CHEMICAL FUME HOOD PROGRAM

Similar documents
Fume Hood Safety TYPES OF FUME HOODS

Biosafety Cabinets and Fume Hoods Supplemental Material (OHS_BIO304)

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Laboratory Fume Cupboards

Section 1.0: LAB VENTILATION TABLE OF CONTENTS. C. General Ventilation Considerations 3. D. Pressurization 7. E. Supply Air Arrangements 8

Appendix A.4.1. Safe Fume Hood User Guide

Biological Safety Cabinets or Fume Hoods Which one to use?

SECTION LABORATORY EQUIPMENT CONSTRUCTION STANDARD PART 1: GENERAL Scope of Standard

Florida International University. Biosafety Cabinet Program

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Safe Operating Procedure (Revised 2/10)

LABORATORY EQUIPMENT. A. Section Accessibility for People with Disabilities. B. Section Plumbing Basic Materials and Methods

VP, Facilities and Construction Management

THE IMPACT OF FACILITY HVAC SYSTEMS ON BIOLOGICAL SAFETY CABINETS

Biological Safety Cabinets. Biological Safety Cabinets

SECTION SPECIAL EXHAUST SYSTEMS. A. Laboratory Ventilation and Hazardous Exhaust Systems. 3. Chemical Fume Hoods and Storage Cabinets

UC DAVIS Campus Design Guide DIVISION 11 - EQUIPMENT

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

MD and Its Impact on Lab Facilities

Lab Design shall comply with the UC Lab Safety Design Manual located at: LABORATORY FUME HOODS

This document provides general instructions on the use of chemical fume hoods to protect lab personnel against exposure to hazardous materials.

UC DAVIS Campus Standards & Design Guide DIVISION 11 - EQUIPMENT

How To Select The Right Laboratory Hood System

Technical Catalog laboratory furniture system

Division 11 - Equipment

Environmental Health and Safety Biological Safety Program Guidance Document

Precision Containment for All Applications

LABORATORIES, CHEMICAL AND BIOLOGICAL

Section 5.0: HAZARDOUS MATEIRAL STORAGE TABLE OF CONTENTS. A. Regulations, Standards and References 2. B. Scope 3. C. Approvals and Listings 3

Animal Tissue Culture SQG 3242 Equipment and Lab design. Dr. SITI PAULIENA MOHD BOHARI

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Technical Catalog laboratory furniture system

AirGard. Air Flow Monitors

Laboratories and Hazardous Materials. Company Overview

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

Rutgers Environmental Health and Safety (REHS)

LABORATORY CHEMICAL HYGIENE AND SAFETY PLAN

Laboratory Control and Safety Solutions Application Guide

LABORATORY DESIGN HANDBOOK

Control of Biological Hazards

FUME CUPBOARDS DESIGN FEATURES GENERAL ARRANGEMENT FACE VELOCITIES EXTRACTION SYSTEMS AIRFLOW CHARACTERISTICS

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

University of California, Davis Laboratory Self-Inspection Checklist

CLEAN AIR SYSTEM.

Technical Catalogue laboratory furniture system

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

PDH & Professional Training

XPert Balance and Bulk Powder Enclosures

Clean Air Device. Yale University. Office of Environmental Health & Safety. Primary Containment Device

Application: Response procedures for major and minor spills, including: organic solvents acids bases dry chemicals mercury hydrofluoric acid

PHYSICAL FACILITIES Consultant s Handbook Division 01 General Special Requirements for Laboratories. Page 1 of 6

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

L a b o r a t o r y E q u i p m e n t C a t a l o g

University of Houston Campus Design Guidelines and Standards Construction Systems and Assemblies: Section 12.0 A.01 Laboratory Design Guide

Minor Change Office of Radiological Safety Number: Revision 00 By: Georgia Institute of Technology. Approved 04/21/2016 Date: / / Page 1 of 6

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

Ventilation System Description. September 8, 2000 HETA

BIOLOGICAL SAFETY CABINET

Innovation in air purification unmatched air quality

IBC Position on Bunsen Burner Use in Biosafety Cabinets

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

MCB SERIES. cross ventilation cartridge dust collector

Appendix C IBC Safe Use of Biosafety Cabinets SOP

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

4. The Whitman College Chemical Hygiene Officer is Fred Miller, Manager, Environmental Health and Safety.

A. General Safety LAB/ROOM: INSPECTED BY: DATE:

Technical Catalogue laboratory furniture system

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Glossary of Terms Laboratory & Fume Exhaust Fans

Hazardous Materials Protection and Contingency Plan for Carnegie Mellon University Doha Campus

SEMICONDUCTOR FABRICATION FACILITIES

FIRE PROTECTION PROGRAM

Sample Safety Inspection Checklist for Schools

General Industry Safety and Health Checklist Guidelines. Building and Premises. Loss Control Bulletin

CNS Cleanroom Safety Orientation Form

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

B. Design meeting requirements of the particular class and type of cabinet as follows:

Safe Use of a Class II Biological Safety Cabinet

Ventilation for New Low-Rise Residential Buildings July 20, 2015

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

MIT Emergency Response Guide

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Advancing Laboratory Ventilation Technology

Laboratory Safety Audit

6/19/2015 BIOLOGICAL SAFETY CABINET. Types of Classes. Types of BSC.

Dangerous Waste Generator Training. How do I properly manage wastes generated in my work area?

NATIONAL INSTITUTES of HEALTH FUME HOOD TESTING PROTOCOL. For CONSTANT VOLUME FUME HOODS

NFPA 45 NFPA 211 NFPA 1600

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:


Direct Fired Heater Model AD Specification

Selected Laboratory Energy Efficiency Measures

Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

PART III. Laboratory equipment

EMERGENCY RESPONSE GUIDE IMMEDIATE EMERGENCY PROCEDURES

COMBUSTIBLE DUST SAFETY PROGRAM

City of Grover Beach Building Division Fire & Life Safety Requirements CANNABIS CULTIVATION, MANUFACTURING AND LABORATORY FACILITIES

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Transcription:

Reed College 3203 Southeast Woodstock Blvd. Portland Oregon 97202-8199 CHEMICAL FUME HOOD PROGRAM Last Reviewed: 3/20/17 I. PURPOSE... 1 II. SCOPE... 1 III. REFERENCES... 2 IV. PROGRAM RESPONSIBILITIES... 2 A. Environmental Health and Safety:... 2 B. Facilities Services... 2 C. Employee/Fume Hood User... 2 V. LABORATORY VENTILATION... 4 A. Chemical Fume Hood Types... 4 B. Specialty Exhaust Systems... 4 I. PURPOSE To minimize exposure to airborne contaminants created by laboratory research activities. To ensure the laboratory fume hoods are operating in accordance with College requirements. To establish design criteria consistent with professionally recognized consensus standards and practices to provide the best level of protection and performance for new laboratory fume hoods installed at Reed College. II. SCOPE Laboratory fume hoods provide the primary control measure available in the laboratory to minimize exposure to toxic gases, vapors, mists, or fumes generated by the manipulation of chemicals during research activities. EHS measures fume hood face velocity annually to confirm proper operation, and notifies Facilities Maintenance of fume hoods with poor velocity for repair. Page 1 of 5

The laboratory researchers, EHS, and Facilities must work together to ensure fume hoods operate and are used properly to provide adequate protection to the end user. III. REFERENCES Page 2 of 5 ANSI/ASHRAE 110, Method of Testing Performance of Laboratory Fume Hoods ANSI Z9.5 Laboratory Ventilation IV. PROGRAM RESPONSIBILITIES A. ENVIRONMENTAL HEALTH AND SAFETY: Responsible for the establishment, implementation, and maintenance of a written fume hood program. The EH&S office shall: facilitate and coordinate testing of fume hoods; report deficiencies found during the EH&S-facilitated survey and produce repair requests; develop and provide training for the fume hood users; review fume hood commissioning reports. The program shall be updated as necessary to reflect changes in workplace conditions that affect fume hood use. B. FACILITIES SERVICES Repair reported deficiencies or contract outside service, if needed. Notify the department administrator and/or lab users when repairs are planned for fume hoods. Do not remove contents from inside the laboratory fume hood. If repairs are required inside the laboratory fume hood, have user remove its contents to provide access inside the hood. C. EMPLOYEE/FUME HOOD USER Use the fume hood with the sash as low as possible, at or below the indicated operating height. The fume hood is more effectively at the sash operating height and provides a physical barrier between you and the fume hood contents. Do not store chemicals or equipment that are not in use within the fume hood, and do not place these items at the front edge of the hood or at the rear baffles (openings) of the hood. These practices can cause turbulence and a loss of containment within the hood. If you must use large equipment to support your research activities within a hood, raise the equipment on blocks at least 2" above the work surface to ensure a more uniform flow into the hood and to minimize turbulence produced by this equipment. Work at least 4" in from the hood sash opening, and keep the sash glass clean and free from visible obstructions.

Page 3 of 5 Avoid sudden movements at the face of the hood. Walking briskly past the hood can disrupt air currents or create turbulence, pulling vapors out of the hood. Do not use perchloric or hydrofluoric acid inside a fume hood unless the hood was specifically designed for its use. Due to the physical properties of these materials, special fume hoods are required for work with these materials. If the hood is equipped with a flow indicating device (i.e., magnehelic gage, audible/visual alarm), confirm the hood operates properly before use. Immediately report fume hood malfunctions to Facilities Maintenance for repair. Obey all signs and notices posted on the hood by the Facilities Maintenance staff that is repairing hoods.

V. LABORATORY VENTILATION A. CHEMICAL FUME HOOD TYPES Conventional Fume Hood or constant air volume hood. Equipped with an internal baffle to the exhaust opening. Face velocity is inversely proportional to sash height. Bypass Hood is designed so a fraction of air entering the hood face may pass over the top and bottom of the hood sash. This allows the air velocity near the work surface to stay relatively constant. This protects susceptible experiments and equipment from excessive air speeds which could have detrimental effects. It also allows for less static pressure and frictional resistance to air flow than would a conventional hood. This ensures a constant air volume as the hood sash height is changed. Auxiliary Hood is a bypass hood with a direct auxiliary air connection that has not been cooled in the summer or completely heated in the winter. This is an attempt to reduce heating and cooling costs for the institution. Its disadvantage is that it increases maintenance costs due to the requirement of more ductwork, fans and air tempering facilities. Self-Contained Hoods pull room air over the work surface and through a filter suitable for the work intended in the hood. This prevents the fan from being contaminated because the air has already has been filtered. Such hoods are desirable in areas where ductwork is not available. Filters usually need to be replaced every 1 to 2 years. Walk-in Hoods rest directly on the floor or on a pad on the floor. They are designed to fit around an apparatus which will not fit in a standard hood. Explosion-proof Hoods have explosion-proof electrical devices. The hood will not contain an explosion but the electrical equipment will not provide a source of ignition. Perchloric Acid Hoods are designed for use with perchloric acid and must be equipped with a water wash system for the hood and ductwork. Radioisotope Hoods are designed for use with radioactive chemicals and constructed from stainless steel without seams or edges. Variable Air Volume (VAV) Hood maintain a constant face velocity regardless of sash position. The system continuously measures the amount of air exhausted to maintain a constant face velocity. A VAV system increases the ability of the hood to protect the worker from the possibility of exposure to chemical fumes. B. SPECIALTY EXHAUST SYSTEMS Page 4 of 5

Biological Safety Cabinet is not a laboratory hood and considered to be a special safety enclosure used to handle and contain pathogenic microorganisms. The cabinet is designed to protect the product and also provides limited protection for lab personnel by utilizing an inward airflow away from the employee. Biological Safety Cabinets must be National Sanitation Foundation (NSF Standard 49) certified for Class II, Type A2 Biological Safety Cabinets and bear the NSF seal. Laminar Flow Cabinets are not considered laboratory hoods and do not provide any protection for lab personnel and are intended to provide a clean airflow for the product protection. It is typically a ventilated, partially enclosed cabinet with airflow over the work surface. Canopy Hoods have an enclosed horizontal duct suspended above a work area that is too large to be contained in a conventional hood. The disadvantage of the hood is it draws contaminants past the workers breathing zone. Glove box is used when toxicity, radioactivity or reactivity is too great a hazard for work in a conventional hood. The greatest advantage of the glove box is worker protection Page 5 of 5