HOOK-UP AND LEAD WIRE. UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2. AWG Size. Number of Strands. Note: AWG 20 is available upon request.

Similar documents
Brand Portable Power Cord & Control Cable Solutions

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

Flexible Power Cable DLO

Flexible Heaters. of Silicone Rubber & Kapton

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Introducing SlimSeal SSL Connector

Belden Infinity C-TC+ Cables for Extreme Flexing

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Harnessing and Protection Products

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

LUH HORIZONTAL FAN-FORCED UNIT HEATER

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

RGE 13 A T - 1 A

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Revisions to this application specification include: Updated document to corporate requirements Changed product types in table in Figure 6

Cartridge/Insertion Heaters

Sensor and transducer cables

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

Mineral Insulated Band Heaters

Understanding Etched Foil Flexible Heaters

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

Braided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding

ASSOCIATIONS AND REFERENCE STANDARDS

pressure product catalog

PRODUCT CATALOGUE Norröna

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

ATUM-6/2-0-STK Product Details

Catalog Number. Notes

Phoenix Thermal Supply

Total Fire Solutions. Includes BS 8519 and the updated BS :

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

REFRIGERATION PRODUCTS

13 GEP A L P - 1 A

CREATING TOMORROW S SOLUTIONS MOBILITY. e-novation FOR ELECTRIC DRIVING POWERED BY SILICONES

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

Principle of Operation:

AKOCABLE Heating Cable Solutions Electrical Tracing

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Product Specifications Dialog Room Controller* (*patent pending)

Capabilities Catalog 12298_Tutco_Catalog.indd _Tutco_Catalog.indd 1 11/18/10 8:21:11 AM 11/18/10 8:21:11 AM

MACHINERY & EQUIPMENT INDUSTRY-SPECIFIC PROTECTION SOLUTIONS QUICK REFERENCE GUIDE

Cartridge Heaters. Hi-Density Cartridge Heaters. Features. To order, call or shop online at omega.com SM

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SolderSleeve Shield Terminators

Corporate/National Sales Office* 220 Glade View Drive, Roanoke, VA Fax

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

Norcold Instillation Instructions ARP Yahoo Group DRAFT Norcold General Installation Instructions

Unheated straight section Fast response time Choice of lead protection Longer heater life Higher watt densities Made to customer specifications

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

PERFORMANCE POLYMER SOLUTIONS

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

.2 Section Waste Management and Disposal.

Installation Requirements for Models:

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

MINING CABLES POWER YOUR MINE WITH TF KABLE

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

LOW PROFILE UNIT COOLER

Air-Cooled Condensing Units with Compact Screw Compressors

Drexan Energy Systems Inc.

A99B Series Temperature Sensor

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

Cartridge/Insertion Heaters

Gary Parker Refrigerants Product Manager

MEGAWAT * HIGH DENSITY CARTRIDGE HEATERS

Suppression of Class C Fires

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

FreezGard. Self-regulating crankcase heater. Product Overview

Installation and Operation of AST Equipment. Presenter: Steve Allwein Northeast Regional Sales Manager Morrison Bros. Co.

RNF-100-1/8-BK-STK Product Details

MARATHON HEATER. File # E Made in USA

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

ASME Packaged Indirect Fired Water Heater

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

HotRod CARTRIDGE HEATERS

Infinity 16 Heat Pump with Puron Refrigerant

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

CONNECT PROTECT IDENTIFY FASTEN SECURE

Condensing Units CUS 15-60

Nu-Brite Same popular Nu-Brite Powerful high foaming action lifts out dirt and grime while brightening coils Excellent & powerful cleaner that is espe

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

Downflow/Horizontal Right Induced Draft Gas Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

MEGADRUM & FLEXIDRUM BARREL HEATERS

ULTRA DYNAMIC HOSE PRODUCTS HOSE & TUBING CATALOG 2018 A DIVISION OF UBBER MPANY, INC. RUBBER COMPANY, INC RUBBER COMPANY, INC.

Transcription:

HOOK-UP AND LEAD WIRE PRODUCT DATA Rubber Insulated Wire UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2 Prestolite manufactures a full assortment of standard wire and cable products for the OEM in automotive and many other industries. These include welding cable, automotive primary wire, ABS cable, battery cable, and a large assortment of UL-approved cable styles and flex cordage. However, we specialize in designing custom cable and wire set solutions, including harness assemblies, to meet specific requirements for signal transmission, environmental concerns such as temperature or abrasion, and, for automotive applications, space constraints under the hood or in the chassis. Please contact us for any information on any standard or custom product need. 18 16 0.045 0.138 16 26 0.045 0.154 14 41 0.045 0.169 12 65 0.045 0.188 10 105 0.060 0.241 8 133 0.080 0.330 6 133 0.080 0.380 4 133 0.080 0.446 2 266 0.080 0.496 1 817 0.095 0.564 1/0 1045 0.095 0.610 2/0 1330 0.095 0.667 3/0 1672 0.095 0.714 4/0 2109 0.095 0.790 Note: 20 is available upon request. Separator Paper serve on 10 and larger 125 C For motor leads and internal wiring of appliances such as refrigerating equipment, room cooler units and heat pumps. For use as leads of transformers, motor ballasts, solenoids, etc. where the baking temperature of the windings and coils to which they are attached will not exceed 160 C. insulated wire provides a 125 C rated wire that has more flexibility than crosslinked polyolefin insulated wire with the same temperature rating

UL: 3311 CSA: CL-905 8 133 0.080 0.351 6 133 0.080 0.380 4 133 0.080 0.424 2 665 0.080 0.485 1 817 0.095 0.563 1/0 1064 0.095 0.625 2/0 1330 0.095 0.650 3/0 1672 0.095 0.746 4/0 2109 0.095 0.800 Note: Other sizes available upon request. 90 C For motor leads and internal wiring of appliances such as refrigerating equipment, room cooler units and heat pumps Suitable for other applications requiring tough, flexible, high current-carrying capacity cable Also suitable for welding cable applications where non-ul listed cable can be used, such as power feeds from the welding power source to the electrodes Exceptional flexibility for ease in handling Resistant to heat, moisture, ozone and chemicals Excellent low temperature flexibility down to -40 C and insulation resistance UL: 3614, 3374, 3340, Non VW-1 CSA: AWM I A/B, CL-1503, FT-2 20 10 0.045 0.131 10 105 0.045 0.222 4 133 0.060 0.400 3 133 0.060 0.451 2 266 0.060 0.471 2/0 1330 0.080 0.680 4/0 2109 0.080 0.780 Note: Other sizes available upon request. Temperature rating 125 C in flexing applications Temperature rating 150 C in non-flexing applications Temperatures not to exceed 150 C or 1000 Volts Internal wiring of appliances where exposed to temperatures not exceeding 125 C Where no flexing occurs either after installation or during service, a maximum temperature of 150 C is permissible Excellent durability at high temperatures and good low-temperature flexibility Excellent dielectric strength Flexing and non-flexing use More flexible than XLPE

HOOK-UP AND LEAD WIRE PRODUCT DATA Rubber Insulated Wire UL: 3484 CSA: AWM I B, FT-3 18 16 0.030 0.110 16 26 0.030 0.135 Note: Other sizes available upon request. 125 C Internal wiring of lighting fixtures, appliances or electrical equipment where exposed to temperatures not exceeding 125 C Excellent durability and flexibility UL: 3644 CSA: AWM I A/B, FT-2 18 7 0.030 0.106 Note: Other sizes available upon request. High-temp Prestosil 200 C 1000 Volts Internal wiring of appliances where totally enclosed and temperatures are not exceeding 200 C Excellent durability at high temperatures Excellent low-temperature flexibility Excellent flex life Excellent replacement for braided silicone

UL: 3328, VW-1 or Non-VW-1 CSA: AWM I A/B, CL-1255, FT-1 or FT-2 18 16 0.060 0.171 16 26 0.060 0.185 Note: Other sizes available upon request. 125 C Internal wiring of appliances where exposed to temperatures not exceeding 125 C Typical areas of application include refrigerating equipment, room cooler units and heat pumps Excellent durability at high temperatures and good low temperature flexibility Excellent dielectric strength More flexible than XLPE UL: 3357 CSA: None 20 41 0.045 0.130 18 65 0.045 0.145 80 C or 90 C 5000 Volts Test probe leads for electrical and electronic measuring and test equipment Excellent durability and flexibility

UL: 3193, VW-1 CSA: CL-1052, FT-1 3/0 259 0.080 0.700 4/0 259 0.080 0.814 Note: Other sizes available upon request. Hypalon* 105 C For internal wiring of appliances where temperatures do not exceed 105 C in air or 80 C in oil (UL) For use as leads of transformers, motors, ballasts, solenoids, etc., where the baking temperature of the windings, coils, etc. to which they are attached will not exceed 150 C (CSA) Hypalon insulation provides an excellent combination of flame and oil resistance, along with flexibility. UL: 3280 CSA: AWM I A/B 18 16 0.030 0.113 Note: Other sizes available upon request. 105 C 300 Volts Motor leads and internal wiring of appliances where exposed to temperatures not exceeding 105 C Excellent durability and flexibility *Hypalon is a registered trademark of DuPont Dow Elastomers.

HOOK-UP AND LEAD WIRE PRODUCT DATA Rubber Insulated Wire Dual Rated Cables UL: 3374, 3340, Non VW-1 CSA: CL-1254, FT-2 18 16 0.060 0.166 16 26 0.060 0.186 14 41 0.060 0.211 10 105 0.060 0.235 8 133 0.080 0.322 6 266 0.080 0.395 4 133 0.080 0.435 2 266 0.080 0.486 1 817 0.095 0.559 1/0 1045 0.095 0.640 2/0 1330 0.095 0.661 4/0 2109 0.095 0.790 Note: Other sizes available upon request. Stranded tinned copper Separator Paper serve on 10 and larger 125 C in flexing applications 150 C in non-flexing applications (UL 3374 and UL 3340 only) For motor leads and internal wiring of appliances such as refrigerating equipment, room cooler units and heat pumps where use temperatures do not exceed 125 C. Where no flexing occurs after installation or during service, a maximum temperature of 150 C is permissible Also for use as leads of transformers, motor ballasts, solenoids, etc., where the baking temperature of the windings and coils to which they are attached will not exceed 160 C Resistant to heat, moisture, ozone and chemicals Excellent low temperature flexibility down to -40 C and insulation resistance Withstands varnish dip and bake cycles for motor coil lead applications For Product Information, Quotations and Ordering Corporate Headquarters Prestolite Wire Corporation 200 Galleria Officentre, Suite 212 Southfield, MI 48034 Ph: 800.499.3132 248.355.4422 Fax: 248.386.4462 OEM Customer Service Group Prestolite Wire Corporation One Prestolite Drive Paragould, AR 72450 Ph: 800.952.3842 870.236.8141 Fax: 870.239.6139 Email: bulkwiresales@prestolitewire.com www.prestolitewire.com 2005, Prestolite Wire Corporation