS Battery Monitoring and Data Management System

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

SECTION POWER SUPPLIES AND DISTRIBUTION

Liebert PPC Second Generation Power Distribution Cabinet

Knürr RMS Compact II. Knürr RMS Compact II 2.81

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

APC BC300 Series 40kW 208/450/480V User Guide

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps

DGC-1000 DIGITAL GENSET CONTROLLER

FLOAT BATTERY CHARGERS

SECTION AUTOMATIC TRANSFER SWITCHES

ECO PDU PE7214/PE7216/PE7324/PE7328

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Addressable Fire Alarm Control Panel

I/A Series 716C 1/16 DIN Temperature Controller

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Powering The Network. Network DC Power Solutions: Power Systems Converters

DGC-500 DIGITAL GENSET CONTROLLER

MODEL NUMBER: SRCOOL60KCW

Autonomous control unit

Vocia VACIE. Reference Guide

VACIE REFERENCE GUIDE REVISION 1.2.6

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Monitoring Solutions

Constant voltage charger. Type UP 610. »We store the world's energy« Network

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

162P POWER PLANT VDC VDC. Critical Power Product Manual

Healthy. Atmosphere. for Pigs and Poultry. for a

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

ECC-50/100C. Emergency Command Center

UDC100 Universal Digital Controller Specifications

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Installation and Operation Manual Low Power (LP) DC Power System

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

LC1350 Level Controller

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Data Center. Cold Storage

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

/9308 External Battery Chargers Installation Instructions

RACK MONITORING SYSTEM RAMOS Ultra

Alarm module for leak detection with webserver

Temperature Controllers

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Advanced Test Equipment Rentals ATEC (2832)

Intelligent addressable fire alarm control panel

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Instructions for the fan motor control system with integrated wiring terminals SILVER C

NetSure -48 VDC Power System

RACK MONITORING SYSTEM - RAMOS Ultra

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

NP1200 Front-End Power Supplies: 85 Vac to 264 Vac Input, 48 Vdc to 56 Vdc Output; 1200 W

GasGard 100 Control System

Installation Manual COPYRIGHT NOTICE

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Architectural and Engineering Specification for a. Flash / Flare

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIESEL Engine Fire Pump Controllers Features

Constant climate chambers

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Multi-Zone Wireless Control Training Systems ( )

T7984 A,B,C Electronic Modulating Control Thermostats

Nardalert S3 TM Non-Ionizing Radiation Monitor

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Undercounter Refrigerator Operation Manual i.series and Horizon Series

4100U City and Relay Cards Installation Instructions

Touchpoint Pro Flexible Gas Control System

Transcription:

DC Power for Business-Critical Continuity Key Features Compact flexibility provides more space for revenue generating equipment Constant power delivers more current at lower voltages to meet load or recharge demand Wide operating range operates in the most demanding environments with operating input voltage from 85VAC to 300VAC Meets industry standards NEBS Level 3 certified and UL 1801 Eight binary inputs (5 user programmable) form C contacts for external alarm or control functions Eight user programmable outputs eight sets of form C alarm relay contacts are available Remote Access TCP/IP, web browser, SNMP compatible Compliant with global standards delivers quality, performance and dependability no matter what the application or location demands Description The LORAIN CSP 48300 power system is a modular -48VDC power system available in various configurations and capacities up to 300 amps. A basic system consists of a power shelf that incorporates a basic or advanced controller and up to five 750W or 1500W plug-in rectifiers, and an initial distribution panel with 18 plug-in positions accommodating bullet nose type fuse holders rated 1 to 100 amps or circuit breakers rated 1 to 250 amps and 8 positions for connecting batteries with or without protection devices. For smaller loads, an optional plug-in 10 position fuse module is available occupying 3 mounting position, offering fuses rated 0.18 to 10 amps. A second power shelf that accommodates up to six 750W or 1500W plug-in rectifiers and a second distribution panel with 26 plug-in positions for load protection devices can be added to increase the distribution position capacity. An optional low voltage disconnect can be configured for battery or load disconnect. Enterprise : 71

Application The LORAIN CSP power system is a front access system designed to be mounted in standard 23" frames or used in embedded applications with standard 23" mounting, with or without batteries. The system is rated for full continuous operation from -40 C to +50 C (with excursions to 65 C) and is NEBS Level 3 certified and UL(60950 & 1801). The system is designed to supply a filtered and regulated -48VDC source to any telecommunication equipment requiring up to 300 amps capacity such as POP sites, customer premises, outdoor cabinets, CEVs, vaults or shelters, and small Central Offices. Specific applications include: DLC, xdsl, DSLAM, broadband communications, multiplexers, radio base stations, microwave and PBX. LORAIN CSP power shelves Power Shelves The LORAIN CSP power shelves are 5.25" (3U) high, 13" deep and 23" wide. The initial power shelf mounts five rectifier modules and a controller module. The supplementary shelf mounts 6 rectifier modules. The shelves provide front to back ventilation with zero clearance required above or below. Each rectifier position provides interconnection points for the AC input, the DC output, and the control and alarm data bus (CAN protocol). The total output capacity is 150 amps for the initial shelf and 180 amps for the supplementary shelf. Each shelf provides connecting points for dual single phase 110/120 and 208/240VAC feeds, one for rectifiers 1, 3 and 5, and one for rectifiers 2, 4 and 6 (on the initial power shelf, position No. 6 is for the controller). The AC supply can be brought into the shelf through knockouts at the left rear side of the shelf, or through an optional AC interface box at the front left of the shelf for front access applications. DC output connection between shelves and distribution panels is made through internal bussing. 72 : Enterprise

1500W Rectifier Module Rectifier Modules The LORAIN CSP system uses 1500W or 750W constant power switch mode rectifier modules. Both rectifiers have a DC operating range of -43.0 to -58.5VDC. The 1500W module provides 1500W from 200 to 300VAC with current limiting at 34 amps. Output power is de-rated to 90% from 176 to 200VAC, to 60% at 120VAC, and to 50% at 100VAC. The 750W module provides 750W from 100 to 300VAC with current limiting at 17 amps. Both rectifiers provide up to 100% of rated output up to 75 C. In the typical operating range, the rectifiers have a power factor greater than.99, total harmonic distortion less than 5% and efficiencies of 91%. The rectifiers are hot swappable and have an integrated speed controlled field replaceable fan. Each rectifier can optionally be equipped with a field replaceable air filter. Three LED indicators provide visual status of normal operation, alarm, rectifier failure alarm, and fan failure alarm. Controller Modules Two controller modules are available for use in the LORAIN CSP system a basic controller and an advanced controller. The System Manager SP is the advanced controller. It has a graphical LCD display with four navigation keys. The local alarm display uses LED indicators for controller status and system major and minor alarms. Eight user programmable input ports and eight user programmable output ports with form C contacts are included. In addition to traditional system alarms and controls, the System Manager SP provides event and alarm history logs, an inventory log, and delivered DC power calculation. The System Manager SP can be accessed locally or remotely using a built-in web based Graphical User Interface. Local connection is made through the Ethernet port using a computer equipped with a web browser and crossover cable. Remote connection is made through a dial up network connection with a modem connected to the system s RS-232 port, or through a network LAN connection to the TCP/IP port (RJ45 jack). The following battery management capabilities are provided: battery database, temperature compensation, equalize, battery discharge test, and charge control. The Controller SP is the basic controller available with the LORAIN CSP system. The operational features of the Controller SP are as follows: local alarm display by means of three LED indicators, three alarm outputs (dry C contacts), and two sets of local test points for the measurement of the system s voltage and current. DIP switches are used to adjust float voltage, temperature compensation, and the optional low voltage disconnect. System Manager SP Controller SP Enterprise : 73

Distribution Panel Distribution Panels Two distribution panels are available for the LORAIN CSP system. The initial panel is 5.25" (3RU) high, 13.5" deep and 23" wide, with a discharge capacity of 300 amps and a charge capacity of 330 amps. The panel is equipped with 18 positions for load protection devices (circuit breakers or fuses), 8 positions for battery protective devices or a battery connection kit, a battery current shunt, and an optional LVD circuit factory-wired for either load disconnect or battery disconnect. The supplementary panel has the same dimensions as the initial panel and is equipped with 26 positions for load protection devices (circuit breakers or fuses) and no battery positions. Both the initial and supplementary distribution panels provide local fuse and/or circuit breaker alarm indication by means of a red LED indicator, and one side of the protection device plugs into a main rail bus, while the other side plugs into a removable load clip designed to facilitate cabling operations. Load clips are available in three sizes single, double or quadruple position. The single position accommodates circuit breakers or fuse holders with TPS fuses from 1 to 60 amps. Double position load clips accommodate circuit breakers from 65 to 150 amps and fuses from 65 to 100 amps. Quadruple position load clips accommodate 225 & 250 amp circuit breakers. Batteries The LORAIN CSP system can be configured with a wide range of batteries to suit specific load and reserve requirements. Battery connections are made to the initial distribution panel through protection devices or directly using the factory installed Battery Connection Module. Temperature Probe Interface (TPI) The Temperature Probe Interface is a module that can monitor an ambient temperature probe and up to eight battery temperature probes, then retransmit the ambient temperature and the highest battery temperature measurements to the controller. The added number of measuring points improves the accuracy of the temperature compensation function and the precision of the high battery temperature. The TPI has two visual indications, Power ON (green) and Probe Fail alarm (yellow), as well as one set of fail safe output relay contacts for the Probe Fail alarm. 74 : Enterprise

LORAIN CSP 48300 General Specifications System Characteristics Nominal system voltage -48VDC Rated output capacity 300 amps discharge, 330 amps charge Rectifiers Rectifier 48VDC, 1500W or Rectifier 48VDC, 750W Controller Basic Controller SP Advanced System manager SP Distribution Initial and Supplementary Distribution Panels Environmental Operating temperature -40 F to 122 F (-40 C to 50 C) continuous operation Storage -40 F to 167 F (-40 C to 75 C) Relative humidity and transportation below 95% (non-condensing) Seismic rating Telcordia GR-63-CORE, zone 4 NEBS Level 3 certified Safety UL per subject letter 1801, UL60950, CE marked, FCC part 15, subpart B and Telcordia GR-1089-CORE & Emissions for Class B, EN 300 386 Rectifier -48VDC, 1500W Specifications Electrical Specifications AC input Nominal Voltage Operating Voltage Range Frequency Power factor (PF) Total Harmonic Distortion Input Current Inrush Current Input Protection Operating Efficiency Single phase, 110/120VAC or 208/240VAC Can be used in the following AC configurations: phase-to-phase to 120/240V single phase AC source phase-to-phase to a 120/208V 3-phase AC source phase-to-neutral to a 220/380V, 230/400V, 240/415V, or 277/480V 3-phase AC source phase-to-neutral to a 120/240V single phase AC source phase-to-neutral to a 120/208V 3-phase AC source 85VAC to 300VAC 47 Hz to 63 Hz >0.99 from 80% to 100% load at 208 & 240VAC >0.97 from 50% to 80% load at 208 & 240VAC <5% from 70% to 100% load at 208 & 240VAC Meets IEC 1000-3-2 7.0 amp at 240VAC (Max 9.0 amp) 8.7 amp at 120VAC (Max 9.0 amp) Peak does not exceed 2.5 times the RMS input current at any load under input current within rated input voltage range. If the input voltage decreases or increases beyond a non-adjustable predetermined value, the rectifier circuitry inhibits, disabling the output. The rectifier will recover automatically when the AC input is re-established within specification limits. Over current is protected by an internal fuse 91.5% at 80% load and 240VAC >90% from 40% to 100% load at 240VAC Enterprise : 75

Rectifier -48VDC, 1500W Specifications (continued) DC Output Output Voltage Range -43.0VDC to -58.5VDC Output Power Constant power limiting operation 1500W maximum from 200VAC to 300VAC 900W @ 120VAC 600W @ 85VAC Output Current 25 to 34 amps Regulation Voltage is regulated within ±0.5% for all specified input and load variations Voltage drift ±0.2% in any eight-hour period, with constant input voltage, constant load, and less than 5 C change in ambient temperature Voice Band Noise The voice-frequency noise generated by a rectifier does not exceed 38dBrnC output noise Wide Band Noise Wide band noise generated by a rectifier is less than 100mVrms in any 3 khz band between 10kHz and 20MHz and less than 50mV rms over 20Mhz Peak to peak ripple voltage is less than 125mV from dc up to 100Mhz Psophometric Noise Does not exceed 1 mv Protection Current Limiting The output current is limited to 34 amp Over current Internal fuse High Voltage Shutdown If rectifier detects over voltage, it will turn off. After 10 seconds, it will restart and if it encounters an over voltage within 5 minutes it will turn off and remain off until reset. Operating Specifications Temperature -40 F to 167 F (-40 C to 75 C) at full rated output Altitude -200 ft to 13,000 ft (-60 m to 4000 m) Humidity 0 to 95% relative humidity (non-condensing) Storage conditions -40 F to 167 F (-40 C to 75 C) Relative humidity below 95% (non-condensing) Ventilation Front to back speed-controlled fan (field replaceable) Seismic Telcordia GR-63-CORE for Zone 4 Electromagnetic Interference (EMI) FCC part 15, subpart B, class B and compatibility (EMC) EN 300 386-2, class B Audible noise The rectifier does not produce sound levels above 60dBA, measured 1.5m above the floor and 0.5 m from the equipment Operation without Yes batteries Status / Alarm Indicators and Monitoring Visual indicators Status Visual indicator color Normal operation Green Alarm Yellow Rectifier failure alarm Red Fan failure alarm Flashing red Rectifier alarms & Transmitted to System Manager SP or Controller SP on the communication bus using the CAN protocol Status Settings The Controller SP or System Manager SP establishes all rectifier settings Miscellaneous data Each rectifier provides the System Manager SP a complete set of identification information about itself (product code, serial number, alarm history, etc.) 76 : Enterprise

Rectifier -48VDC, 1500W Specifications (continued) Rectifier Physical Specifications Mounting Plug-in installation Dimensions (H x W x D) 5.25" (133mm) x 3.35" (85mm) x 11.00" (279mm) Weight 5.5 lbs. (2.5kg) Fire Resistance All materials have flammability rating -UL 94 V0 or better All electrical components meet the Needle Flame Test per IEC 695-2-2 Safety The rectifier is UL recognized (UL60950) for USA & Canada and is CE marked Rectifier -48VDC, 750W Specifications Electrical Specifications AC Input Nominal Voltage Operating Voltage Range Frequency Power Factor (PF) Total Harmonic Distortion Input Current Inrush Current Input Protection Operating Efficiency DC Output Output Voltage Range Output Power Output Current Regulation Voice-Frequency High Frequency Output Noise Psophometric Noise Single phase, 110/120VAC or 208/240VAC Can be used in the following AC configurations: phase-to-phase to 120/240V single phase AC source phase-to-phase to a 120/208V 3-phase AC source phase-to-neutral to a 220/380V, 230/400V, 240/415V, or 277/480V 3-phase AC source phase-to-neutral to a 120/240V single phase AC source phase-to-neutral to a 120/208V 3-phase AC source 85VAC to 300VAC 47 Hz to 63 Hz >.99 from 40% to 100% load at 120V >6% from 40% to 100% load at 120V Meets IEC 1000-3-2 7.1 amp at 120VAC (Max 9.0 amp) 3.5 amp at 240VAC Peak does not exceed 2.5 times the RMS input at any load at 120VAC input voltage If the input voltage decreases or increases beyond a non-adjustable predetermined value, the rectifier circuitry inhibits, disabling the output. The rectifier will recover automatically when the AC input is re-established within specification limits. Over current is protected by an internal fuse 91.5% at 100% load and 240VAC 89% at 100% load and 120VAC -43.0VDC to -58.5VDC Constant power limiting feature 750W maximum from 100VAC to 300VAC 600W at 85VAC 12 to 17 amps Voltage is regulated within ±0.5% for all specified input and load variations Voltage drift ±0.2% in any eight-hour period, with constant input voltage, constant load, and less than 5 C change in ambient temperature The voice-frequency noise generated by a rectifier does not exceed 38dBrnC output noise Wide band noise generated by a rectifier is less than 100mVrms in any 3 khz band between 10kHz and 20MHz and less than 50mV rms over 20Mhz Peak to peak ripple voltage is less than 200mV from dc up to 100Mhz Does not exceed 1 mv Enterprise : 77

Rectifier -48VDC, 750W Specifications (continued) Protection Current Limiting Over current High Voltage Shutdown The output current is limited to 17 amp Internal fuse If rectifier detects over voltage, it will turn off. After 10 seconds, it will restart and if it encounters an over voltage within 5 minutes it will turn off and remain off until reset. Operating Specifications Temperature -40 F to 167 F (-40 C to 75 C) at full rated power Altitude -200 ft to 13,000 ft (-60 m to 4000 m) Humidity 0 to 95% relative humidity (non-condensing) Storage conditions -40 F to 167 F (-40 C to 75 C) Relative humidity below 95% (non-condensing) Ventilation Front to back speed-controlled fan (field replaceable) Seismic Telcordia GR-63-CORE for Zone 4 Electromagnetic FCC part 15, subpart B, class B Interference (EMI) and compatibility (EMC) EN 300 386-2, class B Audible noise The rectifier does not produce sound levels above 60dBA, measured 1.5m above the floor and 0.5 m from the equipment Operation without Yes batteries Status / Alarm Indicators and Monitoring Visual indicators Status Visual indicator color Normal operation Green Alarm Yellow Rectifier failure alarm Red Fan failure alarm Flashing red Rectifier alarms & Transmitted to System Manager SP or Controller SP on the communication bus using the CAN protocol Status Settings The Controller SP or System Manager SP establishes all rectifier settings Miscellaneous data Each rectifier provides the System Manager SP a complete set of identification information about itself (product code, serial number, alarm history, etc.) Rectifier Physical Specifications Mounting Plug-in installation Dimensions (H x W x D) 5.25" (133mm) x 3.35" (85mm) x 11.00" (279mm) Weight 5.5 lbs. (2.5kg) Fire Resistance All materials have flammability rating -UL 94 V0 or better All electrical components meet the Needle Flame Test per IEC 695-2-2 Safety The rectifier is UL recognized (UL60950) for USA & Canada and is CE marked 78 : Enterprise

Power Shelf Specifications Capacity Initial shelf Supplementary Shelf Dimensions (H x W x D) Weight AC connections Recommended AC Service input 5 Rectifiers, Controller position, 150 amp 6 Rectifiers, 180 amp 5.25" (133mm) x 23" (584mm) x 13" (330 mm) Initial 11.8 lbs. (5.35kg) Supplementary 11.25 lbs. (5.1kg) Two connections per shelf (odd & even rectifiers) 30 amp, 2-pole AC breaker per 208/240V feed (3 rectifiers) 30 amp, 2-pole AC breaker per 110/120V feed (3 rectifiers) Controller Specifications Controller SP Display Alarm output Alarm input Control of rectifiers System configuration Battery management System Manager SP Display Alarm output Alarm input Control of rectifiers Battery management System configuration Communications ports Remote access LED status interface 3 dry C contacts outputs (Major, Minor, AC failure/bod) One external input for distribution and battery fuse alarm Digital CAN bus Dip switches for: System (float) voltage Temperature compensation battery charging Low voltage disconnect Low Voltage Disconnect (LVLD or LVBD) Temperature compensation battery charging LCD display with four navigation buttons 8 dry C contacts (5 programmable) SNMP & Web (HTML) 8 programmable inputs Digital CAN bus Battery Discharge Test Charge Control Low Voltage Disconnect (LVLD or LVBD) Temperature compensation battery charging Equalize (boost) Embedded Web Browser (HTTP) RJ45 jack for Ethernet port (TCP/IP) DB9 connector for RS-232 All essential functions and operational parameters through RS-232 modem and TCP/IP Ethernet with password security Enterprise : 79

Distribution Panel Specifications Capacity Initial panel Supplementary panel Protection devices Circuit breaker Fuses Battery connections Dimensions (H x W x D) Weight Initial panel Supplementary panel 18 load position, 8 battery connections, 300 amp Battery shunt, optional LVD (LVBD or LVLD) 26 load positions, 300 amp Bullet Nose type with load clip 1 to 60 amp use single position load clip 65 to 150 amp use double position load clip with spacing restrictions 225 and 250 amp use quadruple position load clip with spacing restrictions Bullet Nose type with load clip TPS type 1 to 60 amp use single load clip TPS & TLS Type 65 to 100 amp use double load clip SAN-O type 0.18 to 10 amp with 10 Position Fuse Block Protected using circuit breakers up to 200 amp Hardwired using optional Battery Connection Kit 7.0" (177.8mm) x 23.0" (584mm) x 13.5" (343mm) 27.5 lbs. (12.5kg) with LVD 24.3 lbs. (11.0kg) without LVD 24.3 lbs. (11.0kg) Emerson Network Power. The global leader in enabling businesscritical continuity. AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection 2007 Emerson Network Power Energy Systems, North America, Inc. All rights reserved. Emerson Network Power Energy Systems 1122 F St. Lorain, OH 44052 Toll Free: 800-800-1280 (USA and Canada) Telephone: 440-246-6999 Fax: 440-246-4876 Web: EmersonNetworkPower.com/EnergySystems This publication is issued to provide outline information only which (unless agreed by Emerson Network Power Energy Systems, North America, Inc. in writing) may not be used, applied or reproduced for any purpose or form part of any order or contract or be regarded as a representation relating to the products or services concerned. Emerson Network Power Energy Systems, North America, Inc. reserves the right to alter without notice the specification, design or conditions of supply of any product or service. The Emerson logo is a trademark and a service mark of Emerson Electric Co. Emerson Network Power is a division of Emerson Electric Co. Vortex, and LORAIN are trademarks of Emerson Network Power Energy Systems, North America, Inc. 80 : Enterprise Printed in USA