GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

Similar documents
Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

CLIMACIAT AIR COMPACT

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Compact and silent Scroll compressors All-season operation

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

DYNACIAT ILG. Use. Description. Heat pumps

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

High temperature air-to-water heat pumps

DYNACIAT POWER. High energy efficiency Compact and quiet

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

Centrifugal air heaters hot water or electrical supply

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

High temperature air-to-water heat pumps

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

Aquaciat Free cooling

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

HT V2 HT Split

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

AQUACIAT2 HYBRID. Natural GAS condensation boiler Self-adjusting electronic control. Use. Range. Heat pumps and gas boilers

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

NA B GeoCIAT TM Power. Instruction manual

Vertical self-contained air conditioner

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

WZH Ground source heat pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

CRIMSON & CRIMSON MAX

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Process glycol chillers

Advance Split

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Neosys Product catalogue

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

LZA High efficiency air to water heat pumps with HP compressor

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL. Water-to-water heat pump with passive energy recovery.

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

LZT High efficiency air to water heat pumps with E.V.I. compressors

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

NA B AIR COMPACT. Instruction manual

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

PAC BT LOW TEMPERATURE HEAT PUMP

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

KPSW CONSOLE TERMINAL UNIT

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Precision air handling cabinets Ciatronic MICRO/EXPAIR

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Water chillers water/water type SIGMA Technical information manual

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

NA G DYNACIAT LG - LGP LG - LGP. DYNACIAT power

Modular Air-cooled Chillers

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only.

Roof top SPACE RPC 450Z R407C M011

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Technical specifications

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Planning guide. (2010/09) en

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Aquaflair TRAC-TRAF-TRAH

TCHVZ TCEVZ

Transcription:

Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept Option Option Use The glycol/water mix/water heat pump is designed for heating applications (passive cooling optional) in new and existing individual homes. The GeoCIAT Modular is compatible with low to medium temperature transmitters: underfloor heating system, fan coil unit, radiators, etc. The GeoCIAT Modular can also be configured for ground water connection using an optional ITEX AGEO+ sectional heat (water-to-water operation). The GeoCIAT Modular is installed indoors in a machine room, laundry room or garage, protected from frost and adverse weather conditions. The unit is delivered ready for operation (tested and adjusted in the factory). Range The GeoCIAT Modular range, housed in a single-size casing, consists of single-phase models and three-phase model. The range is certified according to the NFPAC heat pump standard and NFPAC Dual Mode by Certita under certificates NF44-85E/068 and NF44-86E/069. Conformity LVD 204/5/EU NF C5-00 EMC 204/0/EU PED 204/6/EU Category WEEE 202/9/EU RoHS 20/65/EU HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B

Components Casing - Galvanised steel free-standing frame on adjustable feet - Casing panels in textured RAL906 white steel - Casing front in matching RAL906 ABS - Noise insulation on the refrigerating/hydraulic/electrical unit - Platform fitted on rubber mounts Compressor - R40A - Hermetic On/Off SCROLL type compressor on rubber mounts - Built-in electric motor cooled by intake gas - Internal motor heat protection Brazed plate heat - End plates and internal plates in AISI 6 stainless steel - High-performance, optimised plate patterns - Thermal insulation Standard refrigerating components - Monoflow dryer - Electronic expansion valve Safety and information components - High pressure switch with automatic reset - HP/LP sensor - Water supply and return sensors on secondary - Water supply sensor on primary - Primary and secondary freon sensors - IO HomeControl radio outdoor air sensor - Water flow rate electronic control Built-in double hydraulic module (primary and secondary) - Two variable speed accelerator pumps, energy efficiency rating A - Two 0L expansion vessels - Two drains via flexible connections HomeConnect control - Remote control terminal (IO HomeControl radio link) - Display of setpoint or room temperature - Reading of water flow rates when the heat pump starts up - Operating settings check - Room temperature compensation - Water law configuration - On/off input control - Back up operation configuration, alternating or simultaneous operation - Auxiliary management - Customer accelerator pump management (heating and well) - Geocooling management (option) - Dual-zone management (option) - Metering of running time and energy metering - RS485 output for CMS link (ModBus-JBus etc.) Electrical panel - Housing meets safety standards EN 605- and EN605-2-40 - Earth connection - Compressor motor switch (depending on the model) - Circuit protection - Starting current limiter as standard (except 20H) Options (for installation on site) - CAPA 00L - Ballon ECS 70L - Geocooling kit - 4 kw extra heater kit - 2-zone kit to be fitted into CAPA 00L - Extra heater kit to be fitted into CAPA 00L - HomeConnect expansion board kit - Charging kit - Flexible connections kit - Pressure release valve and pressure gauge kit - For more details, see the current CIAT catalogue Refrigerant and hydraulic module diagram B HP B Outdoor air sensor (radio) B2 Indoor heat water return sensor B Indoor heat water outlet sensor B4 Outdoor heat water outlet sensor B5 Indoor heat freon sensor HP BP 2 Schräder valve Accelerator pump Expansion vessel B OUTDOOR CIRCUIT INDOOR CIRCUIT 2 J26 2 B4 B5 B2 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B

Quick selection Heat pump Heating capacity at 0/- C 0/5 C* kw 5,42 7,04 9,79 9,78 Power input * kw,26,6 2, 2,5 COP* 4, 4,4 4,2 4,55 Heating capacity at 0/- C 40/45 C* kw 5,6 6,7 9, 9, Power input * kw,54,95 2,84 2,62 COP*,5,4,28,55 Heating capacity at 0/7 C 0/5 C kw 7,5 9,29 2,92 2,9 Power input kw,26,6 2, 2,5 COP 5,68 5,8 5,54 6 Heating capacity at 0/7 C 40/45 C kw 6,8 8,84 2,29 2,29 Power input kw,54,95 2,84 2,62 COP 4,4 4,5 4, 4,68 Power supply 20V - ph - 50Hz + E + N 400V - ph - 50Hz + E + N Sound power* db(a) 48 49 50 50 * NFPAC certified values under no. NF 44-85E/068. Water flow rate IMPORTANT: The minimum flow rates must be observed. If they are not, the may be damaged by frost. CIAT shall not be held liable for frost which results from flow rates below the minimum flow rates stated above. The nominal flow rates are used to size the hydraulic system. Outdoor heat Minimum flow rate (m /h) 0,7 0,85,2,2 Nominal flow rate, heating mode with underground loop (m /h) (),4,7 2,4 2,4 Nominal flow rate, heating mode with ground water (m /h) (2),9 2,4,, Indoor heat () 0/- C // 0/5 C mode (2) 0/7 C // 0/5 C mode Minimum flow rate (m /h) 0,5 0,65 0,85 0,85 Nominal flow rate, heating mode (m /h),,7,7 Hydraulic connections System pipe diameters calculated for a hydraulic connection for your machine of 5m between the unit and the rest of the system. GeoCIAT Modular Hydraulic connection copper tubing Hydraulic connection steel tubing Hydraulic connection PE tubing 20H 28 x /42 - DN2 /4 2 x 2.9 H 28 x /42 - DN2 /4 2 x 2.9 45H 2 x /42 - DN2 /4 40 x.7 45HT 2 x /42 - DN2 /4 40 x.7 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B

Unit dimensions and free space (mm) 685 055 ± 5 Cased view Uncased view Min 600 mm Min 600 mm 0 Min 50 mm 760 508 70 70 70 Min 000 mm GeoCIAT Modular dimensions on delivery (casing kit to be fitted on site) 20H H 45H 45HT L x D x H uncased with feet mm 640 x 72 x 05 Weight kg 25 40 40 8 GeoCIAT Modular dimensions (cased module) 20H H 45H L x D x H cased with feet mm 685 x 760 x 055 ±5 Weight kg 46 6 6 59 Diameter of water inlets/outlets "G male 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B

Technical characteristics Compressor Indoor heat Indoor hydraulic module Outdoor heat Outdoor hydraulic module Heat pump Quantity Type On/Off SCROLL Oil capacity (POE) L 0.7.24.24.2 R40A charge kg / TCO 2 eq / 2,09,05 / 2,9, / 2,, / 2, Type Brazed plate heat Capacity L.06 Expansion vessel capacity L 0 Vessel precharge pressure bar.5 Minimum water capacity of system L 78 00 8 40 Max. water capacity (40 C) of the system (pure water/glycol/water mix)* L 250/76 Variable speed accelerator pump. Operating pressure** kpa 72.54 6.6 48.66 45.74 Type Brazed plate heat Capacity L.9 Expansion vessel capacity L 0 Vessel precharge pressure bar.5 Minimum water capacity of system L depends on catchment area Max. water capacity of the system (pure water/glycol/water mix)* L 24 Variable speed accelerator pump. Operating pressure** kpa 57.8 50.9 2.9 24.4 * If greater, install an additional or larger expansion vessel, ** in the nominal mode (0/- C 0/5 C) Electrical characteristics Power supply 20V - ph - 50Hz + T + N 400V - ph - 50Hz + T + N Compressor A 2.8 7. 22.8 7.4 Indoor accelerator pump A 0.52 Max. current Outdoor accelerator pump A 0.7 HomeConnect control A 0.5 Indoor accelerator pump W 70 Max. power Outdoor accelerator pump W 87 Nominal current of the unit (0/7 C // 0/5 C) A 6.52.5.8 4.5 Maximum unit current A 4.2 8.5 24.2 8.8 Starting current without/with starter kit A 40 / - 8 / <45 08 / <45 5 / - PVC electrical cables (not supplied) () mm² 2.5 4 6.5 PVC-V2-K High Temperature electrical cables (not supplied) mm².5 2.5 4.5 Pool sensor, On/Off input connections mm² See relevant KIT manuals Control circuit connection kit mm² See relevant KIT manuals C or D curve circuit breaker (not supplied) A 6 20 2 0 () Cable with 2 or charged PVC conductors for temperatures below 50 C and for a maximum length of 0m Sound levels NFPAC-certified sound power db(a) 48 49 50 50 Indoor sound pressure* db(a) 26 27 28 28 * Sound pressure measured 5 m from unit,.5 m from floor, free field, directivity 2. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B 7

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office 700 Avenue Jean Falconnier - B.P. 4 050 - Culoz - France Tel.: + (0)4 79 42 42 42 Fax: + (0)4 79 42 42 0 info@ciat.fr - www.ciat.com Certified Management System Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 4 4 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B