TRADE PRICE BOOK EFFECTIVE DATE MAY 15, 2014

Similar documents
FTIIIC-10. Domestic Hot Water Heaters and Boilers

Domestic Hot Water Heaters and Boilers FTIIIC-6

FXLF-9. High Efficiency Water Heaters and Boilers

BEACON/MORRIS RBD SERIES INFRARED RADIANT HEATER

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

INFRARED RADIANT HEATERS

First Year Limited Warranty for Residential Use Condensing Water Boilers (Includes Heat Exchanger and Component Parts)

FXLF-4. High Efficiency Water Heaters and Boilers

DIVISION FINNED WATER-TUBE BOILERS

PB HEAT, LLC TRADE PRICE LIST EFFECTIVE JUNE 1, 2018 P-18

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

Peerless Boilers. Series MI. Residential Gas Boilers

HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES

CONDENSING WATER BOILERS. (Models VLT , Q VX ,

KN2/4 SERIES MASTER SPECIFICATION

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Now Available with PVC & Polypropylene Vent Configurations

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

DIVISION FINNED WATER-TUBE BOILERS

SERIES 19A. mith PRESSURIZED WET BASE

Hubbell NX500 High Efficiency Gas Condensing Water Heater

KN-SERIES GAS-FIRED DIRECT VENT CAST IRON BOILERS KN-6 KN-10 KN-20

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

DIVISION FINNED WATER-TUBE BOILERS

Service Parts, Kits and Accessories

WIRING DIAGRAMS R410A MODELS PAC 2OAC/2OACH CAC OWC PWC

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Project Name: Location: Engineer: Contractor: I. GENERAL

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

KN-SERIES MASTER SPECIFICATION

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

GB Condensing Gas Boiler

TWIN-FLOIII HEATER INSPECT THE SHIPMENT IMMEDIATELY WHEN RECEIVED TO DETERMINE IF ANY DAMAGE HAS OCCURRED DURING SHIPMENT.

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Phantom-X 399C/500C. Residential High Efficiency Gas Boilers PHNTM399C, PHNTM500C Submittal Sheet. Wholesaler Job Name Mechanical Contractor

23 11/32 [593] Ø8 AIR INLET [203] 6 5/8 [168] 44 3/4 [1137] TOP VIEW ASUB-31 REV. B 38 11/16 [983] 3 NPT BOILER OUTLET WIRING CONNECTIONS 1 NPT 1 NPT

G315/6 Cast Iron Boiler

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

Commercial Boilers and Domestic Water Heaters APG-5

G315/5 Cast Iron Boiler

mith Mills Smith Mills 6500A 6500A-4 OIL OR GAS CAST IRON BOILER/BURNER CAST IRON

G515/7 Cast Iron Boiler

Raptor 320HB & 399HB Submittal Sheet

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Suggested Specifications Prestige Excellence 110

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

GB Condensing Gas Boiler

G615/11 Cast Iron Boiler

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

FLEXCORE SERIES MASTERSPEC

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

WHAT TO DO IF YOU SMELL GAS

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

H 2 HYDRONIC BUFFER TANKS INSTALLATION, OPERATION & MAINTENANCE MANUAL

CSD-1 COMMERCIAL BOILER CONTROLS

H 2. Hydronic Buffer Tanks INSTALLATION, OPERATION & MAINTENANCE MANUAL MODELS

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Series EC/ECT Residential - Packaged or Knockdown Natural Draft Venting Flame Retention Burner Steam or Hot Water Boilers Optional Tankless Coils

Standard Equipment: Water. 30 PSI Safety Relief Valve Temperature-Pressure Gage BOILER RATINGS. Series WBV. Steam, MBH 3

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Multiple Boilers Electro TS Series Application EB-C-STG5

GB Condensing Gas Boiler

Is a heating protection plan really worth it? Decide for yourself!

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

FINNED WATER-TUBE POOL HEATERS

ClearFire - Hydronic Startup Report

mith Mills 4500A Smith Mills 4500A 4500A-3R OIL, GAS OR COMBINATION GAS/OIL COMMERCIAL BOILER/BURNER CAST IRON

Boiler & Water Heater

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

Replacement parts EG/PEG

INSTALLATION AND OPERATION INSTRUCTIONS

Trade Price Book - 816

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

INSTALLATION INSTRUCTIONS

Automatic Circulating Water Heaters

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

High efficiency, cast-iron gas boiler

INDOOR/OUTDOOR, HOT WATER HEATERS AND HYDRONIC HEATING BOILERS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

STERLING RSG SERIES INFRARED RADIANT TUBE HEATER

Transcription:

HTP-7-CDN TRADE PRICE BOOK EFFECTIVE DATE MAY 15, 2014 TABLE OF CONTENTS TERMS AND CONDITIONS OF SALE... 2 FREIGHT POLICY... 2 EXPLANATION OF RATINGS... 3 COMMERCIAL BOILERS GAS-FIRED KN SERIES (Water)... 4-6 RESIDENTIAL BOILERS GAS-FIRED HWX (Water)... 7 HVX (Water)... 7 VGX (Steam)... 8 HEATNET BRIDGE ADDRESSING WORKSHEET... 9 WARRANTIES... 10-12 7555 TRANMERE DRIVE MISSISSAUGA, ONTARIO L5S 1L4 CANADA (905) 670-5888 FAX (905) 670-5782 www.knseries.com

GENERAL TERMS AND CONDITIONS OF SALE All orders are subject to acceptance by the factory. No liability shall be incurred by Mestek Canada if manufacture or delivery is prevented or delayed by strikes, fi res, delays of carriers or other delays unavoidable or beyond its reasonable control or by inability to obtain materials. Prices quoted herein supersede all prior price lists and are subject to change without notice. Prices are TAXES EXTRA, any taxes which may be payable on the manufacture, sale or delivery of the merchandise covered by this price book will be billed to the buyer. An order for items which total less than $25.00 will be shown on the invoice at $25.00 minimum. PAYMENT: Terms are net 30. A fi nance charge of 1-1/2% per month shall be imposed for indebtedness for which payment is not received within 30 days. In the event Buyer does not pay within the terms of this agreement, all collection costs incurred by Manufacturer, including attorney and court costs, will be paid by Buyer. FREIGHT TERMS: Prices quoted herein are F.O.B. our Mississauga plant. Freight will be allowed as follows: Full freight allowed on single shipments of 40,000 lbs. or more. Freight not allowed on shipments under 40,000 lbs. Shipping weights supplied in the price book are approximate, for buyer s convenience only, and are not guaranteed. We reserve the choice of transportation facilities and shipping point. DELIVERY: Delivery to the initial carrier shall constitute delivery to the buyer. The seller s responsibility ceases upon delivery in good order to such carrier, and all merchandise is shipped at the buyer s risk. The buyer is urged to examine all deliveries before signing transportation receipts. If merchandise is visibly damaged, the buyer should insist that written confi rmation of the damage be noted on the freight bill by the agent of the carrier. If damage is discovered after unpacking, the carrier should be notifi ed at once so that inspection can be made and the claimed damage substantiated by the carrier. RETURN MATERIAL POLICY: No material, whether new, used or alleged defective, may be returned without prior written authorization from the company. New and used equipment of current manufacture may be returned, freight prepaid after written authorization has been received. In such cases, credit will be allowed, less 25% handling and/or inspection charges if the equipment is received free of shipping or other damage. When a defect occurs in the heat exchanger unit only, the complete boiler will not be accepted for return. Material arriving at Mestek Canada plants not properly tagged will be refused. PROCEDURE FOR OBTAINING AUTHORIZATION TO RETURN MATERIAL: The customer or Representative will request an Authorization to Return Material tag. A separate tag will be issued for each item returned. All information requested on the tag must be supplied, if applicable, in order that the request may be processed promptly. The original tag will be torn off and retained by the customer for his records. The remaining two copies will be returned to the factory, along with the returned material. WARRANTY CLAIMS: Claims made under warranty on equipment thereof manufacture by Mestek Canada after the warranty has expired will be considered on the basis of 6 month shelf time prior to the date of installation. Claims made on equipment of parts thereof manufactured by Mestek Canada after this time frame will only be considered after claimant furnishes notarized bill of sales showing that the date of installation was within the warranty period. LABOUR CLAIMS AND ALLOWANCES: As specifi ed in the limited warranty, no labour allowances will be made for the replacement of warranty materials claimed defective. FREIGHT POLICY FULL FREIGHT ALLOWED TRUCKLOAD SHIPMENTS (Units Only) Shipping & Handling Charges Per Order and Ship to Location Net Value Single / Combined Order Zone 1 Zone 2 Zone 3 Full Freight Allowed at $100,000 $110,000 $125,000 Zone Breakdown ON, QC SK, MB BC, AB 2

EXPLANATION OF RATINGS BOILERS RATING CSA INPUT Firing rate in BTU/hr. for atmospheric gas boilers based on CSA certifi cation test procedures. AHRI Input Firing rate in gallons per hour of oil or BTU/hr. of gas in accordance with Hydronics Institute test procedures. DOE Heating Capacity Heat output of the boiler based on standard test procedures prescribed by the United States Department of Energy. Applies to boilers under 300,000 BTU/hr. input. CSA Gross Output Heat output of the boiler based on tests conducted at the CSA Laboratory. Applies to atmospheric gas boilers with inputs of 300,000 BTU/hr. and over. AHRI Gross Output Heat output of the boiler based on tests conducted in accordance with Hydronics Institute procedures. Applies to oil, gas and gas-oil boilers with power burners when input is 300,000 BTU/hr. and over. NET AHRI Ratings The DOE heating capacity, CSA gross output, or AHRI gross output less deductions for piping and pickup. The amount of the deduction is determined by the AHRI Testing and Rating Code for Heating Boilers. Certified Ratings Ratings when boiler is fi red with special burners and/or under fi ring conditions other than stipulated by the AHRI code. SELECTING THE BOILER Boilers should be selected based on the Net AHRI rating when piping and pickup factors are considered normal. Net AHRI ratings are shown in BTU/hr. for water and steam and in square feet of steam. To select residential boilers for gravity hot water systems, fl oor panel systems, hot water or steam systems with larger than normal piping and pickup factors, and replacement boilers on hot water or steam systems with old style radiation and large piping, see chart below for piping pickup factors. ASME CONSTRUCTION All Advanced Thermal Hydronics boilers meet the requirements of the ASME boiler and pressure Vessel Code, Section IV, Heating Boilers. The Net AHRI Steam Ratings shown are based on a piping and pickup allowance as follows: Net AHRI Piping Net AHRI Piping Steam Rating and Steam Rating and 1000 BTU Pickup Factor 1000 BTU Pickup Factor 22.5 thru 940.7 1.333 1143.5 thru 1151.1 1.310 942.9 thru 950.4 1.332 1153.6 thru 1162.7 1.309 952.7 thru 960.2 1.331 1165.1 thru 1174.3 1.308 962.4 thru 968.4 1.330 1176.7 thru 1185.9 1.307 970.7 thru 976.7 1.329 1188.4 thru 1196.0 1.306 978.9 thru 984.9 1.328 1198.5 thru 1207.7 1.305 987.2 thru 994.7 1.327 1210.1 thru 1219.3 1.304 997.0 thru 1003.0 1.326 1221.8 thru 1231.0 1.303 1005.3 thru 1011.3 1.325 1235.0 thru 1241.2 1.302 1013.6 thru 1021.1 1.324 1245.2 thru 1251.3 1.301 1023.4 thru 1029.5 1.323 1255.4 thru 1264.6 1.300 1031.6 thru 1037.8 1.322 1268.7 thru 1274.8 1.299 1040.1 thru 1047.7 1.321 1278.9 thru 1288.1 1.298 1050.0 thru 1056.1 1.320 1292.2 thru 1301.5 1.297 1058.4 thru 1064.4 1.319 1305.6 thru 1314.8 1.296 1066.8 thru 1074.4 1.318 1318.9 thru 1328.2 1.295 1076.7 thru 1082.8 1.317 1332.3 thru 1344.7 1.294 1085.1 thru 1092.7 1.316 1348.8 thru 1364.3 1.293 1095.1 thru 1102.7 1.315 1368.4 thru 1387.0 1.292 1105.0 thru 1111.1 1.314 1391.2 thru 1412.9 1.291 1113.5 thru 1121.1 1.313 1417.1 thru 1445.0 1.290 1123.5 thru 1131.1 1.312 1449.2 thru 1501.9 1.289 1133.5 thru 1141.1 1.311 1506.2 and over 1.288 The Net AHRI Water Ratings shown are based on an allowance of 1.15 for piping and pickup. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. 3

KN SERIES KN-2 & KN-4 GAS-FIRED MODULATING BOILERS (NATURAL GAS/PROPANE) CRN M1500.5C Boiler Model KN-2 KN-4 Part Number Nat. Gas/LP BM-1030 BM-1032 Input 199 399 CSA Input MBH Output 184 369 *Standard 30 PSI 100 PSI max allowed. DOE AFUE 92.7% 92.7% Relief Valve Press 30 PSI* 30 PSI* Ship Wt. Lbs. 580 780 Trade Price $6,845 $11,875 ENERGY STAR RELIEF VALVE AND ACCESSORY PACKAGE (No Charge when ordered with Boiler) Boiler Model Part Number 30 PSI 50 PSI KN-2 70-1462 70-1463 KN-4 70-1466 70-1467 75 PSI 100 PSI KN-2 70-1464 70-1465 KN-4 70-1468 70-1469 KN-2, KN-4 STANDARD FEATURES Condensing Boiler Air/Fuel Coupled Commercial Grade Cast Iron Sections Durable Insulated Jacket Direct Vent On-Board Recirc. Pump Unique Down Fire Design Low Nox Emissions Comprehensive SmartCycle Control Capable of Self Adjust for Altitude Firing Single or Multiple Boilers Reusable Air Filter IAR Indoor Air Reset (Up to 8 Zones with Direct Spark Ignition Domestic Hot Water Priority) Flame Rod Rectifi cation Opt. Outdoor Air Reset Steel Base Metal Mesh Burner Condensate Trap Communication Module - Modbus Factory Fire Tested Communication Cable 25' Return/Supply Boiler Sensor (10K) 3" w.c. Minimum Gas Pressure T & P Gauge 5:1 Modulation Air Vent B & G #98 OPTIONAL KN ACCESSORIES Order code Description Trade Price 02-4285 Well 2 1/2"...$ 43 02-4280 Outdoor Sensor w/enclosure (one required for each master boiler)... 47 02-4283 Common Header Supply Sensor 10K (less well) (one required for each master boiler)... 36 BACNet & LonWorks for KN-2 & 4: 02-4350 Protocarrier... 446 02-4352 BACNet IP Protocessor*... 1,512 02-4353 BACNet MSTP Protocessor*... 1,512 02-4351 LonWorks Protocessor*... 1,683 40-5409 Communications Cable 25'... 24 *Must complete HeatNet Bridge Addressing Worksheet on page 9. 4

KN-SERIES GAS-FIRED MODULATING BOILERS CRN M1500.5C Boiler Model Nat. Gas LP Gas Dual Fuel Input MBH CSA Output MBH Ship WT. (Lbs) Trade Price KN-6* BM-1082 BM-1083 600 556 1040 $20,685 KN-6* BM-1120 600 556 1140 29,360 KN-6* Knockdown BM-1084** 1240 22,265 KN-10* BM-1086 BM-1087 1,000 927 1400 28,085 KN-10* BM-1121 1,000 927 1500 36,760 KN-10* Knockdown BM-1088** 1600 29,665 KN-16 BM-1036 BM-1037 1,600 1,483 2160 39,665 KN-16 BM-1122 1,600 1,483 2260 48,340 KN-16 Knockdown BM-1034** 2360 41,245 KN-20 BM-1075 BM-1076 1,999 1,853 2500 44,525 KN-20 BM-1123 1,999 1,853 2600 53,200 KN-20 Knockdown BM-1077** 2700 46,105 KN-26 BM-1038*** BM-1039*** 2,600 2,410 3000 54,630 KN-26 BM-1124 2,600 2,410 3100 63,305 KN-26 Knockdown BM-1035** 3200 56,210 RELIEF VALVE AND ACCESSORY PACKAGE (No Charge when ordered with Boiler) Boiler Model Part Number 30 PSI 50 PSI KN-6 70-1450 70-1451 KN-10 70-1454 70-1455 KN-16 70-1458 70-1459 KN-20 70-1458 70-1459 KN-26 70-1476 70-1477 KN-30 70-1476 70-1477 75 PSI 100 PSI KN-6 70-1452 70-1453 KN-10 70-1456 70-1457 KN-16 70-1460 70-1461 KN-20 70-1460 70-1461 KN-26 70-1478 70-1479 KN-30 70-1478 70-1479 KN-30 BM-1048*** BM-1049*** 3,000 2,781 3500 63,475 KN-30 BM-1125 3,000 2,781 3600 72,150 KN-30 Knockdown BM-1033** 3700 65,055 * Flow Switch only applicable on applications of 30 gpm or higher. Less than 30 gpm order fl ow switch to ship loose for fi eld installation in a 2" tee. Note on order if less than 30 gpm. ** Must specify NG or LP. *** Must specify voltage 208V or 230V. CSD-1 compliance must be specified on purchase order... If a CSD-1 data report is required order using part number 22Z-CSD1 at $25 NET per unit. Please note required state at time of order placement. N/C 5

KN-6, KN-10, KN-16, KN-20, KN-26 and KN-30 STANDARD FEATURES Factory assembled cast iron heat exchanger Insulated jacket Air fuel coupled with modulating Dungs gas valve Flame safeguard control (Honeywell RM7800) Interrupted spark ignition CSD-1 compliant gas train CSD-1 compliant LWCO Full linear modulation Cabinet mounted electrical components Vacuum fl uorescent operating status display Flue adapter with analyzer probe hole Metal mesh burner Flow switch mounted Manual reset high limit Safety pressure relief valve (must specify) UV fl ame rectifi cation Condensate drain with fi ttings Variable speed blower Temperature pressure indicator Air vent TACO 409 High gas pressure switch (KN-26/30) HeatNet integrated boiler management system Communication board Return header sensor Communication card which allows for: Boiler to boiler communications Firmware updates Connections to building management systems using Modbus protocol BOILER CONTROL STANDARD FEATURES Outlet supply sensor Modbus protocol for building management system communications OPTIONAL KN ACCESSORIES Order code Description Trade Price 02-4886 High Gas Pressure Switch (Manual Reset)...$ 185 02-4263 Keyboard Display Module Honeywell S7800A... 814 CONTROL 02-4280 Outdoor Sensor w/enclosure (one required for each master boiler)... 47 02-4283 Common Header Supply Sensor 10K (less well) (one required for each master boiler)... 36 02-4285 2 1/2" Well... 43 02-4286 4" Well... 43 02-4281 Strap-on Sensor (10K)... 38 40-5408 USB Cable for HeatNet revisions... 18 02-4352 BACnet IP ProtoCessor*... 1,512 02-4353 BACnet MSTP ProtoCessor*... 1,512 02-4351 LonWorks ProtoCessor*... 1,683 02-4354 Metasys N2... 1,512 *Must complete HeatNet Bridge Addressing Worksheet on page 9. ISOLATION VALVE WIRING - Mounted BM-1095-6 KN-6... 60 BM-1095-10 KN-10... 65 BM-1095-20 KN-20... 70 BM-1095-30 KN-16, 26 & 30... 75 FREEZE PROTECTION KITS: (Includes Damper, Relays and Factory Wired Damper Harness) BM-1545 6" Damper Kit... 465 BM-1546 8" Damper Kit... 465 BM-1547 10" Damper Kit... 465 BM-1548 12" Damper Kit... 465 BM-1549 14" Damper Kit... 465 VOLTAGE OPTIONS: 15-00102-001 Pump Contactor (whirlwind only)... 272 Option Part Number Size List Add Boiler Voltage Package (available mounted ONLY) 208/2 20-240V 1PH w/.75hp Pump Starter BM-1116-0.75 $580 w/ 1HP Pump Starter BM-1116-1 $580 208/220-240V 3PH BM-1113 16-20 $390 w/.75hp Pump Starter BM-1113-0.75 $855 w/ 1HP Pump Starter BM-1113-1 $910 208/220-240V 3PH w/ 1HP Pump Starter BM-1112-1 $550 w/ 1.5HP Pump Starter BM-1112-1.5 26-30 $605 w/ 2HP Pump Starter BM-1112-2 $630 Boiler Voltage Package (available mounted or shipped loose) 600V 3PH BM-1115 $1,895 w/.75hp Pump Starter BM-1115-0.75 16-20 $2,365 w/ 1HP Pump Starter BM-1115-1 $2,545 600V 3PH BM-11110-2 $2,875 w/ 1HP Pump Starter BM-1111-1 $3,310 26-30 w/ 1.5HP Pump Starter BM-1111-1.5 $3,525 w/ 2HP Pump Starter BM-1111-2 $3,525 6

HWX/HVX SERIES STANDING PILOT/SPARK IGNITED ATMOSPHERIC GAS-FIRED/WATER BOILER 70 to 195 MBH Input; 30 psi ASME HWX Boiler Model HWX-70 HWX-105 HWX-140 HWX-175 HWX-195 Natural Gas/LP Ratings (MBH) Net AHRI A.G.A. Input Heat Cap. Rating (MBH) 70 105 140 175 195 58 86 115 143 160 50 75 100 124 139 *A.F.U.E. % 82.2 82.1 82.0 82.0 82.0 *A.F.U.E. listed with intermittent ignition and vent damper. Intermittent Pilot w/circulator Nat. Gas BM-8735.1 BM-8736.1 BM-8738.1 BM-8739.1 BM-8740.1 Prop. Gas BM-8742.1 BM-8743.1 BM-8745.1 BM-8746.1 BM-8747.1 Trade Price $2,345 2,513 2,950 3,179 3,496 Ship Wt. (Lbs.) 282 353 428 479 568 HVX Natural Gas/LP Ratings (MBH) Boiler Model A.G.A. Input Heat Cap. HVX-70 HVX-105 HVX-140 HVX-165 70 105 140 165 58 87 116 136 50 76 101 118 *A.F.U.E. listed with intermittent ignition. Net AHRI Rating (MBH) *A.F.U.E. % 82.1 82.0 82.0 82.0 Intermittent Ignition Nat. Gas Prop. Gas Trade Price BM-8711.1 BM-8712.1 BM-8714.1 BM-8715.1 BM-8716.1 BM-8717.1 BM-8719.1 BM-8720.1 $2,255 2,389 2,604 2,900 Ship Wt. (Lbs.) 302 352 414 468 STANDARD EQUIPMENT Completely packaged and wired gas hot water boiler. Cast iron sections, steel push nipples Deluxe insulated metal jacket with removable front panel Burner base with high temperature insulation board and burner tubes Integral fl ue collector and draft diverter A.S.M.E. pressure relief valve Taco 007 circulator Temperature pressure gauge Brass hose end drain valve Automatic vent damper (HWX) Safety spill switch (HWX) Flame rollout safety switch High limit and control center Pressure Switch (HVX) Inducer (HVX) Honeywell intermittent ignition 7

VGX SERIES PACKAGED GAS-FIRED STEAM BOILER 74 to 238 MBH D.O.E. Heating Capacity - Natural or Propane Gas VGX AHRI Intermittent Pilot Water Approx. Boiler A.G.A. D.O.E. Net Ratings Conent Shipping Nat. Gas L.P. Gas Trade Steam Weight **A.F.U.E. Model Input Capacity Sq. Ft. MBH Price (Gallons) (LBS) % VGX-88 88.5 74 233 56 BM-9374 BM-9381 $2,688 9.3 465 83.0 VGX-118 118.0 98 308 74 BM-9375 BM-9382 3,064 9.3 465 82.6 VGX-147 147.5 123 383 92 BM-9376 BM-9383 3,300 10.8 576 82.6 VGX-177 177.0 147 458 110 BM-9377 BM-9384 3,540 10.8 576 82.4 VGX-206 206.5 171 533 129 BM-9378 BM-9385 3,959 12.4 700 82.3 VGX-236 236.0 196 613 147 BM-9379 BM-9386 4,164 12.4 700 82.2 VGX-288 287.5 238 746 179 BM-9380 BM-9387 4,886 13.9 812 82.0 **A.F.U.E. all based on D.O.E. intermittent pilot/vent damper NG. STANDARD EQUIPMENT Cast iron sections, assembled and tested. Factory assembled with slide-in burner tray with 24 volt combination gas valve and manifold with burner orifi ces. Deluxe insulated metal jacket Integral fl ue collector Automatic vent damper Stainless steel burner tubes Skim tapping for easy cleaning Drain valve Hydrolevel probe LWCO (mounted & wired). Pressure control Gauge glass and fi ttings Pressure gauge ASME safety relief valve Blocked vent shut-off switch Flame roll-out shut-off switch 8

HeatNet Bridge Addressing Worksheet Please fi ll out a separate form for each HeatNet bridge. Every HeatNet bridge comes from the factory with the default address settings (shown in parenthesis) listed in section 2. The bridge can be programmed in the field by following instructions, which can be downloaded, from the product web sites www.hydrothermkn.com and www.rbiwaterheaters.com. This requires some computer and networking experience. The bridges can also be programmed at the factory by filling out the information in section 2 of this worksheet. 1. Customer Information Rep Name: Date Customer Name: Order #: Contact Name 1 : Location/Job: Contact Phone 1 : Contact Email: Factory addressing IS NOT required. 4.4 N2 Factory Addressing IS required (section 2 MUST be completed). 1 Contact is an Engineering contact that will be able to provide technical data for the application. 2. Product: KN Series Futera Series Smith 2.1 Model: (i.e. KN2, KN4, etc) 3. Protocol (Choose one of the following protocols) BACnet MSTP BACnet IP LonWorks N2 4. Addressing Please complete one of the following sections based on required protocol. Default values are shown in parenthesis. 4.1 BACnet MSTP BACnet MAC Address (11): (1-127: Master, 128-254: Passive Member) 2 BACnet Device Instance (11): Baud Rate (38400): choose one 9600 19200 38400 76800 3 4.2 BACnet IP IP Address (192.168.1.24): IP Subnet Mask (255.255.255.0): IP Port (47808): (1-65535) DHCP Client (no): no yes BACnet Network Number (5): (1-65534) BACnet MAC Address (11): BACnet Device Instance (11): 4.3 LonWorks The following parameters are usually set by the commissioning software. Factory programming (of domain, subnet, and node) should only be needed under very special circumstances. Domain: Subnet: Node: 2 Passive members do not respond to BACnet who is messages and thus cannot be automatically discovered. 3 Available on version 2+ BACnet bridges. A HeatNet Master-Member system (network) can contain up to 16 boilers. The HeatNet N2 Bridge is normally attached to the master and can provide most data points that the master periodically reads from each member. Per the N2 specification; baud=9600, data bits=8, stop bits=1, and parity=none. The N2 protocol is limited to 255 data points of each type. For this reason, the HeatNet N2 Bridge is configured to act like 16 different N2 devices. Each device represents a different boiler. The Master/Standalone boiler must always be enabled, but in order to conserve N2 addresses members must be specifically enabled. Please complete the following table: Boiler Enabled Address (1-255) Master/Standalone: (default = 101) Member 2: (default = 102) Member 3: (default = 103) Member 4: (default = 104) Member 5: (default = 105) Member 6: (default = 106) Member 7: (default = 107) Member 8: (default = 108) Member 9: (default = 109) Member 10: (default = 110) Member 11: (default = 111) Member 12: (default = 112) Member 13: (default = 113) Member 14: (default = 114) Member 15: (default = 115) Member 16: (default = 116) Customer PO#: Factory Order #: (internal use only) 9

KN Series Water Boiler Limited Warranty One-Year Warranty The Manufacturer warrants to the original owner at the original installation site that the KN-Series modulating water boiler ( Product ) will be free from defects in material and workmanship for one (1) year from the date of installation or eighteen (18) months from the date of shipment from the factory whichever comes fi rst. If upon examination by the manufacturer the product is shown to have a defect in material or workmanship during the warranty period, the manufacturer will repair or replace, at its option that part of the product, which is shown to be defective. Ten-Year Warranty The manufacturer further warrants to the original owner at the original installation site that the products Heat Exchanger (Cast Iron Block) will be free from defects from condensate corrosion and in material and workmanship for a period of ten (10) years (non prorated) from the date of shipment from the factory. If upon examination by the manufacturer the product is shown to have a defect in material or workmanship during the warranty period, the manufacturer will repair or replace, at its option the Heat Exchanger of the product, which is shown to be defective. Twenty-One Year Thermal Shock Warranty The manufacturer further warrants to the original owner at the original installation site that the products (Cast Iron Sections) will be warranted for twenty-one (21) years against thermal shock when the boiler is installed as a closed loop hot water boiler. This warranty will cover damage due to thermal shock, such as leaks to the cast iron sections from cracks from thermal shock. This warranty does not cover damage due to corrosion, scaling, sooting or to improper installation or operation the inlet and outlet water temperature differential across the boiler cannot exceed 100 degrees F. Water quality is important. As per ASME recommendations, dissolved solids must be less than 200 ppm. Also, ph levels must be in the 6.5-11 range. Failure to follow these guidelines will void the warranty. This Limited Warranty does not Apply: (a) If the product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in anyway by any unauthorized person. (b) To any expenses, including labor or material, incurred during the removal or reinstallation of the product or parts thereof. (c) To products which were not installed and or serviced by a qualifi ed contractor and or serviceman. (d) To burners, jackets, controls and other auxiliary equipment furnished by the manufacturer, but manufacturerd by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) To any workmanship by any installer of the product. This limited Warranty is Conditional Upon: (a) Shipment, to the manufacturer, of that part of the product thought to be defective. Goods may only be returned with prior written approval of the manufacturer. All returns must be freight prepaid. (b) Determination in the reasonable opinion of the manufacturer that there exists a defect in material or workmanship. Repair or replacement of any part under this Limited warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESSED OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES THE OWNER AT THE ORIGINAL INSTALLATION SITE SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS, WHICH MAY VARY BY EACH JURISDICTION. 10

LIFETIME LIMITED WARRANTY Residential Cast Iron Water Boilers First Through Tenth Year The Manufacturer warrants to the original owner at the original installation site that the cast iron sections of the Residential Cast Iron Water Boilers (the Product ) will be free from defects in material or workmanship for ten (10) years from the date of installation. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. Eleventh Year and Above The Manufacturer warrants that the cast iron sections of its residential cast iron water boilers will remain free of defects in material or workmanship under normal usage for the lifetime of the original owner at the original installation site. Should any sections be found to be defective, the Manufacturer will repair or replace, at its option, the original cast iron sections upon the payment of a proportionate charge based on the time the defective section was in service. The proportionate charge will be equal to the appropriate percentage of the trade price of the section at the time the warranty claim is made, determined as follows: Year 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 & Above % of Trade 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 Price This limited warranty does not apply: (a) if the Product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in any way. (b) to any expenses, including labor or material, incurred during removal or reinstallation of the Product or parts thereof. (c) to any other cast iron parts of the boiler. (d) to burners, jackets, controls, and other auxiliary equipment furnished by the Manufacturer, but manufactured by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) to damage as a result of settlement, distortion, collapse, or cracking of any foundation area, beams or pipes surrounding the Product. (f) to any workmanship of any installer of the Product; or to Products installed outside the continental United States or Canada. This limited warranty is conditional upon: (a) shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods can only be returned with prior written approval from the Manufacturer. All returns must be freight prepaid. (b) determination, in the reasonable opinion of the Manufacturer, that there exists a defect in material or workmanship (c) the residential water boiler having been installed in a single family or two family residential dwelling. Repair or replacement of any part under this Limited Warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES THE ORIGINAL OWNER OF THE PRODUCT SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION. 11

LIMITED WARRANTY Residential Cast Iron Steam Boilers One Year Warranty The Manufacturer warrants to the original owner at the original installation site that the Residential Cast Iron Steam Boiler (the Product ) will be free from defects in material or workmanship for one (1) year from date of installation. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. Ten Year Warranty The Manufacturer further warrants to the original owner at the original installation site that the Product s cast iron sections will be free from defects in material or workmanship for ten (10) years from the date of shipment from the factory. If upon examination by the Manufacturer a cast iron section is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. This limited warranty does not apply: (a) if the Product has been subjected to misuse or neglect, has been accidentally or intentionally damaged, has not been installed, maintained or operated in accordance with the furnished written instructions, or has been altered or modifi ed in any way. (b) to any expenses, including labor or material, incurred during removal or reinstallation of the Product or parts thereof. (c) to any other cast iron parts of the boiler. (d) to burners, jackets, controls, and other auxiliary equipment furnished by the Manufacturer, but manufactured by others. Any warranties for such items shall be limited to those warranties offered by the original equipment manufacturer. (e) to damage as a result of settlement, distortion, collapse, or cracking of any foundation area, beams or pipes surrounding the Product. (f) to any workmanship of any installer of the Product; or to Products installed outside the continental United States or Canada. This limited warranty is conditional upon: (a) shipment, to the Manufacturer, of that part of the Product thought to be defective. Goods may only be returned with the prior written approval of the Manufacturer. All returns must be freight prepaid. (b) determination in the reasonable opinion of the Manufacturer that there exists a defect in material or workmanship. Repair or replacement of any part under this Limited Warranty shall not extend the duration of the warranty with respect to such repaired or replaced part beyond the stated warranty period. THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED, AND ALL SUCH OTHER WARRANTIES, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS LIMITED WARRANTY. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE IN ANY WAY FOR ANY CONSEQUENTIAL, SPECIAL, OR INCIDENTAL DAMAGES OF ANY NATURE WHATSOEVER, OR FOR ANY AMOUNTS IN EXCESS OF THE SELLING PRICE OF THE PRODUCT OR ANY PARTS THEREOF FOUND TO BE DEFECTIVE. THIS LIMITED WARRANTY GIVES OWNER OF THE INSTALLATION SITE SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY BY EACH JURISDICTION. 7555 TRANMERE DRIVE MISSISSAUGA, ONTARIO L5S 1L4 CANADA (905) 670-5888 FAX (905) 670-5782 www.knseries.com