Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

Similar documents
MVE TS Controller (Touch Screen)

MVE Chart Tech Tips PRODUCT INFORMATION MVE205AF GB

Chart MVE TS Controller (Touch Screen) TECHNICAL MANUAL

Chart Cryogenic Freezers. with MVE TEC3000 Controllers Operating and Maintenance Manual

MVE CRYOGENIC FREEZER with MVE TEC 3000 TECHNICAL MANUAL

MVE TEC 3000 TECHNICAL FREEZER MANUAL

MVE Chart October 2014 Tech Tips

MVE Chart Tech Tips PRODUCT INFORMATION. MVE CryoSystem Series

MVE Variō Series with MVE Variō Pro Controller

CRYOEXTRACE8100 Series Liquid Nitrogen Storage Systems. Operating and Maintenance Manual H01 Rev A

SiteSentinel itouch Console

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Process & TeMPerATUre UniversAl input DigiTAl MeTers

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

The new generation of cold room solutions. CAMAlarm Alarm Alarm

Omniguard 4: Features

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Owner s Manual. Walk-in Monitoring System 100B. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Specification for On-Line UPS Battery Monitoring and Data Management System

ACT2-CS Convenience Store Controller

Ammonia Detection System Codes and Design Specifications

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Model 1062 Environment Monitor

Batt-Safe Battery String Monitoring System

Knight Trak II Instruction Manual

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

SUPREMATouch. Modular Fire & Gas Detection System

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

SUPREMATouch. Modular Fire & Gas Detection System

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

HTC-915-CONT. Heat-Trace Control system

IGD.CO.UK

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Tech Tips (December 2016) Product Information

AS950 REFRIGERATED SAMPLERS

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

TraceNet ECM Series Control System

Accuracy by Design Products for the HVAC Professional

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

THERMAX Efficiency Monitor

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

IntelliPack : 800 Series

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Contamination Control for Electronic and Semiconductor Applications

HOBO U14 Data Logger User Manual

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Setting Up the Dash CapnoFlex LF CO2 Module

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Flexible Air-sampling Smoke Detection

Simple, digital wireless reporting.

DIESEL Engine Fire Pump Controllers Features

Platelet Storage. i.series Horizon Series

Intelligent addressable fire alarm control panel

AS950 PORTABLE SAMPLERS

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Temperature Controllers

PRODUCT LINE. Highest Quality, Best Service

Electronic Flow Switches

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

APC BC300 Series 40kW 208/450/480V User Guide

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

CONVENTION 192 PATIENTS 384 PATIENTS BREAKTHROUGH CONCEPT

Table of Contents SECTION PAGE

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Advanced Test Equipment Rentals ATEC (2832)

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

P1195 DUAL TOURNIQUET MONITOR

This series is utilized for waste streams which are not prone to hardening in the presence of liquid solvent, and provides ease of residue removal.

Series 5000 Hydrazine Analyzer Model 60002

SOP SF SOP for LN2 Freezers

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Mark 25 Ultrapure Water Conductivity Analyzer

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

Design Benefits and Advantages:

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

UDC 700 Universal Digital Controllers and Indicator Specifications

Transcription:

employs a variety of advanced features that enable the controller to monitor and control the environment inside a freezer with a high level of precision. Liquid Nitrogen Level Measurement uses a differential pressure system to determine the LN2 level to an accuracy of ± 0.5 in. (15 mm) and a resolution of 0.1 in. (5.0 mm). Unlike alternative level sensing systems, differential pressure allows the exact level to be measured and displayed. Using the simple single point calibration in a range of 3.0 in. to 48.0 in. (75 mm to 1220 mm), the patented, selfmaintaining, closed-loop system displays in inches, millimeters, or a percentage full. Automatic Liquid Nitrogen Level Control The fully automated LN2 level control system is based on userdefined parameters that can be electronically adjusted over the entire level range. The parameters include Low Level Alarm, Low Level Fill Point, High Level Fill Point and High Level Alarm. The redundant Dual Solenoid Valves for overfill protection run on 24 VDC, 1.0 amp (max). Liquid Usage This exclusive feature provides an estimation of liquid usage to track LN2 consumption and can provide an early failure warning to allow sufficient time to implement corrective action and save irreplaceable samples. User-Defined Alarms A total of 1 audio/visual alarms are used to alert the user to any potential or developing problems. The alarms include: High Temperatures, Low Temperatures, High Level, Low Level, Liquid Usage, Maximum Fill Time, Gas Bypass, Temperature Calibrations, Low Battery, Power Failure, Lid Open and Communication Loss. Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay Temperature Measurement Two independent temperature measurement channels are employed to accurately measure the temperature across the entire storage space. The two platinum RTD sensors have an accuracy of ± 1.0 C and a resolution of 0.1 C. The temperature can be displayed in C, F or K. The single or two point calibration also has altitude compensation for the highest accuracy. Hot Gas Bypass This unique feature is able to vent warm nitrogen gas from the supply line before initiating a fill. This prevents warm gas from entering the freezer space, which helps maintain a stable temperature gradient and increases the efficiency by reducing excess LN2 evaporation. Event Log / Data Storage tore vital, unalterable, time-stamped data in nonvolatile memory. This is a great tool for assessing freezer performance and troubleshooting any problems. The memory can store 30,000 events, an estimated 10 years of storage capacity. The data includes time-stamped temperatures, LN2 level, liquid usage, and any alarms or events. Password Security The multilevel security system comprised of up to ten userspecific programmable passwords and four security levels can be customized to grant or restrict personnel access to certain menus and settings. Communication Capabilities independent port can be used to communicate with other TEC 3000 controllers, a remote PC, serial printer, or other RS- 485 networks and devices. Options include ASCII, MODBUS, Printer and One Fill All Fill (OFAF). Capabilities independent port can be used

Temperature Two independent temperature measurement channels are employed to accurately measure the temperature across the entire storage space. Hot Gas Bypass This unique feature ent nitrogen gas from the supply line before initiating a fill. can be

Automatic Liquid Nitrogen Level Control The fully automated LN2 level control system is based on user-defined parameters that can be electronically adjusted over the entire level range. The parameters include Low Level Alarm, Low Level Fill Point, High Level Fill Point and High Level Alarm. Communication Capabilities independent port can be used to communicate with other TEC 3000 controllers, a remote PC, serial printer, or other RS485 networks and devices. Options include ASCII, MODBUS, Printer and One Fill All Fill (OFAF). Capabilities independent port can be used

Password Security The multilevel security system comprised of up to ten userspecific programmable passwords and four security levels can be customized to grant or restrict personnel access to certain menus and settings. Event Log / Data Storage tore vital, unalterable, time-stamped data in nonvolatile memory. The data includes time stamped temperatures, LN2 level, liquid usage, and any alarms or events.

Chart: Total Cryogenic Solutions Air Separation Distribution & Storage Bulk Storage Tanks Dewars Liquid Cylinders Security Through Systems Freezers Chart BioMedical 2200 Airport Industrial Dr., Ste. 500 Ball Ground, GA 30107 Ph 770-721-7759 Toll Free 1-800-482-2473 Fax 770-721-7758 customerservice.usa@chartindustries.com Chart Inc. reserves the right to discontinue its products, or change the prices, materials, equipment, quality, descriptions, specifications and/or processes to its products at any time without prior notice and with no further obligation or consequence. All rights not expressly stated herein are reserved by us, as applicable. Chart BioMedical Ltd. Ph +44(0) 1344 403100 Fax +44(0) 1344 429224 customerservice.europe@chartindustries.com Chart Japan Co., Ltd. Ph + (03) 5776 2670 Fax + (03) 5776 2676 customerservice.japan@chartindustries.com Chart Australia Pty Ltd. Ph + 61 2 974 94 333 Fax +61 2 974 94 666 customerservice.australia@chartindustries.com Copyright 2017 Chart Industries PN ML-CRYO0043 A