Ductless Series Variable Speed Split Systems

Similar documents
comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

R-410A DUCTLESS SPLIT SYSTEMS. Single Zone, Dual Zone & Multi Zone Air Conditioners and Heat Pumps

R-410A Ductless Split Systems. Single Zone, Dual Zone & Multi Zone Air Conditioners & Heat Pumps. Chilled Water Fan Coils

Presents. Variable Speed Heat Pump Ductless Split Systems

Single and Multi-Zone Ductless Split Systems

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Single - Zone Systems

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Model: Ceiling Cassette V 9k-24k

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

Specifications, Performance & Submittal

Presents PANTONE COOL GRAY 10 C PANTONE 3155 C

S1CV/S1HV Single-Zone

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

Specifications and Performance S2H

Lennox Mini-Split Systems Year-Round Comfort and Performance

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Residential and Light Commercial Ductless Systems Catalog

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

InverterFlex SERIES InverterFlex Systems condition up to five rooms

... Air Conditioners & Heat Pumps Light Commercial ...

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Divisions of ECR International, Inc. Commercial Zone-Comfort Solutions

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

Quiet Comfort Dependable Performance Guaranteed Energy-Efficient. Mini-Splits Single-Zone & Multi-Zone Systems

Mitsubishi System Technologies:

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

TECHNICAL SPECIFICATIONS

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ductless Split Systems Ceiling Cassette Heat Pumps

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Specifications and Performance

DAIKIN FCQ SERIES HEATING & COOLING SYSTEMS. ROUNDFLOW CEILING-MOUNTED CASSETTE Up to 18.6 SEER / Up to 10.2 HSPF Up to 13.0 EER

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

DUCTLESS SPLIT SYSTEMS

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Air Conditioning & Heating. Ductless Product Catalog

13 SEER CONDENSING UNITS & AIR HANDLERS

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

AIR CONDITIONERS CENTRAL & DUCTLESS. napoleonheatingandcooling.com

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Ductless Systems. Right product for the right application

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

RSG16**S1M. Split System Air Conditioner 16 SEER

Performance and Reliability. CB*, C* and TA* Models

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

RetroAire VPRC/VPRH. Single Packaged Vertical Unit R-410A Refrigerant

About Daikin: WARNINGS:

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Specifications and Performance

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Discover Innovative Comfort

DAIKIN FAQ SERIES HEATING & COOLING SYSTEMS. INDOOR WALL-MOUNTED UNITS Up to 18.6 SEER / Up to 9.4 HSPF Up to 12.7 EER

K sin. Mini Split Air Conditioners and Heat Pump

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

LG Comfort Solutions. Comfort Solutions You Never Thought Possible

Samsung 360 Cassette, Single Zone, Split System

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

DUCTLESS FULL LINE CATALOG

Heat Pumps COMFORT NEED IT. When You

AIR CONDITIONERS 2017 COLLECTION. Window Portable Dehumidifier Through The Wall Ductless Split Units

Heating & Cooling Products

Transcription:

P r e se n t s Ductless Series Variable Speed Split Systems

Ductless Series Variable Speed Split Systems 2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor space when traditional systems are not practical or feasible. E-verter Split Systems are small in size and very flexible for zoning because no ductwork is required. EMI E-verter Split Systems combination of an outdoor condenser and indoor air handler fits almost anywhere simple to install and economical to operate and are ideal for a wide range of applications. Computer rooms, restaurants, apartments and condos, nursing homes, warehouse offices, schools, doctors offices, hotels and motels. EMI E-verter Split Systems primary feature is the inverter-driven compressor that can modulate the speed at which it operates, adjusting the capacity to closely match the load and demand. This functioning reduces temperature swings, cycling, compressor noise and energy usage & costs, while more precisely maintaining comfort. In this brochure you will find a variety of E-verter Split System options that are right for almost any application. E-verter Benefits Variable speed load matching High efficiency 3:1 turn down increases reliability with less cycling Quiet operation Minimal room temperature swings Single or dual point power connections (without electric heat only) Turbo heat plus two stage heating with optional E-boost electric heat Widest selection of energy star eligible ductless products Inverter Technology Inverter technology allows the compressor in the outdoor condensing unit to continuously adjust its speed to match the load and demand of the zone. This method is a substantial improvement on a conventional split system s efficiency because the system compressor will run longer, but at a lower speed, as the system approaches the set temperature. When demand is low, the speed of the compressor, and consequently the electric meter, will slow down; running down to ~1/3 of the rated capacity. This helps to maintain the room temperature with a higher degree of consistency and accuracy. When demand is high, the compressor will speed up, running at full capacity. The compressor does not start and stop nearly as often, which provides energy cost savings, as well as extends the life of the compressor, offering a significant overall payback. Since the compressor does not always run at the highest speed, there is a noise reduction at the outdoor condenser, and at the indoor air handler since it doesn t consistently have to run at the highest fan speed to satisfy demand.

Ductless Series Variable Speed Split Systems High-Wall Air Handler Systems WLHV Series Cooling & Heat Pump 9,000 33,400 Btuh, 2.6 9.8 kw Hand-Held Infrared Remote Control Optional Wired OEM Wall Control ** Indoor Model WLHV09 WLHV09 WLHV12 WLHV12 WLHV18 WLHV18 WLHV24 WLHV24 WLHV30 WLHV30 WLHV36 WLHV36 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 S1CV3000 S1HV3000 S1CV6000 S1HV6000 Type A/C HP A/C HP A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 29,800 29,800 33,400 33,400 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 10,000 29,800 10,000 29,800 12,000 33,400 12,000 33,400 Nominal Heating (Btu/hr) 8,800 10,000 18,000 21,000 26,000 26,400 Min - Max Heating at 47 F (Btu/hr) 2,900 8,800 3,300 10,000 6,000 18,000 7,000 21,000 8,700 26,000 8,700 26,400 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 19,500 19,700 SEER 16.7 16.7 17.0 17.0 17.0 17.0 17.0 17.0 14.5 14.5 14.0 14.0 HSPF 8.2 8.5 9.5 9.5 7.7 7.7 EER 13.5 13.5 12.0 12.0 13.0 13.0 11.0 11.0 10.3 10.3 9.0 9.0 COP 3.2 3.0 3.5 3.2 2.8 2.95 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32-115 60 115* 32-115 60 115* 32-115 Heating Operating Range ( F) 0 75 0 75 0 75 0-75 0-75 0-75 Line Length feet 100 100 100 100 100 100 100 100 100 100 100 100 Indoor Unit Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 45 45 45 45 56 56 56 56 50 50 50 50 Medium (dba) 42 42 42 42 54 54 54 54 48 48 48 48 Low (dba) 40 40 40 40 52 52 52 52 46 46 46 46 Outdoor Unit Transformer Kit required for 115Vac Condenser Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 66/69 66/69 6/69 66/69 Options E-boost Electric Heat (208/230v only) (kw) 3 3 3 3 3 & 5 3 & 5 3 & 5 3 & 5 5 5 5 5 Low Ambient Cooling Range ( F) 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (S1CV Only) and Wind Baffles Kit Added Features Include: Sweep function on louvers provides a wide conditioned area, and evenly distributed airflow throughout the space. Dry mode allows for dehumidification, with minimal change in room temperature. Selectable filter indicator notifies occupant when cleaning is required. Condensate pump accessory includes integral safety switch, is capable of up to 48" (1.2m) lift, and internally mounted. Infrared Remote Test Mode overrides controls for easy start-up and diagnostics. Optional Wired OEM Wall Control; a Handheld Infrared Remote Control comes standard with every air handler. 3

Ductless Series Variable Speed Split Systems Ceiling Cassette Air Handler Systems CAHV Series Cooling & Heat Pump 9,000 36,000 Btuh, 2.6 10.5 kw Hand-Held Infrared Remote Control Optional Wired OEM Wall Control ** Indoor Model CAHV09 CAHV09 CAHV12 CAHV12 CAHV18 CAHV18 CAHV24 CAHV24 CAHV30 CAHV30 CAHV36 CAHV36 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 S1CV3000 S1HV3000 S1CV6000 S1HV6000 Type A/C HP A/C HP A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 30,000 30,000 35,600 35,600 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 10,000 30,000 10,000 30,000 12,000 36,600 11,500 35,600 Nominal Heating (Btu/hr) 8,400 8,800 17,000 19,000 29,000 29,000 Min - Max Heating at 47 F (Btu/hr) 2,800 8,400 2,900 8,800 5,600 17,000 6,200 19,000 9,500 29,000 9,500 29,000 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 19,500 19,500 SEER 15.0 15.0 15.8 15.8 17.0 17.0 17.0 17.0 14.6 14.6 14.25 14.25 HSPF 7.7 7.7 9.0 9.0 7.9 7.9 EER 13.0 13.0 12.0 12.0 13.0 13.0 11.0 11.0 10.5 10.5 9.9 9.9 COP 3.0 3.0 3.1 3.0 3.1 3.1 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 Heating Operating Range ( F) 0 75 0 75 0 75 0 75 0 75 0 75 Line Length (feet) 100 100 100 100 100 100 100 100 100 100 100 100 Indoor Unit Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 41 41 41 41 44 44 44 44 51 51 51 51 Outdoor Unit Medium (dba) 40 40 40 40 43 43 43 43 50 50 50 50 Low (dba) 39 39 39 39 42 42 42 42 49 49 49 49 Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 66/69 66/69 66/69 66/69 Options E-boost Electric Heat (208/230v only) (kw) 1½ 1½ 1½ 1½ 3 3 3 3 5 5 5 5 Low Ambient Cooling Range ( F) 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 0 115 ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (S1CV Only) and Wind Baffles Kit Added Features Include: Factory installed condensate pump includes integral safety switch with 30" (0.76 m) available lift. Easily configured for fresh air intake and up to 2 branch discharge locations. Motorized discharge vanes on CAHV18-24. Optional Wired OEM Wall Control; a Handheld Infrared Remote Control comes standard with every air handler. Selectable filter indicator notifies occupant when unit needs filter cleaning. 4

Ductless Series Variable Speed Split Systems Universal Air Handler Systems Ceiling/Floor-mounted UNHV Series Cooling & Heat Pump 9,000 33,400 Btuh, 2.6 9.8 kw The air handler can be used in either a ceiling or floor mount application. Hand-Held Infrared Remote Control Optional Wired OEM Wall Control ** Indoor Model UNHV09 UNHV09 UNHV12 UNHV12 UNHV18 UNHV18 UNHV24 UNHV24 UNHV30 UNHV30 UNHV36 UNHV36 Outdoor Model S1CV9000 S1HV9000 S1CV2000 S1HV2000 S1CV8000 S1HV8000 S1CV4000 S1HV4000 S1CV3000 S1HV3000 S1CV6000 S1HV6000 Type A/C HP A/C HP A/C HP A/C HP A/C HP A/C HP Energy Star Eligible Nominal Cooling (Btu/hr) 9,000 9,000 12,000 12,000 18,000 18,000 24,000 24,000 29,800 29,800 33,400 33,400 Min - Max Cooling (Btu/hr) 3,000 9,000 3,000 9,000 4,000 12,000 4,000 12,000 6,000 18,000 6,000 18,000 8,000 24,000 8,000 24,000 10,000 29,800 10,000 29,800 12,000 33,400 12,000 33,400 Nominal Heating (Btu/hr) 8,800 10,000 18,000 21,000 26,000 26,400 Min - Max Heating at 47 F (Btu/hr) 2,900 8,800 3,300 10,000 6,000 18,000 7,000 21,000 8,700 26,000 8,700 26,400 Low Temp Turbo Heating at 17 F (Btu/hr) 7,000 7,000 14,000 14,000 19,500 19,700 SEER 16.7 16.7 17.0 17.0 17.0 17.0 17.0 17.0 14.5 14.5 14.0 14.0 HSPF 8.2 8.5 9.5 9.5 7.7 7.7 EER 13.5 13.5 12.0 12.0 13.0 13.0 11.0 11.0 10.3 10.3 9.0 9.0 COP 3.2 3.0 3.5 3.2 2.8 2.95 Cooling Operating Range ( F) 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 60 115* 32 115 Heating Operating Range ( F) 0 75 0 75 0 75 0 75 0 75 0 75 Line Length feet 100 100 100 100 100 100 100 100 100 100 100 100 Indoor Unit Fan Speeds 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto 3+Auto Sound Levels: High (dba) 45 45 45 45 56 56 56 56 50 50 50 50 Outdoor Unit Medium (dba) 42 42 42 42 54 54 54 54 48 48 48 48 Low (dba) 40 40 40 40 52 52 52 52 46 46 46 46 Sound Level (low/high) (dba) 61/64 61/64 61/64 61/64 65/68 65/68 65/69 65/69 66/69 66/69 66/69 66/69 Options E-boost Electric Heat (208/230v only) (kw) 3 3 3 3 3 & 5 3 & 5 3 & 5 3 & 5 5 5 5 5 Low Ambient Cooling Range ( F) 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 0 32 ** ** Becomes 32-115 F with addition of optional Crank Case Heater Kit Must add optional Crank Case Heater Kit (S1CV Only) and Wind Baffles Kit Added Features Include: Multiple drain pans are factory installed, no field modification required. Dry mode allows for dehumidification, with minimal change in room temperature. Selectable filter indicator notifies occupant when cleaning is required. Easily configured for fresh air intake. Plastic filter grille standard, optional metal grille available. Condensate pump accessory includes integral safety switch with 48" (1.2 m) or 144" (3.6 m) available lift Optional Wired OEM Wall Control; a Handheld Infrared Remote Control comes standard with every air handler. 5

Single Zone Condensers Ductless Series Variable Speed Split Systems Single Zone Series Cooling Rated Cooling Range (9,000-36,600 Btuh, 2.64-10.73 kw) Single Zone Series Rated Heating Range (8,400-29,000 Btuh, 2.46-8.50 kw) Number Nominal Model of Cooling Capacity Circuits Btuh S1CV9000 1 9,000 S1CV2000 1 12,000 S1CV8000 1 18,000 S1CV4000 1 24,000 S1CV3000 1 28,800 / 29,800 / 30,000* S1CV6000 1 33,400 / 36,600* For Universal Air Handler * For Cassette Air Handler Side Discharge Condensers Single Zone Number Nominal Nominal Model of Cooling Capacity Heating Capacity Circuits Btuh Btuh S1HV9000 1 9,000 8,800 / 8,400* S1HV2000 1 12,000 10,000 / 8,800* S1HV8000 1 18,000 18,000 / 17,000* S1HV4000 1 24,000 21,000 / 19,000* S1HV3000 1 29,800 / 30,000* 26,000 / 29,000* S1HV6000 1 33,400 / 35,600* 26,400 / 29,000* Hail Guard/Wind Baffle Accessory Comfort Features: 3:1 turn down for increased comfort with decreased temperature swings. Single point power connection is standard. (Electric Heat models require Dual Point power connection.) Standard cooling operation down to: S1CV ~ 60 F/15.5 C & S1HV ~ 32 F/0 C. Turbo-heat logic allows heat & heat pump to function at the same time. Up to 100 EQUIVALENT feet (30.5 m) of interconnecting refrigerant tubing, supporting up to a 35' (10.6 m) elevation differential. Side discharge cabinet with durable injection molded base and enclosed compressor compartment for reduced noise. Coil ground clearance of 12" (0.3 m) provides added protection from the environment year round. Environmentally friendly R-410A refrigerant, with no Ozone Depletion Potential. Easy access connections for refrigerant gauges. Corrosion resistant, powder-coated steel cabinet with PVC coated wire guard coil protection. One year parts, five year compressor warranty. Full range heat pump operation. 6 Options: Field-installed wind baffles kit allows for low ambient cooling operation down to 0 F/32 C (S1CV also requires a field-installed crank case heater).

Field-Installed Optional Accessories Ductless Series Variable Speed Split Systems 115v Transformer Kit field installed for 9,000 and 12,000 Btuh models (not available on systems with E-boost electric heat) Condensate Pump Condensate Pump includes Integral Safety Switch. Provides available lift from the bottom of the air handler as follows: Internal Unit Mounted to 48" (1.2m) External Wall/Floor Mounted to 144" (3.6m) Handheld Infrared Remote Control (standard) Convenient full function cooling and heating control included with every Air Handler. Hand-Held Wireless Controller Wired OEM Wall Control Provides unit control functions in a fixed location, up to 150' away from the air handler. (Includes a single 15' interconnecting cord extension). Interconnecting Cord Extension Comes in 15' sections to locate Wired OEM Wall Control up to 150' away from the air handler. Bi-Flow Filter Dryer Keeps moisture and particulates out of refrigerant system. Wall-Mounted Wired Controller Crank Case Heater Kit required for low ambient cooling to 32 F/0 C on S1CV (Straight Cool) Models (Standard component on S1HV (Heat Pump) Models) Sweat Connection Line Sets in convenient 25' or 50' lengths, both tubes are insulated. Wind Baffles/Hail Guard/Stamped Louver Kit required for low ambient cooling to 0 F/-13 C Discharge Air Branch Duct Collars (for Cassette Air Handlers) MERV 11 High Efficiency Filter Kits (for Universal Air Handlers) Floor Mount Trim/Kick-plate Kits (for Universal Air Handlers) Metal Return Air Grilles with Filter (for Universal Air Handlers) Fresh Air Intake Duct Collar(s) 7

Presents Ductless Series Variable Speed Split Systems www.e-verter.com For complete product information, please refer to individual unit specifications, installation and operation manual, and other product literature found on www.enviromaster.com. Due to on-going product development, specifications are subject to change without notice. Contractor Assistance: 800.325.5479 ECR International, Inc. 2201 Dwyer Avenue Utica, New York 13501 Phone: 800.325.5479 Web: enviromaster.com PN 240009376 Rev C [01/10/2014]