ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO

Similar documents
ADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY.

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

HPP I PP OPERATING INSTRUCTIONS CONSTANT CLIMATE CHAMBER HPP COOLED INCUBATOR IPP PLUS 100% ATMOSAFE. MADE IN GERMANY.

Absolutely precise control of temperature, humidity, CO 2 and O 2 content from the experts for controlled atmosphere

UFTS OPERATING MANUAL PASS-THROUGH OVEN UFTS 100% ATMOSAFE. MADE IN GERMANY.

good reasons for a Memmert

UNxxmplus UFxxmplus INxxmplus IFxxmplus


Humidity Chambers HCP

CO 2 Incubators INCO 2

HPP OPERATING INSTRUCTIONS CONSTANT CLIMATE CHAMBER HPP 1060/ % ATMOSAFE. MADE IN GERMANY.

SERVICE MANUAL. IPP Cooled incubator with Peltier technology HPP 108 Constant Climate Chamber with humidification

ICH ICH L. ICH eco ICH L eco OPERATING INSTRUCTIONS CLIMATE CHAMBER ICH ICH L ICH ECO ICH L ECO 100% ATMOSAFE. MADE IN GERMANY.

ICP450. Compressor-cooled incubator. Product specification

SCAN200E USER S MANUAL

Service Instructions

IPP IPS OPERATING INSTRUCTIONS 100% ATMOSAFE. MADE IN GERMANY.

Memmert. Product Range. Heating. Cooling. Humidity. and O 2 CO 2. Light. Vacuum QUALITY - RELIABILITY - PRECISION. HEATING AND DRYING OVENS INCUBATORS

Waterbaths & Oilbaths

ICH260C. Climate Chamber. Product specification

ICH750L. Climate Chamber. Product specification

Operating Instructions. Sterilisers SNB SFB Universal ovens UNB UFB Incubators INB

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Call stations and extensions

SC-F3G User Manual 1.0

Healthy. Atmosphere. for Pigs and Poultry. for a

EC2-5x2 Series Condensing Unit Controllers

SCHMIDT LED Measured Value Display MD Instructions for Use

Сontrol panel Contact GSM-9N

ICH110. Climate Chamber. Product specification

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Affordable wireless monitoring without compromise

Using the Dome Motion Detector with SmartThings. Table of Contents

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

APC BC300 Series 40kW 208/450/480V User Guide

1.1 Setup Installation

Batt-Safe Battery String Monitoring System

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

ECO601 OPERATING INSTRUCTIONS ME04

Section PERIMETER SECURITY SYSTEMS

Constant climate chamber with ICH-compliant illumination

ThermoControl 0 C - 10 C - 20 C - 30 C

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR ICOmed COMPRESSOR-COOLED INCUBATOR ICP

ECO N DATE DESCRIPTION OF CHANGE CHG

Affordable wireless monitoring without compromise

testo 550 Digital manifold

Constant climate chamber with humidity

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

SMS GSM Alarm Messenger

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

EasyLog Data Logger Series

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Constant climate chambers

Specifications Minimum Typical Maximum Unit

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I. CO2 INCUBATOR ICOmed. COMPRESSOR-COOLED INCUBATOR ICPeco/ICP

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

INSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system

Environmental simulation chamber for complex alternating climate profiles

DCS-100. intelligent damper control & monitoring system

OPERATING INSTRUCTIONS. Waterbath WNE 7-45 WPE 45. Oilbath ONE 7-45

OC Series - Automatic coffee machines. OLC1 Lucia High performance liquid coffee dispenser. Users Handbook - 1 -

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

Engineering Guideline. pac- Carriers Type Universal

Optional Parts (sold separately): E-4WNSC-x 4-Wire Non-Sensing cable (available in lengths 10/25/50/100 feet and custom lengths up to 1000 feet)

6 CUFT BENCHTOP CO 2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and and

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EL-OEM-3 OEM Packaged Voltage Data Logger

Line Isolation Monitor (LIM) LIM2000plus

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

6 CUFT BENCHTOP CO2 INCUBATOR OPERATIONS MANUAL. FOR MODELS and

Circulators MV-4/ MV-6/ MV-12/ MV-26 MW-4/ MW-6/ MW-12/ MW-26 MW-Z

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Platelet bags constant shaking for long periods of time.

Radio fire warning panel SRC 3000

Labcom 200. Installation and User s Guide (230 VAC) Communication Unit

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Worldwide Leader in Technology

PORTABLE MOISTURE DETECTOR

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

EVO192 v3.0 Fire and Burglary What s New

1. Functions of GPS locator ETLOC-30S 3

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Vacuum Ovens VO. From orange juice to electronic chips vacuum technology protects heat-sensitive materials

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Model 1062 Environment Monitor

Using the Dome Leak Sensor with SmartThings. Table of Contents

User manual. KNXgal. version

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

NEW GENERATION. Efficient use of valuable space INCUBATORS

Fratech Multipath-IP

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Incubators PERFECTLY COORDINATED. PERFECTLY CONTROLLED. INCUBATOR I CO 2. INCUBATOR INCOmed COMPRESSOR-COOLED INCUBATOR ICP

Transcription:

ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO

Manufacturer and customer service MEMMERT GmbH + Co. KG Willi-Memmert Strasse 90-96 91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585 e-mail: sales@memmert.com Internet: www.memmert.com Customer service: Service hotline: +49 (0)9171 9792 911 Service fax: +49 (0)9171 9792 979 e-mail: service@memmert.com When calling for service enquiries, please state the appliance number given on the type plate. Shipping address for repairs: Memmert GmbH + Co. KG Customer service Willi-Memmert Str. 90-96 DE-91186 Büchenbach Germany Please contact our customer service department before sending appliances for repair or before returning equipment, or the shipment may be refused. 2018 MEMMERT GmbH + Co. KG Subject to change without notice

About this handbook About this handbook You can order different additional accessories for the CO2incubator ICO for added functionality or customer and application-specific adaptations. The following pages provide an overview of the additional accessories available. 3

Contents Contents 4 20 ma current loop interfaces (V3, V7, V9, V1) 5 4 20 ma current loop interface for temperature (V3)... 5 4 20 ma current loop interface for humidity (V7)... 5 4 20 ma current loop interface for CO 2 (V9)... 5 4 20 ma current loop interface for O 2 (V1)... 6 Uninterruptible power supply (battery backup) (C2) 6 Peltier cooling unit (housing cooling) for operation at high ambient temperature (K5) 7 Inner glass door with glass window door sections (K4) 7 Automatic switch-over of gas bottles (T1) 8 Hepa interior filter (item No. B38739) 8 MobileAlertBox (Option C4) 9 4

4 20 ma current loop interfaces (V3, V7, V9, V1) Additional accessories ICO With current loop interfaces, you can determine the instantaneous values within the appliance (temperature, humidity, CO 2, O 2 ) by measuring the current (ma) externally. The five-pin connector for connection of an ammeter (display range 0 to 20 ma) is on the back of the appliance. In case of a malfunction, 0 ma is displayed. 4 20 ma current loop interface for temperature (V3) Pin assignment Functional description Current loop interface 4-20 ma Range 4 ma 12 ma 20 ma 0 - + 70 C 0 C 35 C 70 C Other information R resistance: Max. 2.5 V at 20 ma = 125 Ohm 4 20 ma current loop interface for humidity (V7) Pin assignment Functional description Current loop interface 4-20 ma Range 4 ma 12 ma 20 ma 0-100 % rh 0 % rh 50 % rh 100 % rh xxx R resistance: Max. 2.5 V at 20 ma = 125 Ohm 4 20 ma current loop interface for CO 2 (V9) Pin assignment Functional description Current loop interface 4-20 ma Range 4 ma 12 ma 20 ma 0-25 % 0 % 12.5 % 25 % xxx R resistance: Max. 2.5 V at 20 ma = 125 Ohm 5

Additional accessories ICO 4 20 ma current loop interface for O 2 (V1) Pin assignment Functional description Current loop interface 4-20 ma Range 4 ma 12 ma 20 ma 0-25 % 0 % 12.5 % 25 % xxx R resistance: Max. 2.5 V at 20 ma = 125 Ohm Uninterruptible power supply (battery backup) (C2) The uninterruptible power supply (UPS), a battery backup installed in the appliance control unit (see image on the right) provides the controller with power for about an hour in case of a power failure. When the controller is powered by the UPS, the CO 2 control remains active and all parameters are recorded as usual. The beginning and the end of the power failure are recorded in the log memory. NOTICE The UPS does not provide the heating or humidity control with power. This may lead to condensation within the appliance. When the controller is powered by the UPS, the ControlCOCKPIT is displayed with a yellow background. After the power supply is restored, the battery will recharge automatically. To activate the UPS, press the button below the main switch (standby, see image on the right). If the UPS is activated, the button is illuminated. The UPS will only provide the appliance with power in case of a power failure if it is activated. To switch off the appliance, you have to deactivate the UPS first (by keeping the illuminated button pressed) and then press the main switch. To test that the UPS is working, disconnect the mains plug while the system is running with the UPS activated to simulate a power failure. 6

Additional accessories ICO Peltier cooling unit (housing cooling) for operation at high ambient temperature (K5) To make it possible to operate the system at temperatures of up to 2 K above room temperature, the ICO s air jacket needs to be cooled (example: 37 C interior temperature at 35 C ambient temperature). For this purpose, a housing cooling (Peltier cooling unit) A) can be installed on the back of the appliance. The housing cooling can be used up to an ambient temperature of 35 C, To activate the housing cooling, plug the power supply unit included in at the back A B of the appliance B. The cooling function switches on immediately (fan is running) and regulates itself. You can attach the power supply unit to the appliance using the Velcro fastener provided. Follow the instructions given in the service manual for retrofitting. Inner glass door with glass window door sections (K4) The ICO incubator can be equipped with inner glass doors that have door sections, which can be opened individually. This allows you to avoid opening the whole inner glass door to access part of the interior. The whole surface of both the door and the sections is heated. Follow the installation instructions given in the service manual for retrofitting. Versions Appliance size (I) Inner glass door version 50 105 two partitions, sections 460 x 170 mm 150 three partitions, sections 460 x 170 mm 240 four partitions, sections 500 x 150 mm 7

Additional accessories ICO Automatic switch-over of gas bottles (T1) The automatic switch-over of gas bottles ensures uninterrupted CO 2 supply to the appliance, even when a gas bottle is empty. The gas supply to the appliance is then automatically switched over to the second gas bottle. To facilitate this, the appliance has an additional CO 2 connection on the back of the appliance The number 1 or 2 shown on the CO 2 display of the ControlCOCKPIT indicates which gas bottle is currently active. When you switch the appliance on, CO2 IN1 is always used first. CO2 1 1.0 % Set 15.0 % Hepa interior filter (item No. B38739) The Hepa interior filter (disposable filter) meets the requirements of filter class E11 according to DIN EN 1822 and is installed in the fan box inside the appliance. The filter and housing are sterilised and sterile packed. The filter is suitable for use at temperatures up to 50 C and has to be removed from the appliance for sterilisation. 8

MobileAlertBox (Option C4) Additional accessories ICO A MobileAlertBox can be used to send an individual error message in the form of a text to a mobile phone. For this purpose and for each parameter, the appliance features a separate potential-free switching output, which triggers the MobileAlertBox. The maximum rating associated with the switching outputs for MobileAlert is 24 V/500 ma. There is a switching contact for temperature, humidity, CO 2, and O 2 (O 2 only for appliances featuring O 2 control): The 'Out 1' switching contact for text messaging sends a text message for the following errors: - Maximum value set for temperature exceeded - Minimum value set for temperature not reached - Automatic ASF tolerance band left - Mechanical temperature limiter (TL) has tripped - PT100 temperature sensor defective The 'Out 2' switching contact for text messaging sends a text message for the following errors: - Maximum value set for humidity exceeded - Minimum value set for humidity not reached - Humidity sensor defective The 'Out 3' switching contact for text messaging sends a text message for the following errors: - Maximum value set for CO 2 exceeded - Minimum value set for CO 2 not reached - CO 2 sensor defective The 'Out 4' switching contact for text messaging sends a text message for the following errors (only for appliances featuring O 2 control): - Maximum value set for O 2 exceeded - Minimum value set for O 2 not reached - O 2 sensor defective Out1 1 Com 2 Out2 3 temp/humidity Out3 1 Com 2 Out4 3 CO 2 / O 2 9

Additional accessories ICO English Memmert GmbH + Co. KG Willi-Memmert-Straße 90-96 D-91186 Büchenbach 15/06/2012 Tel. +49 9122 925-0 Fax +49 9122 14585 E-Mail: sales@memmert.com HPP/IPPplus English facebook.com/memmert.family D24029 Die Experten-Plattform: www.atmosafe.net