BKA-EN Fire Damper. Additional operating instructions according to

Similar documents
BSK-RPR Fire Damper. Additional operating instructions according to

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Fire protection unit

Fire dampers. For diverse applications

Manual Power relay SR853

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Flameproof Manual Call Points

Cooling Strip Model SPB

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

ExPolar Heating System

VERSAFLOW VORTEX Supplementary instructions

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Explosion Protection Enclosure with integrated measuring system

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

manual addendum DELPHI Ex

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Fan Coil Unit CULTRA

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

INSTRUCTION MANUAL (ATEX / IECEx)

Installation, Mounting and Maintenance DISA-300

Dual certification! Air handling units for potentially explosive atmospheres

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

AZN ATEX INSTALLATION AND MAINTENANCE

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Technical Data. Dimensions

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

PEPPERL+FUCHS GmbH

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR P 1010/2010 C Supplementary instructions

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Technical Data. Dimensions

OPTIWAVE X500 Supplementary Instructions

Waste water ejection unit

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

INSTRUCTION & SERVICE MANUAL

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Technical Data. Dimensions

SET-2000 Hi Level/Oil

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Translation of the assembly instructions with operating instructions and technical appendix

Snifter ATEX22 VERSION. User Manual. Distributor

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Explosion Proof Combination Signal db (A) / 5 Joule

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

Immersion heating type FL65.. PTB 97 ATEX 1027 X. March thuba Ltd. CH-4015 Basle Telefon Telefax

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Installation and Operating Instruction

Manual for QX0201 Push Button

Survey of electrical equipment installed in hazardous areas on tankers

UV Flame Supervision System

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Instructions For Use ENG. LED Magnifier Lamp

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

TYPE APPROVAL CERTIFICATE

COMPACT FLAME CONTROLLER CFC 2000

Technical Data. Dimensions

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

XB-EFA-8L-BK & XB-EFA-8R-BK

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Operating Manual MS220DA

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

SET Installation and Operating Instructions. Level switch for one sensor

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3-way switching valve

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

ATM Lighting sp. z o.o

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Certificate of Compliance

Earth-Rite II PLUS Static Earthing System

GREENKIT Smoke extraction and ventilation system for lift shafts

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Bevent Rasch BSKC6. - Fire /06/17

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

standards: standards:

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Documentation. Parallel Heating Cable. Type: ELP

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

805QS Pressure Switch-Transmitter

K Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Transcription:

Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01 SCHAKO Ferdinand Schad KG Telephone +49 (0) 7463-980-0 Steigstraße 25-27 Fax +49 (0) 7463-980-200 D-78600 Kolbingen www.schako.de info@schako.de

GENERAL CONDITIONS GENERAL CONDITIONS GENERAL DESCRIPTION AND INSTRUCTIONS DELIVERY AND STORAGE Upon receipt, the devices must be checked for completeness and transport damage. If the device was delivered incompletely or damaged, the forwarding company and the SCHAKO KG have to be informed immediately. These additional operating instructions must be observed prior to mounting and commissioning the device. These additional operating instructions contain basic information regarding its use in areas subject to explosion hazards to be observed during assembly, operation and maintenance. Prior to mounting and commissioning and during maintenance work, the present additional operating instructions must be read by the installer and the responsible skilled personnel/system operator! PERSONNEL QUALIFICATION AND TRAINING The personnel for assembly, inspection and maintenance must have the relevant qualification for this work. The area of responsibility, competence and monitoring of the personnel must be exactly regulated by the system operator. If the personnel does not have the required knowledge, it must be trained and instructed. Moreover, the system operator must ensure that the contents of the additional operating instructions are completely understood and adhered to by the personnel. SAFETY-CONSCIOUS WORK The safety instructions given in these additional operating instructions, the existing national and international regulations on explosion protection, accident prevention and the system operator's internal work, operating and safety regulations must be observed. The fire dampers must not be exposed directly to weather, solar radiation and moisture ( see also "General information"). MOUNTING INFORMATION Mounting, electrical connection work and commissioning must be carried out by skilled personnel only and in accordance with the recognised technical rules and the safety and accident prevention regulations. MAINTENANCE Only a device subjected to proper maintenance and kept in perfect condition can guarantee safe and reliable operation. When defective parts are replaced with spare parts, only SCHAKO KG original spare parts may be used. The SCHAKO KG cannot be held liable for any damage caused by using spare parts that are not original and will not give any warranty. HAZARD CAUSED BY NON-OBSERVANCE OF THE SAFETY INSTRUCTIONS Non-observance of the safety instructions can result both in putting persons and the environment and operating units at risk. Likewise, non-observance of the safety instructions will result in the loss of any claims for damages. DESIGNATED USE The devices have been designed for use in ventilation systems in areas subject to explosion hazards according to the ATEX marking "Device group II, Zones 1, 2 and 21, 22". These devices are not suitable for use in unreleased Ex zones. The operating safety of the delivered devices is only guaranteed when used in accordance with their designated use. No return possible! Version: 2015-08-17 Document: Z09/45 Page 2

DESCRIPTION DESCRIPTION Fire dampers built into ventilation ducts (air-conditioning systems) are used for the automatic locking of fire lobbies. The fire damper BKA-EN corresponds to DIN EN 15650, 13501-3 and EN 1366-2. The BKA-EN has been tested according to EN 1366-2 in accordance with the Declaration of Performance No. 09-19-DoP-BKA-EN-2013-07-01. It is in possession of the EC certificate of conformity 0761 - CPD - 0244. Its classification according to EN 13501-3 is EI 90 (v e, h o i o) S. According to Directive 94/9/EC, EC Conformity Certificate Number EPS 09 ATEX 2 153 X, its use is permitted in hazardous areas, not only with spring return actuator X10 (ExMax- 5.10-BF), including safety temperature limiter (FireSafe /ExPro-TT), but also with mechanical trigger via fusible link (manual actuation with or without ATEX limit switch ES-Ex). The fire damper is marked as follows according to ATEX: II 2 G IIC T6 II 2 D T80 C II 3 D T80 C *) EPS 09 ATEX 2 153 X The fire damper complies with the regulations of the ATEX directives and may be used in supply and return air installations of ventilation systems in areas subject to explosion hazards. The fire damper is certified for device group II, Zones 1, 2 and 21, 22. Zones 1 and 2 represent the application range containing gases/vapours, while Zones 21 and 22 represent the application range containing dusts. Classification by zone must be established by the system operator or planner in compliance with current standards. Note: In explosion-protected zones, only devices that have an ATEX approval for this use may be used. *) when using the safety temperature limiter FireSafe. The national standards and guidelines must be observed in connection with these additional operating instructions. For maintenance, servicing, retrofitting, etc., it may be necessary to provide on-site inspection openings in suspended ceilings, shaft walls, downstream ventilation ducts, etc. They must be built in in sufficient numbers and size and must not impair the functioning of the fire dampers. The fire dampers must be connected to the ventilation ducts of the ventilation system either on one or both sides. When connected on one side, finishing protective gratings made of non-flammable building materials (EN13501-1) must be provided on the opposite side. The fire dampers can be connected to non-flammable or to flammable ventilation ducts. No return possible! Version: 2015-08-17 Document: Z09/45 Page 3

Dimensions Available sizes [mm] Figure 1: Dimensions BKA-EN Figure 2: Dimensions of the BKA-EN with drive X10 (ExMax-5.10-BF) 1 Housing 2 Damper blade 3 Hand lever 4 Locking profile 5 Trigger device 6 Fusible link 7 Inspection openings opposite B < 800 x = B/2 B 800 x ~260 mm y ~100 mm from connection flange 8 Drive unit 9 Earthing connection 10 Drive X10 (ExMax-5.10-BF) 11 Safety temperature limiter Width Height 200 200 225 225 250 250 275 275 300 300 325 325 350 350 375 375 400 400 450 450 500 500 550 550 600 600 650 650 700 700 750 750 800 800 900 1000 1100 1200 1300 1400 1500 Table 1: Available sizes [mm] - Housing length L = 375 or 500mm (standard). - All combined heights and widths available. - Trigger device always on H side. - Inspection openings always on B side. - On request, the width and height dimensions are available in steps of 10 mm. No return possible! Version: 2015-08-17 Document: Z09/45 Page 4

Weight table [kg] BKA-EN with mechanical-thermal trigger (manual trigger) (added weight for drive X10 (ExMax-5.10-BF) max. ca. 4.5 kg) Table 2: Weight table [kg] BKA-EN L=375 Table 3: Weight table [kg] BKA-EN L=500 No return possible! Version: 2015-08-17 Document: Z09/45 Page 5

Electric spring return actuator X10 (ExMax-5.10-BF) X10 (ExMax-5.10-BF) Connection X10 (ExMax-5.10-BF) Open/closed 1-wire spring return + Ex-i circuit SB 7.0 BSK 24 240 VAC/DC integrated, permanently set auxiliary switch, max. 24V/3A, 240V/0.5A switching at an angle of rotation 5 and 85. The voltage on the auxiliary switch must be identical to the supply voltage and protected by a respective fuse. Ex-i circuit for passive, potential-free pushbuttons provided by the customer and thermally activated safety release device! Attention! For a 1-wire control, the heating is not active when the contact is in- Button Heating Standard connection = spring return in ~ 10 sec. Figure 3: Circuit diagram drive X10 (ExMax-5.10-BF) Electric explosion-protected spring return actuators with safety temperature limiter (FireSafe/ ExPro-TT). Trigger temperatures 72 optionally 95 C (for hotair heating). Operating position (damper "OPEN") and tensioning of the return spring by applying the supply voltage (universal power supply 24-240 VAC/DC) Safety position (damper "CLOSED") through spring force when supply voltage is interrupted or the temperature fuses (ambient temperature or internal duct temperature) respond. A response of the thermal fuses will interrupt the sensor circuit permanently and irrevocably. End position signalling by integrated auxiliary switches, switching at an angle of rotation of 5 and 85. On-site function control is possible by means of the control key of of the safety temperature limiter Attention! Safety function is only guaranteed if the drive has been connected to the supply voltage in accordance with regulations. Technical data drive X10 (ExMax-5.10-BF) Power supply 24 240 V AC/DC, ± 10% each, self adaptable Frequency 50...60 Hz ± 20% Power consumption Holding max. 20 W Heating capacity approx. 16 W Current on approx. 2.0 A at 24 V for approx. 1 sec. making Running time 30s Motor Spring return 10s Auxiliary switch 2 integrated, permanently set, potential-free auxiliary switch with changeover contact Switching 24 V DC / 230 V AC voltage Switch voltage 0.5 ma - 3 A Switching Angles of rotation: 5 / 85 points Protection class I (earthed) Protection type according to DIN 60529 Tested according to EMC Safety tested Ambient temperature (operation) Ambient humidity IP 66 2004/108/EC 2006/95/EC -40... +40 C 95%, non-condensing Table 4: Technical data drive X10 (ExMax-5.10-BF) No return possible! Version: 2015-08-17 Document: Z09/45 Page 6

Limit switch type ES-Ex Limit switch for application in areas subject to explosion hazards II 2G Ex d IIC T6/T5 Gb, II 2D Ex tb IIIC T 80 C/ 95 C Db IP65; 250V / 6A AC15; 230V / 0.25A DC13; -20 C Ta +65 C Figure 4: Circuit diagram limit switch type ES-Ex General information During mounting or installation, there is a risk of injuries. To avoid any possible injuries, personal protective equipment (PPE) must be worn. Fire dampers must be installed such that external forces do not impair their permanent functioning. During mounting it may be required to provide reinforcements for the housing or the like. The requirement of statically load-bearing lintels may have to be taken into consideration. Improper transport/handling may result in damage/functional impairment. In addition to that, the film of the transport packaging must be removed and the delivery inspected for completeness. In storage, fire dampers must be protected from dust, dirt, moisture and the effects of temperature (e.g. direct sunlight, heat-emitting light source, etc.). They must not be exposed to direct effects of the weather and must not be stored below -40 C (ES-Ex -20 C) or above 50 C. The fire damper must be protected from dirt and damage. After installation is complete, any dirt must be removed immediately. Enough space must be provided for installation, mortar lining, etc. Carry out a functional check of the fire damper before and after mounting and ensure ready access. Electrical installations or work on electrical components may only be carried out by skilled electricians. The supply voltage must be switched off when performing this work. No return possible! Version: 2015-08-17 Document: Z09/45 Page 7

Information regarding assembly and commissioning Prior to being installed in the ventilation system, the fire damper must be checked for damage. Damaged fire dampers must not be installed. The device may only be used in accordance with its designated use in air ventilation systems for supply air and return air. Use only approved fastening material for mounting. No additional parts may be fastened to the fire damper. The fire damper must be connected to the ventilation duct network on both sides in electrically conducting fashion. In order to avoid the risk of static charges, the fire damper must be connected to the on-site equipotential bonding on the grounding connection provided for this purpose. Make sure that the ventilation systems are not subjected to any anomalous operating conditions, such as vibrations, pressure surges or high proportions of solids in the medium. Information regarding maintenance and inspection Proper maintenance increases operational safety and the service life of the device. This is why the devices should be subjected to regular inspection. If inspection dates are prescribed by law, they must be complied with. The operating personnel must be informed, prior to starting maintenance and inspection work. The personal safety measures must be looked up in the safety data sheet. Hazard caused by contact or inhaling hazardous substances must be excluded by taking appropriate safety measures. The following inspection criteria must be observed: Visual inspection of the device Check the fastening of the device Check the electrical connections Check the grounding connection for tight fit and good contact. Functional check For additional inspections, please refer to the technical documentation or additional maintenance instructions. Use and electrical connection of actuators in areas subject to explosion hazards Only ATEX-approved electrical equipment according to ATEX Directive 94/9/EC for Zones 1, 2, 21, 22, such as actuators, terminal boxes and thermocouples as specified by SCHAKO KG may be used for devices from SCHAKO KG. The connection lines must be installed for permanent use and in such a way that they are sufficiently protected from mechanical and thermal damage. Devises with explosion-protected drives and terminal boxes have to be attached over the external potential connecting terminal to the potential equalisation provided by the customer with at least 4 mm² cooper solid-core. The electrical connection lines of the actuators must be connected in a terminal box according ATEX Directive 94/9/EC for Zones 1, 2, 21, 22 if the electrical connection is made in the area subject to explosion hazards. The dimensioning of the conductor cross-sections must be observed. The actuators are maintenance-free with respect to their function, but the relevant maintenance regulations according to ATEX directives or factory regulations must be observed. Prior to maintenance or inspection, all system components up- and downstream of the device must be switched off and secured against being switched on again. No return possible! Version: 2015-08-17 Document: Z09/45 Page 8

Certificate of conformity No return possible! Version: 2015-08-17 Document: Z09/45 Page 9

No return possible! Version: 2015-08-17 Document: Z09/45 Page 10