Digital Marine Exhaust Temperature Alarm

Similar documents
ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Intelligent Security & Fire Ltd

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

ARGO (Technical Support) 2201 Dwyer Avenue Utica, NY (Corporate Sales) 85 Middle Road

THX-DL Data Logger USER & INSTALLATION MANUAL V

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Guide. Stainless Steel Filter Housing Heater

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

BC-4000 Bilge Monitor/Controller Installation Manual

DYGIZONE GJD910 Lighting Controller & Enunciator

Analog Room Pressure Monitor RPC Series

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

AXS Strikemaster Engineering Manual

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

Introduction. OM-THA2

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

DC 60 & DM 60 displays

VIDEO CONTROLS LIMITED

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

DOL 31 Speed Controller Technical User Guide

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Intelligent Security & Fire Ltd

Fire Command Keypad. XR5 User s Guide

MC 31 Speed Controller Technical User Guide Code no GB

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

Beacon 800 Gas Monitor Operator s Manual

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Explorer F210 Fuel Instrument Installation and Operation Manual

INSTALLATION & USER MANUAL

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Installation and User Instructions

Control Application. Supplement - ACVMax

Stratomaster Smart Single

INSTRUCTIONS OPTICLIMATE PRO3 SPLIT. Please take note of: - High temperature protection on page 9 - Clear alarm history on page 15

8700 S-linkControl Panel

SAFIRE 2000A FUEL OIL HEATER INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

STEAMPRO. Steam Generator Troubleshooting and Service Guide

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

380 SERIES REMOTE SIREN ETSA380R

MV Hydro 5. MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed MV Heating UK Ltd

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

prestige Control Application Supplement - ACVMax

- Data Brochure Steam Control 279

Pioneer-R16 Gas Monitor Operator s Manual

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

AFA1000/1 MK3 Airflow Monitor

RC-2000 Thermostat Installation Instructions

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

RMS-I-DE-01 Smoke Detector

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

CONTROLS INSTRUCTIONS MANUAL ENGLISH

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

MVE TS Controller (Touch Screen)

EasyTronic III MANUAL SERVICE

Dual Axis Inclinometer - Active

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

EXC-450 User s Manual

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

THX-DL Data Logger USER & INSTALLATION MANUAL V Refrigeration

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

REMOTE CONTROL FOR CHILLER MYCHILLER

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

Antares Warewash Dispensing System

OPERATING INSTRUCTIONS

EST User Manual. (Please read this manual carefully before using)

Owners Manual Operating Instructions Patent # 7,081,811

Instruction Manual Machine P/N: # & #

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

Dryer Controller M720

Memcom Emergency Telephone

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Manual# User s Manual. DCU 410/408 Engine Control Unit RP 410 Remote Panel FW 2.3

MV Hydro 9 Diesel Powered Water Heater Instruction Manual Ed. 2.00

ORP (mv) Controller Model: ORP-XP2. UP DOWN ENTER Time & Date Main Menu Alarm Reset

DC200 Digital Dispenser Operating Manual

F AN-ASPIRATED RADIATION SHIELD

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

RS Pro Infrared Temperature Sensor

testo 315-1/2 Instruction manual 99 Washington Street Melrose, MA Phone Toll Free

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

ZSC100 Gas Detection and Alarm System Controller

Skipper's Mate. Sensor Testing. Version December Table of Contents

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

prestige Control Application Supplement - TriMax

EW 40 Wireless Fan Control

Antares Warewash Dispensing System

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

1. Functions of GPS locator ETLOC-30S 3

Transcription:

Digital Marine Exhaust Temperature Alarm Model: SM007D/S INTRODUCTION COMPONENTS Marine water cooled exhaust systems are designed to withstand temperatures of up to about 120 C. However the exhaust gases from the engine may reach in excess of 450 C. In order to protect the exhaust system it needs a continuous flow of cooling water from the engine, should this flow be interrupted by debris being sucked into the intake or by a problem with the water pump or simply forgetting to open the seacock then the exhaust temperature will start to rise immediately. Depending on the extent of the blockage the increased temperature can cause seriously damage the exhaust system and water lock. The engine water temperature and/or oil temperature alarms will eventually alert you, however there can be a considerable time lag especially if the engine has been started from cold which means that damage may already have be done. In order to protect the exhaust components and provide the earliest possible warning you need measure the temperature INSIDE the exhaust. Systems which measure the outside temperature will inevitably be delayed as the heat has to make its way through the exhaust components. This product uses a quality stainless steel in-exhaust probe containing a platinum wire sensor. The control unit allows the exhaust temperature to be monitored and the alarm point set to a temperature appropriate for your engine. Note: Exhaust temperature alarms protect the exhaust system components not the engine; you will still need the engine water/oil temperature alarm. SENSOR INSTALLATION The sensor has been designed so that it can be fitted without the need to dismantle any of the exhaust system components. Cut the steel band to size making sure you leave enough overlap. Make sure the cut end has no burrs else it will be difficult to feed through the worm drive. Assemble the sensor as shown, the shake proof washers should go either side of the steel band, tighten the nuts firmly. No thread should protrude below bottom nut (see picture). Select a point on the hose about 150mm downstream from the water injection point. Drill a 4mm hole avoiding the steel reinforcement rings (If you have a horizontal hose it is preferable to mount the sensor on the top). Push the sensor through the hole into the exhaust pipe and secure firmly. The sealing O ring should make a good waterproof seal; if in doubt add a little silicon sealant. Use a cable tie to secure the cable to the hose clamp as shown. 1 P a g e

INSTALLATION The Sensors, power and external alarm connect via a junction box which then connects via a single cable to the display unit. The junction box would be situated close to the engines. Dual engine wiring is as follows Display Cable Single engine wiring is as follows 1. +12v from port engine ignition 1. +12v from engine ignition 2. +12v from starboard engine ignition 2. No connection 3. External alarm (positive) 3. External alarm (positive) 4. Ground wire 4. Ground wire 5. Sensor 1 (port) 5. Sensor 1 6. Sensor 1 / Sensor 2 common 6. Sensor 1 7. Sensor 2 (Stbd) 7. No Connection The display is connected to the junction box with a 5 metre cable that is supplied with the kit. To connect the cable to the display unit; open the back of the display and plug the cable in as shown in the picture below. Make sure you push the cables in until they click, test by pulling gently on the cable that they are locked in position. Should you require a longer length cable then these are available from Silicon Marine or from a local electrical store. The cable is a standard RJ12 6 core CROSSED cable which is often used for telephone extensions and should be available locally. External Alarm The external alarm is connected between pin 3 (+) and pin 4 (-) An additional external is supplied with the kit for mounting at any convenient location and is often mounted on the outside of the junction box. If you wish to add your own alarm (or even a third alarm) then please observe the following; use a 12v piezo self-resonating sounder with a current consumption of less that 500mA, do not use electro mechanical buzzers as these often cause electrical interference. A low power relay may be connected to the alarm output if required. Fuses; the control unit contains internal self-resetting fuses on the supply and alarm output, therefore is does not require external fuses. Should the internal fuse fail it will be automatically reset when the overload is removed or the power turned off. Dual Display An additional display unit may be connected and mounted at a second steering position. To connect the second unit simply insert a 3 way RJ12 splitter into the cable between the first display unit and the junction box. When power is applied both displays will show the same information and changes to the configuration on one display will automatically be sent to the other. The dual display kit contains the splitter and additional cable. 2 P a g e

INITIAL SYSTEM TESTING Apply power to the unit by switching on the ignition, the display should light up and the screen display the exhaust temperature as shown in the pictures below). There is no on/off button so the unit will be on whenever the ignition is on. If one of the sensors displays the message Sensor Error then check the connections going to the sensor are correct. Sensor 1 (port) is between connector pins 5 & 6 and Sensor 2 (stbd) is between 6 and 7. If this looks correct check the resistance of the sensors, it should read between 1000 and 2000 ohms. Check that the alarms sound by selecting the Alarm Test option from the menu. To access this hold down the UP Arrow for 3 seconds then release the button, the screen will then display a menu. Scroll down the menu using short presses on the Down Arrow key to select Alarm Test then press the Up Key for about 1 second (a longer press on the key acts like an ENTER key). The alarm will now sound, check that both the displays internal alarm and external alarms sound. To turn off the alarm press any key. The Exhaust alarm is now ready to be used, the initial alarm temperature is set to 95 c (203 f) which is probably higher than it needs to be and this can be adjusted after the first trial with the engine running. Setting the alarm temperature It is important that you adjust the alarm temperature following the first trial with the engine running. If the temperature is set too high then the response to a cooling water loss will be slower than it needs to be and if set too low will possibly give false alarms when the engine is running hard. The display keeps track of the maximum recorded temperature for each engine, after running the engine for sufficient time to bring it up to its normal working temperature, add 20 c (68f) to the maximum temperature and use this for setting the alarm temperature. (Each engine has its own alarm setting). See the section below for how to navigate the menus and set the alarm temperature. When the alarm sounds it can me momentarily silenced by pressing any key. If the temperature is still high after 2 minutes then the alarm will sound again. The temperature must fall 5 (9 f) below the alarm temperature for the alarm to turn off. Display symbols Dual Display Alarm temperature, audible alarm enabled Single Display Temperature graph displaying temperature over time. The line represents the alarm point above which the alarm will sound. Alarm temperature, audible alarm disabled Maximum recorded temperature Led indicators show status for each engine sensor Green indicates = OK, Steady Red = Sensor Error Flashing red = Temperature Alarm 3 P a g e

Function key operation The display unit has two function keys UP and Down and depending on how long the key is pressed determines its function. With a short press (less than a second) the keys performs like up/down buttons for selecting items from a menu. A longer press (1 second or more) on the UP key acts like an ENTER key for selecting an item, whilst a longer press on the DOWN key acts like an ESC key for exiting. In addition to this when the unit is in its normal operation mode and displaying temperatures a three second press on the UP key is required to enter the setup menu. On the dual display unit a short press on the UP key scrolls through single sensor display mode, this allows you to see the maximum temperature which is only displayed in this mode. Menu options When the unit is in its normal operation mode and displaying temperatures the System Menu can be accessed by pressing the UP button for three seconds then releasing the key. To exit the menu or return to a previous menu press the down button for at least 1 second this acts like an ESC key. The menu structure is as shown below. Example; to select Sensor 1 alarm temperature first select Sensor 1 which will then display a sub menu, then select Alarm Temp. Main Menu Sensor 1 o Alarm Temp (Temperature at which the alarm will sound) o Alarm Enable (Disables/enables the audible alarm) o Name (Change the displayed name for the sensor, i.e. Main/Aux/Gen etc.) Sensor 2 o Alarm Temp o Alarm Enable o Name System Config o Backlight (Maximum backlight brilliance, it will auto-dim at night) o Night Threshold (Determines when unit dims display for night mode) o Contrast (Display contrast setting) o Update Rate (Update rate for the graph, 15/30/60 seconds per division) o Units (Centigrade / Fahrenheit) o Sensor Enable (Disable a sensor, the display will no longer show the sensor nor will the alarm sound) (Not available on single sensor model SM007S) Reset Stats (Resets the maximum sensor temperature display to current temperature also resets the graph) Alarm Test (Tests the internal and external alarm, press any key to cancel) Dual display functionality Two display units may be operated in parallel giving you the ability to have a second display and alarm at an alternate steering position. When operated together you only need one set of temperature sensors, the units will determine between themselves which will be master and which will be the slave. The master unit will take the temperature readings and pass them digitally to the slave. Both units appear to operate identically to the user and any changes made to the configuration settings on one unit will automatically be passed to the other* If a master unit were to fail or be turned off then the slave unit will automatically take over the role. A small flashing dot is the only indication which unit is acting as the master, if the dot is in the upper left corner of the display it is master. * Except brightness, contrast and night threshold 4 P a g e

Spares Part Number SM007/D SM007/S SM007/A SM5002 SM5006 SM5016 Description Complete Dual Marine Exhaust Temperature Alarm Kit Complete Single Marine Exhaust Temperature Alarm Kit Slave display unit Temperature Sensor Temperature Sensor Retaining Clip 10m Extension cable Specifications Supply Voltage: 9 30v DC, 28mA (no alarm) 80mA internal alarm sounding. Sensor Temperature range: -20 - + 250 C (display will only show 0-200 C) Temperature probe: Marine grade stainless steel with platinum wire sensor 1.0m cable rated at 260 C Calibration: +/- 1 C self-calibrating. Alarm range: 0-199 C user adjustable in 2 C steps. Alarm Output: +12v out when alarm sounds, 0.5A max. Fuse: Internally fused with self-resetting fuses www.siliconmarine.com support@siliconmarine.com Tel: +44 (0)1843 482509 Designed and Manufactured in the United Kingdom 5 P a g e