Plug&Heat heat pump HomeConnect control For residential and tertiary applications Heating capacity (0/- C ): 5 to 9 kw Heating capacity (0/7 C ): 7 to kw Domestic 62 40A hot water Geo Cooling Modular Concept Option Option Use The glycol/water mix/water heat pump is designed for heating applications (passive cooling optional) in new and existing individual homes. The GeoCIAT Modular is compatible with low to medium temperature transmitters: underfloor heating system, fan coil unit, radiators, etc. The GeoCIAT Modular can also be configured for ground water connection using an optional ITEX AGEO+ sectional heat (water-to-water operation). The GeoCIAT Modular is installed indoors in a machine room, laundry room or garage, protected from frost and adverse weather conditions. The unit is delivered ready for operation (tested and adjusted in the factory). Range The GeoCIAT Modular range, housed in a single-size casing, consists of single-phase models and three-phase model. The range is certified according to the NFPAC heat pump standard and NFPAC Dual Mode by Certita under certificates NF44-85E/068 and NF44-86E/069. Conformity LVD 204/5/EU NF C5-00 EMC 204/0/EU PED 204/6/EU Category WEEE 202/9/EU RoHS 20/65/EU HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B
Components Casing - Galvanised steel free-standing frame on adjustable feet - Casing panels in textured RAL906 white steel - Casing front in matching RAL906 ABS - Noise insulation on the refrigerating/hydraulic/electrical unit - Platform fitted on rubber mounts Compressor - R40A - Hermetic On/Off SCROLL type compressor on rubber mounts - Built-in electric motor cooled by intake gas - Internal motor heat protection Brazed plate heat - End plates and internal plates in AISI 6 stainless steel - High-performance, optimised plate patterns - Thermal insulation Standard refrigerating components - Monoflow dryer - Electronic expansion valve Safety and information components - High pressure switch with automatic reset - HP/LP sensor - Water supply and return sensors on secondary - Water supply sensor on primary - Primary and secondary freon sensors - IO HomeControl radio outdoor air sensor - Water flow rate electronic control Built-in double hydraulic module (primary and secondary) - Two variable speed accelerator pumps, energy efficiency rating A - Two 0L expansion vessels - Two drains via flexible connections HomeConnect control - Remote control terminal (IO HomeControl radio link) - Display of setpoint or room temperature - Reading of water flow rates when the heat pump starts up - Operating settings check - Room temperature compensation - Water law configuration - On/off input control - Back up operation configuration, alternating or simultaneous operation - Auxiliary management - Customer accelerator pump management (heating and well) - Geocooling management (option) - Dual-zone management (option) - Metering of running time and energy metering - RS485 output for CMS link (ModBus-JBus etc.) Electrical panel - Housing meets safety standards EN 605- and EN605-2-40 - Earth connection - Compressor motor switch (depending on the model) - Circuit protection - Starting current limiter as standard (except 20H) Options (for installation on site) - CAPA 00L - Ballon ECS 70L - Geocooling kit - 4 kw extra heater kit - 2-zone kit to be fitted into CAPA 00L - Extra heater kit to be fitted into CAPA 00L - HomeConnect expansion board kit - Charging kit - Flexible connections kit - Pressure release valve and pressure gauge kit - For more details, see the current CIAT catalogue Refrigerant and hydraulic module diagram B HP B Outdoor air sensor (radio) B2 Indoor heat water return sensor B Indoor heat water outlet sensor B4 Outdoor heat water outlet sensor B5 Indoor heat freon sensor HP BP 2 Schräder valve Accelerator pump Expansion vessel B OUTDOOR CIRCUIT INDOOR CIRCUIT 2 J26 2 B4 B5 B2 2 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B
Quick selection Heat pump Heating capacity at 0/- C 0/5 C* kw 5,42 7,04 9,79 9,78 Power input * kw,26,6 2, 2,5 COP* 4, 4,4 4,2 4,55 Heating capacity at 0/- C 40/45 C* kw 5,6 6,7 9, 9, Power input * kw,54,95 2,84 2,62 COP*,5,4,28,55 Heating capacity at 0/7 C 0/5 C kw 7,5 9,29 2,92 2,9 Power input kw,26,6 2, 2,5 COP 5,68 5,8 5,54 6 Heating capacity at 0/7 C 40/45 C kw 6,8 8,84 2,29 2,29 Power input kw,54,95 2,84 2,62 COP 4,4 4,5 4, 4,68 Power supply 20V - ph - 50Hz + E + N 400V - ph - 50Hz + E + N Sound power* db(a) 48 49 50 50 * NFPAC certified values under no. NF 44-85E/068. Water flow rate IMPORTANT: The minimum flow rates must be observed. If they are not, the may be damaged by frost. CIAT shall not be held liable for frost which results from flow rates below the minimum flow rates stated above. The nominal flow rates are used to size the hydraulic system. Outdoor heat Minimum flow rate (m /h) 0,7 0,85,2,2 Nominal flow rate, heating mode with underground loop (m /h) (),4,7 2,4 2,4 Nominal flow rate, heating mode with ground water (m /h) (2),9 2,4,, Indoor heat () 0/- C // 0/5 C mode (2) 0/7 C // 0/5 C mode Minimum flow rate (m /h) 0,5 0,65 0,85 0,85 Nominal flow rate, heating mode (m /h),,7,7 Hydraulic connections System pipe diameters calculated for a hydraulic connection for your machine of 5m between the unit and the rest of the system. GeoCIAT Modular Hydraulic connection copper tubing Hydraulic connection steel tubing Hydraulic connection PE tubing 20H 28 x /42 - DN2 /4 2 x 2.9 H 28 x /42 - DN2 /4 2 x 2.9 45H 2 x /42 - DN2 /4 40 x.7 45HT 2 x /42 - DN2 /4 40 x.7 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B
Unit dimensions and free space (mm) 685 055 ± 5 Cased view Uncased view Min 600 mm Min 600 mm 0 Min 50 mm 760 508 70 70 70 Min 000 mm GeoCIAT Modular dimensions on delivery (casing kit to be fitted on site) 20H H 45H 45HT L x D x H uncased with feet mm 640 x 72 x 05 Weight kg 25 40 40 8 GeoCIAT Modular dimensions (cased module) 20H H 45H L x D x H cased with feet mm 685 x 760 x 055 ±5 Weight kg 46 6 6 59 Diameter of water inlets/outlets "G male 6 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B
Technical characteristics Compressor Indoor heat Indoor hydraulic module Outdoor heat Outdoor hydraulic module Heat pump Quantity Type On/Off SCROLL Oil capacity (POE) L 0.7.24.24.2 R40A charge kg / TCO 2 eq / 2,09,05 / 2,9, / 2,, / 2, Type Brazed plate heat Capacity L.06 Expansion vessel capacity L 0 Vessel precharge pressure bar.5 Minimum water capacity of system L 78 00 8 40 Max. water capacity (40 C) of the system (pure water/glycol/water mix)* L 250/76 Variable speed accelerator pump. Operating pressure** kpa 72.54 6.6 48.66 45.74 Type Brazed plate heat Capacity L.9 Expansion vessel capacity L 0 Vessel precharge pressure bar.5 Minimum water capacity of system L depends on catchment area Max. water capacity of the system (pure water/glycol/water mix)* L 24 Variable speed accelerator pump. Operating pressure** kpa 57.8 50.9 2.9 24.4 * If greater, install an additional or larger expansion vessel, ** in the nominal mode (0/- C 0/5 C) Electrical characteristics Power supply 20V - ph - 50Hz + T + N 400V - ph - 50Hz + T + N Compressor A 2.8 7. 22.8 7.4 Indoor accelerator pump A 0.52 Max. current Outdoor accelerator pump A 0.7 HomeConnect control A 0.5 Indoor accelerator pump W 70 Max. power Outdoor accelerator pump W 87 Nominal current of the unit (0/7 C // 0/5 C) A 6.52.5.8 4.5 Maximum unit current A 4.2 8.5 24.2 8.8 Starting current without/with starter kit A 40 / - 8 / <45 08 / <45 5 / - PVC electrical cables (not supplied) () mm² 2.5 4 6.5 PVC-V2-K High Temperature electrical cables (not supplied) mm².5 2.5 4.5 Pool sensor, On/Off input connections mm² See relevant KIT manuals Control circuit connection kit mm² See relevant KIT manuals C or D curve circuit breaker (not supplied) A 6 20 2 0 () Cable with 2 or charged PVC conductors for temperatures below 50 C and for a maximum length of 0m Sound levels NFPAC-certified sound power db(a) 48 49 50 50 Indoor sound pressure* db(a) 26 27 28 28 * Sound pressure measured 5 m from unit,.5 m from floor, free field, directivity 2. HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B 7
This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification. Head office 700 Avenue Jean Falconnier - B.P. 4 050 - Culoz - France Tel.: + (0)4 79 42 42 42 Fax: + (0)4 79 42 42 0 info@ciat.fr - www.ciat.com Certified Management System Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 728 480 - R.C.S. Bourg-en-Bresse B 545 620 4 4 HEAT PUMPS - AIR CONDITIONING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE - NA 6.77 B