User s Manual. i-warm Fluid Warmer

Similar documents
WARM LINE. IV Fluid Warmer. Product Code: J1448. JORGENSEN LABORATORIES PHONE FAX

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

VetPro Solo Installation

Dual Zone Wine Cellar

Sound Cover [ , , , ]

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Outdoor Beverage Center

PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

Blood/Fluid Warmer. The blood/fluid warmer is used to provide safe and effective warming of blood, blood products, and liquids.

PowerVac G Single to Twin Conversion Kit [ ]

TS0 Series Portable Bulb and Capillary

BIOVAC 500 SMOKE EVACUATOR

Multiple use Digital Thermometer With 7 Day Memory

Model 7500EB Portable Eyewash with Heater

Installation and Operation Guide

MIGHTY PRO 1/4 HP CHILLER

Instruction Manual. Compact Portable Ice Maker. Wards.com Enjoy cold, refreshing ice in just 13 minutes

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

(HSTAT Series) Instruction Manual

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Sunleaves Air Conditioner

2.4 Cu. Ft. Compact Refrigerator

5) Do not start or stop the unit by inserting or pulling out the power plug.

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

Cavitator Ultrasonic Cleaner Instruction Manual


PKTEWC. Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Accessible. Durable. Smart.

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Model No. PE2-07R / PE2-09R / 9000 BTU Portable Air Conditioner with dehumidifier & Fan PE2-07R-62 / PE2-09R-32 Operating Instructions

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Electric Wine Cooler. Wine Chilling Refrigerator MODEL:

Utopian Portable A/C

OWNER S MANUAL: Outdoor Beverage Center

Instruction Manual. MODEL: FD1603 POWER SUPPLY: VAC, 60Hz or VAC, 50Hz POWER CONSUMPTION: 250W

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

OWNERS MANUAL MODEL: Steamer PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

Turbo Sonic Raytech. Ultrasonic Cleaner. Operating Instructions

3-in-1 Cooking System

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

HOT WATER BOTTLE BATH PART NUMBER

SimplyClear Pressurized Filter Product Manual

Item Model Description Voltage Amps Watts Plug

Whynter Portable Ice Maker 33 lb capacity - White

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

SELF-CONTAINED POWER MISTER

INSTALLATION & TESTING MANUAL

FreezeAlarm. General Description FA-D /FA-D-AAB. Applications. Features. Specifications. Dimensions

HEAT PRESS USER S GUIDE

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

20 High velocity Air

P4000 Construction Heater

AUTOMATIC STERILIZERS

42 in. Oscillating Tower Fan w/ Remote Control

GENANO AIR PURIFICATION TECHNOLOGY

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

NON-TOUCH THERMOMETER User Manual

Wilbur Curtis Company, Inc. Service Manual WB5GT Water Boiler

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Installation, Operation, and Maintenance Manual

Cavitator Ultrasonic Cleaners

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Outdoor Beverage Center

PORTABLE HAND POWER THREADER 1/2-2

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

User Instruction Manual

hot air popcorn popper

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Whynter Freestanding 121 Can Beverage Refrigerator with Digital Control and Internal Fan

Instruction Manual Item No.: V~, 60Hz

HotPoly Tote Tank / IBC Heaters (TTH Series)

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Operating Instructions

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Syringe Pump. User Manual

Thermal Electric Wine & Beverage Chiller Model: WC-2463W. Instruction Manual

Upright Freezer. Model: UF-311W/ UF-311S USER S MANUAL

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

30 Misting/Oscillating Fan Model Number 01030

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Portable Induction Ranges

EXC-450 User s Manual

Quest Power Electric Heat EHS 31 Pro

Transcription:

i-warm Fluid Warmer User s Manual Midmark Corporation 60 Vista Drive, Box 286 Versailles, OH 45380-0286 Customer Service and Technical Service TEL: 1-800-MIDMARK (1-800-643-6275) www.midmark.com

i-warm Fluid Warmer Features Portable and light weight Warms up all I.V. fluids except transfusion fluids Convenient hanging belt to hang on a stand I.V. temperature displayed in Fahrenheit or Celsius Temperature overheating protection Table of Contents General information... 2 Precautions.2 Equipment Alert..... 3 Product Description... 3 Instructions for Use....4 Effect of Flow Rate on Fluid Temperature.5 Specifications.6 Storage.6 Warranty...7

General Information The i-warm Fluid Warmer is a dry-heat device designed for warming I.V. fluids safely through the heating plate. The warmer does not provide fluid flow rate control. Fluids normally refrigerated can be warmed to temperatures between 96 104ºF (35.5C 40ºC) at flow rates up to 338 ml/hr in room temperature between 68 77ºF (20 25ºC). Because it can reach 104ºF, it is not recommended for blood. Precautions SAVE THIS MANUAL FOR FUTURE REFERENCE! IMPORTANT: Before using the i-warm Fluid Warmer, please read and understand this User s Manual and the SAFETY PRECAUTIONS prior to use. If you have any questions, please contact Midmark Corporation at 1-800-643-6275. Warnings: All air must be purged from the fluid lines prior to connection to the patient. Monitor the fluid lines to insure they are air free. Never administer fluids if there are air bubbles in the line between the drip chamber and the patient connection. Failure to follow the above warnings could result in the administration of air to the patient. This could cause death or serious injury. 2

Equipment Alert The i-warm must be unplugged when not in use. Failure to do so could result in electrical failure Do not immerse in cleaning and/or sterilization solution. Do not submerge or soak unit. It is fluid resistant, not fluid proof. For grounding reliability of the Fluid Warmer, plug only into a properly grounded outlet. Isolation of the power supply can only be achieved by disconnecting the cord from the main power source. The length of the IV line between the patient and warmer should be limited. If over 10 from the patient, heat loss will begin to occur before fluid is infused into the patient. The warmer is designed to be IV pole mounted with the hanging belt which can be adjusted. Product Description 3

Instructions for Use 1. Hang the warmer on the IV pole vertically. Note: If an infusion pump is used, the warmer should be located slightly under the IV line s exit from the pump. 2. Slide the IV line into the groove on the heating plate carefully. Then close the cover of the warmer. 3. Plug the power cord into a properly grounded outlet. It may take 5 to 10 minutes for the warmer to warm up to 104ºF (40ºC). 4. The warmer will start to warm up immediately when it s plugged in. If the heating plate of the warmer reaches 104ºF (40ºC), the warmer will temporarily stop producing heat and the green indicator will go off. The warmer will automatically turn on again once the temperature inside the warmer goes down. 5. If the temperature of the warmer should rise above 108ºF the power should go off. If not, the red light will go on. Unplug the warmer in this case. 6. Press the grey button on the front panel to switch the temperature between Fahrenheit and Celsius. IMPORTANT: A backup system within the warmer is independent of the main controller and monitors fluid temperature continuously. If the output fluid temperature exceeds 113ºF (45ºC), the backup system will immediately interrupt power to the heaters. 4

Effect of Flow Rate on Fluid Fluid temperatures exiting the patient line are affected by flow rate. The following flow vs. output fluid temperature curve shows the warming performance of the i-warm Fluid Warmer. (Fluids being bolused will not gain much benefit from fluid warmers.) Fluid Temperature vs. Flow Rate Note: Temperature is measured at the exit of the warmer. 5

Specifications Suggested Operating Temp. 68 77ºF (20 25ºC) Relative Humidity 80% Maximum Power Requirement 120VAC 60Hz Flow Rate Range 0.1 338 ml/hr Dimensions 7.7 x 3.5 x 2.2 190 x 100 x 60 mm Weight 1.32 lb (0.6 kg) Storage This product should be stored in an environment with an ambient temperature range of 14ºF 131ºF (-10ºC 55ºC), relative humidity below 93%, and air pressure 500hpa 1060hpa. Do not store close to corrosive vapor and/or harmful impurities. 6

Warranty Midmark Corporation warrants that the i-warm Fluid Warmer will be free from defects in materials and workmanship under normal use and service for a period of one year from the date of delivery by the distributor to the first purchaser. If any defect occurs during the one year warranty period, the aforesaid purchaser should call Midmark Corporation at 1-800-643-6275. After the warranty period, Midmark Corporation will provide service, charging for necessary parts. The warmer should be returned properly packaged, postage prepaid. 003-2353-00 Rev. B (5/11) 7