C-Series. Unique Solutions for All-Indoor HVAC Projects

Similar documents
CoolSpot. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

C13-Series. Unique Solutions for All-Indoor HVAC Projects

MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

CoolSpot Engineering Guide

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

VariCool VAV Engineering Guide

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery

OmegaAir. 100% Dedicated Outside Air System (DOAS)

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Modular Indoor Systems For Effective Environmental Control

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

VertiCool Aurora Engineering Guide

C13-Series Engineering Guide

Flexible & Innovative. Cooling Solutions

FULLY SELF-CONTAINED AIR CONDITIONING WITH INDUSTRIAL DURABILITY

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

The Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

Liebert Mini-Mate2 1 To 8 Tons

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

Liebert Mini-Mate2 1 To 8 Tons

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

HVAC 101. H V A C S y s t e m s

Guide Specifications for InRow Direct Expansion

THE ULTIMATE ROOFTOP SOLUTION

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

The ultimate fresh air solution.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

Liebert. Mini-Mate2 1 To 8 Tons Overhead Precision Cooling And Humidity Control

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

Operation & Maintenance Manual

Liebert Mini-Mate2 1 To 8 Tons

Data Aire Mini Ceiling Systems 1, 1.5, 2, and 2.5 ton capacities R-410A. ISO 9001 Certified

ADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements

System Floor Mount Systems DX / Glycol / Chilled Water 6-12 Tons. High Density Presicion Cooling. Kompact.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

RHEEM PACKAGE GAS/ELECTRIC

gforce Units Data Aire and Data Temp Series

1.1 This section applies to air handling units for HVAC Systems.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

STULZ FLAiR Systems Floor Mounted Console Air Conditioners 5-17 kw / Single Circuit / DX Air / Water / Glycol. Engineering Manual

Innovent s. Direct Replacement Program. Engineered to match... your footprint, your needs.

Mini-Space EC DX and CW 4 12 kw Systems Vertical Floor Mounted, 60 Hz Data

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SECTION AIR COILS

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

SC SpotCool. 1 to 3 Tons. R407c & R410a. 2 x 4 Packaged & Split. Spot-Cooler & Ducted. eair above-the-ceiling air conditioners (ASC-L22)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

RT-OA TM Rooftop Outdoor-Air (DOAS)

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

HORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h

2 Existing Mechanical System

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance Line

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Mission Critical Air Conditioning Systems

Summary Comparison of Simulation Program Features

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

CHAPTER 4. HVAC DELIVERY SYSTEMS

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

:: welcome to the rebirth of cool The all-new Rheem Commercial Renaissance HVAC Line

RoofPak Applied Rooftop Systems

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Job Name Control Systems Description Date

Transcription:

C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects

C-Series Magna Cool Precision Cooling Package Air-Cooled Water-Cooled Water Source Heat Pump Simplified Replacement Air Conditioning The C-Series indoor horizontal air conditioner from United CoolAir is designed as a flexible indoor ducted cooling system for commercial building installation. It is ideal for replacement or renovation applications offering design engineers and contractors installation options not available on conventional off-the-shelf products. The low profile design is available in multiple cabinet sizes starting at 16 high and with a cooling capacity up to 15 tons. Out of Sight, Out of Mind The low profile, horizontal design of the C-Series tucks away easily in ceiling plenums, preserving valuable floor space. Four cabinet sizes are available with the unit mounted on channels to accommodate hanging rods for ceiling installation. C-Series units can also be slab mounted. More than Just a Commodity Air Conditioner The C-Series is the one air conditioning system that can be truly labeled flexible! It can be installed as a packaged unit or as a split system with the evaporator and condensing sections in different locations. A single condensing section can even be used with up to 3 evaporator sections, each with their own Built-to-Order, not Custom Built refrigerant circuit! Heat rejection options include air or water with the added benefit of chilled water and heat pump configurations. The C-Series can also serve as precision cooling when equipped with the optional MagnaCool package. Mention the word custom, and immediately assume expensive. Not with United CoolAir! Our units are built-to-order making them better than commodity systems but less expensive than custom built. We start with a solid, flexible platform with features added without the high cost of special manufacturing. Each tailor-made unit uses standard components and options to meet a specific operational requirement. FEATURES 1 to 15 tons Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Single Package or Splittable Multiple air path options Variable Pitch Drives Allow Adjustable Static Pressure Dual Independent Control Panels (split systems) Functionally Run Tested Prior to Shipment 2

Total Installed Cost Advantages Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to- Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3

C-Series OPTIONS Powder Coated Cabinets Electric Heat Condensate Pump (externally mounted) Upgraded Motors, Evaporator or Condenser Hot Gas Bypass Steam Canister Humidifier Protective Coil Coatings Drain Pan Overflow Switch Non-Fused Disconnects Freezestat Air Side or Water Side Economizers Double Wall Cabinet Construction (Perforated or Solid) Auxiliary Coils (Steam, Hot Water or Chilled Water) Hot Gas Reheat Head Pressure Control Valves Marvel Microprocessor Controls BMS Interface APPLICATIONS Offices Retail Spaces Schools/Universities Healthcare Buildings Restaurants Historical Buildings Industrial/Manufacturing Remote or Isolated Areas Add-on Spot Cooling Electrical Equipment Rooms Limited Access Areas MagnaCool Precision Cooling Package The C-Series is available as an Air-Cooled configuration if it has the MagnaCool precision cooling package. United CoolAir provides the MagnaCool precision cooling package for applications where tighter control of the temperature, humidity and air quality are critical. These applications may include Electronic Steam Canister Humidifier Electronic steam canister humidifier nominally rated at 2 lbs./hr. per ton of cooling provides pure, particle-free humidity to the conditioned space. The sealed canister complies with ASHRAE recommendations by eliminating open pans with standing water in the airstream. computer rooms, laboratories, telecommunication rooms or manufacturing processes. Features include humidification, electric reheat, multiple alarm switches, hot gas bypass and the Marvel S Microprocessor. Electric Heat/Reheat Magna Cool Precision Cooling Package Finned tubular heaters have proven to be reliable. They can be used for heat and/or reheat, and are safer to operate, have a long service life and are ruggedly constructed. 4

C-Series The All-Indoor Solution The splittable design of the C-Series allows for easier installation and flexibility. The system can be used as a packaged unit or as a split system with the evaporator and condensing sections in different locations up to 100 equivalent feet away. Locating the evaporator section closer to the conditioned space minimizes ductwork and reduces cooling loss for more efficient operation. Additionally, locating the condensing section near an outside wall or other suitable location reduces heat gain back to the space while reducing the cost of long duct runs. To facilitate efficient heat removal at the installation location, the C-Series can be configured for Water-Cooled or Chilled Water applications. The standard unit can also be specified as a water source heat pump. Refrigerant Line Lengths up to 100 Equivalent Feet Units are shown as split and packaged systems and are for illustrative purposes only. 5

C-Series Horizontal Self-Contained The C-Series Horizontal unit is designed as a flexible ducted air conditioning system for indoor commercial applications. It is the ideal system for replacement or renovation projects. The low profile design is available in multiple cabinet sizes starting at 16" high and with a cooling capacity up to 15 tons. Units 6 tons and higher come with multiple compressors* for staged operation, greatly reducing power consumption when full tonnage is not required. *4 and 5 ton available with single or dual compressors. Dimensions - Inches (For Standard Water-Cooled Configuration) NOMINAL TONS A B C D E F G L M AH 1 & 1-1/2 Ton Single Compressor 38-1/16 35-15/16 16 16 22-1/16 12 12 16-1/8 12 --- 2, 3 & 4 Ton Single Compressor 47-9/16 47-3/8 22 16 31-9/16 16 18 24 16 --- 5 Ton Single Compressors 47-3/8 55-3/8 27 16 31-3/8 18 23 32 16 --- 4, 5 & 6 Ton Dual Compressors 47-3/8 55-3/8 27 16 31-3/8 18 23 32 16 --- 8 Ton Dual Compressors (RDC) (1) (20) 51-7/16 70-5/8 29 16 35-7/16 20 25 37-9/16 18 --- (STD) 80-3/4 70-5/8 29 45-5/16 35-7/16 20 25 37-9/16 18 --- 10 Ton Dual Compressors (RDC) (1) (2) (3) 51-7/16 70-5/8 29 16 35-7/16 20 25 37-9/16 18 --- (STD) (3) 80-3/4 70-5/8 29 45-5/16 35-7/16 20 25 37-9/16 18 --- (ETD) 93-13/16 70-5/8 29 45-5/16 48-1/2 20 25 48 18 83-7/8 12 & 15 Ton Triple Compressors (STD) (3) 80-3/4 70-5/8 29 45-5/16 35-7/16 20 25 37-9/16 18 --- (ETD) 93-13/16 70-5/8 29 45-5/16 48-1/2 20 25 48 18 83-7/8 1. Must have rear access for service and maintenance 2. Selected refrigerant circuit options may require change in condensing section cabinet size to accommodate all requirements 3. MagnaCool packages only. RDC = Reduced Depth Condensing Section STD = Standard Depth condensing Section ETD = Extended Evaporator Section 6

C-Series Raritan Bay Medical Center Case Study Old Bridge, NJ The Challenge An engineer was required to do a surgical suite with spaces requiring about 2000 cfm. The application required temperature and humidity control. Problem was they were limited in space, it needed to be DX and there was a significant distance between the evaporator and condenser locations. In addition, final filters required a higher static on the system MagnaCool Option For projects that require precision temperature and humidity control, United CoolAir offers the Magna- Cool close tolerance options. This package includes a microprocessor control, clean and efficient electronic steam canister humidifier and electric reheat as standard components. The MagnaCool bundled option sets are available on several product families providing flexibility for your diverse applications. The Solution We solved their requirements with our horizontal Magnacool unit. This unit offers heating, cooling, reheat dehumidification and an integral humidifier with distributor. The unit was configured with an air foil fan to do up to 3 esp and full DDC controls including a BMS interface card. The long refrigerant lines were addressed with factory installed refrigerant specialties including liquid line solenoid, accumulator, quench valve, oil separator and receiver tank to allow mechanical cooling all year round with the safety of a 200 equivalent feet refrigerant run. Total Installed Cost Advantage Eliminates the need for Expensive Equipment, Rigging, or Permits Avoids Rooftop or Roof Penetration There is no Field Piping, Brazing, Evacuation, or Charging Required Lessens Excessive Downtime when Replacing Old Systems Does Not Require Architectural Damage to Building Will Not Compromise in Performance with Built-To-Order Design Weather will Not Damage Equipment Reduces the Possibility of Theft or Vandalism Refrain from Field Testing of Installed Product Visit www.unitedcoolair.com or call the factory at 717-843-4311 for more information 7

Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, 12-90 Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order Alpha Aire 100 500 CFM OmegaAir Horizontal and Vertical 100% Outside Air 150 3000 CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA 17403 Phone: 717-843-4311 Fax: 717-854-4462 email: uca@unitedcoolair.com web: www.unitedcoolair.com Copyright by United CoolAir Corporation 2017. All rights reserved. Manufacturer reserves the right to make changes without notice. 10.1-SB (0917)