Kinsa Smart Ear ThermometerTM Instructions For Use

Similar documents
Non-Touch Thermometer. User Manual. ARC Devices Ltd.

User Manual. Non-contact Infrared Thermometer.

Forehead Infrared Thermometer

NON-TOUCH THERMOMETER User Manual

CLETEF-786. Infrared Thermometer Instruction Manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Instructions. Consumer Info-Line

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

CareTemp Touch Free Thermometer. Directions for use

Forehead Thermometer Instruction Manual

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

No Touch Thermometer

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

Adtemp TM II 412 Digital Fever Thermometer USE, CARE & MAINTENANCE

By cmlam at 2:33 pm, Dec 12, 2017

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

I/R Thermometer Gun 12:1

MyKi Care Thermometer (MCT 1.0) USER MANUAL

62 MAX/62 MAX + Infrared Thermometer

Adtemp TM ULTRA 417 Digital Fever Thermometer USE, CARE & MAINTENANCE

Dual-Mode Infrared Thermometer Instruction Manual

100 Ft. LASER DISTANCE METER

Precision Infrared Thermometer. Users Manual

programmable control model installation and setup guide M /11/ Hunter Fan Company

MT4 MAX/MT4 MAX + Infrared Thermometer

Health & Safety Kit. Digital Bath and Room Thermometer FlexiSafe Fever Alarm Thermometer Nasal Decongester

64 Max IR Thermometer

62 MAX/62 MAX + Infrared Thermometer

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Users Manual. Air Velocity Meter

TempSmart TS-100. Temp & Humidity Data Logger. User Guide

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

InTemp CX Temperature Logger (CX40x) Manual

Digital Heat Block User Manual

MicrOTDR. Optical Fault Locator. User Manual

PERSONAL Ultrasonic Cool Mist Humidifier

Polar H7 Heart Rate Sensor. User Manual

Digital Cooking Thermometer models / 00282

1.5 GALLON ULTRASONIC HUMIDIFIER MODEL # EE-5303W

Thermometer with Probe model 00891A

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

Enteral Pump Instructions for Use To Assemble When the low

THERMOFOCUS 0800H5 Professional

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

Dry Bath Heating Systems

Infrared Thermometer

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

User's Guide. Pinless Moisture Meter. Model MO257

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Dual Laser InfraRed (IR) Thermometer

Users Manual. Visit us at

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

3R, 3G 5R, 5G Point Laser Levels

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

MD-MINI Dry Bath. Instruction Manual

Weber igrill App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Disconnecting 7 Mounting 7 Probe Use 8 Probe Wrap Use 9

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

Ambient Weather WS Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-16 8-Channel Wireless Thermometer with Min/Max Display User Manual

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Alarm System SECURE AS 302

idevices Connected App 4 Battery Replacement 5 Powering On & Off 5 Connecting 6 Mounting 7 Probe Use 7 Probe Wrap Use 9

The Tasty One Top User Guide

Enhance DX. Mattress Replacement System. User Manual

MODEL # EE-8077W. If you have any questions about the operation of your infrared heater, please contact Crane Customer Care.

Ambient Weather WS-0211 Wireless Wendy the Weather Wizard User Manual

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

User Manual. 40 Tower Fan MODEL: WFTR40W

ASPIRE Laboratory Aspirator

PERSONAL COOL MIST ULTRASONIC HUMIDIFIER

WIRELESS MULTI-ZONE DIGITAL THERMOMETER WITH RADIO CONTROLLED CLOCK. Model No (SF Version) Instruction Manual

Forehead Thermometer Instruction manual

READ ME FIRST DIY WIRELESS ALERT. Add-on Alert Sensor. For Swann Wireless Alert systems. Instruction Manual

Alarm Controller Fire and CO

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Table of Contents. English

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

Note To The User: This product has updated features not yet mentioned in the product manual.

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

CORDLESS GLASS ELECTRIC KETTLE WITH BONUS TEA INFUSER

U5600. Wireless Pressure Transducer SPECIFICATIONS

HIn3550 Magnetic Field Monitor User's Manual

Thermometer model 02059

FEATURES AND SPECIFICATIONS

EVAPORATIVE COOLER W

Transcription:

ENGLISH Kinsa Smart Ear ThermometerTM Instructions For Use Thank you for purchasing the Kinsa Smart Ear Thermometer, a professionally accurate instrument for fast and easy temperature taking in the ear. Please read these instructions carefully to ensure accurate temperatures and safe operation. Your Kinsa Smart Ear Thermometer is designed for use with or without a mobile device. For the full experience including features such as symptom tracking and fever guidance, download the Kinsa app on the itunes or Google Play store and connect your thermometer to your mobile device. To see the full list of supported devices, see kinsahealth.com/devices. The World's Smartest Thermometer 1

Product Description C B H A E E E D F G I A Power On/Start button D Display G C/ F switch Bluetooth pairing button Probe B E H Protective cap C Probe tip F Battery door I Kinsa mobile app 2

Indications For Use ENGLISH The Kinsa Smart Ear Thermometer is intended to measure the human body temperature in the ear. This device is reusable for clinical or home use on both adults and children. Warnings And Precautions This thermometer functions with Apple and Android mobile devices. Please see kinsahealth.com/devices for the full list of supported devices. Clean the probe before and after use. Never use the thermometer for purposes other than body temperature measurement. Please follow the safety precautions when using on children. The operating ambient temperature range for this thermometer is 59-104 F (15-40 C). Do not expose the thermometer to temperature extremes: (below -13 F / -25 C or over 131 F / 55 C) or excessive humidity (>95% RH). Use of this thermometer is not intended as a substitute for consultation with your physician. High, prolonged fever requires medical attention. Be sure to contact your physician. The thermometer is water resistant, not waterproof. Never dip the thermometer into water or other liquids. Do not boil the probe. For cleaning and disinfecting, please see Cleaning and Storage. Keep out of reach of unattended children. Do not allow children to walk or run while taking a temperature. Avoid exercise and drinking hot or cold beverages before taking a temperature as these activities may affect accuracy of the reading. Features of your Kinsa Smart Ear Thermometer Fast 1 second reading. Meets ASTM & ISO standards for professional accuracy. Gentle and easy to use in the ear. No probe covers needed. Conveniently displays in F or C. Water resistant, for safe cleaning. Use with or without your mobile device. Connects via Bluetooth Low Energy. Additional Smart functionality available through Kinsa app. Body Temperature Temperature readings vary from person to person, by age, time of day, and by site of measurement. For example, core body temperature often decreases with age. The best method to determine your own normal temperature is to use the thermometer when you are feeling well. Record your temperature twice a day (early morning and late afternoon) using the Kinsa app. Take the average of the two temperatures. This is considered your normal body temperature. Any variation from it may indicate some sort of illness and you should consult your physician. Why Measure in the Ear? Ear temperatures accurately reflect core body temperature, since the ear drum shares a blood supply with the temperature control center in the brain: the hypothalamus.1 The Kinsa Smart Ear Thermometer monitors the infrared heat radiated from the eardrum and surrounding tissue and detects once an accurate temperature measurement has been taken. 1 Netter H F, Atlas of Human Anatomy, Novartis Medical Education, East Hanover, NJ, 1997, pp 63, 95. 3

To Set Up Your Thermometer For First Time Use 1. Download the Kinsa app from the itunes App Store or Google Play. The app can also be downloaded by going directly to kinsahealth.com/download. Please see kinsahealth.com/devices for the full list of supported devices. 2. Enable Bluetooth on your mobile device. 3. Tap the Kinsa app icon on your home screen to open the application. 4. Open the battery door F. Use the C/ F switch G to select the temperature scale for your display. 5. Insert two AAA batteries (included) into the thermometer. Snap battery door into place. 6. Tap the Power/Start button A to turn on the thermometer. 7. The Kinsa app should automatically detect your Kinsa Smart Ear Thermometer. Your mobile device will ask for permission to pair with the thermometer. Select Yes. 8. Your thermometer is now successfully connected to your mobile device. For future temperature readings, open the Kinsa app to automatically sync readings to your mobile device and assign to individual family members, add notes or symptoms/medications, and see fever guidance. To Set Up Your Thermometer with Additional Mobile Devices 1. Download the Kinsa app from the itunes App Store or Google Play. 2. Enable Bluetooth on your mobile device. 3. Tap the Kinsa app icon on your home screen to open the application. 4. On the thermometer, press and hold the Bluetooth pairing button E for 3 seconds. 5. Your mobile device will ask for permission to pair with the thermometer. Select Yes. 6. Your thermometer is now successfully connected to your additional mobile device(s). 4

Taking a Temperature ENGLISH 1. Tap the Power/Start button A to turn on the thermometer. You will hear a beep when the thermometer is ready to take a temperature. During an internal self-check, the display shows all segments. The thermometer will be ready for temperature taking when the screen shows three dashes. 2. Gently tug the ear straight up and back to ensure an accurate temperature reading. Fit the probe snuggly into the ear canal then push and release the Power/Start button. 3. A beep will indicate when the temperature measurement is successfully completed. Temperature readings typically take 1 second. 4. The temperature reading will be shown on the illuminated display. A smiley face will indicate a low, medium, or high temperature. 5. The thermometer will automatically turn off after 30 seconds of inactivity. The display will briefly flash OFF and it will go blank. NOTE: Always take measurements in the same ear since temperature readings may differ from the right and left ear. Kinsa recommends taking your temperature three times in the same ear and using the highest of those readings. This is especially important if you meet the following criteria: 1 Children under three with a compromised immune system 2 Individuals unfamiliar with this thermometer 5

Understanding Your Thermometer Display DISPLAY SITUATION Bluetooth icon, No mobile device paired blinking SOLUTION Download the Kinsa app & enable Bluetooth on your mobile device. Turn on the thermometer while the app is open and follow pairing instructions. Phone with Thermometer has Open Kinsa app. comment icon, stored temperatures or blinking messages to send to app Battery icon, one section Battery is low but thermometer will still operate correctly Insert new batteries. Battery icon, Battery is critically low empty, blinking and may not operate correctly Insert new batteries. ERR Ambient temperature is not within allowed operating range (59-104 F or 15-40 C) Allow the thermometer to remain for 30 minutes where temperature is within ambient range. HI / LO Temperature taken is not within typical human temperature range (93.2-108 F or 34-42.2 C) HI = too high LO = too low Make sure the probe tip and lens are clean. Make sure the thermometer is properly inserted. Then, take a new temperature. If you continue to encounter an error, contact Kinsa Customer Support. Changing The Temperature Scale If you wish to change the temperature scale of your thermometer: 1. Open the battery door F 2. Remove batteries 3. Use the C/ F switch G to select the temperature scale for your display 4. Replace batteries and battery door NOTE: temperature scale in app can be changed within app settings. 6 F G

ENGLISH Cleaning And Storage The probe tip is the most delicate part of the thermometer. It must be clean and intact to ensure accurate readings. To clean the probe tip, gently wipe the surface with a cotton swab or soft cloth moistened with rubbing alcohol. If the probe tip is damaged, please contact Customer Support. Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid. Store thermometer in a dry location free from dust and contamination and away from direct sunlight. Replacing The Batteries The thermometer is supplied with two AAA batteries. To ensure accurate temperatures, replace batteries when they are low. A low battery will be indicated on the display with a flashing icon. F Open the battery door F. Remove old batteries and replace with new batteries, making sure the poles are in the right direction. Snap battery door into place. To protect the environment, dispose of the product and empty batteries at your retail store or at appropriate collection sites according to national or local regulations. Calibration This thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of temperature measurements, please contact Customer Support. Product Specifications Displayed temperature range: Operating ambient temperature range: Display resolution: 93.2 F 108 F (34 C 42.2 C) 59 F 104 F (15 C 40 C) 0.1 F or C ACCURACY FOR PATIENT TEMPERATURE RANGE MAXIMUM LABORATORY ERROR 95.0 F 107.6 F (35 C 42 C): (±0.2 C) ±0.4 F (±0.4 C) Outside this range: ±0.7 F LONG TERM STORAGE RANGES Temperature: Humidity: 13 F to 131 F ( 25 C to 55 C) 15 95 % RH (non-condensing) OTHER Battery type: Battery life: Bluetooth: Two AAA batteries Approx 2 years Bluetooth Low Energy v4.0 7

This thermometer conforms to the following standards: ASTM Standard E 1965-98:2009 Standard Specification for Infrared Thermometers for Intermittent Determination of Patient Temperature EN 12470-5: 2003 «Clinical thermometers» Part 5: Performance of infrared ear thermometers (with maximum device) IEC/EN 60601-1: 3/96 «Medical electrical equipment» Part 1: General requirements for safety IEC/EN 60601-1-2:2014 «Medical electrical equipment» Part 1-2: General requirements for safety electromagnetic disturbances and electromagnetic emissions IEC 60601-1-11:2010 «Medical electrical equipment» - Part 1-11: General requirements for basic safety and essential performance - Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment FCC Rules - This device complies with part 15 of FCC rules. Operation is subject to the following two conditions; (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Manufactured By: Kinsa, Inc 222 Broadway, 19th Fl New York, NY 10038 www.kinsahealth.com Customer Support: support@kinsahealth.com EMERGO EUROPE Molenstraat 15 The Hague, 2513 BH The Netherlands Limited Warranty: Kinsa, Inc warrants this product against any defects that are due to faulty material or workmanship for a period of one year from the original date of consumer purchase or receipt as a gift. This warranty applies when used for normal household use in accordinate with the Instructions for Use and excludes the battery and damage to the product resulting from accident or misuse. This product is not warranted when used in a professional environment. In no event shall Kinsa, Inc be liable for any special, incidental, indirect, or consequential damages in connection with the purchase or use of this product or costs over the original cost of the product. If the product should not perform to specifications within the warranty period, please contact Customer Support. Explanation of Symbols Consult instructions for use Manufacturer batch code Product contains no latex Temperature limitation Catalogue number Type BF applied part Humidity limitation Non-sterile Do not use if product is broken, damaged, or open 0120 8 L-10252 Rev A A-10240 Copyright 2016 Kinsa, Inc. For patents: kinsahealth.com/patents