User Manual PRODUCT #: KMEI701. ITEM: Ionto Herb Tower Steamer from Ionto-Comed SOURCE FOR PURCHASE:

Similar documents
IONTO-COMED INSTRUCTION MANUAL IONTO-COMFORT XDREAM BED

I N S T R U C T I O N S

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

AS 50 operating manual, 2013

TH100 Three in One Instant Hot Water Tap

MW402 Integrated Dishwasher

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

FF820 freestanding full height larder fridge Manual for Installation, Use and Maintenance

Safety and Instruction Manual

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

WC141 Integrated Dishwasher Installation, Use and Maintenance

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

JUNEAU JUN. 08/51193/0 Issue 0

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up

SHORT WAVE INFRARED PANEL DRYER

MW401 Integrated Dishwasher

Mobile Air Conditioner Instruction Manual Model TC-N9KM

FF820 Freestanding Full Height Larder Fridge Manual for Installation, Use and Maintenance

WC600 Integrated Dishwasher Installation, Use and Maintenance

PARAGON FRYERS INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: PF9 MODEL: PSF3 MODEL: PSPF9 MODEL: PDPF6 MODEL: PDPF9

FWC152 / FWC302 / FWC602 / FWC622 Wine Coolers

HD9216 HD9217. User manual

Steam Station. Instruction Manual THE SCIENCE BEHIND CLEAN.

WF140 Freestanding Dishwasher

HR 601 C A AUS. ENGLISH Instructions for use Page 2

1.0 INTRODUCTION 3 TABLE OF CONTENTS 2.0 FOR YOUR SAFETY Warnings and Safety Advice Coolants WARRANTY AND 3 CUSTOMER SERVICE 4.0 INS

Kettle SWK 3000 EDS A1

1.5 LITRE COMPACT FRYER

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

FW821 extra large integrated larder fridge Manual for Installation, Use and Maintenance

AWC150, AWC300 & AWC600

FWC153, FWC304, FWC604 & FWC624

FWC152, FWC303, FWC603 & FWC623 Wine Coolers Installation, Use and Maintenance

MINI FOOD CHOPPER INSTRUCTIONS FOR USE. Thank you for purchasing this product. Please read these instructions carefully before use

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Steam Mop Instructions for Use

Operating instructions Page 12. Wine storage cabinet WKt

WC370 Integrated Intelligent dishwasher Manual for Installation, Use and Maintenance

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

Operating Instructions

Operating instructions Page 12. Wine storage cabinet WKt

EHA Hoffmann International GmbH

IMPORTANT WARNINGS Therefore, to avoid breaking it, do not turn it manually in order to seek the correct position.

IMPORTANT SAFETY INSTRUCTIONS

fwc152 / fwc303 / fwc603 / fwc623 Wine Coolers Manual for Installation, Use and Maintenance

ULTRASONIC HUMIDIFIER

MILK FROTHER INSTRUCTIONS FOR USE

FWC860 Wine Cooler Installation, Use and Maintenance

Ceramic Kettle A INTRUCTION MANUAL. Please note this item is not a teapot and should not be used as such.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

TOAST'N EGG. TOASTN'EGG-NC :Mise en page 1 16/10/09 10:38 Page b

instructions OIL FILLED RADIATOR V V and V551225

Hot Chocolate Dispenser

FINO JETSTEAM PRO 52072

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

Operating Instructions Wine storage refrigerator 12/

IMPORTANT SAFETY INFORMATION

INSTRUCTIONS FOR USE. To make the most of your new oven, read the user's instructions carefully and keep them on hand for consultation in the future.

Super Elite Watch cleaning machine

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

L / -014L / -015L

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

Professional SLIM STEAM POCKET MOP S3455UKL OWNER S GUIDE

Traditional Kettle CTK17U CPT445U

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

Installation & Operating Guide

Refresh & Clean Carpet Washer

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

Do not leave the appliance unattended whilst connected to the mains supply. Always use this appliance on a solid, level, non-flammable surface.

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

MOCCA CUBIC AUS/NZ. 08/53066/0 Issue 2

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

PC87 American Style Double Door Fridge Freezer Manual for Installation, Use and Maintenance

Steam Station IRSG Portable DVD Player

instructions 10,000 prize draw PLUS Free Rewards Gallery Register online now to collect your reward See back for details

Portable Electric Patio Heater User's manual

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

Manual for installation, use and maintenance MW200. Integrated Slimline Dishwasher. year. parts + 1 year labour guarantee.

Professional SLIM STEAM POCKET MOP S3455UKJR OWNER S GUIDE

900 Quadrant Steam Shower Cabin with 6 Body Jets

PC71 American Style Fridge Freezer

Virtu 40 series. Coffee machine

Welcome. Safety Instructions

pure indoor living DIGITAL ULTRASONIC HUMIDIFIER MODEL: BU7500 INSTRUCTION MANUAL

Fasteo.

Safety and Instruction Manual

infranomic INFRARED HEATING PANELS Operating and Installation Instructions Wolff+Meier GmbH & Co. KG Glaswerke Am Wingert Langgöns Germany

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

Virtu 60 and 80 series. Coffee machine

WELCOME IMPORTANT SAFEGUARDS

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

EN Variable Temperature Electric Kettle

Purely and Simply.

T-60cm-OVEN-SS T-60cm-OVEN-CM T-60cm-OVEN-BL

14 Bottle Wine Chiller with Digital Display CZ51186

Actual product may differ from the one illustrated

Transcription:

User Manual PRODUCT #: KMEI701 ITEM: Ionto Herb Tower Steamer from Ionto-Comed SOURCE FOR PURCHASE: SpaEquip Inc. www.spaequip.com www.spaequipasia.com www.spaequipeurope.com Corporate Headquarters: 211 Wappo Ave Calistoga, CA 94515 USA USA Office: 707-737-1100 Asia Office: +852 2314 8860 United Kingdom Office: +44 0208 144 6331 FEATURES: The sleek new Herb Tower steamer is sturdy, mobile and allows the secure stacking of the Ionto Modular System. This unit leaves enough room to fit a waste bin below and is very easy to add a magnifying lamp or accessory tray. Features include: Uses tap water. Heats to steam in five minutes. Fully adjustable arm with adjustable flow of steam. 360 degree directional steam. Steam capacity 35-45 minutes. Optic and sonic water level indicator. Quick decalcification and easy clean up. Electronic protection against over-heating/foaming. Pulverized steam replaces traditional pulverizers. 37 1/2" high, 15 3/4" x 17" base, 24 3/4" long steamer arm, total height of unit including steamer arm is 62". 2 year warranty. CE approved. Made in Germany. Oversized item - ships by Truck. SPECIFICATIONS: Dimensions: Electrical: Suggested Outlet: Plumbing: Notes: Warranty: Certifications: Country of Origin: Installed By: 37 1/2" high, 15 3/4" x 17" base, 24 3/4" long steamer arm, total height of unit including steamer wand is 62" 110V AC, 900 Watts Adjacent to unit None None 2 Years CE Germany SpaEquip (if setup is included with order) or Client

IONTO-COMED INSTRUCTION MANUAL IONTO-HERB Art. No. 8112, 8112.3

Contents Safety Instructions...3 Fields of Use...4 Installation...5 Notes for working with the IONTO-HERB...7 Controls and Connections...8 Operation...9 Aroma treatment with herbs and essential oils...11 Cleaning and Care...12 Fault Finding and Solutions...13 Repairs and Maintenance...14 Technical Data...15 Transport, Storage and Operating Conditions...15 Disposal...15 Delivery Contents...15 Accessories...16 This instruction manual contains information intended to ensure safe operation of the IONTO-HERB. Always keep it in close proximity to the device where it is readily available for every user. IONTO-COMED 2006 IONTO-COMED GmbH Boschstrasse 5 D-76344 Eggenstein-Leo. Telephone +49 (0)7 21 / 97 70-0 Telefax +49 (0) 721 / 97 70-2 90 Email: sales@ionto.de http://www.ionto.de 2 by IONTO-COMED

Safety Instructions Before installing and using your IONTO-HERB, carefully read this instruction manual and ensure that all directions and instructions contained are fully understood. It includes important safety information for setting-up, operation and maintenance! If the IONTO-HERB is used for any purpose other than that for which it was designed and as described in this instruction manual, such use will invalidate the manufacturer s warranty and guarantee! The device may only be opened by the manufacturer or by an expert approved and authorised by the manufacturer. When unpacked, check the contents of the delivery to ensure that all parts have been included and that nothing has been damaged during transit. In the event of any doubt, please contact our customer service department. Never use with a damaged mains power supply cable. Do not jam or kink the cable and do not allow it to rest on any hot object (e.g. radiator, lamp, etc). If the mains cable is damaged in any way, switch OFF immediately and disconnect from the mains power supply. Please consult our customer service department before using again. Never attempt to replace the cable yourself! Installation must be carried out according to the manufacturer s instructions. Incorrect installation could result in damage to persons or property, in which case the manufacturer cannot be held responsible! Before connecting to the mains power supply, ensure that the voltage (V) shown on the type plate corresponds with the power supply available. Under no circumstances may the mains plug be disconnected from the socket with wet hands. Never attempt to remove the plug from the socket by pulling the connecting cable! Do not use in damp surroundings, nor splash or immerse in liquid! Allow the device to adjust to the ambient temperature before starting work. Before cleaning, always disconnect the power plug! Never operate the device without water or when the water level is below WATER LEVEL MARK 1. Never use dishwashing liquid for cleaning the device. There is a risk of scalding due to the liquid overheating! Do not allow any remnants of cleaning agent to remain in the water tank after cleaning is finished, otherwise there will be a risk of scalding. Also, unpleasant odours can develop. by IONTO-COMED 3

Fields of Use IONTO-HERB is an electronic herbal steaming device fitted with a safety monitoring system, a digital water level display and an electronically regulated steam flow. In addition to the regulated steam flow the steaming time can be adjusted between 5 and 30 minutes. The steamer will switch off automatically after elapsed steaming time. Herbal steaming, also known as aroma steaming, has an extremely positive effect on the skin. It stimulates the metabolism whilst at the same time providing a feeling of relaxation and calmness. Herbal steaming can be carried out using both essential oils and the plants themselves. The choice of which essential oil or herb to use is decided by the effects they provide. However, when combined with steam they all have one common effect, which is to calm and harmonise the skin metabolism. The blood vessels in the skin dilate and restrictions in the flow are released. A temporary feeling of warmth is felt, without the formation of erithem taking place. The tension of the arrector (porum) musculature relaxes and the skin becomes softer and more elastic. The vegetative skin nerve-ends are soothed and blood circulation and metabolism achieve a healthy balance. As a result, the absorptive capabilities of the skin improve considerably. A further benefit is the special effect of the appropriate plant or essential oil being used. IONTO-COMED provides eight different, purely organic, dried herbal products especially prepared for herbal steaming and aroma treatment using the IONTO- HERB, as well as specially developed combinations of essential oils for the care and pre-treatment of dry, greasy, normal and mixed skin types. 4 by IONTO-COMED

Installation Legend (1) Support Mount (2) Tripod base (3) Waste container (optional) (4) Support shelf for Modular devices (5) Steam chamber base (6) Locking ring (7) Steam head (8) Steam chamber (9) Steam arm Fig. 1: IONTO-HERB A B C D Fig. 2: Installation IONTO-HERB Caution! Risk of instability! The enclosed sand bags (approx. 6 kg) have to place into the tripod base. 1. Installing the tripod: Place the tripod on a firm, level underground. Place the four sand bags into the tripod base. Slide the lid of tripod base over the support mount. Press the lid firmly on the tripod base (see Fig. 2/A). by IONTO-COMED 5

2. Connecting MODULAR devices (optional): Note When using more than 3 devices an additional support shelf for MODULAR devices must be added for stabilization purpose. Place the modular devices on the support shelf. Connect the handpieces and accessories required. Observe the instructions for use supplied with each modular device. Check the voltage (V) shown on the type plate on the module. Connect the power cable to the socket panel. 3. Adjusting the height of the support shelf: Remove the protective cap from the support shelf. Underneath is the locking screw for the support shelf mounting. Release the screw using a screwdriver. Move the support shelf to the required height. Retighten the locking screw. Replace the protective cap over the screw. 4. Inserting the steam chamber: Grasp the steam head mounting with one hand and the opposite side with the other hand. Raise the steam head and swing it to the side. Ensure that the steam head does not tilt. Place the steam chamber on the base. The steam chamber fixes itself automatically. Place the steam head on the steam chamber (see Fig. 2/C). Press the steam head downwards slightly until the seal is fully closed. Insert the steam arm into the opening on the steam head until it locks into place (see Fig. 2/D). 5. Adjusting the steam head to fully close the seal: Note Ensure that the distance between steam chamber base and the top edge of support mount does not exceed 30 cm (see Fig. 2/B). Otherwise, the steam head doesn t fully close the seal. Remove the protective cap from the steam chamber base. Underneath is the locking screw for the steam chamber base. Release the screw using a screwdriver. Move the steam chamber base upwards until the seal is fully closed. Retighten the locking screw. Replace the protective cap over the screw. or: Loosen the screw in the locking ring with a screwdriver. Slide the locking ring downwards. Press the steam head downwards slightly until the seal is fully closed. Slide the locking ring upwards as far as possible (see Fig. 2/C). Tighten the screw in the locking ring. 6 by IONTO-COMED

6. Connecting the steamer to the mains power supply: Connect the mains power cable to the mains power cable on the steam chamber grip. Check the voltage (V) shown on the type plate. Connect the power plug to the mains power supply. The steamer is now ready for use. Notes for working with the IONTO-HERB Before using the IONTO-HERB on a client for the first time, run the device for three steaming cycles to allow any possible odours to escape. Make sure that the person being treated is made aware that the steam arm will become warm. Do not fill the steam chamber with distilled water. Use only normal tap water. Fill the steam chamber slowly with water. Never fill the steam chamber above the WATER LEVEL MARK 3. Always keep the steam chamber and the measuring sensors clean. When cleaning, do not immerse the grip on the steam chamber in water. Never use dishwashing liquid to clean the steam chamber. Do not put any herbs directly into the water or in the herb basket without a bag. Do not raise the lid whilst the device is in operation, there is a risk of scalding due to the hot water and steam. Also, the lid itself can become hot. In order to keep the water in the steam chamber clean for as long as possible, remove the herb basket following each treatment. by IONTO-COMED 7

Controls and Connections 2 3 4 5 Legend (1) Steam chamber base (2) Steam head (3) Steam arm (4) Lid with herb basket (5) Locking ring (6) Steam chamber grip (7) Chamber lock 6 1 7 Fig. 3: IONTO-HERB 8 9 10 11 12 Legend (8) Display for steaming time in minutes (9) Timer-key (5 to 30 minutes) (10) Display for level of intensity (steam flow) LEVEL 1 to 9 (11) Steam flow-key (12) Water level mark LEVEL 1 to 3 (13) ON/OFF-switch 13 Fig. 4: Steam chamber grip 8 by IONTO-COMED

Operation Caution! Risk of scalding or burns! Never fill the steam chamber above WATER LEVEL MARK 3. Do not remove the lid with herb basket during use. Note It is important that normal tap water is used because the water level is electronically measured. Ensure that there is always sufficient water in the steam chamber. 1. Determining the level of water hardness: Before the IONTO-HERB is used, the hardness level of the tap water used must be determined with the test strips provided. If the tap water used has a hardness level of more than 14 German hardness, we recommend the use of a BRITA water filter. When this water filter is used, the steam chamber will remain cleaner, longer, and several steam treatments can be carried out before it has to be cleaned again. Dip a test strip in a beaker containing normal tap water for approx. 1 second. Lift out and shake off any excess water. Wait approx. 1 minute to allow for the reaction. The colour of the test areas 1 to 4 can change from green to red. No change red = water below 3 German hardness Area 1 red = water above 3 German hardness Area 1 2 red = water above 7 German hardness 4 Area 1 3 red = water above 14 German hardness 3 2 Area 1 4 red = water above 21 German hardness 1 2. Starting steaming: You have two possibilities to start steaming. (1) First fill with water and then switch the device ON: Remove the lid with herb basket attached by turning it slightly and lifting it out. Fill the steam chamber slowly with tap water (warm or cold) through the opening. Do not fill above the third measuring sensor. Insert the herb basket with lid attached, whilst turning and pressing it lightly downwards, into the steam head. Move the ON/OFF-switch to ON (Position < I >). Device will perform a self-test: All indicator lamps will light briefly. An acoustic signal will sound. The steam chamber will automatically begin to heat with level 8 of intensity. Steam will be produced after approx. 5 minutes. by IONTO-COMED 9

(2) First switch the device ON, and then fill with water: Switch the ON/OFF-switch to ON (Position < I >). Device will perform a self-test: All indicator lamps will light briefly. An acoustic signal will sound. The upper display generates the message Lo. Remove the lid with herb basket attached by turning it slightly and lifting it out. Fill tap water (warm or cold) through the opening. Indicator lamps on the chamber grip show the level of water. Fill the steam chamber slowly with tap water through the opening but not above the WATER LEVEL MARK 3. Insert the herb basket with lid attached, whilst turning and pressing it lightly downwards, into the steam head. Press the steam flow -key. The steam chamber will start to heat with level 8 of intensity. Steam will be produced after approx. 5 minutes. 3. Setting the steam flow: The steam flow can be regulated by 9 levels of intensity. Press the steam flow -key. The lower display shows the level of intensity. 4. Setting the steaming time: Press the timer -key. The upper display shows the steaming time. The steaming time can be adjusted in steps of 5 minutes. Press the timer -key for approx. 2 seconds to start the steaming time. The decimal point right beside the steaming time starts flashing. The device will switch OFF automatically after elapsed steaming time. 5. Direct the steam arm towards the chosen skin area: Swing the steam arm towards the client. Rotate the steam arm so that the steam flow is directed towards the area of skin to be treated. 6. Switching OFF following treatment: Move the ON/OFF-switch to OFF (Position < 0 >). Remove the lid together with herb basket. Place the lid upside down on the opening to prevent any condensed water that may have formed in the basket from dripping into the steam chamber. 10 by IONTO-COMED

Aroma treatment with herbs and essential oils Caution! Risk of scalding or burns! Never remove the lid with herb basket during operation. Never add herbs or essential oil directly to the water or without using a sack in the herb basket. The water could boil over. Note When using essential oil, put one or two drops on a cotton wool pad or piece of linen. 1. Filling the herb basket with herbs or essential oils: Device must be switched OFF. Remove the lid with herb basket by turning it slightly and lifting it out of the mounting. Separate the lid from the basket by turning it counterclockwise to release the bayonet fixing. Put a sack containing herbs, or a cotton wool pad with essential oil in the herb basket. Attach the lid to the basket by lining up the bayonet markings on the basket with the slots in the lid (Fig. 5). Press the lid firmly onto the herb basket. Lock the bayonet fixing by turning the lid to the right. Insert the herb basket with lid into the steam head whilst turning and pressing it lightly downwards. 2. Starting steam treatment: See Operation, page 9. Locking pins Fig. 5: Herb basket with bayonet fixing Bayonet marking IONTO-COMED supplies purely organic, dried herbal products for aroma treatment, as well as special combinations of essential oils for the care and pre-treatment of different skin types. by IONTO-COMED 11

Cleaning and Care Caution! Risk of scalding! Use only IONTO-COMED Decalcifier (art. no. 8111.001) or vinegar essence to clean the steam chamber. Remove all traces of cleaning agent from the steam chamber. Caution! Risk of electric shock! Always disconnect from the mains power supply before cleaning. Limestone deposits will form in the steam chamber (furring) according to the level of hardness of the water and length of time the device is used. If excessive deposits of limestone are allowed to build up, these will adversely affect the correct functioning of the safety electronics. Therefore, any water remaining in the steam chamber must be emptied out following the final treatment and the steam chamber must be flushed out and dried. Additionally, the steam chamber should be decalcified and cleaned at least every two days. Note Never use dishwashing liquid for cleaning. Risk of scalding! Do not immerse the steam chamber grip in water when cleaning! 1. Removing the steam chamber from the mounting: Disconnect the mains cable. Grasp the steam head mounting with one hand and the opposite side with the other hand. Raise the steam head and swing it to the side. Ensure that the steam head does not tilt. Pull out the chamber lock. Remove the steam chamber. 2. Cleaning and decalcifying the steam chamber: Empty out any used water remaining. Flush out the chamber with clean water. Fill with water up to the third measuring sensor. Add decalcifier and stir briefly. Observe the instructions given for use of the product. Allow the decalcifier to stand in the chamber for at least one hour. Hot water will accelerate the cleaning process, but do not heat the steam chamber. When finished, empty out the water and decalcifier. Carefully clean the chamber and the measuring sensors with a brush (e.g. dishwashing brush or toothbrush) and flush out with clean water. Any remaining traces of limestone can be easily removed without scrubbing. Dry the chamber well. Note All measuring sensors must be kept clean and free of grease. Do not allow any traces of cleaning agent to remain in the chamber, they will cause the safety control to operate and can cause unpleasant smelling vapours. 12 by IONTO-COMED

Fault Finding and Solutions Problem Reason Solution Device switches OFF, a brief acoustic signal sounds and the display generates the message Lo. Device switches OFF, an acoustic signal sounds and the display generates the message Er. Device does not heat up although the water tank is full and the display generates the message Lo. Steam arm drops down. Device does not switch ON. Too little water in the steam chamber. Too much water in the steam chamber. Steam chamber and measuring sensors are dirty. Water foams in the steam chamber, i.e. traces of herbs, oil or cleaning agent are in the water. Limestone deposits in the steam chamber. The electronic control for the steam chamber is set for 7 German water hardness. Distilled water is used! Damping mechanism on the steam arm is loose. Mains power cable not connected correctly. Fuse is defective. Top up with water and press the steam flow -key. Move the ON/OFF-switch to OFF and empty out the water until the third measuring sensor is reached. Switch the device OFF, empty out the water. Clean the steam chamber (see page 12). Switch the device OFF, empty out the water. Clean the steam chamber (see page 12). Switch the device OFF, empty out the water. Clean the steam chamber (see page 12). Empty and refill with normal tap water. Tighten the steam arm mounting (see page 14). Check connection of the mains power cable. Plug must be firmly inserted. Please contact our customer service department. In the event of any other problem arising which is not dealt with above, please contact our customer service department (telephone number on the last page). by IONTO-COMED 13

Repairs and Maintenance The device does not require any special maintenance when used correctly and in compliance with the manufacturer s directions and instructions. However, in the event of any problem arising, please contact our customer service department. Only persons authorised by the manufacturer may perform repairs. Any alterations or repairs performed by non-authorised persons will invalidate any guarantee, warranty or responsibility of the manufacturer. In addition, the safety of the device could be adversely affected. The inspection of the leakage currents and earthing (ground) conductor must be carried out at annual intervals. Tightening the steam arm mounting Carefully draw the steam arm (Fig. 6/2) off the pipe elbow (Fig. 6/1). Ease both halves of the pipe elbow carefully apart. Push the lower rubber ring (Fig. 6/3) upwards with a screwdriver, out of the groove. Pull the pipe elbow out sideways. Tighten the two M3 hexagonal nuts (Fig. 6/4) with a SW 5.5 spanner. Re-attach the two halves of the pipe elbow. Secure into place with the rubber ring. Slide the steam arm back onto the elbow. Fig. 6: Fixing the steam arm 14 by IONTO-COMED

Technical Data Article number: 8112 (IONTO-HERB with tripod) 8112.3 (IONTO-HERB without tripod) Operating voltage: 230 V ~ / 50/60 Hz 110 V ~ / 50/60 Hz Power consumption: 1200 W Fuses: 2x 6.3 A T (at 230 V) 2x 10 A T (at 110 V) Protection class: I Dimensions (W x H x D): 230 x 1000 x 260 mm Weight with tripod: approx. 17 kg Transport, Storage and Operating Conditions Transport only in the manufacturer s original packaging. Transport and storage temperature: -20 C to +50 C Operating temperature: +10 C to +40 C Relative air humidity: max. 90%, non-condensing To avoid the formation of condensation, abrupt changes of temperature should be avoided. Wait until the device has acclimatised to the ambient temperature before putting into operation. Disposal Dispose of the device itself, packaging and accessories in an environmentally friendly manner and in compliance with local regulations. All electrical and electronic products should be disposed of separately from the municipal waste. This crossed-out wheeled bin symbol on the product means the product is covered by the European Directive 2002/96/EC. The product should not be mixed with general household waste. There exists a separate collection system for these products. The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health. It is a precondition for reuse and recycling of used electrical and electronic equipment. Delivery Contents 1x Herbal Steamer IONTO-HERB 1x Steam arm 1x Mains power supply cable 1x Tripod by IONTO-COMED 15

EG-KONFORMITÄTSERKLÄRUNG / DECLARATION OF CONFORMITY gemäß den Bestimmungen der EG-Richtlinie über / in accordance with the EU-Directives for Elektromagnetische Verträglichkeit 89/336/EWG + Änderungen / Electromagnetic Compatibility Directive 89/336/EEC + Modification Elektrische Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen 73/23/EWG + Änderungen / Low Voltage Directive 73/23/EEC + Modification Hersteller / Manufacturer: IONTO-COMED GmbH Adresse / Address: Boschstrasse 5 D-76344 Eggenstein Zertifiziert als Medizinproduktehersteller nach EN ISO 13485 / Certified as medical device manufacturer in accordance with EN ISO 13485 Benannte Stelle / Notified Body: EUROCAT Institute for Certification and Testing GmbH Wittichstrasse 2 D-64295 Darmstadt Hiermit bestätigen wir, dass das Produkt / We certifies that the product Geräteart / Kräuterbedampfungsgerät/ Purpose of equipment: Herbal steamer Gerätetyp / Type of equipment: IONTO-HERB Artikelnr. / Article no: 8112, 8112.3 mit folgenden Normen übereinstimmt / is in accordance with the following standards: EN 61000-6-1:2001 EN 61000-6-3:2001 Eggenstein, 2006-10-16 IONTO-COMED GmbH Manager Martin La Fontaine