Electrical Installation Instructions

Similar documents
Figure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -

Steamist Installation Guidelines

Installation Instructions PRO SERIES

POWER PAK 480V Commercial Steam bath Generator

Mini Mist Installation Instructions. Health. Relaxation. Exhilaration

INSTALLATION INSTRUCTIONS FOR MULTI-UNIT RESIDENTIAL APPLICATIONS INSTALLATION INSTRUCTIONS ARE PER UNIT MODELS: RS-502C, RS-503C, RS-702C, RS-703C

L A signature series TA T N E RE O, A L L A T S IN

signals a situation where minor injury or product damage may occur if you do not follow instructions.

Owners Manual. Pub. No. 601-D

E2 Series Installation

Installation Instructions Day Spa Generator

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Steamist Sauna Heaters

Commercial Series Installation Instructions. Health. Relaxation. Exhilaration

INSTALLATION INSTRUCTIONS FOR MODELS JR-3 & JR-4

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

CN 2015 INSTALLATION INSTRUCTIONS MODELS JR-3 & JR-4 240/208 VOLTS 1 PHASE USE ONLY RELAX-A-MIST FACTORY SUPPLIED PARTS

Installation, Operation & Maintenance Manual. mr.steam. Feel Good Inc.

Spa Control System OWNER S MANUAL

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

SYSTEM INSTALLATION AND SERVICE AT AND 3T STEAMERS

AT and 3T STEAMBATH GENERATORS For Models 4kW thru 14kW With T100 Control (Includes Optional Warm Start)

Installation, Operation and Maintenance Manual. Steambath Generator Systems. Residential Models: MS90E MS400E and MSSUPER1E 6E

SK SERIES INSTALLATION INSTRUCTIONS 1

PRO SERIES IMPORTANT SAFETY INFORMATION

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Before you begin, carefully read the installation instructions below. Observe all local electrical safety and plumbing codes.

CADDY CORPORATION. Utility Distribution Systems

FREWIN STEAM SHOWER ENCLOSURE

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

General Guidelines for Installing Mr.Steam. Steambath Systems

WAIWELA SERIES-TWO WATER HEATERS

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Aquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)

Destination Collection Whirlpool Bath Installation Instructions

AWP 3260 CWH Installation Instructions Hydro-massage Bathtub - UL 1795

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

Dishwasher Installation Manual

DRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

AirBath Hydro-Massage Tubs UL1795 Installation and Operating Instructions

One Touch Control Installation and Operation Instructions

EEMAX SERIES-TWO WATER HEATERS

COPPER FREESTANDING TUB

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

For Tutorials and Troubleshooting visit

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

ThermaSol PowerPak Series Installation & Operating Instructions Commercial Steam Bath Generators (Three Phase)

LEVENS STEAM SHOWER ENCLOSURE

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Viking Installation Guide

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Laurel Mountain Whirlpools. Walk-In Bathtub Installation Manual

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

OVER 55 YEARS OF STEAM SHOWER INNOVATION

Installation Instructions

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

Elite Control Installation and Operation Instructions

SYSTEM BASIC WHIRLPOOLS

mr.steam Lexington Collection Feel Good Inc. REFER TO INSTALLATION, MAINTENANCE MANUAL PROVIDED WITH PRODUCT FOR COMPLETE INSTRUCTIONS

Dishwasher Installation Instructions DW 24XT/DW 24XV

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

Installation Instructions

FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

ARLEY STEAM SHOWER ENCLOSURE

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

Installation and Operation Guide

Instant Hot Water Dispenser Owner s Manual

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

1-866-PENNERS

Hot Water Boilers 810(E), 815(E), 830(E), 850(E) Table of Contents

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Model. Serial No. Installation, Operation and Maintenance Manual. Lexington Collection ELECTRIC TOWEL WARMERS. mr.steam. Feel Good Inc.

Vintage Whirlpool Baths: K-702-AC K-702-H-AC CA (9427) Copyright 1994 Kohler Co.

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

mr.steam AirButler Package mr.steam Sussman-Automatic Corp Technical Specifications AirButler Package For models MS90E to MSSUPER3E

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

Installation Instructions

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

INSTALLATION INSTRUCTIONS

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

Transcription:

Steambath Generators Models: SM-2 and SM-5! Electrical Installation Instructions C US LISTED 995C WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use steambath while under the influence of alcohol. IMPORTANT: the warranty of this product is voided if it is used in a commercial application or for anything other than a residential steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National Electric Codes. The Steamist SM generator operates with one or two controls appropriately located inside and/or outside the steamroom. It s small enough in size to be tucked away using very little space in a vanity, closet, basement, or an insulated attic, but large enough to provide steam for most residential baths. The Steamist SM Steambath Generator comes factory-assembled carefully wired and tested. NOTE: The TC-0, TC-5, DSC-25, and DSP Controls are designed to work with all Steamist SM Generators.. Pre-Installation 2. Electrical Rough-In Proper electrical supply (20 or 20 Volt): See rating label on Steam Generator and Chart on back page. Determine proper size of wire, voltage, amperage, and phase for the Steam Generator. Only UL rated 90 C wire can be used. In-line fuse/circuit breaker required: Fuse/circuit breaker to be installed must be sized in accordance with chart on back page. Do NOT install a GFI (Ground Fault Interrupter) to this equipment (per article 20- in the National Electric Code). Route power supply cable to the location where the Steam Generator will be installed (before walls are closed). Route appropriate power cable to the location the Steam Generator will be installed. If receptacle is desired, mount the box for the receptacle near the location of the Steam Generator (See Figure : Typical Installation). NOTE: The plug and receptacle require a rating of no less than 250V and proper amperage. Refer to chart on page for amperage rating. After the walls are complete, the Steam Generator and Control can be wired.. Steam Generator Electrical Installation d) e) Remove the six screws holding the electrical access cover and remove cover. Locate the supply line knockout. Mount proper strain relief into knockout hole. Strip back power cable s outer insulation jacket eight inches and insert into steam generator. Strip back insulation ½ from the three () incoming wires (two power and one ground). Insert ground wire into grounding lug located on the right side of the electrical compartment and secure. CAUTION: Be sure the ground wire does not come in contact with a live electrical part. Locate the terminal block in the upper portion of the electrical box. Insert power wires into the power lugs on the right of the terminal block and secure.. Optional Auto Drain Connection WARNING: All power to the steam generator must be turned off. Open knockout for Auto Drain conduit connection. Route flexible conduit from valve to knockout and secure. Connect two wires from valve to the two place terminal strip provided (See figure 2). Knock-out for Control Cable Electrical Panel Cover Figure Steam Generator Install Upright and Level Knock-outs for Electrical Supply Line ¾ Steam Outlet ¾ Safety Relief Inlet ⅜ Compression Fitting Optional Auto Drain Installed 07/07 - - Pub. No. 2-H

Before starting, insure that the conditions of the following checklist have been met: The proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure, Pricing Guide, or The Generator Sizing Guide in the Residential Systems/Steambath Product Information section of the Steamist web site - www.steamist.com. CAUTION: An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature. The proper voltage Steam Generator has been selected (i.e., 20V or 20V). A 20V generator operating on 20V will damage the heating element and a 20V Generator operating on 20V will result in a 25% loss of power. Checklist The Steam Generator is installed in an upright position. The proper sized 90 C wire and circuit breaker have been used. The circuit breaker is NOT a GFI (Ground Fault Interrupter) type. The Steam Generator is properly grounded. The circuit breaker or disconnect switch is on. Supply is open to the Steam Generator. Optional Steamist Splitter for two Controls Power Supply L and Plug Protective Covering Remove Before Installation Modular Jack Ground Contactor / Relay Single Phase Connections Shown Level Probe Printed Circuit Board Knock-Out for Auto Drain ¾ Steam Outlet Safety Relief Inlet ⅜ Compression Fitting Terminal Strip for Auto Drain Connection Optional Auto Drain Connection ½ Out When not equipped with Auto Drain leave drain line capped and closed 07/07-2 - Pub. No. 2-H

TIMER TIMER NOTE: Unit must be wired with 90 C wire in a suitable raceway, or, if local codes allow, provide twist lock plug on a 90 C wire cord from generator to a 250V 2 pole, -wire grounding receptacle (amperage rating as required). Outside Installation TC-0 or DSP Timer Only The Electrical Instructions must be given to the homeowner for future use. Inside Installation Control should be mounted four feet from the floor. Select a location convenient to the bather but not in a direct line of Shower or Body Sprays and not directly above the steamhead. 0 Control Cable Route from Control to Steam Generator in a ¾ conduit. TC-5, DSC-25, and DSP Temperature Control MUST be installed inside the shower. 5 Appropriately fuse protected 20/20V field wiring to Steam generator. IMPORTANT: Run the Control Cable through a ¾ conduit. Remove protective cap when making the final connection to Control. Figure : Typical installation 07/07 - - Pub. No. 2-H

TIME TIME SM-2/5 SINGLE PHASE SCHEMATIC SENSOR 9 HEAT Typical Steamist Control (Low Voltage) LLC-00- Circuit Board Multi-Conductor Level Probe Cable* WHT GREY P P P5 P6 P P L H XL P2 P DS DS DS2 DS P7 P9 See Chart Fuse 0.5 AMP P6 P5 Test P P7 Switch P2 P P0 P BRN ORG Fuse Block ORG Terminal Block Auto-Drain Thermostat Contactor / Relay L L L L COIL Noise Filter Field Connections ** T T2 T T BLU BLU Solenoid Optional Auto-Drain Model No. TANK Heating Elements SPECIFICATION CHART Max. Cu. Ft. For Area Up To KW Volt Phase Amps SM-2 50 2 SM-5 Typical Steamist Control 550 (Low Voltage) Multi-Conductor Cable* WHT GREY 5 20 20 20 20 20 20 20 20 LLC-00- Circuit Board P P P5 P6 P L H XL P2 P DS DS DS2 DS P7 Fuse 0.5 AMP P9 P6 50 5 29 6 72 6 2 See Chart P5 P2 Wire Size 90ºC Copper AWG 6 6 SM-2/5 THREE PHASE SCHEMATIC SENSOR 9 HEAT P NOTES: * Supplied with Controller. ** Field Connections, use 90ºC wire, gauge No. See Chart Copper. Test Switch P P P7 P0 P Line Fuse 70 0 0 5 0 90 5 60 Terminal Block DS DS2 DS DS Terminal Block L L LED COLOR CHART L L AMB COIL Noise Filter TIMER ON HEAT ON WATER FILL ON POWER ON L L Contactor / Relay T T2 T Field Connections ** Level Probe BRN ORG ORG Auto-Drain Sensor TANK Heating Elements BLU BLU Solenoid Optional Auto-Drain NOTES: * Supplied with Controller. ** Field Connections, use 90ºC wire, gauge No. See Chart Copper. East Coast Office: 275 Veterans Blvd., Rutherford, NJ 07070 Tel: (00) 577-67 Fax: (20) 9-076 West Coast Office: 5 W. Pondera St., Suite F, Lancaster, CA 95 Tel: (00) 55-67 Fax: (66)90-67 07/07 - - Pub. No. 2-H

Steambath Generators Models: SM-2 and SM-5! Plumbing Installation Instructions WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes, or who are otherwise not in good health, do not use this device unless directed to do so by a physician. Also, do not use steambath while under the influence of alcohol. C US LISTED 995C IMPORTANT: the warranty of this product is voided if it is used in a commercial application or for anything other than a residential steambath installation. The Steamist SM Generator comes factory assembled, carefully wired and tested. The Plumbing Installation must conform to local and national codes. All electrical power should be turned OFF when working with Steam Generator.. Pre-Installation Be sure that the proper size Steam Generator has been selected by using the sizing page in the Full Line Brochure, Pricing Guide, The Generator Sizing Guide, Architectural Guidelines, or in the Residential Systems/Steambath Product Information section of the Steamist web site - www.steamist.com. CAUTION: An improperly sized Steam Generator may NOT produce the amount of steam necessary to reach selected temperature. IMPORTANT: Refer to page for model required for cubic foot rating. The Steam Generator should be located as close as possible to the Steam Room/Shower or tub enclosure. Steam pipe should NOT exceed twenty-five feet in length. If the steam pipe exceeds ten feet, use an appropriate pipe insulation rated for a minimum of 22 F. Possible locations include Vanity, Closets, Attic (insulated), or Basement near bath area. The serial number plate should be visible and the Steam Generator should be accessible for service. Refer to Installation Suggestion on the page. Do NOT install Generator outdoors, in a moist humid area, or in an area where parts may freeze or corrode. Also, do NOT install near flammable materials such as paints, thinners, gasoline, etc. The steam line and safety valve reach a temperature of 22 F during operation and should be appropriately protected to prevent personal injury by accidental contact. 2. Plumbing Rough-In Plumbing rough-in is required for the water supply and steam line, this should be completed before the walls are closed. For operation, the SM Steam Generator requires a ⅜ O.D. copper tubing to the fitting on the generator for water inlet and ¾ copper or brass pipe for steam outlet. NOTE: Safety should be connected to a minimum ¾ indirect waste or as required by local plumbing codes. In the unlikely event this valve should open, the discharge must be directed to prevent damage to the home. Inlet - A water line should be roughed-in from existing ½ hot or cold water pipe. Using a ½ x ⅜ tee, cut and solder tee into the existing water line. (See Figure on page ). Solder a piece of ⅜ copper tubing into tee. Rough-in for water supply is now complete. Steam Outlet - Rough-in the steam line using a minimum of a ¾ copper or brass pipe, do NOT use black iron or galvanized pipe, it will rust and discolor the wall of the steam bath. The steamhead location should be above the shower floor or 6 above the rim of the bathtub, as far from the seating area as possible. CAUTION: No shut-off valve can be installed in the steam line. Do NOT create traps or valleys in this line which would trap condensation and block the flow of steam. The steam pipe should be pitched toward the Steam Generator allowing condensation to run back toward the Steam Generator (preferred), or toward the steamhead. Knock-out for Control Cable Electrical Panel Cover Figure Steam Generator Install Upright and Level Knock-outs for Electrical Supply Line ¾ Steam Outlet ¾ Safety Relief Inlet ⅜ Compression Fitting Optional Auto Drain Installed 07/07 - - Pub. No. 2-G

. Steam Generator Installation The Steam Generator should be mounted in a location convenient for hook-up and service by the Plumber and Electrician. CAUTION: The steam generator is designed to be used ONLY in an upright and level position, to do otherwise would damage the unit and void the warranty. d) The steam generator can be mounted to a wall or set on the floor. However, the unit must be secured. To secure the unit to a vertical wall, loosen the two screws holding the electrical access cover, remove cover (see Figure ). Located inside the cabinet near the top left and right corners are mounting holes. Place top cover back and secure. Connect the / water supply, described in Section 2 to the Steam Generator by first soldering a / valve into the previously installed water line. The valve must be kept in an open position during normal operation. In areas where high water pressure may be a problem a water hammer arrestor or a pressure regulator should be installed. Complete water supply by connecting / copper tubing from the valve to the water inlet compression fitting. Refer to Plumbing Diagram below. IMPORTANT: Do NOT use a saddle valve or piercing type valve for water connection. Connect the steam line from rough-in location described in Section 2 to the ¾ nipple on the steam generator using a union. In the shower, place the center of the escutcheon onto the steam pipe and screw the steamhead into place. Care must be taken not to scratch the steamhead or escutcheon with wrench. Be sure the steam slot in the steamhead is facing down. After the plumbing connections are complete the electrician may finish wiring the unit. Steam Generator Electric Solenoid Level Probe Union (Required) Free Flowing Steam Line Shut-off Hot or Cold Incoming Supply Installation Instruction for Steamhead & Escutcheon. 2... 5. Be sure the steam pipe is installed with the proper length pipe protruding through the wall. Apply silicone sealant around the pipe to seal the pipe to the wall. Slip the Escutcheon over the steamhead loosely. Screw on the steamhead making sure the steam opening is facing down. Hold the Escutcheon against the wall and tighten the retaining screw facing down. Steam Pipe Apply silicone around the steam pipe to form a water tight seal (Supplied with control package) Escutcheon Steamhead Tighten the screw to the steamhead with the screw to face down WARNING: When installing a steam pipe into a steam room made out of Acrylic, Cultured Marble, Corian, Swanstone, Resin, Plastic or an equivalent type of material, consult the manufacturer of the material for their recommendation on location of the steam pipe. Verify that the type of material used for the construction of the steam room is rated for a steam room environment. When installing a steam pipe, in the mentioned material type rooms, it is very critical in making sure that when the steam pipe protrudes into the steam room that it is centered in its ¼ hole and does not touch the edge of the wall material around the steam pipe. IMPORTANT: An optional steam diffuser (Not Included) is strongly recommended for small steam rooms. This option helps to better diffuse the steam and makes the steambath more comfortable. This option may not be necessary in larger steam rooms where the bather is sitting a few feet away from the steamhead. IMPORTANT: Install steam head above the shower floor or 6 above the rim of the Bathtub. Optional Auto Drain Connect to Indirect Waste or as Required by Local Codes. Pressure Safety Connect to Indirect Waste or as Required by Local Codes. Figure 2: Plumbing Diagram 07/07-2 - Pub. No. 2-G

TIMER TIMER WARNING: When installing the Steamist Unit in conjunction with an acrylic modular tub/shower unit, please consult the manufacturer of the module for location of the steamhead. The Plumbing Instructions must be given to the homeowner for future use. Slope ceiling 2 per foot Outside Installation TC-0 or DSP Timer Only TC-5, DSC-25, and DSP Temperature Control MUST be installed inside the Steam Room. 0 5 ⅜ Shut-off Keep in open position during normal operation. ½ x ½ x ⅜ Tee. Using existing Hot or Cold water supply. Steamhead Installation Steamhead should be mounted above the finished floor or 6 above the rim of the tub as far from the bather as possible. Union Required A ⅜ air gap is recommended below the door and the door should incorporate a splashguard. The top and sides of the shower opening must be sealed. Safety Connect ¾ pipe to an indirect waste or as required by Local Codes. Steam Outlet Pipe - Use a minimum of a ¾ Copper or Brass pipe. CAUTION: Do NOT install a Shut-off valve on the Steam outlet pipe. Do NOT create traps or valleys in this line which would prevent the flow of steam. The steam outlet pipe should be pitched toward the Steam Generator (preferred), allowing condensation to run back into the Steam Generator or toward the steam head. If the steam pipe exceeds ten feet, use an appropriate pipe insulation rated for a minimum of 22 F. Figure : Typical installation 07/07 - - Pub. No. 2-G

TIMER TIMER Access Requirements Use 5 with Optional Auto Drain 5 2 Select a location for mounting the Steam Generator that is accessible for installation and service. The access requirement indicates the minimum space for convenient access to Steam Generator. CAUTION: All models must be installed INDOORS, in a DRY, NON-FREEZING location away from flammable materials such as: Gasoline, Paints, Thinners, Etc... IMPORTANT: Steam Generator must be installed upright and level. 20 SPECIFICATION CHART Model * Max. Cu. Ft. Wire Size 90ºC No. For Area Up To KW Volt Phase Amps Copper AWG 20 50 6 SM-2 50 2 20 5 20 29 20 SM-5 550 5 20 20 20 20 6 72 6 2 6 Line Fuse 70 0 0 5 0 90 5 60 * Refer to the Steamist Sizing Guide for actual Cu. Ft. capacity. Installation Suggestions Alternate Attic Location (Insulate to Prevent Freezing) 0 22 Steam Generator in Vanity Alternate Closet Location Alternate Basement Location (Insulated and Dry) East Coast Office: 275 Veterans Blvd., Rutherford, NJ 07070 Tel: (00) 577-67 Fax: (20) 9-076 West Coast Office: 5 W. Pondera St., Suite F, Lancaster, CA 95 Tel: (00) 55-67 Fax: (66)90-67 07/07 - - Pub. No. 2-G

InstaMist Info Warning: Do not turn on the power to the steam generator until the installation is complete and the unit is ready to test/use. If the steam generator will not be in use for long periods of time (over 6 months) the power to the steam generator should be turned off. Important: In order for the InstaMist feature to function, water must always be in the tank. For this reason the Optional Auto-Drain can NOT be used with any InstaMist generators. The Steamist InstaMist Feature (-IM) is only available as a factory installed option on the following Models: SM-5, SM-7, SM-, SM-, SM-2, SM-5, System-, System-2, and System-0. Live Power Connection The Steamist InstaMist generators feature pre-heat function, which provides a generous volume of steam in under a minute. This new feature maintains an average water temperature of 0 F in the stainless steel reservior. When the steam generator is activated, the pre-heated water inside the steam generator quickly reaches the boiling point, allowing steam to flow out in under a minute. All Steamist steam generators with or without InstaMist are factory assembled and tested. There are no additional Plumbing or Electrical requirements needed in the field for generators with the InstaMist feature. The installation instructions for the plumber and the electrician are provided with the steam generator and need to be followed. 25 Watt Heater Hi-Limit Switch Thermostat 07/07 Pub. No. 2-A