WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Similar documents
GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

AFUE 95% Heating Input 50,000 to 200,000 Btuh

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

MERIT SERIES Downflow

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

ELITE SERIES Downflow - High Efficiency Blower Motor

13 GEP A L P - 1 A

Product Data. ama. BW1, BW2 & BW3 Gas-Fired Water Boilers Series B

8+* Bulletin No November 1997

RGE 13 A T - 1 A

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Replacement parts EG/PEG

Peerless Boilers. Series MI. Residential Gas Boilers

G34M Bulletin #69/ August 2003

Product Data BW9 WATER BOILER SERIES B

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

High efficiency, cast-iron gas boiler

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

MERIT SERIES Downflow

Suggested Specifications Prestige Excellence 110

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

SENTRY. High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY

INSTALLATION INSTRUCTIONS PLYMOUTH XTREME GAS-FIRED HOT WATER BOILERS

FSB Series Gas-Fired Hot Water

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

Product Data. ama. Model BW9 Gas-Fired Condensing Water Boiler Series A FEATURES

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

U n i t H e at e r s

83.5 % UP TO 95 % 86.5 % High to Mid-Efficiency Residential & Commercial Heating Solutions. Boilers and Indirect Water Heaters

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

MERIT Series R-410A - Upflow / Horizontal

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

DIVISION FINNED WATER-TUBE WATER HEATERS

Boiler & Water Heater

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G315/6 Cast Iron Boiler

MERIT SERIES Downflow

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

VICTORYII. Cast-iron, power vent gas boiler BOILER FOR OLDER HOMES.

Raypak Residential Products

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

G315/5 Cast Iron Boiler

VICTORYVSPH THE PERFECT CHOICE FOR NEW RESIDENTIAL CONSTRUCTION RELIABILITY AND ECONOMY.

G515/7 Cast Iron Boiler

LGB Gas fired boiler

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

DIVISION FINNED WATER-TUBE BOILERS

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

LGB COMMERCIAL GAS BOILER. Versatile combustion control systems. Made with Weil-McLain quality COMMERCIAL GAS BOILER APPLICATIONS INCLUDE:

RG7D 1-Stage Heat Series

G615/11 Cast Iron Boiler

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

MERIT SERIES Up Flow / Horizontal

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

MERIT Series R-410A - Upflow / Horizontal

DIVISION FINNED WATER-TUBE WATER HEATERS

GB Condensing Gas Boiler

SECTION HEATING BOILERS

MERIT SERIES Upflow / Horizontal

Utica Boilers MAC Submittal

GSR21Q PULSE21 SERIES

INSTALLATION INSTRUCTIONS

Installation, Start-up, and Operating Instructions

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Series 8H. Cast Iron Gas Fired Commercial Water Boiler

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

User s Information Manual

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Gas Valve. Combustion Air Intake. Supply Air Blower AM30. Typical Applications

ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

FINNED WATER-TUBE POOL HEATERS

GB Condensing Gas Boiler

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

PWXL Cast Iron Gas Fired Hot Water Boilers INSTALLATION, OPERATION & MAINTENANCE MANUAL

DIVISION FINNED WATER-TUBE BOILERS

ADF/ADFH 300 and 500

WPSB SERIES II GAS-FIRED HOT WATER BOILERS

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

WPSB SERIES II. Models WPSB-3D WPSB-3DP WPSB-4D WPSB-4DP WPSB-5D WPSB-5DP WPSB-6D WPSB-6DP WPSB-7D WPSB-7DP WPSB-8D WPSB-8DP WPSB-9D WPSB-9DP

MERIT SERIES Up Flow / Horizontal

INSTALLATION INSTRUCTIONS

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

Transcription:

WATER HEATERS / BOILERS -E PRODUCT SPECIFICATIONS Gas-Fired Steam Boiler Bulletin No. 20653 September 202 Supersedes Bulletin No. 20263 AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh MODEL NUMBER IDENTIFICATION Series GSB = Gas-Fired Steam Boiler AFUE 8 = 80% GSB 8-075 E Ignition E = Electronic Ignition Capacity (Input) 075 =75,000 Btuh 2 =2,000 Btuh 50 = 50,000 Btuh 87 = 87,000 Btuh 225 = 225,000 Btuh 262 = 262,000 Btuh 299 = 299,000 Btuh FEATURES CONTENTS Dimensions...5 Features... High Altitude Derate...4 Installation Clearances...5 Model Number Identification... Optional Accessories...4 Specifications...4 NOTE - -E BOILERS ARE NOT AVAILABLE IN CANADA! WARRANTY Cast iron boiler assembly - Limited twelve year warranty in residential applications only. All other covered components - Limited one year warranty in residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details.

FEATURES APPROVALS Low pressure, sectional cast iron boilers are design certified by CSA for use with natural gas or LPG/ Propane. Annual Fuel Utilization Efficiencies are based on US DOE test procedures and FTC labeling regulations. Units are certified by AHRI. Boiler heat exchanger assemblies are constructed and hydrostatically tested in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code Section IV Standards for cast iron heating boilers. APPLICATIONS Gas fired steam boilers are available in seven sizes with heating inputs of 75,000 to 299,000 Btuh. AFUE s of up to 82.7%. Electronic pilot ignition system. Natural gas or LPG/Propane (LPG with optional conversion kit). Boilers may be used in a wide variety of applications including standing cast iron radiators, steam air handlers and convectors. Compact size allows easy installation in a basement or utility room. All units are completely factory assembled with all controls installed and wired. Each unit is factory test operated to insure dependable performance. HEATING SYSTEM Cast Iron Boiler Assembly Boiler sections and push nipples are constructed of long life cast iron. Boiler sections and push nipples expand and contract together, providing positive watertight seal. Boiler components are easily accessible for cleaning and servicing. Electronic Ignition Electronic spark igniter provides positive ignition of pilot burner on each operating cycle. Pilot gas is ignited and burns during each running cycle (intermittent pilot) of the boiler. Main burners and pilot gas are extinguished during the off cycle. Ignition system permits main gas valve to open only when the pilot burner is proven to be lit. Pilot operation is fully automatic on demand for heat. Should a loss of flame occur, the main valve closes, shutting down the unit. Automatic Gas Control Silent operating gas controls provide 00% safety shut off. 24 volt redundant combination gas control valve combines automatic safety pilot, manual shut off option (On-Off), pilot filtration, automatic electric valve (dual) and gas pressure regulation into a compact combination control. Dual valve design provides double assurance of 00% close off of gas to the pilot and main burners on each off cycle. Titanium Burners Titanium composite burners resist corrosion and oxidation. Superior strength and longevity. Used with natural or LPG/Propane gas. Relief Valve Furnished as standard for field installation in top of cabinet. Valve provides for pressure relief of heating system in case of abnormal operating conditions. Valve opens at 5 psig and is approved by ASME. Steam Pressure Gauge Located in top of unit cabinet. Gauge monitors system for safe and reliable operation. Water Level Gauge Furnished on side of unit. Allows a visual inspection for correct cold water level in the boiler. Correct level is stamped on cabinet side behind glass tube. Brass Drain Valve 3/4 in. brass drain valve is furnished for field installation in return piping. OPTIONS LPG/Propane Conversion Kit Conversion kit required for field changeover from natural gas. See Specifications tables. -E / Page 2

FEATURES VENTING Blocked Vent Shutoff Sensor Temperature sensitive fusible-link device prevents unit operation in case of flue blockage. Sensor is furnished as standard and factory installed at the relief opening of the draft diverter. Vent Damper Motorized vent damper electrically interlocks with the gas ignition system to increase efficiency of heating system by reducing loss of heated air up the chimney after burner shut off. Also reduces chimney infiltration during boiler off cycle. Furnished as standard for field installation. CONTROLS Flame Rollout Switch Temperature sensitive fusible-link device is furnished and factory installed on the boiler base just outside of the burner box. Fuse prevents unit operation in the event combustion products passageway through the flueway is reduced or blocked. Steam Pressure Limit Control Factory installed control gives protection against abnormal operating conditions. Adjustable control automatically shuts off gas to the burners if steam pressure reaches cut-off setpoint. Factory installed on side of unit cabinet. Low Water Cut-Off Electronic probe type control automatically shuts off gas to the burners if water level drops below minimum safe levels. Factory installed in boiler. CABINET Constructed of heavy gauge steel with a baked-on enamel paint finish. Cabinet is fully insulated with fiberglass insulation, keeping cabinet surface temperatures low. Controls are shipped factory installed on right side of cabinet and may be field relocated to left side of cabinet. Supply and return steam lines are furnished on both sides of cabinet. Plugs are furnished for unused side. Burner access panel is easily removed for servicing. Integral draft diverter is part of unit cabinet. Transformer/Wiring Junction Box 24 volt control transformer and wiring junction box is furnished on side of unit cabinet for field wiring connections.. OPTIONS Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. -E / Page 3

SPECIFICATIONS Model No. Gas Heating Performance Heating capacity Btuh Net AHRI I=B=R rating - Btuh Net AHRI I=B=R rating - sq. ft. radiation -075E -2E -50E -87E -225E -262E -299E Input Natural gas 75,000 2,500 50,000 87,000 225,000 262,500 299,000 LPG/Propane 70,000 05,000 40,000 75,000 20,000 245,000 280,000 Output Natural gas 62,000 9,000 22,000 53,000 83,000 24,000 245,000 LPG/Propane 58,000 85,000 4,000 43,000 7,000 200,000 229,000 Natural gas 47,000 68,000 92,000 5,000 37,000 6,000 84,000 LPG/Propane 44,000 64,000 86,000 07,000 28,000 50,000 72,000 Natural gas 96 283 383 479 57 67 767 LPG/Propane 83 267 358 446 553 625 77 2 AFUE 82.7% 82.0% 82.0% 82.0% 82.0% 82.0% 82.0% Boiler Data Number of boiler sections 3 4 5 6 7 8 9 Connections in. Boiler capacity - U.S. gallons Electrical characteristics Full 4.2 5.90 7.60 9.30.00 2.70 4.40 Water level 2.6 3.80 5.00 6.20 7.40 8.60 9.80 Flue size diameter (round) 5 6 6 7 7 7 7 Gas piping Natural gas /2 /2 /2 3/4 3/4 3/4 3/4 LPG/Propane /2 /2 /2 3/4 3/4 3/4 3/4 Water supply size Water return size Drain size 2-/2 NPT 2-/2 NPT 3/4 NPT 20 volts - 60 hertz - phase (less than 2 amps) Shipping weight - lbs. package 325 404 483 564 649 79 800 OPTIONAL ACCESSORIES See Lennox Price Book For Complete Listing of Optional Accessories LPG/Propane Conversion Kit Standard Kit 57L60 54L59 54L6 54L63 54L65 54L67 54L69 High Altitude (over 5000 ft.) 57L6 54L60 54L62 54L64 54L66 54L68 54L70 Net AHRI steam ratings indicate the amount of equivalent direct radiation each boiler will produce under normal conditions and thermostatic control. Steam ratings based on an allowance of.333 in accordance with the factors shown on the I=B=R Standard as published by The Hydronics Institute. Selection of boiler size should be based on Net I=B=R Rating being equal to or greater than installed radiation in square feet. 2 Annual Fuel Utilization Efficiency based on US DOE test procedures and FTC labeling regulations. HIGH ALTITUDE DERATE CSA certified units for the U.S. must be derated when installed at an elevation of more than 2000 feet above sea level. If unit is installed at an altitude higher than 2000 feet, the unit must be derated 4% for every 000 feet above sea level. Thus, at an altitude of 4000 feet, the unit would require a derate of 6%. NOTE - This is the only permissible derate for these units. -E / Page 4

DIMENSIONS - INCHES (MM) RELIEF VALVE VENT DAMPER (Furnished) A PRESSURE GAUGE 4-3/4 (2) 26-/2 (673) PRESSURE LIMIT CONTROL SUPPLY OUTLET TRANSFORMER WATER LINE 29 (737) HEAT EXCHANGER BURNERS 2-/4 (3) BLOCKED VENT SENSOR ROLLOUT SWITCH LOW WATER CUT-OFF PROBE 36-3/8 (924) IGNITION CONTROL SIGHT GLASS LOW WATER CUT-OFF GAS VALVE RETURN INLET 24 (60) LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW Model No. A in. mm -75E -/4 286-2E 4-/2 368-50E 7-3/4 45-87E 2 533-225E 24-/4 66-262E 27-/2 699-299E 30-3/4 78 INSTALLATION CLEARANCES - INCHES (MM) Side 6 (52) Gas Supply/Control Side 24 (60) Rear 6 (52) Top 6 (52) Service Clearance (Front) 24 (60) Floor *Combustible Flue Pipe 6 (52) NOTE - Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ ANSI-Z223.). NOTE - Flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI-Z223.) or applicable provisions of local building codes. Clearance for installation on combustible floor if combustible flooring base (field supplied) is installed between the boiler and the combustible floor. See Specifications Tables. -E / Page 5

Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 202 Lennox Industries, Inc.