WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Similar documents
System and Components Installation Manual

Carbon Monoxide Room Alarm Installation and User Guide Part No:

CARBON MONOXIDE DETECTOR, i4h-co-m330

Installation and User Guide

ADT Carbon Monoxide Alarm

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

C8600A CO Alarm OWNER S GUIDE RESIDENTIAL USE ONLY

Red Alarm Indicator Light

169MHz Telecare Devices Carbon Monoxide Detector

169MHz Telecare Devices Gas & Carbon Monoxide Detector

COMPUTHERM. CO1400 Carbon Monoxide Alarm OPERATING INSTRUCTIONS

Protecting Children from Carbon Monoxide Poisoning

3 Macurco Carbon Monoxide Detector CM-16A

CO-9X User Manual 6 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

7 YEAR LIFE CARBON MONOXIDE POISONOUS GAS ALARM

CO-808S User Manual. Carbon Monoxide Poisonous Gas Alarm With Sealed 6 Year Power Pack

Carbon Monoxide Alarm User s Manual

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL Models RV & RV ABOUT THIS ALARM

Manhattan Fire Protection District

! WARNING: RECREATIONAL VEHICLE (RV) Carbon Monoxide Alarm USER S MANUAL 65 Series Surface Mount Models: , R, MS, R-MS

OWNER S MANUAL for Models:

Carbon Monoxide Safety Information

Total Connect Box. User manual

Seriously how do you know your CO monitor is Working!

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM

Macurco CM-E1 Carbon Monoxide Detector

EWF1 EWF1CO WIRELESS SMOKE DETECTOR WIRELESS SMOKE & CO DETECTOR

Carbon Monoxide Detectors. What is carbon monoxide?

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Models & ABOUT THIS ALARM

GS100M Gas Detection Controller

GL-CO-RFG Channel Gas Leak Alarm System

Carbon Monoxide Safety

HOME FIRE SAFETY. Reference Guide

Frequently Asked Carbon Monoxide Questions

Model No: Little Devil II (inc ss)

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

LL6070 Carbon Monoxide Monitor

LOMBARD FIRE DEPARTMENT ILLINOIS CARBON MONOXIDE ALARM DETECTOR LAW. Carbon Monoxide Law. Takes effect January 1, 2007 One outside each sleeping area

can quickly rise to dangerous levels

C0-210 Carbon Monoxide Probe

Carbon monoxide Knowing more

about your house Carbon Monoxide

Carbon Monoxide Alarm Owner s Manual

Carbon Monoxide Detector

2.1 CO is a colorless, odorless, tasteless, non-irritating, toxic gas.

From Your Building Inspector

This About Your House answers often-asked questions about carbon monoxide to help you make the right decision to make your home safe.

Travis County Emergency Services District #1 Standard Operating Guidelines

Safety Alert New Gas Regulation 2013

Ontario is taking another step to keep families and homes in Ontario safe by making carbon monoxide alarms mandatory in all residential homes.

BX444-Mc Gas Detector

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

OWNER'S MANUAL PLEASE READ AND SAVE!

PROTECT YOURSELF AND YOUR FAMILY FROM THE SILENT KILLER IS YOURS INSTALLED?

Macurco HD-11 Hydrogen Gas Detector

Carbon Monoxide Alarm with Safety Shut-Off

Frequently Asked Questions About Carbon Monoxide Detectors

OPEARATING GUIDELINES FOR AERO-252 (Pages 1 to 3 contain general information on CO Guardian. Pages 4 to 6 contain information specific to Aero 252)

What is carbon monoxide (CO) and why do I need a carbon monoxide detector?

Gas appliances. Keeping them safe

TESTED TO UL2034, UL1484 AND CSA 6.19

SAFETY TIPS. From Your Building Inspector. The Sound of Safety.

Suburban Propane Notice of Public Awareness. Additional Information for Customer s Buried Piping

PROTECTING AGAINST CARBON MONOXIDE. Questions and Answers about Carbon Monoxide (CO) and CO Alarms

WIRELESS CARBON MONOXIDE ALARM

CARBON MONOXIDE (CO)

Agenda. Intro Objective What is Carbon Monoxide Carbon Monoxide Law History Nelsons Law NFPA 720

DIGITAL 7 YEAR LIFE CARBON MONOXIDE ALARM (Includes all colour variants)

RV Carbon Monoxide Alarm

! WARNING! User Manual LogiCO2 -Scout. Important Safety Information! CO2 Concentration Levels (%) and Effects ENGLISH

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Carbon Monoxide (CO) Detection PRODUCTS. Accessories Conventional Detectors

Model Carbon Monoxide (CO) Alarm Response Policy

U S E R M A N U A L UBH1RF HEAT ALARM

4.2kW GAS CABINET HEATER OPERATING INSTRUCTIONS. For Model: TWGC100

RV Safety Alarms Education Test

BATTERY POWERED CARBON MONOXIDE ALARM WITH DIGITAL DISPLAY. Model Ei206D

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Response to Carbon Monoxide Incidents. W.J. Streett Jr Training Section Chief

GS100M Gas Detector. Technical Specification

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

CA6150 Carbon Monoxide Alarm

Home CALOR. At with INTRODUCING OUR NEW TUMBLE DRYER SAFETY AT HOME

Marine Carbon Monoxide Alarm

Carbon monoxide household alarm. DURAN ELECTRONICA. Tomás Bretón 50, Madrid, Spain

PROPANE GAS HEATER MODEL NO: GRH35 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC01/14

Digiplex LED Keypads User s Manual

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Protect Safety Alarms

Commercial Carbon Monoxide Detector Owner s Manual

CARBON MONOXIDE DETECTOR WITH BUILT IN WIRELESS TRANSMITTER. Installation and Operation Manual. Document # Model # CO5-MC(US) 418 MHZ TRANSMITTER

USER MANUAL CEF AP28 CONTROL PANEL

B15583/R0/204EN&205EN/U&C 7/12/05 3:20 PM Page 1 BATTERY POWERED CARBON MONOXIDE ALARM. Model Ei 204EN Model Ei 205EN Model Ei 205ENA.

OWNER S MANUAL for Models:

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

U.S. Consumer Product Safety Commission Washington, DC 20207

Transcription:

Wireless Gas Detection & Shut Off System - User Manual & Instructions Please read and follow these instructions prior to installation of the system as correct installation is critical to the performance of the system. The system has been designed for Residential premises to detect harmful levels of combustible and / or toxic gases and provide visual and audible alarms when preset levels are reached. When fitted the system will also activate a shut off device to close the gas WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL supply and prevent further build up. The installation of this system (or any detector) is no substitute for the proper installation and maintenance of fuel burning appliances by a competent person in line with the manufacturers or industry guidelines. Effects of Carbon Monoxide (CO) Carbon Monoxide is a highly toxic gas which is produced when fuels are burnt - it has no odour or colour or taste to detect its presence. Exposure to high levels of carbon monoxide can cause many symptoms and result in death. Symptoms can range from headache, nausea, vomiting and drowsiness through to unconsciousness, convulsions, cardio-respiratory failure and death. System Overview Flowtech Controls Ltd 2009 The system comprises a Detector (or Detectors), a Control Panel and a Shut Off device (either a Valve or an Actuator). The system has been designed to detect potentially harmful gas levels and provide visual and audible alarms and communicate the alarm to a Control Panel which in turn will close off the gas supply to prevent further increases in harmful gas levels (if the shut off device is fitted). The system can manage up to 3 detectors and guidance on location of different types of Detectors can be found below. Detectors can be used independent of the other devices and will provide visual and audible alarm only.

INSTALLATION GUIDE 1.2 Natural Gas Detector(s) FLOWTECH RECOMMENDS THAT ALL WIRING SHOULD BE UNDERTAKEN IN ACCORDANCE WITH THE LATEST WIRING REGULATIONS OF THE INSTITUTE OF ELECTRICAL ENGINEERS It is recommended that a Natural Gas Detector is located approximately 30 cm below the ceiling and at least 1.5m above the floor and within 4-5 m of a gas burning appliance. Do not install or position the detector... 1. Detector Location and fixing: 1.1 Carbon Monoxide Detector(s) It is recommended that a CO Detector is located in every room in which a fuel burning appliance is used. Due to the properties of Carbon Monoxide the detector should be positioned approximately outside the premises in damp, humid or dusty areas above a gas cooker, gas boiler or fuel burning appliance in a drafty area e.g. close to a window or a doorway where it can easily damaged 30 cm below the ceiling and at least 1.5m above the floor and a minimum of 1.5m away from any 1.3 Fixing Detector(s) fuel burning appliance. If one CO Detector is being fitted in the premises it is advisable to position the detector close to sleeping areas where it can he heard. When you have chosen a location for your detector(s) ensure that the detector can be connected to the required power supply. Do not connect it yet. or fix to the Do not install or position the detector... wall.. Wireless communications links need to be checked during installation to outside the premises in damp, humid or dusty areas above a gas cooker, gas boiler or fuel burning appliance in a drafty area e.g. close to a window or a doorway behind furniture, curtains, blinds ensure that the system operates fully. 2. Control Panel location and fitting in an area where the detector may be exposed to insecticide, air cleaners, glue, hair spay, The Control Panel receives Wireless signals from or high levels of tobacco smoke Please do not install the detector if the room is being decorated or contains new furniture. If it has already been installed, please power off the detector and use a plastic bag to cover the detector to the Detector(s) and provides power to the Shut Off Device(s). protect it. Don t remove the plastic bag until the room is ventilated fully, then power on the detector. Location of the Control Panel will be such that the chosen Shut Off Device can be connected with the lead from the Control Panel and the Control Panel can be connected to the power supply. This may The warranty does not cover damage resulting from the above situations. vary depending on the Shut Off Device selected. If the Valve option is chosen installation MUST be made by a qualified Gas Installation Engineer.

When you have chosen a location for your Control Panel ensure that the Control Panel can be 4. Installation Check connected to the required power supply. Do not power on yet or fix to the wall. Wireless communications links need to be checked during installation to ensure that the system operates fully. When the Actuator or Valve has been fitted and connected to the Control Panel, power on the Control Panel and the Detectors to run an Installation Check, This sequence will check that the Detectors can 3. Actuator fitting and connections conduct wireless communication with the Control Panel; that the Control Panel can supply signals and power to the Shut Off Device; and that all Reset Functions are working correctly. We advise that this The Actuator which closes the gas supply in the event of an alarm is designed to be fitted to the Gas check is conducted prior to fixing the Detectors and Control Panel in place. Meter Control Valve located next to the Gas Meter. The Actuator is supplied with 2 sets of metal fixing brackets which secure the Actuator to the Gas Meter Control Valve. Select the brackets which match the Gas Meter Control Valve and secure the Actuator to the Gas Meter Control Valve. 4.1 When power is supplied to the Control Panel the POWER light will be lit GREEN. The Actuator has a Metal Control Arm which is secured around the Lever of the valve by 2 screws (provided). During installation ensure that the Actuator is secure and that the Manual Reset button is accessible. Tighten the 2 screws which secure the Arm to the Valve Lever. Connect the power supply lead from the Actuator to the Control Panel. 4.2 When power is supplied to the CO (Carbon Monoxide) Detector(s) the GREEN LED POWER light will be lit. 4.3 When power is supplied to the Gas Detector(s) the GREEN LED POWER light will start to flash. This indicates the warm up period. It will stop flashing after approximately 3~5 minutes. This is required for Metal Fixing Bracket Manual Reset Button Metal Control Arm the sensor in the detector to stabilise and will occur whenever power is re-connected.

Valve option has been used in your system, re-open the Gas Supply be pulling down the Manual Reset Button see 3 above. 4.9 4.4 The Control Panel is designed so that Detectors have to be paired with it by receiving an unique Code. When all Detectors have stabilised shown by the GREEN POWER Light being on constantly ON this coding can take place. The system is designed to stop attempts to re-open the Shut Off Device during an alarm. Whilst the Alarm is still running attempts to close the Actuator (by pulling down on the Reset Button) will be prevented and the device will close again. If a Re-set cannot be made the override system is working correctly. 4.5 On the top of the Control Panel is a button. Press this button for 1 SECOND. The RED TO CODE light will come on and the light will stay on for 30 SECONDS. During this 30 second period an unique 4.9 Ensure that the gas supply is open as your system check is now completed. Fix the Detector(s) and the the Control Panel in place using the fixings provided. code will be sent to all detectors within range so that they can pair and be able to send signals to the Control Panel. 5. Post Installation Checks It is recommended that you check your Detectors are functioning correctly every 3 months by pressing 4.6 To PAIR each Detector with your Control Panel PRESS the TEST button on each detector for 2 the TEST button. Ensure that the Detectors are not damaged and remove any dust which may accumulate to ensure they can operate effectively. If the FAULT Light is lit contact your supplier. SECONDS DURING THIS 30 SECOND PERIOD WHILE THE RED TO CODE LIGHT ON THE CONTOL PANEL IS ON. If the Detector has been successfully paired and is within range the Control Panel will make 3 BEEP SOUNDS. Repeat until all detectors in your system have been checked. The Detectors should be replaced every 5 years. IMPORTANT This system has been designed to provide Visual and Audible Alarms in the event of dangerous Additional Detectors can be added to your system at any time. To do this repeat steps 4.4, 4.5 and 4.6 gas levels being reached and close off the gas supply to prevent further build up of these gases. It is vital that you protect yourself and other occupants by taking the following steps:- 4.7 To clear all pairings press button on top of the Control Panel constantly for approximately 40 seconds. The RED TO CODE LIGHT will be lit and then GO OFF. 4.8 To test that the Control Panel can open and close the gas supply PRESS the TEST button on the Control Panel and your shut off device will close. If your system uses the Actuator as the shut off device the gas supply can be re-opened by pressing the RESET button on the Control Panel. If the Get fresh air into the premises by opening doors and windows Call a qualified technician and have the problem fixed before restarting appliances. If anyone is experiencing symptoms of carbon monoxide poisoning: headaches, dizziness, vomiting, call for Medical help and immediately move to a location that has fresh air. Ensure all occupants are accounted for Do not re-enter the premises until it has been aired out and the problem corrected.

5.1 Maintenance To ensure the continued operation of your system we recommend the following steps be taken:- (a) Ensure that the holes and vents on the gas detectors and Alarm Panel are free from dust or Static Current Alarm Current Static consumption Alarm Consumption <50 MA <150 MA < 1 W < 3 W cobwebs. If they require cleaning disconnect the power and lightly brush the holes and vents with a soft brush Alarm Volume 85 db Wireless Range 200m (Open Ground) (b) Never use chemicals to clean the detectors or Alarm panel (c ) Never allow water to enter the detectors of Alarm panel 5.2 Fault Lights In the unlikely event of a Gas Detector showing a YELLOW Fault Light will light up and the detector will Humidity Alarm Density Response Time 0-60 C <97% RH Natural Gas 1000-5000PPM LPG 1000-10000PPM <30 seconds sound. If this occurs, disconnect power to the detector, clean as above at 5.1 and re-connect the The response time of this alarm conforms with EN50194 power supply. Repeat if necessary. If this does not rectify the fault please contact your supplier for further assistance. 6.3 Gas Lever Control 6. Technical Information 6.1 Carbon Monoxide Detector -10 - +50 C Power Supply 230v AC Humidity <95% Static Current <140 µa Rated Voltage DC 12 v Operating Voltage DC 6v 18v Alarm Current 60 MA Rated Current 100 ma Operating Current 20mA 1000mA Alarm Volume 85 db Rated Power 1.2 W Operating Power 0.24 W 10W 0-50 C Valve Closing time 5-10 seconds Humidity 25%-85% Wireless Range 200m (Open Ground) Valve Opening time 5-10 seconds The response time of this alarm conforms with EN50291 CO Level PPM 50 PPM 100 PPM 300 PPM 400 PPM Response Time 60-90 mins 10-40 mins < 3 mins Immediately Torque Insulation resistance Gross Weight Dimensions 30-60 kg.cm >20MΩ 395g 100mm x 90mm x 70mm 6.2 Gas Detector Natural Gas / LPG Power Supply 230v AC Flowtech Controls Ltd 2009 Warm Up Current <60 MA